Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sample geometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Heavy Isotope Composition of Oxygen in Zircon from Soil Sample 14163: Lunar Perspective of an Early Ocean on the Earth

Thirty oxygen analyses of a large (sub-millimetre) zircon grain from the lunar soil sample 14163 have been determined using CAMECA 1270 ion microprobe. The sample 14163 was returned form the Fra Mauro region by Apollo 14 mission. Zircon grain of 0.6-0.8 mm in size extracted from the sample was imaged using CL detector fitted to the Philips Electron Microscope in order to reveal internal structure. Oxygen isotopes have been analysed during two sessions. The first set of data was collected using the original mount where the grain was set in the resin attached to the glass slide. This resulted in the two complications: (i) standard zircon has to be analysed from the separate mount and (ii) the lunar zircon grain was rased in the holder compared to the standard. In order to investigate, if the elevated oxygen compositions observed during this session could have resulted from this difference in geometric configuration during the standard and sample analyses, the lunar zircon was extracted from the original mount, remounted with the standard chip in the new resin disk and reanalysed during the second session. All analyses made during the first session show delta O-18 values heavier than 6.0%. The second set of data has a wider spread of delta O-18 values with some values as low as 5.6%. Nevertheless, a half of observed delta O-18 values in this set is also higher than 6.0%. Slightly lighter oxygen compositions observed during the second session indicate possible dependence of measured delta O-18 values on the geometry of analysed samples. Presence of zircons with similar heavy oxygen isotope compositions on the Moon, which neither had liquid water or felic crust similar to that on the Earth nor ever developed regime similar to plate tectonics, suggests that other mechanisms can be responsible for elevated delta O-18 values in zircons. This implies that there is no support for the presence of an ocean on the surface of the early Earth and as the ocean appears to be an essential ingredient for the plate tectonics, there is no basis for belief that this mechanism was operating in the early history of the planet.

Nemchin, A. A.↗

Atmospheric deposition of {sup 7}Be by rain events, incentral Argentina

Beryllium-7 is a natural radionuclide that enters into the ecosystems through wet and dry depositions and has numerous environmental applications in terrestrial and aquatic ecosystems. Atmospheric wet deposition of {sup 7}Be was measured in central Argentina. Rain traps were installed (1 m above ground) and individual rain events have been collected. Rain samples were filtered and analyzed by gamma spectrometry. The gamma counting was undertaken using a 40%-efficient p-type coaxial intrinsic high-purity natural germanium crystal built by Princeton Gamma-Tech. The cryostat was made from electroformed high-purity copper using ultralow-background technology. The detector was surrounded by 50 cm of lead bricks to provide shielding against radioactive background. The detector gamma efficiency was determined using a water solution with known amounts of chemical compounds containing long-lived naturally occurring radioisotopes, {sup 176}Lu, {sup 138}La and {sup 40}K. Due to the geometry of the sample and its position close to the detector, the efficiency points from the {sup 176}Lu decay, had to be corrected for summing effects. The measured samples were 400 ml in size and were counted curing one day. The {sup 7}Be detection limit for the present measurements was as low as 0.2 Bq l{sup -1}. Thirty two rain events were sampled and analyzed (November 2006-May 2007). The measured values show that the events corresponding to low rainfall (<20 mm) are characterized by significantly higher activity concentrations (Bq l{sup -1}). The activity concentration of each individual event varied from 0.8 to 3.5 Bq l{sup -1}, while precipitations varied between 4 and 70 mm. The integrated activity by event of {sup 7}Be was fitted with a model that takes into account the precipitation amount and the elapsed time between two rain events. The integrated activities calculated with this model show a good agreement with experimental values.

54 ENVIRONMENTAL SCIENCES↗

Aerothermal Ground Testing of Flexible Thermal Protection Systems for Hypersonic Inflatable Aerodynamic Decelerators

Flexible TPS development involves ground testing and analysis necessary to characterize performance of the FTPS candidates prior to flight testing. This paper provides an overview of the analysis and ground testing efforts performed over the last year at the NASA Langley Research Center and in the Boeing Large-Core Arc Tunnel (LCAT). In the LCAT test series, material layups were subjected to aerothermal loads commensurate with peak re-entry conditions enveloping a range of HIAD mission trajectories. The FTPS layups were tested over a heat flux range from 20 to 50 W/cm with associated surface pressures of 3 to 8 kPa. To support the testing effort a significant redesign of the existing shear (wedge) model holder from previous testing efforts was undertaken to develop a new test technique for supporting and evaluating the FTPS in the high-temperature, arc jet flow. Since the FTPS test samples typically experience a geometry change during testing, computational fluid dynamic (CFD) models of the arc jet flow field and test model were developed to support the testing effort. The CFD results were used to help determine the test conditions experienced by the test samples as the surface geometry changes. This paper includes an overview of the Boeing LCAT facility, the general approach for testing FTPS, CFD analysis methodology and results, model holder design and test methodology, and selected thermal results of several FTPS layups.

