Search NASA⌕ Search

SEARCH · Search NASA

Results for “STORAGE UNIT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

dGen™ (Distributed Generation Market Demand Model) [SWR-17-09]

The Distributed Generation Market Demand (dGen™) model is a geospatially rich, bottom-up, market-penetration model that simulates the potential adoption of distributed energy resources (DERs) for residential, commercial, and industrial entities in the continental United States through 2050. The National Renewable Energy Laboratory (NREL) developed dGen to analyze the key factors that will affect future market demand for distributed solar, wind, storage, and other DER technologies in the United States within a single modeling platform. The dGen model builds on, extends, and provides significant advances over NREL’s SolarDS model (Denholm et al. 2009), which is now deprecated. All Authors and Contributors are alphabetized in the Developers section with Authors of Code listed first, followed by Contributors and do not reflect equal contributions.

Sigrin, Benjamin↗

dGen™ (Distributed Generation Market Demand Model) [SWR-17-09]

The Distributed Generation Market Demand (dGen™) model is a geospatially rich, bottom-up, market-penetration model that simulates the potential adoption of distributed energy resources (DERs) for residential, commercial, and industrial entities in the continental United States through 2050. The National Renewable Energy Laboratory (NREL) developed dGen to analyze the key factors that will affect future market demand for distributed solar, wind, storage, and other DER technologies in the United States within a single modeling platform. The dGen model builds on, extends, and provides significant advances over NREL’s SolarDS model (Denholm et al. 2009), which is now deprecated.

Preus, Robert↗

Oxygen Storage Incorporated Into Net Power and the Allam–Fetvedt Oxy-Fuel sCO2 Power Cycle—Techno-Economic Analysis

Abstract With the planned future reliance on variable renewable energy, the ability to store energy for prolonged time periods will be required to reduce the disruption of market fluctuations. This paper presents a method to analyze a hybrid liquid-oxygen (LOx) storage/direct-fired supercritical carbon dioxide (sCO2) power cycle and optimize the economic performance over a diverse range of scenarios. The system utilizes a modified version of the NET Power process to produce energy when energy demand exceeds the supply while displacing much of the cost of the air separation unit (ASU) energy requirements through cryogenic storage of oxygen. The model uses marginal cost of energy data to determine the optimal times to charge and discharge the system over a given scenario. The model then applies ramp rates and other time-dependent factors to generate an economic model for the system without storage considerations. The size of the storage system is then applied to create a realistic model of the plant operation. From the real plant operation model, the amount of energy charged and discharged, the capital expenditures (CAPEX) of each system, energy costs and revenue and other parameters can be calculated. The economic parameters are then combined to calculate the net present value (NPV) of the system for the given scenario. The model was then run through the SMPSO genetic algorithm in Python for a variety of geographic regions and large-scale scenarios (high solar penetration) to maximize the NPV based on multiple parameters for each subsystem. The LOx storage requirements will also be discussed.

Engineering↗

Solar-Plus-Storage Program Design: Frameworks and Examples [Slides]

The Columbia River Treaty Tribes in the Pacific Northwest - the Nez Perce, Umatilla, Warm Springs, and Yakama - hold treaty-reserved fishing rights for the Columbia River, the largest river in North America flowing into the Pacific Ocean. The four Tribes, through the Columbia River Inter-Tribal Fish Commission (CRITFC), prepared a vision for a more harmonized energy and water system in their 2022 Energy Vision for the Columbia River Basin. In it, the four Tribes envision a future where the Columbia Basin electric power system supports healthy and harvestable fish and wildlife populations, protects Tribal treaty and cultural resources, and provides clean, reliable, and affordable electricity. To help realize the Energy Vision, CRITFC received technical assistance from the National Renewable Energy Laboratory (NREL) through the Communities Local Energy Action Program (LEAP) pilot with the goal of ensuring that the Tribes are fully informed and prepared to integrate their interests into regional power system planning. This resource aims to provide an overview of program and policy design frameworks for behind-the-meter (BTM) energy storage and solar-plus-storage programs and examples from across the United States. This information is intended to build CRITFC's understanding of potential policies and program designs that could support the deployment of solar photovoltaics (PV) and energy storage in the Pacific Northwest.

