Search NASA⌕ Search

SEARCH · Search NASA

Results for “SIGNAL GENERATOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Apparatus and method for determining the mass density of a filament

A method and apparatus for determining the mass density of a moving filament is provided. The method includes the steps of providing a filament across two supports, tensioning the filament, inducing a vibration into the filament segment between the supports, reinforcing the vibration using an amplified feedback signal, detecting the vibrational frequency data, processing the data using a fast-fourier transform analysis, and then displaying the frequency. The use of the feedback signal results in a self-tuning resonant loop. Open loop versions may also be used. The apparatus includes a base supporting a fixed support and a transducer which in turn supports a moveable support. The transducer vibrates the moveable support transversely to the direction of travel of the filament, thereby inducing a transverse vibrational mode. The output of the transducer is amplified and used to drive a second amplifier to produce a self-tuning resonant loop. In the open loop version a signal generator is used to drive the transducer through a frequency range, during which the amplitude peak is identified.

Hinkley, Jeffrey A.↗

Interaction of chronic reatine depletion and muscle unloading effects on postural and locomotor muscles

In this study, creatine depletion was induced separately and in combination with non-weight-bearing activity to determine if the response to lowering this metabolite would counter the MHC transitions expected from non-weight-bearing. Creatine depletion was induced by feeding rats a diet supplemented with the creatine analogue beta-guanidinopropionic acid (beta-GPA). Animals were fed a diet containing the creatine analogue for 68 days. Hindlimb non-weight-bearing in BS and NS animals was accomplished by tail suspension for the final 30 days of this period. Beta-GPA feeding lowered the creatine content of muscles sampled by 65%. Creatine depletion resulted in a 16% increase in citrate synthase activity in the soleus (SOL) and a 24% increase in the plantaris (PLN). In two postural muscles, the SOL and vastus intermedius (VI), tail suspension resulted in large decreases in the type I MHC expression and increases in type IIx and IIb MHCs. In two locomotor muscles, the PLN and medial gastrocnemius, type I MHC declined and type IIb increased with suspension. Creatine depletion did not prevent the suspension-induced decline in type I MHC in any of these muscles. The increase in type IIb MHC was either prevented or reduced by creatine depletion before and during suspension in the SOL, VI, and PLN. Creatine depletion alone resulted in small increases in type I and IIa MHCs in the two locomotor muscles, but it had no effect on the MHC profile of the postural muscles studied. These results indicate that the mechanical signal generated by the hindlimb non-weight-bearing state dominated over the metabolic stimulus of creatine depletion with respect to the primary adaptation involving a reduction in type I MHC.

Adams, Gregory R.↗

Phase-Locked Loop For Measurement Of Small And Large Delays

Electronic signal-generating and processing subsystem of ultrasonic inspection or measurement system consists mainly of variable-and-fixed-frequency, pulsed phase-locked loop (VFFPPLL) measuring phase shifts from 0 degrees to more than 360 degrees with accurancy of 0.112 degrees. VFFPPLL measures phase shifts between transmitted ultrasonic toneburst and its echo, thereby measuring ultrasonic-propagation delay. Used to determine strain in bolt or to track irregular surface of specimen being inspected ultrasonically.

Froggatt, Mark↗

A Novel Photonic Clock and Carrier Recovery Device

As data communication rates climb toward ten Gb/s, clock recovery and synchronization become more difficult, if not impossible, using conventional electronic circuits. We present in this article experimental results of a high speed clock and carrier recovery using a novel device called a photonic oscillator that we recently developed in our laboratory. This device is capable of recovering clock signals up to 70 GHz. To recover the clock, the incoming data is injected into the photonic oscillator either through the optical injection port or the electrical injection port. The free running photonic oscillator is tuned to oscillate at a nominal frequency equal to the clock frequency of the incoming data. With the injection of the data, the photonic oscillator will be quickly locked to clock frequency of the data stream while rejecting other frequency components associated with the data. Consequently, the output of the locked photonic oscillator is a continuous periodical wave synchronized with the incoming data or simply the recovered clock. We have demonstrated a clock to spur ratio of more than 60 dB of the recovered clock using this technique. Similar to the clock recovery, the photonic oscillator can be used to recover a high frequency carrier degraded by noise and an improvement of about 50 dB in signal-to-noise ratio was demonstrated. The photonic oscillator has both electrical and optical inputs and outputs and can be directly interfaced with a photonic system without signal conversion. In addition to clock and carrier recovery, the photonic oscillator can also be used for (1) stable high frequency clock signal generation, (2) frequency multiplication, (3) square wave and comb frequency generation, and (4) photonic phase locked loop.

