Search NASA⌕ Search

SEARCH · Search NASA

Results for “Replication”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

1999 Correlation of N2O4 Analyses by Seven Laboratories

This work describes the range of average values seven laboratories reported for the following attributes found in propellant dinitrogen tetroxide (N2O4): nitric oxide (NO) percent by weight (wt%); assay wt%; water equivalent wt%; chloride content wt%; nonvolatile residue (mg/L); iron content (ppmw); and particulate (mg/L). These analyses of propellant N2O4 are required for specification conformance testing and quality assurance of missile propellants. The paramount purpose of this investigation was to determine the range of values that laboratories report for NO wt% content of N2O4. It was found that one laboratory had significantly different NO wt% values for a single sample of N2O4. Future correlation investigations will be conducted using more replicate testing and more carefully specified replicate determinations.

Wurzbach, Roy↗

Bring'em Back Alive or at Least Carefully

Within the next decade, the world's space agencies plan to launch a variety of robotic spacecraft that will return samples from the surface of Mars, the tail of a comet, the nucleus of a comet, the surface of an asteroid, and the solar wind. Most of these places are not considered likely spots for life, but any mission returning from a location with the potential for harboring life will require special containment and handling because of the possible inclusion of living entities within returned samples. In its 1997 report on sample return from Mars, the Space Studies Board of the National Research Council (NRC) noted that the only risk of significant adverse effects would be from returning a replicating organism. Furthermore, the report noted: 'While the probability of returning a replicating biological entity in a sample from Mars' is judged to be low and the risk of pathogenic or ecological effects is lower still, the risk is not zero. Therefore, it is reasonable that NASA adopt a prudent approach, erring on the side of caution and safety when dealing with returned samples. More recently, a 1998 NRC report on small solar system bodies (asteroids, comets, planetary satellites, and interplanetary dust) recommended a similarly cautious approach for samples returned from anywhere else within the solar system that could have environmental conditions conducive for harboring life. We have not detected life elsewhere in the solar system, at least not yet. Nonetheless, the rationale behind the conservative approach to sample handling is similar to the environmental, health, and safety measures taken on Earth when transporting or handling infectious agents or importing non-native organisms to a new area. Better safe than sorry.

Race, Margaret S.↗

Longitudinal Mode Aeroengine Combustion Instability: Model and Experiment

Combustion instabilities in gas turbine engines are most frequently encountered during the late phases of engine development, at which point they are difficult and expensive to fix. The ability to replicate an engine-traceable combustion instability in a laboratory-scale experiment offers the opportunity to economically diagnose the problem more completely (to determine the root cause), and to investigate solutions to the problem, such as active control. The development and validation of active combustion instability control requires that the casual dynamic processes be reproduced in experimental test facilities which can be used as a test bed for control system evaluation. This paper discusses the process through which a laboratory-scale experiment and be designed to replicate an instability observed in a developmental engine. The scaling process used physically-based analyses to preserve the relevant geometric, acoustic, and thermo-fluid features, ensuring that results achieved in the single-nozzle experiment will be scalable to the engine.

Cohen, J. M.↗

The First SeaWiFS HPLC Analysis Round-Robin Experiment (SeaHARRE-1)

Four laboratories, which had contributed to various aspects of SeaWiFS calibration and validation activities, participated in the first SeaWiFS HPLC Analysis Round-Robin Experiment (SeaHARRE-1): Horn Point Laboratory (USA), the Joint Research Centre (Italy), the Laboratoire de Physique et Chimie Marines (France), and the Marine and Coastal Management group (South Africa). The analyses of the data are presented in Chapter 1 and the individual methods of the four groups are presented in Chapters 2-5. The average (or overall) conclusions of the round-robin are derived from 12 in situ stations occupied during a cruise in the Mediterranean Sea, although, only 11 stations are used in the analyses. The data set is composed of 12 replicates taken during each sampling opportunity with 3 replicates going to each of the 4 laboratories. The average (or overall) results from the intercomparison of 15 pigments or pigment associations are as follows (in some cases, data subsets that exclude pigments which were not analyzed by all the laboratories, or that had unusually large variances, are used to exclude a variety of problematic pigments): a) the accuracy of the four methods in determining the concentration of total chlorophyll a is 7.9%, (one method did not separate mono- and divinyl chlorophyll a, and if the samples containing significant divinyl chlorophyll a concentrations are ignored, the four methods have an accuracy of 6.7%); b) the accuracy in determining the full set of pigments is 19.1%; c) there is a reduction in accuracy of approximately - 12.2% for every decade (factor of 10) decrease in concentration (based on a data subset); d) the precision of the four methods using a subset data is 8.617( 6.2% for an edited subset); e) the repeatability of the four methods using the subset data is 9.2% (7.2%; for an edited subset, and f) the reproducibility of the four methods using the subset data is 21.31% (15.0% for an edited subset).