14 SOLAR ENERGY↗

Geochemical Assessment for Carbon Sequestration in the Conasauga Group, Northwest Georgia, USA

Sedimentary geological formations are known to be great candidates for geological carbon sequestration. Published studies suggest the southeast of the United States contains many formations suitable for carbon storage. The Cassville 1 Stratigraphic Borehole well could act as a potential carbon reservoir for nearby energy resource facilities in Georgia, United States. Although studies have shown that porous formations are adequate for geological carbon sequestration, it is important to understand possible geochemical reactions between CO 2 and the targeted geological formation before injecting any fluids. In this study, a sandstone sample from the Cassville 1 well is being considered for geological carbon sequestration in the Conasauga Group in Northwest Georgia. Here, the collected sandstone sample, consisting of quartz, K-feldspar, micas, kaolinite, and carbonate minerals such as calcite and dolomite, has a 6% porosity. Leveraging the formation composition and porosity, a one-dimensional continuum reactive transport model was built using CrunchFlow to assess possible geochemical reactions between injected CO 2 and the geological formation. Simulation results show that the carbonate minerals, calcite and dolomite, dissolve during the injection period of 10,000 days, increasing formation porosity from 6% to as much as 30%. The rate and extent of carbonate mineral dissolution and resulting porosity increase are highly sensitive to mineral reactive surface area values. No evidence of mineral precipitation was observed, suggesting that dissolution reactions will control porosity evolution during the CO 2 injection period.

42 ENGINEERING↗

Structural Analysis of LaNi 4.25 Al 0.75 Hydride

The lanthanum (La)-nickel (Ni)-aluminum (Al) hydrides (LANA: LaNi 5 − x Al x , x < 1.0) have been extensively studied for their high volumetric storage capacity and improved durability to maintain a single-phase CaCu5 structure through multiple absorption and desorption cycles. Pressure composition temperature (PCT) isotherms obtained for LANA have allowed for an understanding of the hydrogen sorption properties and the tunability of the PCT plateau region via doping. At the Savannah River Site, LaNi 4.25 Al 0.75 (LANA0.75) has been utilized as a hydrogen storage material in the tritium facilities for decades. However, the structure characterization of the LANA0.75 hydride by X-ray diffraction has not yet been reported. This study examines LANA0.75 loaded to different hydrogen-to-metal atom ratios to elucidate both the position of hydrogen sites in the lattice and the structure of a fully hydrided β phase.

hydrogen storage↗

Principles and Options for Designing Battery Energy Storage Zoning Ordinances

Deployment of battery energy storage (BESS) systems, both standalone and as part of hybrid systems paired with generation, has rapidly increased in the United States in recent years as utilities and communities have deployed storage to improve electric grid reliability and act as a cost-effective alternative to larger grid infrastructure. The modular nature of BESS technologies means systems may be built near other existing land uses, creating the potential for conflicts with neighboring landowners that can be managed and mitigated through zoning and permitting requirements established by local jurisdictions. While many cities and counties have adopted ordinances specific to BESS into their local zoning codes, these ordinances vary significantly in their requirements and level of detail. Meanwhile, many other jurisdictions, including those home to proposed or existing BESS projects, lack any specific language related to BESS in their zoning codes. Local planning and zoning officials have limited capacity and may lack the familiarity with BESS technologies needed to develop ordinances or otherwise make reasonable zoning decisions that balance safety, community impacts, and other goals. The resulting uncertainty at the local zoning level has led developers to withdraw projects in some areas and has spurred moratoria or bans on energy storage projects in others. This report intends to provide practical resources for practitioners interested in reasonable and effective local regulation of battery energy storage. It does not present a model zoning ordinance, but rather is intended to complement model ordinances developed by others by providing additional context and analysis regarding the structure of energy storage zoning ordinances and the decision points for local officials. Zoning ordinances at the city, town, and county level across the U.S. were surveyed alongside two template model ordinances to identify common elements and options for regulating the zoning and siting of BESS. Common elements identified and analyzed include definitions and general requirements, including cutoffs or tiers used to apply regulations to different system sizes and the permitted zones where jurisdictions allow BESS to be sited; visual, noise, and aesthetic requirements, including property line setbacks, fencing and visual screening, noise, and lighting requirements; and safety and planning requirements, such as site plans, decommissioning plans or funds, and requirements for access by emergency services. The report also summarizes some of the more unique regulations, including those that place additional restrictions on BESS at the local level.

