Search NASA⌕ Search

SEARCH · Search NASA

Results for “SCINTILLATION COUNTING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Performance of coincidence-based PSD on LiF/ZnS Detectors for Multiplicity Counting

Abstract: Mass accountancy measurement is a nuclear nonproliferation application which utilizes coincidence and multiplicity counters to verify special nuclear material declarations. With a well-designed and efficient detector system, several relevant parameters of the material can be verified simultaneously. 6LiF/ZnS scintillating sheets may be used for this purpose due to a combination of high efficiency and short die-away times in systems designed with this material, but involve choices of detector geometry and exact material composition (e.g., the addition of Ni-quenching in the material) that must be optimized for the application. Multiplicity counting for verification of declared nuclear fuel mass involves neutron detection in conditions where several neutrons arrive in a short time window, with confounding gamma rays. This paper considers coincidence-based Pulse-Shape Discrimination (PSD) techniques developed to work under conditions of high pileup, and the performance of these algorithms with different detection materials. Simulated and real data from modern LiF/ZnS scintillator systems are evaluated with these techniques and the relationship between the performance under pileup and material characteristics (e.g., neutron peak width and total light collection efficiency) are determined, to allow for an optimal choice of detector and material.

Robinson, Sean M.↗

Methodology for the neutron time of flight measurement of 120-GeV proton-induced reactions on a thick copper target

Our methodology for the time-of-flight measurement of the neutron energy spectrum for a high-energy proton-beam-induced reaction was established at the Fermilab Test Beam Facility of the Fermi National Accelerator Laboratory. The 120-GeV proton beam with 3 × 10 5 protons/spill was prepared for event-by-event counting of incident protons and emitted neutrons for time-of-flight energy determination. An NE213 organic liquid scintillator (12.7 cm in diameter by 12.7 cm in length) was employed with a veto plastic scintillator and a pulse-shape discrimination technique to identify neutrons. Raw waveforms of NE213, veto and beam detectors were recorded to discriminate the effects of multi-proton beam events by considering different time windows. The neutron energy spectrum ranging from 10 to 800 MeV was obtained for a 60-cm-long copper target at 90° with respect to the beam axis. Finally our obtained spectrum was consistent with that deduced employing the conventional unfolding technique as well as that obtained in a 40-GeV/c thin-target experiment.

120-GeV proton↗

Development of an alpha/beta/gamma detector for radiation monitoring

For radiation monitoring at the site of nuclear power plant accidents such as Fukushima Daiichi, radiation detectors not only for gamma photons but also for alpha and beta particles are needed because some nuclear fission products emit beta particles and gamma photons and some nuclear fuels contain plutonium that emits alpha particles. We developed a radiation detector that can simultaneously monitor alpha and beta particles and gamma photons for radiation monitoring. The detector consists of three-layered scintillators optically coupled to each other and coupled to a photomultiplier tube. The first layer, which is made of a thin plastic scintillator (decay time: 2.4 ns), detects alpha particles. The second layer, which is made of a thin Gd{sub 2}SiO{sub 5} (GSO) scintillator with 1.5 mol.% Ce (decay time: 35 ns), detects beta particles. The third layer made of a thin GSO scintillator with 0.4 mol.% Ce (decay time: 70 ns) detects gamma photons. By using pulse shape discrimination, the count rates of these layers can be separated. With individual irradiation of alpha and beta particles and gamma photons, the count rate of the first layer represented the alpha particles, the second layer represented the beta particles, and the third layer represented the gamma photons. Even with simultaneous irradiation of the alpha and beta particles and the gamma photons, these three types of radiation can be individually monitored using correction for the gamma detection efficiency of the second and third layers. Our developed alpha, beta, and gamma detector is simple and will be useful for radiation monitoring, especially at nuclear power plant accident sites or other applications where the simultaneous measurements of alpha and beta particles and gamma photons are required.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

California GAMA Special Study. Development of a Capability for the Analysis of Krypton-85 in Groundwater Samples