Hooker, Stanford B.↗

Fabricating High Resolution Mirrors for Hand X-Ray Astronomy

We describe the fabrication process for producing high-resolution conical mirrors for hard x-ray astronomy. When flown aboard stratospheric balloons, these high-resolution reflective mirrors focus hard x-rays (10-70 keV) emitted from cosmic sources such as supernovae, neutron stars, and quasars onto imaging focal plane detectors. Focused hard x-ray images allow scientists to determine the elemental compositions, temperatures, magnetic fields, velocities, and gravitational fields of these celestial bodies. The fabrication process involves generating super-polished mandrels, mandrel metrology, mirror shell nickel electroforming, and mirror testing. Each mandrel is a cylinder consisting of two conical segments; each segment is approximately 305-mm long. Through precision grinding these mandrels before super polishing, we have achieved 30 arc seconds, half power diameter replicated mirrors. During a May 2001 high atmosphere balloon flight, these mirrors focused high energy x-rays from three different celestial sources. However, we seek to improve the angular resolutions of future mirror shells by a factor of two. To achieve this goal, we have begun single point diamond turning the mandrels before super polishing. This has allowed greater precision tolerances on mandrel surface roughness and axial figure errors before super polishing. Surface roughnesses before polishing have been reduced from approximately 60 nm to approximately 15 nm. The peak to valley axial figure profile errors have been reduced from approximately 1.0 micrometers to approximately 0.4 micrometers. We are currently in Phase 2 of the HERO (high energy replicated optics) program which entails the production of sixteen 6-m-focal-length mirror modules, each containing a nested array of 15 mirror shells of diameters ranging from 50-mm to 94-mm. This flight is slated for the fall of 2003.

Speegle, Chet O.↗

The Development of Hard-X-Ray Optics at MSFC

We are fabricating optics for the hard-x-ray region using electroless nickel replication. The attraction of this process, which has been widely used elsewhere, is that the resulting full shell optics are inherently table and thus can have very good angular resolution. The challenge with this process is to develop lightweight optics (nickel has a relatively high density of 8.9 g / cu cm), and to keep down the costs of mandrel fabrication. We accomplished the former through the development of high-strength nickel alloys that permit very thin shells without fabrication- and handling-induced deformations. For the latter, we have utilized inexpensive grinding and diamond turning to figure the mandrels and then purpose-built polishing machines to finish the surface. In-house plating tanks and a simple water-bath separation system complete the process. To date we have built shells ranging in size from 5 cm diameter to 50 cm, and with thickness down to 100 micron. For our HERO (high energy replicated optics) balloon program, we are fabricating over 200 iridium-coated shells, 250 microns thick, for hard-x-ray imaging up to 75 keV. Early test results on these have indicated half-power-diameters of 15 arcsec. The status of these and other hard-x-ray optics will be reviewed.

Ramsey, Brian D.↗

Maintaining the Body's Immune System: Incidence of Latent Virus Shedding During Space Flight

Your body protects you from illness with its own security system - the immune system. This system keeps illness at bay not only by mounting a defense against foreign organisms, but also by controlling the population of bacteria and viruses that normally live in your body. But there's no need to panic: certain microbes can actually exist in your body without causing illness. Some bacteria are even beneficial - like the E. coli in the large intestine that are an important source of vitamin K. While viruses are not exactly considered beneficial, they can also inhabit the human body without causing immediate harm or infection. A good example is the herpes simplex virus type 1 (HSV1), more commonly known as cold sores or fever blisters. This virus infects 70 to 80 percent of all adults but remains latent much of the time. While latent, the virus within cells remains dormant. Activation of the dormant virus causes it to make copies of itself (known as replication) constantly detectable in body fluids such as urine or saliva in a process called shedding. When a person becomes sick or stressed, however, this weakened condition allows the virus to reactivate and multiply. These elevated levels may be enough to produce symptoms, but shedding can also occur without symptoms. This ability to shed without showing signs of infection, or asymptomatic shedding, is of great interest, as it increases the chances of infecting others. The stresses associated with space flight - adapting to microgravity, isolation from family and friends, living and working in a confined space, sleep deprivation, and busy schedules, to name but a few - may weaken astronauts' immune systems, leaving them at greater risk of viral reactivation. Members of the STS-107 crew will participate in this experiment, Incidence of Latent Viral Shedding in Space Flight, to help scientists understand how reactivation works in space, and at what level replication reaches before symptoms begin to show. This study also promises more insight into the behavior of the larger virus family, herpesvirus, which will help us understand how to prevent infection in populations on Earth and reactivation in those already infected.