25 ENERGY STORAGE↗

Pumped Storage Hydropower (PSH) FAST Commissioning Prize Technical Analysis

The US energy landscape has undergone major changes over the past 10 years and will continue to see significant changes in future decades as the power grid increases its reliance on variable renewable energy resources. Because of the inherent variability of these resources, renewable energy growth may require additional energy storage capacity to provide flexible load-following capabilities and other grid services that can quickly adjust to changes in energy demand and generation. Pumped storage hydropower (PSH)—one such energy storage technology—uses pumps to convey water from a lower reservoir to an upper reservoir for energy storage and releases water back to the lower reservoir via a powerhouse for hydropower generation. PSH facility pump and generation cycling often follows economic and energy demand conditions. Across the United States, 43 PSH facilities are in operation and 55 projects are in various permitting or licensing stages. Altogether, the 43 operational projects provide the wide majority (95%) of utility-scale electricity storage in the United States. These facilities also provide significant power and nonpower grid benefits, including large-scale electrical system reserve capacity, grid reliability support, and electricity supply-demand balancing through quick-response capabilities and operational flexibility. PSH systems can accomplish these at a scale (e.g., size) and cost that makes these systems highly attractive from a technical standpoint. Although these research concepts are still in their infancy, they demonstrate promising potential as future PSH energy storage technologies. Although PSH has many advantages, development in the United States has effectively stalled since the 1990s, partially because of the magnitude of project costs and financing interest during development and construction, the length of time from project investment until project revenue begins, permitting challenges, construction risks, competition from other storage technologies (e.g., batteries, hydrogen storage), and electricity market evolution and uncertainty. In short, the time, cost, and risk associated with modern PSH development have resulted in limited growth in the United States recently, despite the growing energy storage demand stemming from increased wind and solar power deployment. Technology innovation is needed to help reduce PSH commissioning time, cost, and risk, particularly during the post-licensing phase of project development. To address challenges facing the PSH industry and to improve PSH commissioning timelines, the US Department of Energy (DOE) Water Power Technologies Office (WPTO) initiated the PSH Furthering Advancements to Shorten Time to (FAST) Commissioning Prize project.

13 HYDRO ENERGY↗

Geothermal district energy systems coupled with seasonal underground thermal energy storage: a U.S. techno-economic screening by climate and geology

In the United States, cooling-dominated commercial building loads can cause geothermal heat pump-based district energy systems to accumulate a long-term subsurface thermal imbalance, motivating the incorporation of seasonal underground thermal energy storage. We developed a transferable workflow to evaluate geothermal district systems that pair ground heat exchangers with seasonal underground thermal energy storage. Using standardized hourly loads for seven commercial buildings and a uniform cost framework, we simulated ten U.S. cities with a physics-based ground heat exchanger model, subsurface storage simulations, and economic assessment to isolate the roles of climate and hydrogeology. In cooling-dominated cities, underground thermal energy storage supplied the majority of annual cooling, cutting electricity use and summer peaks substantially while achieving levelized costs comparable to or below conventional chiller-boiler plants. In cooler climates, the storage share shrunk, required borefield size and costs rose, and levelized cost of energy increased nearly linearly with declining underground thermal energy storage fraction, indicating storage fraction as the primary economic lever. Sensitivity analysis showed capital risk dominated by borefield drilling and surface heating, ventilation, and air-conditioning and piping, with underground thermal energy storage costs secondary. This workflow provides a transparent foundation for site-specific design and screening of next-generation geothermal district energy systems.

