Search NASA⌕ Search

SEARCH · Search NASA

Results for “SWEEP”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Polarimetry Using Graphene-Integrated Anisotropic Metasurfaces

Polarization is one of the important properties of light, and its detection is of significant interest for various fundamental and practical applications. Here, we demonstrate a mid-infrared polarimetry device using a gate-tunable graphene-integrated anisotropic metasurface. The Stokes parameters of the incident light are extracted by sweeping the gate voltage applied to the device and subsequent fitting of the measured reflected intensities. Considering subpicosecond carrier relaxation times in graphene, the polarization measurement rate of our device is governed only by the speed of the gate voltage sweep. Thus, our work serves as a proof-of-principle demonstration for high-speed microscale polarimetric devices.

36 MATERIALS SCIENCE↗

Carbon dioxide capture using a CO{sub 2}-selective facilitated transport membrane

A novel CO{sub 2}-selective membrane with the facilitated transport mechanism has been synthesized to capture CO{sub 2} from the industrial gas mixtures, including flue gas. Both mobile and fixed amine carriers were incorporated into the cross-linked poly(vinyl alcohol) (PVA) during the membrane synthesis. The membrane showed desirable CO{sub 2} permeability (with a suitable effective thickness) and CO{sub 2}/N{sub 2} selectivity up to 170{sup o} C. In the CO{sub 2} capture experiments from a gas mixture with N{sub 2} and H{sub 2}, a permeate CO{sub 2} dry concentration of {gt}98% was obtained, using steam as the sweep gas. The effects of the feed flow rate and the sweep:feed molar ratio on the membrane separation performance were investigated. A one-dimensional isothermal model was established to examine the performance of a hollow-fiber membrane module composed of the described CO{sub 2}-selective membrane. The modeling results show that a CO{sub 2} recovery of {gt}95% and a permeate CO{sub 2} dry concentration of {gt}98% are achievable from a 1000 standard cubic feet per minute (SCFM) (or 21.06 mol/s) flue gas stream with a 2 ft (0.61 m) hollow-fiber module that contained 980 000 fibers.

01 COAL, LIGNITE, AND PEAT↗

In Situ X-ray Absorption Spectroscopy of a Synergistic Co–Mn Oxide Catalyst for the Oxygen Reduction Reaction

Identifying the catalytically active site(s) in the oxygen reduction reaction (ORR), under real-time electrochemical conditions, is critical to the development of fuel cells and other technologies. We have employed in situ synchrotron-based X-ray absorption spectroscopy (XAS) to explore the synergistic interaction of a Co–Mn oxide catalyst which exhibits impressive ORR activity in alkaline fuel cells. X-ray absorption near edge structure (XANES) was used to track the dynamic structural changes of Co and Mn under both steady state (constant applied potential) and nonsteady state (potentiodynamic cyclic voltammetry, CV). Under steady state conditions, both Mn and Co valences decreased at lower potentials, suggesting the conversion from Mn-(III,IV) and Co(III) to Mn(II,III) and Co(II), respec-tively. Rapid X-ray data acquisition, combined with a slow sweep rate in CV, enabled a 3 mV resolution in the applied potential, approaching a nonsteady (potentiody-namic) state. Changes in the Co and Mn valence states were simultaneous and exhibited periodic patterns that tracked the cyclic potential sweeps. To the best of our knowledge, this represents the first study, using in situ XAS, to resolve the synergistic catalytic mechanism of a bimetallic oxide. Strategies developed/described herein can offer an enticing approach to unveil the reaction mechanism for other multimetallic electrocatalysts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Enlarged Nonclosure of Surface Energy Balance With Increasing Atmospheric Instabilities Linked to Changes in Coherent Structures

