Search NASA⌕ Search

SEARCH · Search NASA

Results for “SCINTILLATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

The Parabolic Wave Equation Generalized to a Spatially Varying Plasma in a Vertical Magnetic Field

This report walks through the process of deriving the wave equation for a vertical wave being propagated through a spatially varying plasma in a vertical magnetic field. Additionally, this report shows how to derive the index of refraction of the plasma corresponding to three different modes of the vertical magnetic field. Finally, this paper briefly explores the next steps planned to successfully simulate and test the equations in a pre-existing phase screen scintillation code.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Luminescence properties of europium doped and sodium co-doped LiCaAlF 6

This paper serves as a literature review of scintillating thermal neutron detectors, along with a study of sodium and europium doped LiCaAlF 6 (LiCAF) polycrystalline material. A set of polycrystalline LiCAF material was synthesized with 2 molar percent of europium (Eu 2+ ) and co-doped with 0, 1, and 2 molar percent of sodium (Na + ), with a stoichiometric synthesis approach in a glassy-carbon crucible. The quantum yield and photoluminescence spectrum at room temperature was analyzed. For the first time, we have demonstrated that Na-co-doping directly alters the quantum yield. The quantum yield for LiCAF:Eu 2+ , with 0, 1, and 2 molar percent of sodium (Na + ) was 0.578, 0.635, and 0.580, respectively. The photoluminescence (PL) spectrum was also analyzed for all samples. The photo-luminescence excitation (PLE) spectrum showed a maximum at 300 nm, while the emission spectrum showed a maximum at 370 nm, corresponding to the Eu 2+ 5d-4f transitions.

36 MATERIALS SCIENCE↗

Search for Fast Magnetic Monopoles with NOvA Far Detector

The NOvA experiment at Fermilab consists of two functionally identical liquid scintillator detectors called near detector and far detector to study neutrino oscillations using GeV-scale neutrinos from the Fermilab NuMI beam. Due to its location close to the earth’s surface, surface area of over 4,000 $(m^{2})$, and little overburden, the NOvA far detector is sensitive to an extensive range of magnetic monopole masses and velocities. With the help of the far detector, we are looking for signals of relic monopoles in the cosmic rays flux that might have been produced in the early universe. We have developed the data-driven trigger(DDT), a robust trigger algorithm optimized for continuously searching the magnetic monopole-like patterns in the live data. Due to the surface proximity of the far detector, the major challenge for this analysis at the offline level is the rejection of cosmic ray background in the collected data. In this talk, I will present the status of the search for fast-moving magnetic monopoles using the data collected by the NOvA far detector.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Neutrino oscillation prospects with a dual-baseline beam from BNL to SNOLAB and SURF

The Electron-Ion Collider (EIC) is a next-generation accelerator primarily designed to study the internal structure of nucleons through high-precision electron-hadron collisions. In this work, we explore the feasibility of employing a 1 MW fraction of the EIC proton beam to generate a high-intensity GeV-scale neutrino beam for long-baseline oscillation studies. We have simulated proton-target interactions and optimize the resulting neutrino fluxes for water-based liquid scintillator (WbLS) detectors located at distinct baselines of 900 km and at 2900 km. Oscillation analyses performed with GLoBES show that extended baselines allow access to multiple oscillation maxima, significantly enhancing sensitivity to leptonic CP violation. The study also examines the interplay between matter effects and the intrinsic CP violating phase in shaping observable asymmetries. We note that simplified systematics and no backgrounds are used in this analysis to establish the baseline physics potential. These results suggest that the EIC proton beam could provide a novel and complementary source for precision neutrino physics, extending the scientific reach of the EIC program.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Quantitative Comparisons of Image Quality for Flash X-Ray Detectors

Due to X-rays’ ability to penetrate materials, flash X-ray radiography can be used for high-speed measurements where direct optical access is not possible. Choice of detector has a pronounced impact on resulting image quality. Four different detector systems were evaluated with a 450kVp flash source to quantitatively compare image quality metrics. The scintillating digital detector had less image noise than the three different storage phosphor computed radiography detectors across all transmission levels, but lacked the spatial resolution of the computed radiography detectors. For the screens tested here, the HPX-DR digital system had the highest signal to noise ratio of 68.24 and contrast to noise ratio of 35.53, but had the lowest spatial resolution, resolving 2.5 line pairs per millimeter at 1.78% contrast. At a value of 37.59, the Flex GP imaging plate had a signal to noise value above its storage phosphor counterparts under a 450kVp flash source. For radiographic setups typically used for dynamic experiments, the Flex XL Blue and Flex HR detectors had signal to noise ratios of 18.44 and 26.56 respectively. The highest resolved spatial frequencies of the Flex GP, Flex XL Blue, and Flex HR with the flash source are 3.85, 5.00, and 3.85 line pairs per millimeter, respectively. In conclusion, the Flex GP detector had the best combination of signal to noise ratio, contrast to noise ratio, and spatial resolution under a flash source.