25 ENERGY STORAGE↗

Investigation of ventilation-coupled high energy density sensible thermal energy storage

Low-cost energy storage will play an important role in supporting the decarbonization of the energy sector. Here, a novel approach to thermal energy storage for buildings is proposed, in which a tank of antifreeze liquid can be used to heat outdoor air in mechanical ventilation systems. If heated to a high enough temperature, the fluid can potentially undergo temperature swings of nearly 100°C during discharge in cold climates. Because the energy density of sensible storage systems scales proportionally to the system temperature change, this concept has the potential to offer higher energy densities than other liquid-based sensible storage devices used in building applications. A one-dimensional numerical model of the storage system was developed and experimentally validated using 30 wt% (wt%) potassium acetate as an aqueous antifreeze solution. Using a commercial hot water tank, energy densities of 47.0 kW-hour per cubic meter (kWh/m 3 ) were demonstrated in a laboratory setting. Material energy densities of approximately 74.7 (kWh/m 3 ) were measured. Design improvements may boost this energy storage density even further. Because of the system's relative simplicity, ventilation-coupled sensible storage has the potential to be an easily deployable, low-cost energy storage solution for building systems.

25 ENERGY STORAGE↗

Characterization of the Triassic Newark Basin of New York and New Jersey for Geologic Storage of Carbon Dioxide

The project Characterization of the Triassic Newark Basin of New York and New Jersey for Geologic Storage of Carbon Dioxide is one of 9 site characterization projects that were implemented as part of ARRA (American Recovery and Reinvestment Act). Data from this project was used to improve resolution of data in NATCARB in the area of study. Data related to this study has already been incorporated in NATCARB Atlas. Sandia Technologies, LLC, and co-investigator Conrad Geoscience Corporation, examined the potential for large-scale, permanent CO2 storage in sedimentary strata within the Newark Rift Basin. The Newark Rift Basin underlies an industrialized, developed region comprising parts of New York, New Jersey, and Pennsylvania. The project characterized and investigated the suitability of Triassic age sedimentary formations for potential geologic CO2 storage. The project team drilled and cored two test wells to define the sedimentary geologic formations underlying the basin and to document or reach basement rock. With this geologic characterization phase, an integration of seismic, geologic, borehole, and formation core results provided a higher resolution assessment of CO2 storage potential. The Stockton Formation is known to be a potentially favorable geologic storage formation in the basin. In 2011, the 1-NYSTA Tandem Lot stratigraphic test well was drilled to a depth of 6,855 feet in the northern portion of the Newark Basin in southern New York State. Approximately 9 miles south-southeast on the Lamont Doherty Campus, TW-4 was drilled and cored in 2013 to a depth of 1,802 feet and contacted apparent igneous basement at a depth of 1,712 feet. Both wells penetrated the Palisades Sill ranging from 800 feet thick in the eastern well to approximately 1,800 feet in thickness at the 1-NYSTA Tandem Lot deep drill site. A diabase sill can provide an excellent seal and dense confining layer for potential CO2 storage reservoirs and flow layers that are situated beneath it within the Stockton Sandstone. The Stockton Sandstone was encountered beneath the sill in the TW-4 well on the Lamont campus, and data integration suggests that it was likely observed near total depth in the deep 1-NYSTA Tandem Lot well. The test wells confirm and define reservoirs are present beneath the sill and offer CO2 storage potential. The integration of geologic and reservoir characterization of well logs, formation cores, and formation fluids indicated Triassic age lacustrine playa lake and mudbank shales of the Upper Passaic Group can provide an effective seal for the porous and permeable underlying sandstone reservoir layers. This project acquired seismic data, drilled borehole well logs, acquired core samples, and integrated these findings to provide a better understanding of the subsurface geologic formations in the Newark Rift Basin. These findings have contributed to a higher degree of accuracy in predicting potential geologic storage opportunities, while refining geologic storage capacity estimates for the indicated reservoirs and flow units.

