Search NASA⌕ Search

SEARCH · Search NASA

Results for “SIGNAL-TO-NOISE RATIO”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Secondaries of eclipsing binaries. IV - The triple system Lambda Tauri

High signal-to-noise ratio Reticon observations of Lambda Tauri have been obtained along with high-quality orbital elements for both the primary and secondary of the eclipsing system. The velocity curve of the secondary is determined for the first time. The findings include: K(1) = 56.9 + or - 0.6 km/s, K(2 = 215.6 + or - 0.7 km/s, m(1) = 7.18 + or - 0.09 solar masses, and m(2) = 1.89 + or - 0.04 solar masses. The 33-day periodicity in the residuals is confirmed and is present in the secondary velocities as well as those of the primary, and can unambiguously be ascribed to orbital motion about a third body. The K and f(m) for the 33-day orbit are 10.1 + or - 0.7 km/s and 0.0034 + or - 0.0008 solar masses. The photometry shows that the orbits are coplanar to within seven degrees. The mass of the third body is 0.7 + or - 0.2 solar masses; it is most probably a K dwarf.

Fekel, F. C., Jr.↗

Adjacent channel interference degradation with minimum shift keyed modulation

Computer simulation results for degradation in signal-to-noise ratio for various values of bit error probability are given for minimum shift-keyed-type signaling in the presence of adjacent channel interference. A serial modulator structure which utilizes spectral shaping is characterized in terms of envelope deviation and bandwidth efficiency. This serial generation technique is convenient for implementation at high data rates and results in signal spectra with lower sidelobe levels than conventional minimum shift-keyed modulation at the expense of moderate envelope deviation. Because of the lower sidelobe levels, the resulting spectra allow denser channel packing than does ideal MSK.

Ziemer, R. E.↗

The effects of transmitter/receiver clock time base instability on coherent communication system performance

The purpose of this paper is to present a model and associated analysis of the deleterious effects which both transmitter and receiver data clock time-base instability have on bit error probability. The types of time-base instability modeled and analyzed include bit jitter (epoch jitter), bit jitter rate (time interval jitter) and data asymmetry. The bit error probability is determined as a function of the statistical characteristics of the time-base instability, the data transition density, the signal-to-noise ratio in the bit rate bandwidth and the mechanizations of both the data bit detector and bit synchronizer. Numerical results are provided.

Chie, C. M.↗

Integrating 128-element linear imager for the 1 to 5 microns region

Useful charge integration has been achieved in high quality photovoltaic InSb diodes when combined with a FET multiplexing (MUX) scheme. An experimental detector assembly with a linear array of 128 InSb diodes coupled to a FEX MUX has been developed. The first stage J-FET preamp, pixel reset switch, MUX, and the InSb array are contained in a hybrid microcircuit of compact dimensions. A low noise preamplifier topology which capitalizes on the low video line capacitance inherent with hybrid fabrication techniques is also utilized. Measurements indicate a signal-to-noise ratio of over 1000:1 and response uniformity of + or - 2 percent. Sample images show subtle detail which supports the estimated radiometric sensitivity of 0.01 K.

Bailey, G. C.↗

Field investigation of techniques for remote laser sensing of oceanographic parameters

A laser fluorosensor, previously studied in the laboratory, was deployed at a pier in lower Chesapeake Bay for field testing. A Q-switched Nd:YAG laser doubled to 532 nm in conjunction with a gated optical multichannel analyzer (OMA) allow spectra with high signal-to-noise ratios to be recorded in full daylight at a distance of 20 m. As a test of the system a study was conducted of the spatial and temporal variations of the phytopigments phycoerythrin and chlorophyll. The phycoerythrin feature was resolved into two components, one attributable to cyanophytes and the other to cryptophytes. A comparison was also made with spectra obtained by the NASA airborne oceanographic lidar (AOL).

Houghton, W. M.↗

Ultraviolet interstellar absorption toward HD 5980 in the Small Magellanic Cloud

Individual high-dispersion International Ultraviolet Explorer (IUE) spectra of extragalactic stars are noisy because of the long exposure times required and the inherent limitations of the IUE detectors. A program has, therefore, been undertaken to obtain multiple ultraviolet spectra of the brightest Magellanic Cloud stars in order to produce composite spectra with higher signal-to-noise ratios than in individual spectra. The present investigation is concerned with results for HD 5980. The target star, HD 5980, is one of the brightest extragalactic far-ultraviolet sources in the sky. HD 5980 is located in the northeast quadrant of NGC 346, the largest H II region and OB star cluster in the SMC. The analysis of the interstellar line spectrum of HD 5980 provides a number of conclusions about the complex absorption characteristics of the interstellar gas toward the SMC.