computed radiography↗

Analysis of fast-ion losses measured in MAST-U via infrared thermography and a Fast Ion Loss Detector

Fast-ion losses need to be monitored to avoid damage to plasma facing components. In existing experimental devices, the scintillator-based fast-ion loss detector (FILD) is the most advanced diagnostic for measuring fast-ion losses. However, FILDs provide only local information about the losses. Infrared (IR) thermography can be used as a complementary tool for more global monitoring of the deposition of fast-ion losses on the wall, at the expense of no velocity-space resolution. IR cameras measure the temperature of the plasma facing components. This measurement, determined by a combined effect of the thermal plasma, radiation, neutrons and fast-ion losses, can be decomposed to infer the fast-ion load on the tokamak wall. In this manuscript, a workflow to estimate fast-ion losses via IR thermography is applied to the MAST-U spherical tokamak, using a 1D approximation to extract the experimental heat flux on the FILD front face from IR data. To numerically estimate the different contributions to this total heat flux, the field-line tracing environment SMITER is used to calculate the thermal plasma contribution, the orbit-following Monte-Carlo code ASCOT to estimate the fast-ion losses, and bolometry measurements for the radiation. To validate the workflow, two discharges, L-mode plasmas with low MHD activity, were executed using on and off-axis beams, respectively. The experimentally and numerically estimated heat flux are of the same order of magnitude for the on-axis heated scenario, with a strong dependence of the estimated fast-ion losses contribution on the fit to the kinetic profiles used as input. This is also true for the off-axis heated scenario, where the total numerically estimated heat flux is 2.1 or 1.3 times higher than the maximum experimentally estimated heat flux, depending on the ASCOT input used.

FILD↗

Beta-delayed gamma spectra compilation and analysis following the thermal-neutron induced fission of 235 U, 239,241 Pu

The integral gamma and electron spectra emitted by fission products, also known as delayed gamma and electron spectra, were measured at Oak Ridge National Laboratory in the 1970s for the thermal-neutron induced fission of 235 U and 239,241 Pu. Scintillator detectors were used to measure these spectra, data used later on to obtain decay heat values - that is, the spectra mean values per unit time as function of time - work that was published in the Nuclear Science and Technology journal; the spectral data, however, was only published in laboratory reports. Here, in this work, we analyze the gamma spectra data using modern methods and nuclear databases to reveal the signature of individual fission products as well as to gauge the performance of the ENDF/B-VIII.0 decay data sub-library, concluding about possible future enhancements in predictive capabilities.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The data acquisition system of the LZ dark matter detector: FADR

The Data Acquisition System (DAQ) for the LUX-ZEPLIN (LZ) dark matter detector is described. The signals from 745 PMTs, distributed across three subsystems, are sampled with 100-MHz 32-channel digitizers (DDC-32s). A basic waveform analysis is carried out on the on-board Field Programmable Gate Arrays (FPGAs) to extract information about the observed scintillation and electroluminescence signals. This information is used to determine if the digitized waveforms should be preserved for offline analysis. The system is designed around the Kintex-7 FPGA. In addition to digitizing the PMT signals and providing basic event selection in real time, the flexibility provided by the use of FPGAs allows us to monitor the performance of the detector and the DAQ in parallel to normal data acquisition. Furthermore, the hardware and software/firmware of this FPGA-based Architecture for Data acquisition and Realtime monitoring (FADR) are discussed and performance measurements are described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Power over fiber development for HEP detectors

Power-over-Fiber (PoF) technology has been used extensively in settings where high voltages require isolation from ground and electromagnetic isolation is critical. In cryogenic environments, PoF offers a reliable power transmission technology, leveraging optical fibers to transfer power with minimal system degradation. PoF technology excels in maintaining low noise levels and isolation when delivering power to sensitive electronic systems operating in extreme temperature ranges and high voltage environments. Here, in a novel application of PoF for a HEP detector, power is provided to photon detector modules located on a surface at ~300 kV with respect to ground in the planned DUNE experiment. This summary paper of the PoF talk at the 16th PISA Meeting on Advanced Detectors highlights the R&D effort of PoF in extreme conditions and underscores its capacity to revolutionize power delivery and management in critical applications offering a dependable solution with low noise, optimal efficiency, and superior isolation. The DUNE (Abi et al., 2020) experiment will soon deploy large liquid argon (LAr) time projection chambers (TPC) to detect neutrino interactions and other particle physics phenomena. In addition to the particle tracking provided by the TPC, photon detectors, powered by a first ever PoF system, in the cryostat will leverage the high scintillation light yield of LAr to provide crucial timing and additional calorimetric information.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Rate-induced aging effects on Parallel-Plate Avalanche Counter (PPAC) caused by heavy ion beams