.las↗

Topology Optimization of Curved Electrodes with Suggested Simplified Corrugated Designs

The demand for space-efficient energy storage, from grid to device scale, has soared with the rapid electrification of society. To increase energy density while maintaining high rate performance, shaping electrodes has been shown to be an effective strategy. Computational optimization can suggest designs that improve energy storage performance; however, generated designs are often complex, leading to manufacturing challenges. Additionally, most optimization is typically conducted in standard rectangular domains, whereas some applications, such as in the aerospace industry or in consumer electronics, may benefit from optimized electrodes that fit in a nonstandard form factor. Here, in this work, we use topology optimization to design capacitive full-cell electrodes in a curved domain. We propose a simplified corrugated electrode design based on the optimization results and show that the energy stored in the simplified design is only reduced by about 5–27% when compared to that in the fully optimized design, with more deviation occurring when ionic transport in the porous electrode is particularly impeded. Overall, we find that these simplified designs are promising, particularly given the more conventional manufacturing techniques required, and have a 42–369% increase in energy stored compared to monolithic electrodes.

Energy - Storage↗

Perspective—Hydrogen Bonded Concentrated Electrolytes for Redox Flow Batteries: Limitations and Prospects

This perspective provides a brief overview of the recent work on electrolytes with hydrogen (H)-bonding network, specifically the deep eutectic solvents (DESs), and outlines important factors to consider when adapting these electrolytes in redox flow batteries (RFBs). The redox behavior, solubility, and stability of several redox molecules of relevance to RFBs in DESs are presented, including some of our work within the Breakthrough Electrolytes for Energy Storage (BEES)—an Energy Frontier Research Center of the United States Department of Energy. Particularly, the challenges and opportunities for further development of DESs for energy storage are discussed.

25 ENERGY STORAGE↗

Hydrogen Storage for Flexible Fossil Fuel Power Generation: Integration of Underground Hydrogen Storage with Gas Turbine (Final Report)