A capability for the analysis of krypton-85 ( 85 Kr) in groundwater samples was developed at LLNL. Samples are collected by extracting gas from 2000-4000 L of groundwater at the well, yielding approximately 0.2 cm 3 STP krypton. Sample collection takes 1 to 4 hours. Krypton is purified in the laboratory using a combination of molecular sieve and activated charcoal traps, and transferred to a liquid scintillation vial. The 85 Kr activity is measured by liquid scintillation on a Quantulus 1220 liquid scintillation counter from PerkinElmer. The detection limit for a typical 0.2 cm 3 Kr sample size is 11% of the present day activity in air, corresponding to the decay corrected activity in air in 1987. The typical measurement uncertainty is below 10% for recently recharged samples. Six groundwater samples were collected, purified and counted. 85 Kr was not detected in any of the samples counted at LLNL. 85 Kr was detected by the low level counting laboratory of Bern University in all samples between 1.5 and 6.6 decays per minute per cm 3 krypton, corresponding to decay corrected activities in air between 1971 and 1985. The new capability is an excellent complement to tritium-helium, expanding the existing suite of age dating tools available to the GAMA program ( 35 S, 3 H/ 3 He, 14 C and radiogenic helium). 85 Kr can replace 3 H/ 3 He in settings where 3 H/ 3 He ages are impossible to determine (for example where terrigenic helium overwhelms tritiogenic helium) and provides additional insight into travel time distributions in complex mixed groundwater systems.

54 ENVIRONMENTAL SCIENCES↗

Time Correlation Measurements of 252Cf Source Driven Fission Chains in Bare HEU Metal Assemblies

Passive multiplicity measurements of fissile metal assemblies are well established for measuring the multiplication, fissile content, and detection efficiency. In plutonium metal assemblies, most of the neutrons are unambiguously observed from fission chains because of the high spontaneous fission rate. However, uranium metal assemblies have low spontaneous fission rate such that the observed neutrons are a mixture of fission chain neutrons and cosmic-ray spallation neutrons. As a result, the multiplication, fissile content, and detection efficiency are difficult to measure without accurate quantification of the single neutron events unrelated to the fission chains. However, studying fission chains is simplified by knowing when each chain starts, which can be accomplished using a time-tagged active source such as a 252 Cf ionization chamber or a deuterium-tritium (D-T) neutron generator with an alpha detector. This paper presents time correlation measurements that have been performed with up to five 18 kg highly enriched uranium (HEU) storage castings and a 252 Cf ionization chamber placed near the center of each assembly. The measurements included liquid scintillators with pulse shape discrimination operating on the timescale of fission chains and 3 He proportional counters whose traditional use in multiplicity counting is well understood within a point-kinetics framework. Neutron time correlation distributions have been measured to characterize each assembly and are compared with the equivalent distributions collected passively.

252-Cf Ionization Chamber↗

Gamma-ray spectroscopy at MHz counting rates with a compact LaBr{sub 3} detector and silicon photomultipliers for fusion plasma applications

Gamma-ray spectroscopy measurements at MHz counting rates have been carried out, for the first time, with a compact spectrometer based on a LaBr{sub 3} scintillator and silicon photomultipliers. The instrument, which is also insensitive to magnetic fields, has been developed in view of the upgrade of the gamma-ray camera diagnostic for α particle measurements in deuterium-tritium plasmas of the Joint European Torus. Spectra were measured up to 2.9 MHz with a projected energy resolution of 3%-4% in the 3-5 MeV range, of interest for fast ion physics studies in fusion plasmas. The results reported here pave the way to first time measurements of the confined α particle profile in high power plasmas of the next deuterium-tritium campaign at the Joint European Torus.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of a large-area iQID imager for safeguards applications

Environmental sampling and sample analyses by the International Atomic Energy Agency is a key method for verifying declarations in international safeguards agreements. Quantitative Digital Autoradiography for Environmental Samples is a system developed by Pacific Northwest National Laboratory to examine environmental swipe samples (ESS) prior to subsequent, destructive analysis. This approach is passive and noninvasive for imaging beta and gamma emissions, which transmit through the plastic bags containing the ESS. Alpha particle imaging is also possible with different ESS containers. This technology is based on a portable, real-time, event-counting, high spatial resolution system called iQID (ionizing-radiation Quantum Imaging Detector), which is made from commercial, off-the-shelf components. This includes a scintillator in direct contact with a micro-channel plate image intensifier and a lens for imaging the intensified scintillation events onto a CCD/CMOS camera. The QDARES large-area iQID includes a fiber-optic taper coupled to the image intensifier which increases the imaging area to a ~100 cm square with a 105 mm x 105 mm taper. In this study, we describe new characterization results, including spatial resolution, energy response, minimum detectable activity for several isotopes, detector uniformity, and count-rate capability.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Prompt Photofission Neutron Detection in Depleted Uranium