The nonclosure of surface energy balance remains an outstanding problem in eddy covariance (EC) measurements of land-surface fluxes of heat, water vapor, and CO 2 . Our data collected from an EC tower over a semiarid sagebrush ecosystem indicate that under unstable atmospheric conditions, the nonclosure becomes increased with increasing instability, consistent with many other studies. It is demonstrated that the increased nonclosure is not caused by the inadequate sampling of large-scale turbulent motions using a 30-min averaging interval, though the scales of turbulent motions dominating sensible and latent heat fluxes become enlarged with increasing instability. Quadrant analysis is then used to reveal that the flux contributions from ejections remain nearly constant with increasing instability, whereas the flux contributions from sweeps are reduced and their time fractions increase. Our results imply that the increased nonclosure of surface energy balance is associated with changes in turbulent structures including their dominant time scales and flux contributions of ejections and sweeps as the atmospheric instability increases, which require further studies using vertically distributed observations and/or large eddy simulations.

54 ENVIRONMENTAL SCIENCES↗

Simultaneous detection of electronic structure changes from two elements of a bifunctional catalyst using wavelength-dispersive X-ray emission spectroscopy and in situ electrochemistry.

Multielectron catalytic reactions, such as water oxidation, nitrogen reduction, or hydrogen production in enzymes and inorganic catalysts often involve multimetallic clusters. In these systems, the reaction takes place between metals or metals and ligands to facilitate charge transfer, bond formation/breaking, substrate binding, and release of products. In this study, we present a method to detect X-ray emission signals from multiple elements simultaneously, which allows for the study of charge transfer and the sequential chemistry occurring between elements. Kβ X-ray emission spectroscopy (XES) probes charge and spin states of metals as well as their ligand environment. A wavelength-dispersive spectrometer based on the von Hamos geometry was used to disperse Kβ signals of multiple elements onto a position detector, enabling an XES spectrum to be measured in a single-shot mode. This overcomes the scanning needs of the scanning spectrometers, providing data free from temporal and normalization errors and therefore ideal to follow sequential chemistry at multiple sites. We have applied this method to study MnOx-based bifunctional electrocatalysts for the oxygen evolution reaction (OER) and the oxygen reduction reaction (ORR). In particular, we investigated the effects of adding a secondary element, Ni, to form MnNiOx and its impact on the chemical states and catalytic activity, by tracking the redox characteristics of each element upon sweeping the electrode potential. The detection scheme we describe here is general and can be applied to time-resolved studies of materials consisting of multiple elements, to follow the dynamics of catalytic and electron transfer reactions.

Gul, Sheraz↗

Electrodeposition of ligand-free copper nanoparticles from aqueous nanodroplets

Copper nanoparticles have emerged as promising electrocatalysts for energy storage and conversion. Generally, homogenous nanoparticle synthesis requires a stabilizing ligand, which may influence the electrocatalysis. Ligands can be avoided by direct nanoparticle electrodeposition. Here, we extend nanodroplet-mediated electrodeposition to the electrodeposition of copper nanoparticles from aqueous nanodroplets suspended in 0.1 M tetrabutylammonium hexafluorophosphate ([TBA][PF 6 ]) and 1,2-dichloroethane. Stochastic electrochemistry on microelectrodes was used to elucidate nanoparticle growth kinetics for various solution conditions and substrate materials. A study on the effect of surfactants on nanoparticle morphology and growth kinetics demonstrated the surfactant's role as an avenue for morphological control. Nanoparticle morphology was studied by Scanning Electron Microscopy (SEM) and Transmission Electron Microscopy (TEM). Energy-dispersive X-ray Spectroscopy (EDX) confirmed the presence of copper nanoparticles. TEM and Selected Area Electron Diffraction (SAED) confirmed nanoparticle size, morphology, and polycrystallinity. We demonstrate tunable nanoparticle size using cyclic voltammetry on single aqueous nanodroplets by altering the voltammetric sweeping potentials of copper electroreduction. Finite element simulations validate the voltammetric response and ability to control the nanoparticle size with nanometer resolution during a voltammetric sweep. These results inform the electrodeposition of copper nanoparticles from aqueous nanodroplets for important applications, such as the conversion of CO 2 to hydrocarbon fuels.