As the nation continues to encourage, through market structures and financial incentives, the proliferation of intermittent renewable electricity, how to optimize the ever-changing electric grid and identify means to retain and improve resilience, while ensuring continued reductions in GHG emissions, will be critical. According to Bloomberg, wind & solar generated 10.5% of US electricity in 2020 and that percentage continues to grow. In support of expanding renewable energy use, and to address its intermittent nature, this project will develop the Hydrogen Storage for Flexible Fossil Fuel Power Generation platform that is dispatchable, reliable, repeatable and have the ability to produce zero or negative carbon power while interfacing with geology capable of CO2 and hydrogen storage. GTI Energy (GTIE) and team members Illinois State Geological Survey (ISGS), Mitsubishi Heavy Industries America (MHIA), Ameren Illinois, Hexagon Purus, and the Low Carbon Resources Initiative (LCRI) completed a Phase I Conceptual Study under contract DE-FE0032012 for Hydrogen Storage for Flexible Fossil Fuel Power Generation: Integration of Underground Hydrogen Storage with Gas Turbine. The Hydrogen Storage for Flexible Fossil Fuel Power Generation platform addresses the intermittent nature of the expanding use of Variable Renewable Energy (VRE) generation. The low cost of the electricity (COE) generated results in greater dispatch and more operation at higher power levels (higher efficiency), fewer short intervals, and fewer start/stop cycles. The reliable, resilient system can produce zero carbon power and store hydrogen. It will demonstrate hydrogen storage in geologic formations like those used in natural gas underground storage thus enabling large scale storage of hydrogen in sedimentary strata across the United States rather than in geographically restricted salt caverns. The Phase I study confirmed the system is feasible and generates power at lower cost than other low carbon approaches. The demonstration defines the pathway for broad commercial application and will accelerate the development of larger systems suitable for centralized utility scale electricity production. The study advanced the maturity of the H 2 storage-based system with flexible power generation by completing a Pre-FEED study (Phase II). The Pre-FEED focused on the selected Energy Farm on the University of Illinois Urbana-Champaign (UIUC) site that includes above ground and underground hydrogen storage, low-carbon hydrogen production (GTI’s Compact Hydrogen Generator, CHG) with underground CO2 sequestration, and a 40-MW class gas turbine. The Pre-FEED addressed the entire system and its interconnection to the natural gas and electric grid and mitigation of key risks, such as storage behavior, load-following, and system operation. During Phase 1 of the project, the team completed key tasks, which moved the entire demonstration project, specific components and approaches closer to commercialization. These Phase I Accomplishments include: Completing System Requirements Review; Completing System Layout and Modeling - Heat & Mass Balance and Process Flow Diagram; Completing modelling of 9 turbine performance cases; Evaluating rock strata for underground storage of hydrogen and sequestration of carbon dioxide; Completing initial modelling of underground storage of hydrogen and withdrawal with evaluation of loss and water production; Identifying roadable storage for above ground hydrogen storage; Identifying existing electrical infrastructure for receiving/delivering electricity; Identifying existing gas supply infrastructure for receiving natural gas; Document concept design/development plans in required reports. Conclusions: The 12-month Feasibility study in Phase I study was completed and confirmed the system is feasible and generates power at lower cost than other low carbon approaches and even lower cost than the reference NGCC plant without carbon capture when taking advantage of 45Q carbon credits. The study enabled the fidelity of the concept to be improved and allowed identification of the requirements for the system. Defining the individual system and component requirements was performed via the system requirements review with the whole team. These requirements were then incorporated into and iterated with our Heat & Mass Balance process model and process flow diagrams were generated to reflect the overall system. This information was then used to complete the TEA and show economic feasibility. Large scale non-salt geologic storage of hydrogen is an enabling technology for a hydrogen-fired turbine that can be retrofitted into large-scale electric generating units (EGU). Our demonstration will include 428 MWh or ~4 hours full load of hydrogen storage (above and underground). Carbon capture inherent to the CHG process can capture 90% CO 2 (with upgrades to >98%). This system provides a COE of 23% savings relative to an NGCC with a post combustion amine system. Our proposed storage system decouples carbon capture and hydrogen production from power production; therefore, we expect our proposed system’s efficiency and variable COE to be superior resulting in overall higher dispatch and reduced deep cycling. Our demonstration will be full to multi-day hydrogen storage and has the potential for longer (seasonal) duration commercially. The demonstration defines the pathway for broad commercial application and will accelerate the development of larger systems suitable for centralized utility scale electricity production.

03 NATURAL GAS↗

Plastic from CO 2 , Water, and Electricity: Tandem Electrochemical CO 2 Reduction and Thermochemical Ethylene-CO Copolymerization

Converting CO 2 into industrially useful products is an appealing strategy for utilization of an abundant chemical resource. Electrochemical CO 2 reduction (eCO 2 R) offers a pathway to convert CO 2 into CO and ethylene, using renewable electricity. Here, these products can be efficiently copolymerized by organometallic catalysts to generate polyketones. However, the conditions for these reactions are very different, presenting the challenge of coupling microenvironments typically encountered for the transformation of CO 2 into highly complex but desirable multicarbon products. Herein, we present a system to produce polyketone plastics entirely derived from CO 2 and water, where both the CO and C 2 H 4 intermediates are produced by eCO 2 R. In this system, a combination of Cu and Ag gas diffusion electrodes is used to generate a gas mixture with nearly equal concentrations of CO and C 2 H 4 , and a recirculatory CO 2 reduction loop is used to reach concentrations of above 11% each, leading to a current-to-polymer efficiency of up to 51% and CO 2 utilization of 14%.

carbon storage↗

Architectural Approaches for Integrating ADMS and DERMS: Challenges, Comparisons, and Real-World Use Cases