Pierson, Duane↗

Device Control Using Gestures Sensed from EMG

In this paper we present neuro-electric interfaces for virtual device control. The examples presented rely upon sampling Electromyogram data from a participants forearm. This data is then fed into pattern recognition software that has been trained to distinguish gestures from a given gesture set. The pattern recognition software consists of hidden Markov models which are used to recognize the gestures as they are being performed in real-time. Two experiments were conducted to examine the feasibility of this interface technology. The first replicated a virtual joystick interface, and the second replicated a keyboard.

Wheeler, Kevin R.↗

Preliminary Design and Evaluation of Portable Electronic Flight Progress Strips

There has been growing interest in using electronic alternatives to the paper Flight Progress Strip (FPS) for air traffic control. However, most research has been centered on radar-based control environments, and has not considered the unique operational needs of the airport air traffic control tower. Based on an analysis of the human factors issues for control tower Decision Support Tool (DST) interfaces, a requirement has been identified for an interaction mechanism which replicates the advantages of the paper FPS (e.g., head-up operation, portability) but also enables input and output with DSTs. An approach has been developed which uses a Portable Electronic FPS that has attributes of both a paper strip and an electronic strip. The prototype flight strip system uses Personal Digital Assistants (PDAs) to replace individual paper strips in addition to a central management interface which is displayed on a desktop computer. Each PDA is connected to the management interface via a wireless local area network. The Portable Electronic FPSs replicate the core functionality of paper flight strips and have additional features which provide a heads-up interface to a DST. A departure DST is used as a motivating example. The central management interface is used for aircraft scheduling and sequencing and provides an overview of airport departure operations. This paper will present the design of the Portable Electronic FPS system as well as preliminary evaluation results.

Doble, Nathan A.↗

Stress-induced reactivation of Epstein-Barr virus in astronauts

Herpesviruses are leading causes of infectious blindness and death in immunocompromised individuals. Impaired cellular immunity, which is known to result in increased frequency and severity of herpesvirus infections, has been demonstrated both during and after spaceflight. Therefore, we examined whether Epstein-Barr virus (EBV), a well-characterized latent herpesvirus, undergoes reactivation in astronauts. Sera from Shuttle astronauts, taken before and after spaceflight, were examined for evidence of EBV reactivation. The geometric mean antibody titer to EBV viral capsid antigen (VCA) was significantly increased prior to flight compared to baseline (p = 0. 0001). After spaceflight, evidence of acute lytic replication was found in which 8- to 64-fold increases in EBV early antigen (EA) antibodies occurred without significant increases in antibodies to measles virus. Additionally, stress-induced shifts in circulating leukocytes and elevated levels of urinary cortisol and epinephrine were found. Overall, significant increases in EA or high VCA/EA antibody titers were found in 8 of 23 (35%) male astronauts and 3 of 5 (60%) female astronauts. These results indicate that stress reactivates EBV prior to flight and suggest that acute lytic replication of EBV occurs during spaceflight. Copyright 2000 S. Karger AG, Basel.

NASA Discipline Environmental Health↗

Viral carcinogenesis: revelation of molecular mechanisms and etiology of human disease