The detection of prompt photofission neutrons during active interrogation is a strong indication of the presence of special nuclear materials. However, the high-energy photons used for interrogation create a very challenging radiation environment for the detection of prompt fission signatures. These challenges include detector saturation and pulse pile-up. Additionally, there is an elevated neutron background that further challenges the detection of prompt fission neutrons. This background is produced because of (γ, Xn) photonuclear reactions in the surrounding high-Z materials. Here, we demonstrate the detection of prompt photofission neutrons in these challenging environments. Depleted uranium (DU) and lead targets are interrogated with bremsstrahlung photons produced by a 9-MV electron linear accelerator. Fast neutrons are detected with trans-stilbene organic detectors, and scintillation pulses are analyzed using a previously developed and demonstrated artificial neural network system. We observe a 5 times higher photoneutron count rate when the lead target is replaced with the DU target. Additionally, we observe a difference in the photoneutron light-output distributions of lead and DU. Here, this difference in the measured distributions is due to the difference in the photoneutron-energy spectra; DU photoneutrons are emitted with (γ, n) and watt-energy spectra, whereas lead photoneutrons are emitted with only the (γ, n) spectrum.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A technique for verifying the input response function of neutron time-of-flight scintillation detectors using cosmic rays

An accurate interpretation of DD or DT fusion neutron time-of-flight (nTOF) signals from current mode detectors employed at the Z-facility at Sandia National Laboratories requires that the instrument response functions (IRF’s) be deconvolved from the measured nTOF signals. A calibration facility that produces detectable sub-ns radiation pulses is typically used to measure the IRF of such detectors. This work, however, reports on a simple method that utilizes cosmic radiation to measure the IRF of nTOF detectors, operated in pulse-counting mode. The characterizing metrics reported here are the throughput delay and full-width-at-half-maximum. This simple approach yields consistent IRF results with the same detectors calibrated in 2007 at a LINAC bremsstrahlung accelerator (Idaho State University). In particular, the IRF metrics from these two approaches and their dependence on the photomultipliers bias agree to within a few per cent. This information may thus be used to verify if the IRF for a given nTOF detector employed at Z has changed since its original current-mode calibration and warrants re-measurement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improved format for radiocardiographic data

Technique involves introduction of radioactive sample into antecubital vein. Scintillation crystal mounted in collimating housing views portion of right and left hearts. As radioactive sample passes through heart, counting rate is measured by crystal and recorded on strip chart. Data is insensitive to geometric effects and other parameters.

Dimeff, J.↗

Improved Lixiscope

Improved lixiscope utilizes fast-decay scintillators and multiple or curved microchannels to achieve high energy and spatial resolution as well as single-photon counting. New unit, with higher energy resolution, is intended for X-ray astronomy, although it could be applied terrestrially wherever a sensitive portable radiation spectrometer is required for 20-to-200-keV range.

Yin, L. I.↗

Degradation of 81 keV 133Xe Gamma-Rays into the 31 keV X-Ray Peak in CsI Scintillators

ABSTRACT Pacific Northwest National Laboratory uses beta-gamma coincidence detectors in a number of xenon sampling and/or measurement systems to enable simultaneous, sensitive measurements of 131Xe, 133Xe, 133mXe, and 135Xe for treaty monitoring applications. In recent years, a new style of beta-gamma detector was developed to improve upon the detector module used in the Automated Radioxenon Sampler/Analyzer. The results of an MCNP5 Monte Carlo simulation of the new detector cell are presented, with particular emphasis on the identification of an energy deposition sequence with the potential to introduce significant error into the detector efficiency calibration. This sequence occurs when an 81 keV gamma from 133Xe is absorbed in an inactive region of the CsI(Na) scintillator, followed by emission of a 31 keV x-ray from cesium (or possibly a 28.5 keV x-ray from iodine). These x-rays add excess counts into the 31 keV peak observed in the decay of 133Xe. The impact of this effect on different efficiency calibration techniques is discussed.

133Xe, CsI Scintillators↗

Development of Fast Measurement System of Neutron Emission Profile Using a Digital Signal Processing Technique in JT-60U

Neutron emission profiles are routinely measured in JT-60U Tokamak. Stinbene neuron detectors (SNDs), which combine a Stilbene organic crystal scintillation detector (Stilbene detector) with an analog neutron-gamma pulse shape discrimination (PSD) circuit, have been used to measure neutron flux efficiently. Although the SND has many advantages as a neutron detector, the maximum count rate is limited up to {approx}1x 10{sup 5} counts/s due to the dead time of the analog PSD circuit. To overcome this issue, a digital signal processing (DSP) system using a Flash-ADC has been developed. In this system, anode signals from the photomultiplier of the Stilbene detector are fed to the Flash ADC and digitized. Then, the PSD between neutrons and gamma-rays are performed using software. The photomultiplier tube is also modified to suppress and correct gain fluctuation of the photomultiplier. The DSP system has been installed in the center channel of the vertical neutron collimator system in JT-60U and applied to measurements of neutron flux in JT-60U experiments. Neutron flux are successfully measured with count rate up to {approx}1x 10{sup 6} counts/s without the effect of pile up of detected pulses. The performance of the DSP system as a neutron detector is demonstrated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Generic Isotope Identification Approach for nuclear instrumentation