The electrical distribution landscape is rapidly transforming due to the proliferation of distributed energy resources (DERs) such as solar panels, wind turbines, battery storage systems, combined heat and power units, and electric vehicles, introducing variability and uncontrollability that traditional grid operators are ill-equipped to manage. This transformation is further accelerated by advancements in Information and Communication Technology infrastructure that connects control centers with end devices, demanding automation and a deeper understanding of new technologies by utility personnel. Advanced grid control techniques using system-level optimization, Artificial Intelligence, and Machine Learning at the enterprise level and distributed level are evolving to address these issues. There is also an opportunity to utilize the enormous data created by these new DER technologies in the grid. Advanced Distribution Management Systems (ADMS) and Distributed Energy Resource Management Systems (DERMS) are critical in addressing these challenges by automating grid operations and enhancing reliability. Given the relatively recent development of ADMS and DERMS, and the still relatively low level of ADMS and DERMS deployment in the industry, there is a notable deficiency in the comprehensive understanding of the challenges and benefits associated with these new technologies, especially with their complementary natures and integration architectures. This paper aims to bridge the knowledge gap in ADMS and DERMS integration, presenting three distinct integration architectures currently available, and discussing the challenges and benefits of each architecture to guide utilities, industry professionals, and researchers in optimizing grid management and decision-making processes for a resilient and efficient energy future.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Thermo-hydro-mechanical analysis of subsurface ice-based thermal energy storage

Ice-based thermal energy storage systems are widely utilized for cooling and managing peak electrical demand globally, offering daily or weekly storage capabilities for both individual homes and larger office buildings. However, scaling these systems for district-level cooling or integrating them with renewable energy sources presents challenges, especially in accommodating larger volumes and addressing seasonal storage requirements in densely populated urban areas. This paper proposes a novel solution by evaluating subsurface ice-based thermal energy storage, in which the underground is subjected to seasonal freeze/thaw cycles. However, these cycles may influence ground behavior, affecting pore pressure and inducing ground movement. To systematically investigate these challenges, we enhance the TOUGH-FLAC simulator by integrating water/ice phase change capabilities and updating the effective stress–strain constitutive relation. Both modifications are validated against analytical solutions or experimental data. Through numerical simulations spanning a decade with ten seasonal freeze/thaw cycles, we evaluate the performance and long-term stability of a generic subsurface ice-based thermal energy storage system, considering factors such as ground permeability, freezing pipe spacing, freeze/thaw damage, and glycol solution temperature. The simulations indicate that ice formation induces pore pressure variations that drive seasonal surface heave and settlement, controlled by ground permeability, pipe spacing, and glycol solution temperature, along with tensile and localized shear deformation around freeze pipes. This highlights the need for accurate ground property characterization and geomechanical analysis for subsurface ice-based thermal energy storage.

Ground freezing↗

Strong temporal variability in methane fluxes from natural gas well pad soils

We measured methane and carbon dioxide fluxes at natural gas well pad soils and undisturbed soils in the Rocky Mountain and Gulf Coast regions of the United States, including producing and gas storage wells. We collected both short-term (15 min) and multi-day (between 3 and 8), continuous measurements at 47 well pads and two undisturbed locations. Methane fluxes varied by more than an order of magnitude over periods as short as 30 min (e.g., 19–593 mg m -2 h -1 in one instance), and diurnal and seasonal variability was also significant (e.g., spring-to-fall change from 509 to 14174 mg m -2 h -1 ). We hypothesize that short-term flux variability was caused by pulsed flow of methane during its migration through the subsurface. Barometric pressure and well conditions likely impacted fluxes, but we found only weak evidence for this. Bacterial methanotrophy appeared to impact methane flux magnitude and variability. We injected methane into the subsurface at one well, and we found that, while fluxes of methane and carbon dioxide, and combustible soil gas concentrations, increased in response to the injection, the response was not uniform, and fluxes exhibited high hourly-scale variability, in spite of a constant injection rate. Methane fluxes tended to be higher at well pad soils compared to background soils (often much higher), and fluxes tended to be higher at well pad locations closer to the well head.

03 NATURAL GAS↗