The Facility for Rare Isotope Beams (FRIB) is one of the premier scientific user facilities for nuclear science with radioactive beams, capable of producing most (approximately 80%) of the isotopes expected to exist, from oxygen to uranium, at energies up to 200 MeV/u. With the increase in beam power from the present 10 kW to the planned 400 kW, FRIB experiments are about to enter a new era. An unprecedented rate capability as well as stable performance of all the planned instrumentation intended for beam diagnostics and beam tuning is required at the expected high beam intensities (> 1 MHz). A summary of aging phenomena at high heavy-ion beam rates observed in the Advanced Rare Isotope Separator (ARIS) detectors for beam diagnostics, including Parallel Plate Avalanche Counters (PPAC) and plastic scintillation for time-of-flight measurements, is discussed. Current research and development project to mitigate rate-induced aging are presented.

Aging effects↗

Towards a new generation of solid total-energy detectors for neutron-capture time-of-flight experiments with intense neutron beams

Challenging neutron-capture cross-section measurements of small cross sections and samples with a very limited number of atoms require high-flux time-of-flight facilities. In turn, such facilities need innovative detection setups that are fast, have low sensitivity to neutrons, can quickly recover from the so-called γ-flash, and offer the highest possible detection sensitivity. In this paper, we present several steps towards such advanced systems. Specifically, we describe the performance of a high-sensitivity experimental setup at CERN n_TOF EAR2. It consists of nine sTED detector modules in a compact cylindrical configuration, two conventional used large-volume C 6 D 6 detectors, and one LaCl 3 (Ce) detector. The performance of these detection systems is compared using 93 Nb(n, γ) data. We also developed a detailed G EANT small4 Monte Carlo model of the experimental EAR2 setup, which allows for a better understanding of the detector features, including their efficiency determination. This Monte Carlo model has been used for further optimization, thus leading to a new conceptual design of a γ detector array, STAR, based on a deuterated-stilbene crystal array. Finally, the suitability of deuterated-stilbene crystals for the future STAR array is investigated experimentally utilizing a small stilbene-d12 prototype. The results suggest a similar or superior performance of STAR with respect to other setups based on liquid-scintillators, and allow for additional features such as neutron-gamma discrimination and a higher level of customization capability.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Geant4 simulations of sampling and homogeneous hadronic calorimeters with dual readout for future colliders

Calorimeters with dual readout measure both scintillation and Cherenkov light produced in their active media. They offer improvements in energy resolution and, therefore, have become increasingly interesting due to the need for precision jet measurements at Higgs factories. Furthermore, this paper presents GEANT4 simulations of single-particle responses in sampling and homogeneous calorimeters, and demonstrates the effect of inclusion of Cherenkov light in the reconstruction of energies.

Detector modeling and simulations↗

Ground calibration and in-flight commissioning of the Gamma-Ray and Neutron Spectrometer (GRNS) for NASA’s Psyche mission

NASA's Psyche spacecraft is currently enroute to the asteroid 16 Psyche, where it will perform an orbital investigation focused on determining the nature of the asteroid. A key part of this investigation is measurements of elemental composition to determine if the asteroid is rich in iron-nickel metal. To that end, the Psyche spacecraft payload includes a Gamma-Ray and Neutron Spectrometer (GRNS). GRNS is composed of two subsystems; a Gamma-Ray Spectrometer (GRS) with a high-purity germanium γ-ray sensor surrounded by a borated plastic scintillator Anti-Coincidence Shield (ACS), and a Neutron Spectrometer (NS) with three 3 He-filled gas proportional counters that are sensitive to different neutron energy regimes. We describe results from the pre-launch calibration campaign, along with early in-flight results from post-launch instrument commissioning. The information detailed here is focused on providing future users of GRNS data with the information needed to properly interpret the observations from the instrument.