Isotope identification is generally done from spectra from high intrinsic resolution such as germanium. A lot of approaches are proposed in the literature. Most of them are not efficient with poor energy resolution detectors such as non-loaded scintillators. The proposed approach is a new isotope identification principle to deal with the overall range of nuclear detectors. The proposed method allows the identification of isotopes using detectors with poor intrinsic resolution and lower counting than the existing techniques. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron Rodeo Phase II Final Report

The ability to perform nondestructive assay (NDA) of fresh fuel assemblies with high precision in reasonable measurement times is significant for nuclear nonproliferation and safeguards. The current methodology used by the International Atomic Energy Agency (IAEA) for NDA of fresh fuel assemblies involves a He-3 based Uranium Neutron Collar (UNCL) system, which is an active coincidence counting system designed to measure time-correlated neutron doubles from induced fissions within the assembly. The UNCL system provides an easily implementable process of quantifying the 235 U linear density of the fresh fuel assemblies; however, operational limitations of the UNCL include long assay times and adverse sensitivity to poisoned assemblies. This has engendered investigation in alternative detector materials for fast-neutron counting to rectify some of these current limitations in the UNCL. The potential improvements of using fast-neutron organic scintillators (e.g. liquid scintillators, stilbene, PSDcapable plastics, etc.) was compared directly to the original Uranium Neutron Collar (UNCL) in-detail during the initial Advanced Neutron Detection Technology Rodeo. The simulation results showed that these alternative detector materials can provide an improvement in the assay time required to reach a suitable precision due to both their lower sensitivity to the interrogation source neutrons (i.e. AmLi neutrons) and their inherently shorter coincidence gate widths. The IAEA has developed a liquid scintillator-based Fast-Neutron Collar (FNCL) as a potential replacement system for the UNCL.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Cosmic ray scintillations in the frequency range from 0.00001 to 0.01 Hz

Power spectra of the flux variations in cosmic rays of energy greater than a few GeV are presented. The data were obtained at balloon altitudes (40-45 km) from two scintillation-type detectors flown for six hours from Palestine, Texas, on November 4, 1972. The large area detectors had effective count rates up to 2000 cps setting the Poisson noise level in the power spectra of the relative fluctuations at 0.001/Hz. The analysis was made on the singles rate of each of the counters as well as on the coincidence rates between them. In all cases, the spectra between 0.0001 and 0.002 Hz are power laws in frequency of the form f to the exponent negative gamma, where gamma is between 1.5 and 2.0. No significant peaks in the range 0.0001 to 0.01 Hz are observed.

Gehrels, N.↗

Alkali Halide Microstructured Optical Fiber for X-Ray Detection

Microstructured optical fibers containing alkali halide scintillation materials of CsI(Na), CsI(Tl), and NaI(Tl) are presented. The scintillation materials are grown inside the microstructured fibers using a modified Bridgman-Stockbarger technique. The x-ray photon counts of these fibers, with and without an aluminum film coating are compared to the output of a collimated CdTe solid state detector over an energy range from 10 to 40 keV. The photon count results show significant variations in the fiber output based on the materials. The alkali halide fiber output can exceed that of the CdTe detector, dependent upon photon counter efficiency and fiber configuration. The results and associated materials difference are discussed.

DeHaven, S. L.↗

Ternary cadmium sulphide selenide quantum dots as new scintillation materials

Monodisperse, highly luminescent, zinc blende, cadmium sulphide selenide (CdS{sub x}Se{sub 1-x}, x=mole fraction of sulphur) quantum dots (QDs) were prepared in gram scales in the particle size range 2?6-4?3 nm. With the varying S and Se contents, emission wavelengths of CdS{sub x}Se{sub 1-x} QDs were tuned from 439 to 581 nm (?exc.=370 nm). QDs were well dispersed in organic solvents and optically transparent plastic scintillators made with up to 10 wt-%QDs in polyvinyltoluene (PVT) were prepared. The result from alpha particle detection indicated the wavelengths match with the sensitivity of the photomultiplier tube. Pulse height peaks of CdS{sub x}Se{sub 1-x} with the wavelength of emission from 439 to 482 nm, appeared around 0?35 (channel no./amplifier gain), with different photon counts. No pulse height peak was observed with QDs that emitted at 505 nm or longer wavelengths. Under studied conditions, CdS0?95Se0?05 was found to be the most efficient scintillator.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