Yao, X. Steve↗

High-Performance X-ray Detection in a New Analytical Electron Microscope

X-ray detection by energy-dispersive spectrometry in the analytical electron microscope (AEM) is often limited by low collected X-ray intensity (P), modest peak-to-background (P/B) ratios, and limitations on total counting time (tau) due to specimen drift and contamination. A new AFM has been designed with maximization of P. P/B, and tau as the primary considerations. Maximization of P has been accomplished by employing a field-emission electron gun, X-ray detectors with high collection angles, high-speed beam blanking to allow only one photon into the detector at a time, and simultaneous collection from two detectors. P/B has been maximized by reducing extraneous background signals generated at the specimen holder, the polepieces and the detector collimator. The maximum practical tau has been increased by reducing specimen contamination and employing electronic drift correction. Performance improvments have been measured using the NIST standard Cr thin film. The 0-3 steradian solid angle of X-ray collection is the highest value available. The beam blanking scheme for X-ray detection provides 3-4 times greater throughput of X-rays at high count rates into a recorded spectrum than normal systems employing pulse-pileup rejection circuits. Simultaneous X-ray collection from two detectors allows the highest X-ray intensity yet recorded to be collected from the NIST Cr thin film. The measured P/B of 6300 is the highest level recorded for an AEM. In addition to collected X-ray intensity (cps/nA) and P/B measured on the standard Cr film, the product of these can be used as a figure-of-merit to evaluate instruments. Estimated minimum mass fraction (MMF) for Cr measured on the standard NIST Cr thin film is also proposed as a figure-of-merit for comparing X-ray detection in AEMs. Determinations here of the MMF of Cr detectable show at least a threefold improvement over previous instruments.

Lyman, C. E.↗

Apparatus and Method for Determining the Mass Density of a Filament

A method and apparatus for determining the mass density of a moving filament is provided. The method includes the steps of providing a filament across two supports, tensioning the filament. inducing a vibration into the filament segment between the supports, reinforcing the vibration using an amplified feedback signal, detecting the vibrational frequency data. processing the data using a fast-fourier transform analysis. and then displaying the frequency. The use of the feedback signal results in a self-tuning resonant loop. Open loop versions may also be used. The apparatus includes a base supporting a fixed support and a transducer which in turn supports a moveable support. The transducer vibrates the moveable support transversely to the direction of travel of the filament, thereby inducing a transverse vibrational mode. The output of the transducer is amplified and used to drive a second amplifier to produce a self-tuning resonant loop. In the open loop version a signal generator is used to drive the transducer through a frequency range, during which the amplitude peak is identified.

Hinkley, Jeffrey A.↗

Experimental Simulation of Active Control With On-line System Identification on Sound Transmission Through an Elastic Plate

An adaptive control algorithm with on-line system identification capability has been developed. One of the great advantages of this scheme is that an additional system identification mechanism such as an additional uncorrelated random signal generator as the source of system identification is not required. A time-varying plate-cavity system is used to demonstrate the control performance of this algorithm. The time-varying system consists of a stainless-steel plate which is bolted down on a rigid cavity opening where the cavity depth was changed with respect to time. For a given externally located harmonic sound excitation, the system identification and the control are simultaneously executed to minimize the transmitted sound in the cavity. The control performance of the algorithm is examined for two cases. First, all the water was drained, the external disturbance frequency is swept with 1 Hz/sec. The result shows an excellent frequency tracking capability with cavity internal sound suppression of 40 dB. For the second case, the water level is initially empty and then raised to 3/20 full in 60 seconds while the external sound excitation is fixed with a frequency. Hence, the cavity resonant frequency decreases and passes the external sound excitation frequency. The algorithm shows 40 dB transmitted noise suppression without compromising the system identification tracking capability.