36 MATERIALS SCIENCE↗

Use of the absolute phase in frequency modulated continuous wave plasma reflectometry

In frequency modulated continuous wave reflectometry, used for density profile measurement in fusion plasmas, it is usual to measure the beat frequency between the launched wave and the reflected wave, and from this to calculate the position of the reflecting layer in the plasma. The absolute phase of the beat signal is usually neglected. The reason is that the phase shift between sweeps is usually comparable with or more than 2{pi}, leading to an ambiguity that is impossible to resolve. However, recent observations on the MAST tokamak have shown that, under quiet plasma conditions (this term has to be defined), the phase shift between sweeps is small compared with 2{pi} and the phase ambiguity can be readily resolved. The reflectometer signal is then being analyzed as an interferometer signal would normally be, and there is a substantial improvement in spatial resolution. The method is illustrated by application to small edge localized mode precursor and allows what is believed to be the first quantitative measurement of the displacement of the plasma boundary by such a precursor mode. The errors in both the absolute phase measurement and the more conventional frequency measurement are also estimated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Determining electron temperature for small spherical probes from network analyzer measurements of complex impedance

In earlier work, using a network analyzer, it was shown that collisionless resistance (CR) exists in the sheath of a spherical probe when driven by a small rf signal. The CR is inversely proportional to the plasma density gradient at the location where the applied angular frequency equals the plasma frequency {omega}{sub pe}. Recently, efforts have concentrated on a study of the low-to-intermediate frequency response of the probe to the rf signal. At sufficiently low frequencies, the CR is beyond cutoff, i.e., below the plasma frequency at the surface of the probe. Since the electron density at the probe surface decreases as a function of applied (negative) bias, the CR will extend to lower frequencies as the magnitude of negative bias increases. Therefore to eliminate both CR and ion current contributions, the frequencies presently being considered are much greater than the ion plasma frequency, {omega}{sub pi}, but less than the plasma frequency, {omega}{sub pe}(r{sub 0}), where r{sub 0} is the probe radius. It is shown that, in this frequency regime, the complex impedance measurements made with a network analyzer can be used to determine electron temperature. An overview of the theory is presented along with comparisons to data sets made using three stainless steel spherical probes of different sizes in different experimental environments and different plasma parameter regimes. The temperature measurements made by this method are compared to those made by conventional Langmuir probe sweeps; the method shown here requires no curve fitting as is the usual procedure with Langmuir probes when a Maxwell-Boltzmann electron distribution is assumed. The new method requires, however, a solution of the Poisson equation to determine the approximate sheath dimensions and integrals to determine approximate plasma and sheath inductances. The solution relies on the calculation of impedance for a spherical probe immersed in a collisionless plasma and is based on a simple circuit analogy for the plasma. Finally, the temperatures obtained using this method show reasonable agreement with those obtained using a conventional Langmuir sweep analysis of the spheres.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Invited Article: Data analysis of the Floating Potential Measurement Unit aboard the International Space Station

We present data from the Floating Potential Measurement Unit (FPMU) that is deployed on the starboard truss of the International Space Station. The FPMU is a suite of instruments capable of redundant measurements of various plasma parameters. The instrument suite consists of a floating potential probe, a wide-sweeping spherical Langmuir probe, a narrow-sweeping cylindrical Langmuir probe, and a plasma impedance probe. This paper gives a brief overview of the instrumentation and the received data quality, and then presents the algorithm used to reduce I-V curves to plasma parameters. Several hours of data are presented from August 5, 2006 and March 3, 2007. The FPMU derived plasma density and temperatures are compared with the International Reference Ionosphere (IRI) and Utah State University-Global Assimilation of Ionospheric Measurement (USU-GAIM) models. Our results show that the derived in situ density matches the USU-GAIM model better than the IRI, and the derived in situ temperatures are comparable to the average temperatures given by the IRI.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental Verification of Predicted Oscillations near a Spin Resonance