Bruce, Walter E., III↗

Concurrent reaction-bonded joining and densification of additively manufactured silicon carbide by liquid silicon infiltration

Here, in this study, additive-manufactured silicon carbide preforms were joined and densified by reaction bonding via liquid silicon infiltration. The silicon carbide preforms were first printed by binder jetting additive manufacturing. To demonstrate concurrent joining and densification, two preforms with carbon or parchment papers at the interface were concurrently joined and infiltrated by liquid silicon. Results showed a robust interface with thicknesses ranging from 150 to 500 µm, depending on the paper type and the number of paper layers. High-energy synchrotron X-ray revealed that β-phase silicon carbide was formed inside the interface. Finally, two additively manufactured samples with complicated channel geometry were successfully joined. Energy dispersive spectroscopy of the interface of the channeled samples showed a consistent and robust joining. This concurrent approach of joining and densification enables efficiency improvement of fabricating silicon carbide parts with complicated geometries and widens geometry freedom for additive manufacturing of silicon carbide.

36 MATERIALS SCIENCE↗

Near-infrared spectral imaging of the female breast for quantitative oximetry in optical mammography

We present a hybrid continuous-wave, frequency-domain instrument for near-infrared spectral imaging of the female breast based on a tandem, planar scanning of one illumination optical fiber and one collection optical fiber configured in a transmission geometry. The spatial sampling rate of 25 points/cm{sup 2} is increased to 400 points/cm{sup 2} by postprocessing the data with a 2D cubic spline interpolation. We then apply a previously developed spatial second-derivative algorithm to an edge-corrected intensity image (N-image) to enhance the visibility and resolution of optical inhomogeneities in breast tissue such as blood vessels and tumors. The spectral data at each image pixel consist of 515-point spectra over the 650-900 nm wavelength range, thus featuring a spectral density of two data points per nanometer. We process the measured spectra with a paired-wavelength spectral analysis method to quantify the oxygen saturation of detected optical inhomogeneities, under the assumption that they feature a locally higher hemoglobin concentration. Our initial measurements on two healthy human subjects have generated high-resolution optical mammograms displaying a network of blood vessels with values of hemoglobin saturation typically falling within the 60%-95% range, which is physiologically reasonable. This approach to spectral imaging and oximetry of the breast has the potential to efficiently exploit the high intrinsic contrast provided by hemoglobin in breast tissue and to contribute a useful tool in the detection, diagnosis, and monitoring of breast pathologies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Defect Characterization Using Positron Annihilation Spectroscopy on Laser-Ablated Surfaces

In recent years, short, pulsed laser ablation has been gaining popularity for machining small-scale test geometries from bulk samples and for efficient serial sectioning. These laser-based techniques are being added to the toolbox in material science, which makes it necessary to understand the changes in the material that occur from the laser–material interaction. Positron annihilation spectroscopy is a unique, nondestructive technique to investigate small defects in materials difficult to investigate by other tools. In this work, Doppler broadening and positron lifetime annihilation spectroscopy are utilized to help quantify the damage in materials treated with short, pulsed lasers. Using a femtosecond laser on single crystal silicon, this manuscript shows that clusters of vacancy-like defects and small voids increase systematically with laser power. Lastly, the damage induced by the laser can also reach to micrometer depths.

36 MATERIALS SCIENCE↗

Laser notching ceramics for reliable fracture toughness testing

A new method for notching ceramics was developed using a picosecond laser for fracture toughness testing of alumina samples. The test geometry incorporated a single-edge-V-notch that was notched using picosecond laser micromachining. This method has been used in the past for cutting ceramics, and is known to remove material with little to no thermal effect on the surrounding material matrix. This study showed that laser-assisted-machining for fracture toughness testing of ceramics was reliable, quick, and cost effective. In order to assess the laser notched single-edge-V-notch beam method, fracture toughness results were compared to results from other more traditional methods, specifically surface-crack in flexure and the chevron notch bend tests. Lastly, the results showed that picosecond laser notching produced precise notches in post-failure measurements, and that the measured fracture toughness results showed improved consistency compared to traditional fracture toughness methods.