Source record↗

Development of a Sunspot Tracking System

Large solar flares produce a significant amount of energetic particles which pose a hazard for human activity in space. In the hope of understanding flare mechanisms and thus better predicting solar flares, NASA's Marshall Space Flight Center (MSFC) developed an experimental vector magnetograph (EXVM) polarimeter to measure the Sun's magnetic field. The EXVM will be used to perform ground-based solar observations and will provide a proof of concept for the design of a similar instrument for the Japanese Solar-B space mission. The EXVM typically operates for a period of several minutes. During this time there is image motion due to atmospheric fluctuation and telescope wind loading. To optimize the EXVM performance an image motion compensation device (sunspot tracker) is needed. The sunspot tracker consists of two parts, an image motion determination system and an image deflection system. For image motion determination a CCD or CID camera is used to digitize an image, than an algorithm is applied to determine the motion. This motion or error signal is sent to the image deflection system which moves the image back to its original location. Both of these systems are under development. Two algorithms are available for sunspot tracking which require the use of only one row and one column of image data. To implement these algorithms, two identical independent systems are being developed, one system for each axis of motion. Two CID cameras have been purchased; the data from each camera will be used to determine image motion for each direction. The error signal generated by the tracking algorithm will be sent to an image deflection system consisting of an actuator and a mirror constrained to move about one axis. Magnetostrictive actuators were chosen to move the mirror over piezoelectrics due to their larger driving force and larger range of motion. The actuator and mirror mounts are currently under development.

Taylor, Jaime R.↗

Effect of Increased Cyclic AMP Concentration on Muscle Protein Synthesis and Beta-Adrenergic Receptor Expression in Chicken Skeletal Muscle Cells in Culture

Analogies of epinephrine are known to cause hypertrophy of skeletal muscle when fed to animals. These compounds presumably exert their physiological action through interaction with the P-adrenergic receptor. Since the intracellular signal generated by the Beta-adrenergic receptor is cyclic AMP (cAMP), experiments were initiated in cell culture to determine if artificial elevation of cAMP by treatment with forskolin would alter muscle protein metabolism and P-adrenergic receptor expression. Chicken skeletal muscle cells after 7 days in culture were treated with 0.2-30 micrometers forskolin for a total of three days. At the end of the treatment period, both the concentration of cAMP and the quantity of myosin heavy chain (MHC) were measured. Concentration of cAMP in forskolin-treated cells increased up to 10-fold in a dose dependent manner. In contrast, the quantity of MHC was increased approximately 50% above control cells at 0.2 micrometers forskolin, but exhibited a gradual decline at higher levels of forskolin so that the quantity of MHC in cells treated with 30 micrometers forskolin was not significantly different from controls. Curiously, the intracellular concentration of cAMP which elicited the maximum increase in the quantity of MHC was only 40% higher than cAMP concentration in control cells.

Young, R. B.↗

Beta-Adrenergic Receptor Expression in Muscle Cells

beta-adrenergic receptor (bAR) agonists presumably exert their physiological action on skeletal muscle cells through the bAR. Since the signal generated by the bAR is cyclic AMP (cAMP), experiments were initiated in primary chicken muscle cell cultures to determine if artificial elevation of intracellular cAMP by treatment with forskolin would alter the population of bAR expressed on the surface of muscle cells. Chicken skeletal muscle cells after 7 days in culture were employed for the experiments because muscle cells have attained a steady state with respect to muscle protein metabolism at this stage. Cells were treated with 0-10 uM forskolin for a total of three days. At the end of the 1, 2, and 3 day treatment intervals, the concentration of cAMP and the bAR population were measured. Receptor population was measured in intact muscle cell cultures as the difference between total binding of [H-3]CGP-12177 and non-specific binding of [H-3]CGP-12177 in the presence of 1 uM propranolol. Intracellular cAMP concentration was measured by radioimmunoassay. The concentration of cAMP in forskolin-treated cells increased up to 10-fold in a dose dependent manner. Increasing concentrations of forskolin also led to an increase in (beta)AR population, with a maximum increase of approximately 50% at 10 uM. This increase in (beta)AR population was apparent after only 1 day of treatment, and the pattern of increase was maintained for all 3 days of the treatment period. Thus, increasing the intracellular concentration of cAMP leads to up-regulation of (beta)AR population. Clenbuterol and isoproterenol gave similar effects on bAR population. The effect of forskolin on the quantity and apparent synthesis rate of the heavy chain of myosin (mhc) were also investigated. A maximum increase of 50% in the quantity of mhc was observed at 0.2 UM forskolin, but higher concentrations of forskolin reduced the quantity of mhc back to control levels.