The Chao matrix formalism allows analytic calculations of a beam's polarization behavior inside a spin resonance. We recently tested its prediction of polarization oscillations occurring in a stored beam of polarized particles near a spin resonance. Using a 1.85 GeV/c polarized deuteron beam stored in COSY, we swept a new rf solenoid's frequency rather rapidly through 400 Hz during 100 ms, while varying the distance between the sweep's end frequency and the central frequency of an rf-induced spin resonance. Our measurements of the deuteron's polarization for sweeps ending near and inside the resonance agree with the Chao formalism's predicted oscillations.

43 PARTICLE ACCELERATORS↗

Temporal limits of a rapidly swept Langmuir probe

The finite, electrostatically achievable, temporal resolution of plasma properties from a turbulent discharge is limited by an array of effects wherein the theory of Langmuir probes breaks down. Formulations for the particle transit time, sheath formation time, plasma-probe resonance, polarization current, sheath capacitance, stray capacitance, and mutual capacitance effects are all evaluated for time-resolved operation of a Langmuir probe. The resulting time scales serve to place a theoretical bound on the maximum rate of a rapidly swept Langmuir probe as analyzed with typical thin-sheath collisionless probe theory. For plasma typical to the plume of a Hall effect thruster [xenon plasma, n{sub e}=(1-1000)x10{sup +15} m{sup -3}, and T{sub e}=1-20 eV], upper limits of 0.01-70 kHz are observed for a noncapacitive compensated Langmuir probe. With a high-speed dual Langmuir probe (HDLP) (a regular probe plus a null compensation probe), the upper probing frequency limits are increased to 0.04-11 MHz limited by sheath capacitance in the far and near field, and polarization effects for closer internal measurements. For a typical tokamak edge plasma (with HDLP), the thermally equilibrated hotter species (typically T{sub e}approx =T{sub i}approx =10 to 20 eV) and lighter ions together lend higher limiting rates of ion transit, sheath formation, and sheath capacitance effects (in excess of 20 MHz), but the fully magnetized plasma complicates the collected probe current, limiting the allowable sweep rate to <1 MHz (for a magnetic field of 2 T). Thus we find that the upper rate of Langmuir probe sweeping is in the low megahertz range for both electric thruster and fusion plasma device diagnostics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental Modal Analysis on a Rotating Fan Using Tracking-CSLDV

Continuous Scan Laser Doppler Vibrometry (CSLDV) modifies the traditional mode of operation of a vibrometer by sweeping the laser measurement point continuously over the structure while measuring, enabling one to measure spatially detailed mode shapes quickly and minimizing the inconsistencies that can arise if the structure or test conditions change with time. When a periodic scan path is employed, one can decompose the measurement into the response that would have been measured at each point traversed by the laser and obtain the structure's mode shapes and natural frequencies using conventional modal analysis software. In this paper, continuous-scan vibrometry is performed on a rotating fan, using computer controlled mirrors to track the rotating fan blades while simultaneously sweeping the measurement point over the blades. This has the potential to circumvent the difficulty of attaching contact sensors such as strain gauges, which might modify the structure and invalidate the results. In this work, impact excitation was used to excite a 3-blade fan rotating at various speeds, and the blades were scanned with a cloverleaf pattern that captured the bending of all three blades simultaneously. Some specialized signal processing is helpful in minimizing the effect of rotation frequency harmonics in the measurements, and specific scan strategies are needed to avoid those frequencies, both of these issues are discussed in the paper. While noise in the laser vibrometer does pose some difficulty, the results show that several modes could be extracted and that the tracking-CSLDV results agree with measurements obtained from the parked fan.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