Peplowski, Patrick N. [Johns Hopkins Univ., Baltim↗

Performance measurements of the electromagnetic calorimeter and readout electronics system for the DarkQuest experiment

Here, this paper presents performance measurements of a new readout electronics system based on silicon photomultipliers for the PHENIX electromagnetic calorimeter. Installation of the lead-scintillator Shashlik style calorimeter into the SeaQuest/SpinQuest spectrometer has been proposed to broaden the experiment’s dark sector search program, an upgrade known as DarkQuest. The calorimeter and electronics system were subjected to testing and calibration at the Fermilab Test Beam Facility. Detailed studies of the energy response and resolution, as well as particle identification capabilities, were performed. The background rate in the actual experimental environment was also examined. The system is found to be well-suited for a dark sector search program on the Fermilab 120 GeV proton beamline.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Temperature-dependent calibration procedures for the silicon photomultiplier readout of the cosmic ray veto detector for the Mu2e experiment

The cosmic ray veto detector for the Mu2e experiment consists of scintillation bars embedded with wavelength-shifting fibers and read out by silicon photomultipliers (SiPMs). Here, in this manuscript, the calibration procedures of the SiPMs are described including corrections for the temperature dependence of their light yield. These corrections are needed as the SiPMs are not kept at a constant temperature due to the complexity and cost of implementing a cooling system on such a large detector. Rather, it was decided to monitor the temperature to allow the appropriate corrections to be made. The SiPM temperature dependence has been measured in a dedicated experiment and the calibration procedures were validated with data from production detectors awaiting installation at Fermilab.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A monolithic antineutrino detector for non-intrusive reactor monitoring

Recent advances in organic detection media have found applications in reactor antineutrino physics. One example is the Precision Oscillation and Spectrum Experiment (PROSPECT), which leveraged pulse-shape sensitivity to enable a successful surface deployment at the High Flux Isotope Reactor (HFIR), achieving a signal to background of 4:1. PROSPECT utilized almost 4 tonnes of 6 Li-doped pulse-shape sensitive liquid scintillator in a two-dimensional segmented array. It used a combination of pulse-shape sensitivity and position sensitivity via segmentation to reduce the most prominent form of correlated background for surface detectors — cosmogenic fast neutrons. These new liquids may enable detector designs that bring additional tools for reducing backgrounds while reducing engineering complexity. In this paper, we present an investigation into a detector design that exploits properties of these liquids by maximizing spectral and pulse-shape sensitivity via highly efficient photon detection. The detector utilizes photomultiplier tubes (PMTs) placed at the top and bottom of a right cylinder, with highly reflective white walls. This design sacrifices some position sensitivity for maximal photon efficiency. In conclusion, the design choice has consequences for the identification of the background and antineutrino sensitivity, which we examine.

Pulse shape↗

Characterizing the Experiment for Calibration with Uranium (Excalibur) neutron source for use in warhead verification

Neutron sources can play a variety of roles in warhead verification. For transmission radiography, a source of directed high energy neutrons is required, while for applications to detect fissile isotopes, sub-MeV neutrons are preferred. The Excalibur (Experiment for Calibration with Uranium) neutron source has been built and used in a variety of verification-related experiments. Excalibur is based on a commercial deuterium-tritium neutron generator specified and measured to be capable of producing 14 MeV neutrons at rates of up to 8.2 × 10 8 neutrons/s. Here, the generator is enclosed in a carbon-steel 32" diameter, 23.62" high carbon-steel cylinder that moderates the mean neutron energy to under 500 keV. This, in turn, is encased in 5%-borated polyethylene such that the entire assembly is a 48" x 48" box that is 30" tall. For radiographic applications, a narrow, tapered channel in the steel and polyethylene allows 14 MeV neutrons to stream directly from the generator to a test object. Its collimating capability is demonstrated by measuring the neutron flux profile. In the moderated mode of operation, the generator is fully enclosed in the steel, but a large section of the polyethylene is removed, providing a flux of sub-MeV neutrons from a wide range of angles. Neutron angular and spectral measurements using both a nested neutron spectrometer and a commercial liquid scintillator coupled with a 3 He detector show the expected softer neutron spectrum in moderated mode in good agreement with MCNP6 calculations. The gamma-ray spectrum from Excalibur is also in good agreement with MCNP modeling. Based on these findings, the future application of Excalibur in its two configurations is discussed.

Fissile material detection↗

Design and commissioning of the Correlated Gamma-Neutron Array for sCattering (CoGNAC)

The Correlated Gamma-Neutron Array for sCattering (CoGNAC) is a dual $n$-$γ$ detector array fielded at the Weapons Neutron Research facility at the Los Alamos Neutron Science Center. Here, the detector array utilizes elpasolite detectors and liquid scintillators to perform measurements of neutron elastic and inelastic scattering cross sections and emitted particle angular distributions. This manuscript details the design and experimental setup of CoGNAC as well as some of the preliminary studies performed to select the elpasolite detectors deployed in the array. Examples of the analysis methods available to CoGNAC are given in the context of past CoGNAC measurements of neutron scattering reactions on 28 Si and 56 Fe.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