36 MATERIALS SCIENCE↗

Comparison of NBG-18, NBG-17, IG-110 and IG-11 oxidation kinetics in air

In this paper, the oxidation rates of several nuclear-grade graphites, NBG-18, NBG-17, IG-110 and IG-11, were measured in air using thermogravimetry. Kinetic parameters and oxidation behavior for each grade were compared by coke type, filler grain size and microstructure. The thickness of the oxidized layer for each grade was determined by layer peeling and direct density measurements. The results for NBG-17 and IG-11 were compared with those available in the literature and our recently reported results for NBG-18 and IG-110 oxidation in air. The finer-grained graphites IG-110 and IG-11 were more oxidized than medium-grained NBG-18 and NBG-17 because of deeper oxidant penetration, higher porosity and higher probability of available active sites. Variation in experimental conditions also had a marked effect on the reported kinetic parameters by several studies. Finally, kinetic parameters such as activation energy and transition temperature were sensitive to air flow rates as well as sample size and geometry.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Fabrication and characterization of lithium manganese nickel oxide sputtered thin film cathodes for lithium-ion batteries

Li-rich and stoichiometric Li1Mn1.5Ni0.5O4 (LMNO) cathode films have been prepared by magnetron sputtering. Sputtering from a Li stoichiometric target yields Li-rich films composed of spinel, layered and monoclinic phases. Films obtained from a Li deficient target are mostly made of a spinel phase and little layered material. The resulting cathode thin films have good capacity retention and very high rate capability. The reaction mechanism has been investigated by XRD and HRTEM and evidences the reversible formation of a spinel phase, as is also found for the powder samples. The film geometry enables to understand the effect of coatings (ZnO or LiPON). Coating high voltage cathodes reduces the coulombic losses but at the price of rate performance. Nonetheless, these coated sputtered electrode thin films offer a higher rate capability than other LMNO thin films obtained by other physical vapor deposition techniques.

25 ENERGY STORAGE↗

Optimizing the spatial resolution and gamma discrimination of SiPM-based Anger cameras

SiPM Anger cameras have been designed for use as 2-dimensional thermal neutron detectors for scientific applications such as at single crystal diffraction instruments. These cameras utilize a neutron sensitive scintillator and an array of SiPM photosensors, separated by a light spreading glass. While this optics package is very effective at detecting and positioning neutrons, it is also sensitive to gamma rays, which are a source of unwanted noise. In this work, we underwent a search of scintillator and spreader glass thicknesses to determine the optimal combination for maximizing spatial resolution. Both experimental results and GEANT4 simulations are presented. Further, to address the issue of gamma ray detection, we have also designed and presented a multi-layer scintillator that reduces the amount of scintillation light produced via gamma-ray energy deposition, allowing for easier pulse-height discrimination. A sample of this geometry has been produced that results in a factor of 2 improvement over an equivalent thickness monolithic scintillator.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Toward Metal–Organic Framework-Based Solar Cells: Enhancing Directional Exciton Transport by Collapsing Three-Dimensional Film Structures

Owing to their ability to act as light-harvesting scaffolds, porphyrin-containing metal-organic frameworks (MOFs) are in the forefront of research on the application of highly ordered molecular materials to problems in solar-energy conversion. In this work, solvent-assisted linker exchange (SALE) is performed on a pillared paddlewheel porphyrin containing MOF thin film to collapse a 3D framework to a 2D framework. The change in dimensionality of the framework is confirmed by a decrease in the film thickness, the magnitude of which is in agreement with crystallographic parameters for related bulk materials. Furthermore, NMR spectroscopy performed on the digested sample suggests a similar change in geometry is achieved in bulk MOF samples. The decreased distance between the porphyrin chromophores in the 2D MOF film compared to the 3D film results in enhanced energy transfer through the film. The extent of energy transport was probed by assembling MOF thin film where the outermost layers are palladium porphyrin (P2) units, which act as energy traps and fluorescence quenchers. Steady-state emission spectroscopy together with time-resolved emission spectroscopy indicates that excitons can travel through about 9-11 layers (porphyrin layers) in 2D films, whereas in 3D films energy transfer occurs through no more than about 6-8 layers. The results are difficult to understand if only changes in MOF interlayer spacing are considered but become much more understandable if dipole-dipole coupling distances are considered.