On the interpretation of Langmuir probe data inside a spacecraft sheath

If a Langmuir probe is located inside the sheath of a negatively charged spacecraft, there is a risk that the probe characteristic is modified compared to that of a free probe in the ambient plasma. We have studied this probe-in-spacecraft-sheath problem in the parameter range of a small Langmuir probe (with radius r{sub LP}<<{lambda}{sub D}) using a modified version of the orbit motion limited (OML) probe theory. We find that the ambient electron contribution I{sub e}(U{sub LP}) to the probe characteristic is suitably analyzed in terms of three regions of applied probe potential U{sub LP}. In region I, where the probe is negatively charged (i.e., U{sub LP} U{sub 1}, there is first a transition region II in applied potential, U{sub 1}<U{sub LP}<U{sub 2}, in which the key factor to determine the shape of I{sub e}(U{sub LP}) is a potential minimum U{sub M} between the probe and the ambient plasma. This minimum gives the depth U{sub pl}-U{sub M} of a potential barrier that prevents the lowest energy ambient electrons from reaching the probe. For a high enough positive probe potential, in region III, the barrier becomes small. Here, I{sub e}(U{sub LP}) again approaches OML theory for a free probe. The boundary U{sub 2} between regions II and III is somewhat arbitrary; we propose a condition on the barrier, U{sub pl}-U{sub M}<<k{sub B}T{sub e}/e, as the definition of region III. The main findings in this work are qualitative rather than quantitative. The existence of the transition region points to that special care must be taken to extract plasma parameters from measured I(U{sub LP}) as the probe characteristic is likely to depart from usual OML in crucial respects: (1) the ambient plasma potential U{sub pl} falls into the transition region, but there is no obvious knee or other feature to identify it, (2) there is in this region no exponential part of I{sub e}(U{sub LP}) that can be used to obtain T{sub e}, instead, (3) the probe size is important in determining the curve shape. We have tentatively applied our simplified probe-in-sheath model to real probe data from the Cassini spacecraft, taken in the dense plasma of Saturn's magnetosphere. We propose that our model gives a better description than OML of measured Langmuir probe sweeps in space plasmas where the Langmuir probe is situated within the spacecraft sheath, i.e., for long Debye lengths. The understanding of these probe sweep effects in such regions may improve by self-consistent particle simulations of the spacecraft environment.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Scrape-off layer reflectometer for Alcator C-Mod

A swept-frequency X-mode reflectometer is being built for Alcator C-Mod to measure the scrape-off layer density profiles at the top, middle, and bottom locations in front of both the new lower hybrid launcher and the new ion cyclotron range of frequencies antenna. The system is planned to operate between 100 and 146 GHz at sweep rates from 10 {mu}s to 1 ms, and will cover a density range of approximately 10{sup 16}-10{sup 20} m{sup -3} at B{sub 0}=5-5.4 T. To minimize the effects of density fluctuations, both differential phase and full phase reflectometry will be employed. Design, test data, and calibration results of this electronics system will be discussed. To reduce attenuation losses, tallguide (TE{sub 01}) will be used for most of the transmission line system. Simulations of high mode conversion in tallguide components, such as e-plane hyperbolic secant radius of curvature bends, tapers, and horn antennas will be shown. Experimental measurements of the total attenuation losses of these components in the lower hybrid waveguide run will also be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Standard design for National Ignition Facility x-ray streak and framing cameras

The x-ray streak camera and x-ray framing camera for the National Ignition Facility were redesigned to improve electromagnetic pulse hardening, protect high voltage circuits from pressure transients, and maximize the use of common parts and operational software. Both instruments use the same PC104 based controller, interface, power supply, charge coupled device camera, protective hermetically sealed housing, and mechanical interfaces. Communication is over fiber optics with identical facility hardware for both instruments. Each has three triggers that can be either fiber optic or coax. High voltage protection consists of a vacuum sensor to enable the high voltage and pulsed microchannel plate phosphor voltage. In the streak camera, the high voltage is removed after the sweep. Both rely on the hardened aluminum box and a custom power supply to reduce electromagnetic pulse/electromagnetic interference (EMP/EMI) getting into the electronics. In addition, the streak camera has an EMP/EMI shield enclosing the front of the streak tube.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Combined ideal and kinetic effects on reversed shear Alfven eigenmodes