The RNA and DNA tumor viruses have made fundamental contributions to two major areas of cancer research. Viruses were vital, first, to the discovery and analysis of cellular growth control pathways and the synthesis of current concepts of cancer biology and, second, to the recognition of the etiology of some human cancers. Transforming retroviruses carry oncogenes derived from cellular genes that are involved in mitogenic signalling and growth control. DNA tumor viruses encode oncogenes of viral origin that are essential for viral replication and cell transformation; viral oncoproteins complex with cellular proteins to stimulate cell cycle progression and led to the discovery of tumor suppressors. Viral systems support the concept that cancer development occurs by the accumulation of multiple cooperating events. Viruses are now accepted as bona fide etiologic factors of human cancer; these include hepatitis B virus, Epstein-Barr virus, human papillomaviruses, human T-cell leukemia virus type I and hepatitis C virus, plus several candidate human cancer viruses. It is estimated that 15% of all human tumors worldwide are caused by viruses. The infectious nature of viruses distinguishes them from all other cancer-causing factors; tumor viruses establish long-term persistent infections in humans, with cancer an accidental side effect of viral replication strategies. Viruses are usually not complete carcinogens, and the known human cancer viruses display different roles in transformation. Many years may pass between initial infection and tumor appearance and most infected individuals do not develop cancer, although immunocompromised individuals are at elevated risk of viral-associated cancers. Variable factors that influence viral carcinogenesis are reviewed, including possible synergy between viruses and environmental cofactors. The difficulties in establishing an etiologic role for a virus in human cancer are discussed, as well as the different approaches that proved viral links to cancer. Future directions for tumor virus studies are considered.

NASA Program Biomedical Research and Countermeasur↗

2-deoxy-D-glucose-induced metabolic stress enhances resistance to Listeria monocytogenes infection in mice

Exposure to different forms of psychological and physiological stress can elicit a host stress response, which alters normal parameters of neuroendocrine homeostasis. The present study evaluated the influence of the metabolic stressor 2-deoxy-D-glucose (2-DG; a glucose analog, which when administered to rodents, induces acute periods of metabolic stress) on the capacity of mice to resist infection with the facultative intracellular bacterial pathogen Listeria monocytogenes. Female BDF1 mice were injected with 2-DG (500 mg/kg b. wt.) once every 48 h prior to, concurrent with, or after the onset of a sublethal dose of virulent L. monocytogenes. Kinetics of bacterial growth in mice were not altered if 2-DG was applied concurrently or after the start of the infection. In contrast, mice exposed to 2-DG prior to infection demonstrated an enhanced resistance to the listeria challenge. The enhanced bacterial clearance in vivo could not be explained by 2-DG exerting a toxic effect on the listeria, based on the results of two experiments. First, 2-DG did not inhibit listeria replication in trypticase soy broth. Second, replication of L. monocytogenes was not inhibited in bone marrow-derived macrophage cultures exposed to 2-DG. Production of neopterin and lysozyme, indicators of macrophage activation, were enhanced following exposure to 2-DG, which correlated with the increased resistance to L. monocytogenes. These results support the contention that the host response to 2-DG-induced metabolic stress can influence the capacity of the immune system to resist infection by certain classes of microbial pathogens.

Non-NASA Center↗

Gamma-Ray Focusing Optics for Small Animal Imaging

There is a well-established need for high-resolution radionuclide imaging techniques that provide non-invasive measurement of physiological function in small animals. We, therefore, have begun developing a small animal radionuclide imaging system using grazing incidence mirrors to focus low-energy gamma-rays emitted by I-125, and other radionuclides. Our initial prototype optic, fabricated from thermally-formed glass, demonstrated a resolution of 1500 microns, consistent with the performance predicted by detailed simulations. More recently, we have begun constructing mirrors using a replication technique that reduces low spatial frequency errors in the mirror surface, greatly improving the resolution. Each technique offers particular advantages: e.g., multilayer coatings are easily deposited on glass, while superior resolution is possible with replicated optics. Scaling the results from our prototype optics, which only have a few nested shells, to system where the lens has a full complement of several tens of nested shells, a sensitivity of approx. 1 cps/micro Ci is possible, with the exact number dependent on system magnification and radionuclide species. (Higher levels of efficiency can be obtained with multi-optic imaging systems.) The gamma-ray lens will achieve a resolution as good as 100 microns, independent of the final sensitivity. The combination of high spatial resolution and modest sensitivity will enable in vivo single photon emission imaging studies in small animals.

Pivovaroff, M. J.↗

Optical Metrology for the Segmented Optics on the Constellation-X Spectroscopy X-Ray Telescope

We present the metrology requirements and metrology implementation necessary to prove out the reflector technology for the Constellation X(C-X) spectroscopy X-ray telescope (SXT). This segmented, 1.6m diameter highly nested Wolter-1 telescope presents many metrology and alignment challenges. In particular, these mirrors have a stringent imaging error budget as compared to their intrinsic stiffness; This is required for Constellation-X to have sufficient effective area with the weight requirement. This has implications for the metrology that can be used. A variety of contract and noncontact optical profiling and interferometric methods are combined to test the formed glass substrates before replication and the replicated reflector segments.The reflectors are tested both stand-alone and in-situ in an alignment tower.Some of these methods have not been used on prior X-ray telescopes and some are feasible only because of the segmented approach used on the SXT. Methods discussed include high precision coordinate measurement machines using very low force or optical probe axial interferometric profiling azimuthal circularity profiling and use of advanced null optics such as conical computer generated hologram (CGHs).