Fitzpatrick, E. L.↗

Photon counting photodiode array detector for far ultraviolet (FUV) astronomy

A compact, stable, single-stage intensified photodiode array detector designed for photon-counting, far ultraviolet astronomy applications employs a saturable, 'C'-type MCP (Galileo S. MCP 25-25) to produce high gain pulses with a narrowly peaked pulse height distribution. The P-20 output phosphor exhibits a very short decay time, due to the high current density of the electron pulses. This intensifier is being coupled to a self-scanning linear photodiode array which has a fiber optic input window which allows direct, rigid mechanical coupling with minimal light loss. The array was scanned at a 250 KHz pixel rate. The detector exhibits more than adequate signal-to-noise ratio for pulse counting and event location. Previously announced in STAR as N82-19118

Hartig, G. F.↗

Charge-coupled device (CCD) television camera for NASA's Galileo mission to Jupiter

The CCD detector under construction for use in the slow-scan television camera for the NASA Galileo Jupiter orbiter to be launched in 1985 is presented. The science objectives and the design constraints imposed by the earth telemetry link, platform residual motion, and the Jovian radiation environment are discussed. Camera optics are inherited from Voyager; filter wavelengths are chosen to enable discrimination of Galilean-satellite surface chemical composition. The CCO design, an 800 by 800-element 'virtual-phase' solid-state silicon image-sensor array with supporting electronics, is described with detailed discussion of the thermally generated dark current, quantum efficiency, signal-to-noise ratio, and resolution. Tests of the effect of ionizing radiation were performed and are analyzed statistically. An imaging mode using a 2-1/3-sec frame time and on-chip summation of the signal in 2 x 2 blocks of adjacent pixels is designed to limit the effects of the most extreme Jovian radiation. Smearing due to spacecraft/target relative velocity and platform instability will be corrected for via an algorithm maximizing spacial resolution at a given signal-to-noise level. The camera is expected to produce 40,000 images of Jupiter and its satellites during the 20-month mission.

Klaasen, K. P.↗

A coupled phase-locked loops system for carrier tracking improvement

A system that couples several phase-locked loops to improve carrier tracking performance is considered. It coherently combines the received carrier signals at geographically separated ground antennas to increase the total effective aperture. The received carrier's phases are automatically aligned to enhance the received carrier signal-to-noise ratio. The system's tracking performance is assessed in terms of rms phase jitter. It is shown that the phase-locked loop in the first receiver, where the carrier arraying is performed, tracks the received carrier phase using the received carrier power from all receivers.

Divsalar, D.↗

Honeywell multispectral linear array (MLA) instrument design A system overview

In support of NASA's Experimental Land Observing System, a simple, reliable and relatively inexpensive multispectral linear array (MLA) instrument concept has been developed. The design satisfies requirements for multichannel radiometry and wide field imaging. A reflective off-axis anastigmat telescope is mounted in a highly strength-to-weight efficient truss structure, coupled to a solid beamsplitter assembly. Attention is given to the optical design of the MLA instrument, the telescope structure, the detector arrays, detector cooling, on-orbit calibration, signal processing electronics, the spacecraft interfaces, the modulation transfer function, the signal-to-noise ratio, radiometric accuracy, and spatial registration.

Eyring, D.↗

Performance results of a digital test signal generator

Performance results of a digital test signal-generator hardware-demonstration unit are reported. Capabilities available include baseband and intermediate frequency (IF) spectrum generation, for which test results are provided. Repeatability in the setting of a given signal-to-noise ratio (SNR) when a baseband or an IF spectrum is being generated ranges from 0.01 dB at high SNR's or high data rates to 0.3 dB at low data rates or low SNR's. Baseband symbol SNR and carrier SNR (Pc/No) accuracies of 0.1 dB were verified with the built-in statistics circuitry. At low SNR's that accuracy remains to be fully verified. These results were confirmed with measurements from a demodulator synchronizer assembly for the baseband spectrum generation, and with a digital receiver (Pioneer 10 receiver) for the IF spectrum generation.

Gutierrez-Luaces, B. O.↗

Calibration of the receiver channel for the GOPEX precursor experiments

Calibration measurements for the cooled (253 K) photomultiplier tube (PMT) detector, used on the receiver channel of the transmit/receive (T/R) switch for GOPEX, were conducted in the laboratory. A pulsed frequency-doubled neodymium:yttrium-aluminum-garnet (Nd:YAG) laser was used to direct 532-mn light on the PMT. By monitoring the energy per pulse of the light incident on the PMT, the minimum number of photons detected could be determined. These results agreed with the photon flux back-calculated from the PMT output waveform. Approximately 700 incident photons arriving during a temporal pulse width of approximately 65 nsec were detected with a signal-to-noise ratio (SNR) of approximately 1. Other receiver channel characteristics, such as PMT dark currents, optical transmission, and interference filter sensitivity to angle of light incidence, were also measured.