Young, Ronald B.↗

Beta-Adrenergic Receptor Population is Up-Regulated in Chicken Skeletal Muscle Cells Treated with Forskolin

Skeletal muscle hypertrophy is promoted by in vivo administration of beta-adrenergic receptor (betaAR) agonists. These compounds presumably exert their physiological action through the betaAR, and alterations in the population of betaAR could potentially change the ability of the cell to respond to the betaAR agonists. Since the intracellular chemical signal generated by the betaAR is cyclic AMP (cAMP), experiments were initiated in primary chicken muscle cell cultures to determine if artificial elevation of intracellular cAMP by treatment with forskolin would alter the population of functional betaAR expressed on the surface of muscle cells. Chicken skeletal muscle cells after 7 days in culture were employed for the experiments because muscle cells have attained a steady state with respect to muscle protein metabolism at this stage. Cells were treated with 0-10 microM forskolin for a total of three days. At the end of the 1, 2, and 3 day treatment intervals, the concentration of cAMP and the betaAR population were measured. Receptor population was measured in intact muscle cell cultures as the difference between total binding of [H-3]CGP-12177 and non-specific binding of [H-3]CGP-12177 in the presence of 1 microM propranolol. Intracellular cAMP concentration was measured by radioimmunoassay. The concentration of cAMP in forskolin-treated cells increased up to 10-fold in a dose dependent manner. Increasing concentrations of forskolin also led to an increase in betaAR population, with a maximum increase of approximately 50% at 10 microM. This increase in PAR population was apparent after only 1 day of treatment, and the pattern of increase was maintained for all 3 days of the treatment period. Thus, increasing the intracellular concentration of cAMP leads to up-regulation of betaAR population. The effect of forskolin on the quantity and apparent synthesis rate of the heavy chain of myosin (mhc) were also investigated. A maximum increase of 50% in the quantity of mhc was observed at 0.2 microM forskolin, but higher concentrations of forskolin reduced the quantity of mhc back to control levels.

Bridge, K. Y.↗

Testing Results of the X-38 Crew Return Vehicle GPS Receiver

The X-38 Crew Return Vehicle (CRV) utilizes a Space Integrated GPS/INS (SIGI) sensor to obtain navigation and attitude knowledge. Testing and analysis at the NASA Goddard Space Flight Center Guidance, Navigation, and Control's GPS Lab was conducted in order to validate the development of SIGI GPS receiver attitude firmware. The modifications to the International Space Station (ISS) SIGI receiver that were completed to meet the CRV requirements will be presented. The CRV is designed to be used as a life-boat in case of an emergency evacuation from the ISS. The need to return the ISS crew in a timely manner places challenging performance requirements on the SIGI sensor. This paper will summarize the performance of the SIGI GPS receiver for the CRV. The ability to track the GPS signals at any initial attitude and the performance of the SIGI GPS-only solution during reentry are detailed in this paper. A discussion regarding the use of the Global Satellite Systems GPS Signal Generator in testing the SIGI sensor will provide insight into the GPS validation process used at NASA Goddard.