Content, David↗

[Development of Nanotechnology for X-Ray Astronomy Instrumentation]

This Research Grant provides support for development of nanotechnology for x-ray astronomy instrumentation. MIT has made significant progress in several development areas. In the last year we have made considerable progress in demonstrating the high-fidelity patterning and replication of x-ray reflection gratings. We developed a process for fabricating blazed gratings in silicon with extremely smooth and sharp sawtooth profiles, and developed a nanoimprint process for replication. We also developed sophisticated new fixturing for holding thin optics during metrology without causing distortion. We developed a new image processing algorithm for our Shack-Hartmann tool that uses Zernike polynomials. This has resulted in much more accurate and repeatable measurements on thin optics.

Schattenburg, Mark L.↗

Three stages in the evolution of the genetic code

A diversification of the genetic code based on the number of codons available for the proteinous amino acids is established. Three groups of amino acids during evolution of the code are distinguished. On the basis of their chemical complexity those amino acids emerging later in a translation process are derived. Codon number and chemical complexity indicate that His, Phe, Tyr, Cys and either Lys or Asn were introduced in the second stage, whereas the number of codons alone gives evidence that Trp and Met were introduced in the third stage. The amino acids of stage 1 use purine-rich codons, while all the amino acids introduced in the second stage, in contrast, use pyrimidines in the third position of their codons. A low abundance of pyrimidines during early translation is derived. This assumption is supported by experiments on non-enzymatic replication and interactions of hairpin loops with a complementary strand. A back extrapolation concludes a high purine content of the first nucleic acids, which gradually decreased during their evolution. Amino acids independently available from prebiotic synthesis were thus correlated to purine-rich codons. Implications on the prebiotic replication are discussed also in the light of recent codon usage data.

Review↗

What Information Theory Says about Bounded Rational Best Response

Probability Collectives (PC) provides the information-theoretic extension of conventional full-rationality game theory to bounded rational games. Here an explicit solution to the equations giving the bounded rationality equilibrium of a game is presented. Then PC is used to investigate games in which the players use bounded rational best-response strategies. Next it is shown that in the continuum-time limit, bounded rational best response games result in a variant of the replicator dynamics of evolutionary game theory. It is then shown that for team (shared-payoff) games, this variant of replicator dynamics is identical to Newton-Raphson iterative optimization of the shared utility function.

Wolpert, David H.↗

Initial Development of a Metric to Describe the Level of Safety Associated with Piloting an Aircraft with Synthetic Vision Systems (SVS) Displays

Synthetic Vision Systems (SVS) displays provide pilots with a continuous view of terrain combined with integrated guidance symbology in an effort to increase situation awareness (SA) and decrease workload during operations in Instrument Meteorological Conditions (IMC). It is hypothesized that SVS displays can replicate the safety and operational flexibility of flight in Visual Meteorological Conditions (VMC), regardless of actual out-the-window (OTW) visibility or time of day. Significant progress has been made towards evolving SVS displays as well as demonstrating their ability to increase SA compared to conventional avionics in a variety of conditions. While a substantial amount of data has been accumulated demonstrating the capabilities of SVS displays, the ability of SVS to replicate the safety and operational flexibility of VMC flight performance in all visibility conditions is unknown to any specific degree. In order to more fully quantify the relationship of flight operations in IMC with SVS displays to conventional operations conducted in VMC, a fundamental comparison to current day general aviation (GA) flight instruments was warranted. Such a comparison could begin to establish the extent to which SVS display concepts are capable of maintaining an "equivalent level of safety" with the round dials they could one day replace, for both current and future operations. A combination of subjective and objective data measures were used to quantify the relationship between selected components of safety that are associated with flying an approach. Four information display methods ranging from a "round dials" baseline through a fully integrated SVS package that includes terrain, pathway based guidance, and a strategic navigation display, were investigated in this high fidelity simulation experiment. In addition, a broad spectrum of pilots, representative of the GA population, were employed for testing in an attempt to enable greater application of the results and determine if "equivalent levels of safety" are achievable through the incorporation of SVS technology regardless of a pilot's flight experience.

Bartolone, Anthony P.↗