Biswas, A.↗

Project Echo: System Calculations

The primary experimental objective of Project Echo was the transmission of radio communications between points on the earth by reflection from the balloon satellite. This paper describes system calculations made in preparation for the experiment and their adaptation to the problem of interpreting the results. The calculations include path loss computations, expected audio signal-to-noise ratios, and received signal strength based on orbital parameters.

Ruthroff, Clyde L.↗

Project Echo: FM Demodulators with Negative Feedback

The primary experimental objective of Project Echo was the transmission of radio communications between points on the earth by reflection from the balloon satellite. Owing to the large path losses from transmitter to receiver via the satellite, a wide-band frequency modulation technique was used in which bandwidth was traded for signal-to-noise ratio. This paper describes the FM receiving demodulators employed. Negative feedback applied to the local oscillator reduces the FM modulation index in the receiver IF amplifiers, resulting in threshold performance superior to that of conventional FM receivers.

Ruthroff, Clyde L.↗

The Aeolus-Earth DWTS Heliophysics Mission

The Aeolus-Earth Mission (DWTS-Helio) is a recently selected NASA Heliophysics investigation that will apply the innovative Doppler Wind Temperature Sounder (DWTS) technique to the Space Atmosphere Interaction Region (SAIR) at ~105-180 km. The technique, invented by Gordley & Marshall (2011), applies the Doppler Scanning with Gas Filter (DSGF) technique using a cryo-cooled MWIR radiometer to view the limb of the atmosphere from LEO (orbital velocity creates the Doppler shifts required by the technique). For this implementation of DWTS, a Nitric Oxide (NO) low pressure gas cell is used. The limb of the atmosphere is observed from a spacecraft at orbital velocity, and as an observed air volume passes through the field of view, this velocity creates a set of Doppler-shifted images. These images are used to create Doppler Integrated Pass (DIP) signals, from which atmospheric temperature and wind profiles are extracted (it may be considered a converse of the successful in-flight calibration of gas cells used for the HALOE instrument). The technique is relative, removing the need for absolute radiances, and the signal-to-noise ratio for this technique is high, resulting in good measurement precision. Different gas cells can be used to create different altitude coverage and may be combined to measure a more continuous altitude range. For example, using a NO cell captures the lower atmosphere from 30-50km as well as the SAIR, while using the 13 isotopologue of CO2 would capture 50-120km. Due to the desired data volume as well as power and thermal considerations, this initial Aeolus-Earth flight will be more suited for a ‘hosted’ payload on an Orbital Maneuvering Vehicle platform instead of the ‘free-flyer’ option originally investigated. Lastly, the technique is sufficiently powerful that a two-channel system could produce full Mars atmosphere data not currently possible.

DWTS↗

Feasibility test of a solid state spin-scan photo-imaging system

The feasibility of using a solid-state photo-imaging system to obtain resolution imagery from a Pioneer-type spinning spacecraft in future exploratory missions to the outer planets is discussed. Evaluation of the photo-imaging system performance, based on electrical video signal analysis recorded on magnetic tape, shows that the signal-to-noise (S/N) ratios obtained at low spatial frequencies exceed the anticipated performance and that measured modulation transfer functions exhibited some degradation in comparison with the estimated values, primarily owing to the difficulty in obtaining a precise focus of the optical system in the laboratory with the test patterns in close proximity to the objective lens. A preliminary flight model design of the photo-imaging system is developed based on the use of currently available phototransistor arrays. Image quality estimates that will be obtained are presented in terms of S/N ratios and spatial resolution for the various planets and satellites. Parametric design tradeoffs are also defined.

Laverty, N. P.↗

Digital set point control of nonlinear stochastic systems

A technique for digital control of nonlinear stochastic plants is presented. The development achieves a practical digital algorithm with which the closed-loop system behaves in a classical Type I manner even with gross nonlinearities in the plant structure and low signal-to-noise power ratios. The design procedure is explained in detail and illustrated by an example whose simulated responses testify to the practicality of the approach.

Moose, R. L.↗

Passive imaging through the turbulent atmosphere - Fundamental limits on the spatial frequency resolution of a rotational shearing interferometer

The signal-to-noise (S/N) ratio to be expected when a 180 deg rotationally shearing interferometer is used for image recovery at the diffraction limit of a large telescope is computed. The variance and covariance of the irradiance fluctuations at the detector array are shown to yield measures of the high-frequency spatial spectrum of the source. Four fundamental sources of noise are considered: temporal fluctuations of the source, space-time fluctuations of the atmosphere, shot noise in the detected photocurrents, and the effects of finite sampling. S/N is found to be directly proportional to the angular resolution of the telescope, the single-frame integration time, the square root of the number of frames, the cube of the operating wavelength, the quantum efficiency of the detector, and the average spectral irradiance from the source on the pupil. It is inversely proportional to the cube of the field angle subtended by the source (or part thereof) under study.

Burke, J. J.↗