Simpson, James↗

A Diagnostic Analysis of the Kennedy Space Center LDAR Network: Data Characteristics - 1

An analytic framework is developed in which to analyze climatological VHF (66 MHz) radiation measurements taken by the Kennedy Space Center Lightning Detection and Ranging (LDAR) network. A 19 month noise-filtered sample of LDAR observations is examined using this framework. It is found that the climatological impulsive VHF source density as observed by LDAR falls off approximately 10 dB every 71 km of ground range away from the network centroid (a 31 km e-folding scale). The underlying vertical distribution of impulsive VHF sources is approximately normally distributed with a mean altitude of 9 km and a standard deviation of 2.7 km; this implies that the loss of below-horizon sources has a negligible effect on column-integrated source densities within a 200 km ground range. At medium to far ranges, location errors are primarily radial and have a slightly asymmetric distribution whose standard deviation increases as r(exp 2). Error moments estimated from observed lightning are significantly higher than those from aircraft-based signal generator or analytic estimates. LDAR bulk flash detection efficiency is predicted to be above 90% to 94-113 km range from the network centroid and to fall below 10% at ranges greater than 200-240 km.

Boccippio, D. J.↗

Regulation of Osteoblast Survival by the Extracellular Matrix and Gravity

Spaceflight adversely affects the skeleton, posing a substantial risk to astronaut's health during long duration missions. The reduced bone mass observed in growing animals following spaceflight is due at least in part to inadequate bone formation by osteoblasts. Thus, it is of central importance to identify basic cellular mechanisms underlying normal bone formation. The fundamental ideas underlying our research are that interactions between extracellular matrix proteins, integrin adhesion receptors, cytoplasmic signaling and cytoskeletal proteins are key ingredients for the proper functioning of osteoblasts, and that gravity impacts these interactions. As an in vitro model system we used primary fetal rat calvarial cells which faithfully recapitulate osteoblast differentiation characteristically observed in vivo. We showed that specific integrin receptors ((alpha)3(beta)1), ((alpha)5(beta)1), ((alpha)8(betal)1) and extracellular matrix proteins (fibronectin, laminin) were needed for the differentiation of immature osteoblasts. In the course of maturation, cultured osteoblasts switched from depending on fibronectin and laminin for differentiation to depending on these proteins for their very survival. Furthermore, we found that manipulating the gravity vector using ground-based models resulted in activation of key intracellular survival signals generated by integrin/extracellular matrix interactions. We are currently testing the in vivo relevance of some of these observations using targeted transgenic technology. In conclusion, mechanical factors including gravity may participate in regulating survival via cellular interactions with the extracellular matrix. This leads us to speculate that microgravity adversely affects the survival of osteoblasts and contributes to spaceflight-induced osteoporosis.

Globus. Ruth K.↗

Simulated Performance of the Orbiting Wide-angle Light Collectors (OWL) Experiment

The Orbiting Wide-angle Light collectors (OWL) experiment is in NASA's mid-term strategic plan and will stereoscopically image, from equatorial orbit, the air fluorescence signal generated by airshowers induced by the ultrahigh energy (E greater than few x 10(exp 19) eV) component of the cosmic radiation. The use of a space-based platform enables an extremely large event acceptance aperture and thus will allow a high statistics measurement of these rare events. Detailed Monte Carlo simulations are required to quantify the physics potential of the mission as well as optimize the instrumental parameters. This paper reports on the results of the GSFC Monte Carlo simulation for two different, OWL instrument baseline designs. These results indicate that, assuming a continuation of the cosmic ray spectrum (theta approximately E(exp -2.75), OWL could have an event rate of 4000 events/year with E greater than or equal to 10(exp 20) eV. Preliminary results, based upon these Monte Carlo simulations, indicate that events can be accurately reconstructed in the detector focal plane arrays for the OWL instrument baseline designs under consideration.