A reversed shear Alfven eigenmodes (RSAEs) theory has been developed for reversed magnetic field shear plasmas when the safety factor minimum, q{sub min}, is at or above a rational value. The modes we study are known sometimes as either the bottom of the frequency sweep or the down sweeping RSAEs. We show that, strictly speaking, the ideal MHD theory is not compatible with the eigenmode solution in the reversed shear plasma with q{sub min} above integer values. Corrected by a special analytic finite Larmor radius (FLR) condition, MHD dispersion of these modes nevertheless can be developed. Numerically, MHD structure can serve as a good approximation for the RSAEs.The large radial scale part of the analytic RSAE solution can be obtained from ideal MHD and expressed in terms of the Legendre functions. The kinetic equation with FLR effects for the eigenmode is solved numerically and agrees with the analytic solutions. Properties of RSAEs and their potential implications for plasma diagnostics are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Impact of metal nano layer thickness on tunneling oxide and memory performance of core-shell iridium-oxide nanocrystals

The impact of iridium-oxide (IrO{sub x}) nano layer thickness on the tunneling oxide and memory performance of IrO{sub x} metal nanocrystals in an n-Si/SiO{sub 2}/Al{sub 2}O{sub 3}/IrO{sub x}/Al{sub 2}O{sub 3}/IrO{sub x} structure has been investigated. A thinner (1.5 nm) IrO{sub x} nano layer has shown better memory performance than that of a thicker one (2.5 nm). Core-shell IrO{sub x} nanocrystals with a small average diameter of 2.4 nm and a high density of {approx}2 x 10{sup 12}/cm{sup 2} have been observed by scanning transmission electron microscopy. The IrO{sub x} nanocrystals are confirmed by x-ray photoelectron spectroscopy. A large memory window of 3.0 V at a sweeping gate voltage of {+-}5 V and 7.2 V at a sweeping gate voltage of {+-} 8 V has been observed for the 1.5 nm-thick IrO{sub x} nano layer memory capacitors with a small equivalent oxide thickness of 8 nm. The electrons and holes are trapped in the core and annular regions of the IrO{sub x} nanocrystals, respectively, which is explained by Gibbs free energy. High electron and hole-trapping densities are found to be 1.5 x 10{sup 13}/cm{sup 2} and 2 x 10{sup 13}/cm{sup 2}, respectively, due to the small size and high-density of IrO{sub x} nanocrystals. Excellent program/erase endurance of >10{sup 6} cycles and good retention of 10{sup 4} s with a good memory window of >1.2 V under a small operation voltage of {+-} 5 V are obtained. A large memory size of >10 Tbit/sq. in. can be designed by using the IrO{sub x} nanocrystals. This study is not only important for the IrO{sub x} nanocrystal charge-trapping memory investigation but it will also help to design future metal nanocrystal flash memory.

36 MATERIALS SCIENCE↗

Influence of frequency tuning and double-frequency heating on ions extracted from an electron cyclotron resonance ion source

The electromagnetic field within the plasma chamber of an electron cyclotron resonance ion source (ECRIS) and the properties of the plasma waves affect the plasma properties and ion beam production. We have experimentally investigated the ''frequency tuning effect'' and ''double frequency heating'' on the CAPRICE ECRIS device. A traveling wave tube amplifier, two microwave sweep generators, and a dedicated experimental set-up were used to carry out experiments in the 12.5-16.5 GHz frequency range. During the frequency sweeps the evolution of the intensity and shape of the extracted argon beam were measured together with the microwave reflection coefficient. A range of different ion source parameter settings was used. Here we describe these experiments and the resultant improved understanding of these operational modes of the ECR ion source.

43 PARTICLE ACCELERATORS↗