Krizmanic, J. F.↗

Implementation of Adaptive Digital Controllers on Programmable Logic Devices

Much has been made of the capabilities of FPGA's (Field Programmable Gate Arrays) in the hardware implementation of fast digital signal processing (DSP) functions. Such capability also makes and FPGA a suitable platform for the digital implementation of closed loop controllers. There are myriad advantages to utilizing an FPGA for discrete-time control functions which include the capability for reconfiguration when SRAM- based FPGA's are employed, fast parallel implementation of multiple control loops and implementations that can meet space level radiation tolerance in a compact form-factor. Other researchers have presented the notion that a second order digital filter with proportional-integral-derivative (PID) control functionality can be implemented in an FPGA. At Marshall Space Flight Center, the Control Electronics Group has been studying adaptive discrete-time control of motor driven actuator systems using digital signal processor (DSF) devices. Our goal is to create a fully digital, flight ready controller design that utilizes an FPGA for implementation of signal conditioning for control feedback signals, generation of commands to the controlled system, and hardware insertion of adaptive control algorithm approaches. While small form factor, commercial DSP devices are now available with event capture, data conversion, pulse width modulated outputs and communication peripherals, these devices are not currently available in designs and packages which meet space level radiation requirements. Meeting our goals requires alternative compact implementation of such functionality to withstand the harsh environment encountered on spacecraft. Radiation tolerant FPGA's are a feasible option for reaching these goals.

Gwaltney, David A.↗

Direct Fault Tolerant RLV Altitude Control: A Singular Perturbation Approach

In this paper, we present a direct fault tolerant control (DFTC) technique, where by "direct" we mean that no explicit fault identification is used. The technique will be presented for the attitude controller (autopilot) for a reusable launch vehicle (RLV), although in principle it can be applied to many other applications. Any partial or complete failure of control actuators and effectors will be inferred from saturation of one or more commanded control signals generated by the controller. The saturation causes a reduction in the effective gain, or bandwidth of the feedback loop, which can be modeled as an increase in singular perturbation in the loop. In order to maintain stability, the bandwidth of the nominal (reduced-order) system will be reduced proportionally according to the singular perturbation theory. The presented DFTC technique automatically handles momentary saturations and integrator windup caused by excessive disturbances, guidance command or dispersions under normal vehicle conditions. For multi-input, multi-output (MIMO) systems with redundant control effectors, such as the RLV attitude control system, an algorithm is presented for determining the direction of bandwidth cutback using the method of minimum-time optimal control with constrained control in order to maintain the best performance that is possible with the reduced control authority. Other bandwidth cutback logic, such as one that preserves the commanded direction of the bandwidth or favors a preferred direction when the commanded direction cannot be achieved, is also discussed. In this extended abstract, a simplistic example is proved to demonstrate the idea. In the final paper, test results on the high fidelity 6-DOF X-33 model with severe dispersions will be presented.

Zhu, J. J.↗

Implementation of Adaptive Digital Controllers on Programmable Logic Devices

Much has been made of the capabilities of Field Programmable Gate Arrays (FPGA's) in the hardware implementation of fast digital signal processing functions. Such capability also makes an FPGA a suitable platform for the digital implementation of closed loop controllers. Other researchers have implemented a variety of closed-loop digital controllers on FPGA's. Some of these controllers include the widely used Proportional-Integral-Derivative (PID) controller, state space controllers, neural network and fuzzy logic based controllers. There are myriad advantages to utilizing an FPGA for discrete-time control functions which include the capability for reconfiguration when SRAM- based FPGA's are employed, fast parallel implementation of multiple control loops and implementations that can meet space level radiation tolerance requirements in a compact form-factor. Generally, a software implementation on a Digital Signal Processor (DSP) device or microcontroller is used to implement digital controllers. At Marshall Space Flight Center, the Control Electronics Group has been studying adaptive discrete-time control of motor driven actuator systems using DSP devices. While small form factor, commercial DSP devices are now available with event capture, data conversion, Pulse Width Modulated (PWM) outputs and communication peripherals, these devices are not currently available in designs and packages which meet space level radiation requirements. In general, very few DSP devices are produced that are designed to meet any level of radiation tolerance or hardness. An alternative is required for compact implementation of such functionality to withstand the harsh environment encountered on spacemap. The goal of this effort is to create a fully digital, flight ready controller design that utilizes an FPGA for implementation of signal conditioning for control feedback signals, generation of commands to the controlled system, and hardware insertion of adaptive-control algorithm approaches. Radiation tolerant FPGA's are a feasible option for reaching this goal.

Gwaltney, David A.↗