Goswami, Subhadip↗

Nanopipettes: probes for local sample analysis

Nanopipettes (pipettes with diameters <1 μm) were explored as pressure-driven fluid manipulation tools for sampling nanoliter volumes of fluids. The fundamental behavior of fluids confined in the narrow channels of the nanopipette shank was studied to optimize sampling volume and probe geometry. This method was utilized to collect nanoliter volumes (<10 nL) of sample from single Allium cepa cells and live Drosophila melanogaster first instar larvae. Matrix assisted laser desorption/ionization-mass spectrometry (MALDI-MS) was utilized to characterize the collected sample. The use of nanopipettes for surface sampling of mouse brain tissue sections was also explored. Lipid analyses were performed on mouse brain tissues with spatial resolution of sampling as small as 50 μm. Nanopipettes were shown to be a versatile tool that will find further application in studies of sample heterogeneity and population analysis for a wide range of samples.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Portable UV-visible spectrometer for measuring absorbance and dichroism of Langmuir monolayers at air-water interfaces.

An UV-visible spectrometer for measuring absorbance and dichroism of Langmuir monolayers under in situ conditions is described. The spectrometer utilizes a stand-alone multipass sensor, which is placed in a Langmuir trough and coupled with light source and spectrometer head via fiber optics. Implementation of the multipass scheme in the absorbance sensor makes it possible to obtain reliable quantitative spectroscopic data of the Langmuir monolayers with absorbance as low as 1 mOD. Such high sensitivity makes the developed sensor very useful for UV-visible spectral studies of a wide variety of chromophores. The new technique was applied to several model systems: fatty acid monolayers containing amphiphilic dyes DiI or BODIPY and also a monolayer of a synthetic amphiphilic porphyrin-binding peptide BBC16. Implementation of UV-visible absorbance spectroscopy measurements in situ together with x-ray scattering technique was used to confirm the bound state of the chromophore, and determine the exact position of the latter in the peptide matrix. Fiber optics design of the spectrometer provides portability and compatibility with other experimental techniques making it possible to study samples with a geometry unsuitable for conventional spectroscopic measurements and located in experimental environments with spatial limitations, such as synchrotron x-ray scattering stations.

36 MATERIALS SCIENCE↗

The dedicated QEXAFS facility at the SLS: Performance and Scientific Opportunities

The SuperXAS beamline at the Swiss Light Source (SLS) features a permanently installed monochromator for quick scanning EXAFS (QEXAFS) spectroscopy in series with a conventional double crystal monochromator (DCM). All installed optical components like collimating and focussing mirrors can be used by both devices. The remote exchange of the monochromators is possible in less than five minutes while maintaining the beam geometry on the sample. The QEXAFS system allows fast absorption scans down to the millisecond range for the investigation of time dependent processes. Using a Si(111) channel cut crystal the energy range from 5-16 keV can be covered, with a Si(311) cut the range 9.5-30 keV. Usually a quick scanning interval of 0.1 deg. - 2 deg. in Bragg angle is selected, thus covering XANES, full EXAFS or multiple edge scans of e.g. all L-edges of a heavy element. Up to about 80 spectra per second can be collected, corresponding to a time resolution of 12.5 ms. The high intensity of the beamline even facilitates fluorescence measurements on dilute samples.

43 PARTICLE ACCELERATORS↗

Prediction of Debye-Scherrer diffraction patterns in arbitrarily strained samples

The prediction of Debye-Scherrer diffraction patterns from strained samples is typically conducted in the small strain limit. Although valid for small deviations from the hydrostat (such as the conditions of finite strength typically observed in diamond anvil cells) this assertion is likely to fail for the large strain anisotropies (often of order 10% in normal strain) found in uniaxially loaded dynamic compression experiments. In this paper, we derive a general form for the (θ{sub B},ϕ) dependence of the diffraction for an arbitrarily deformed polycrystalline sample in any geometry, and of any crystal symmetry. We show that this formula is consistent with ray traced diffraction for highly strained computationally generated polycrystals, and that the formula shows deviations from the widely used small strain solutions previously reported.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Adding diffuse reflectance infrared Fourier transform spectroscopy capability to extended x-ray-absorption fine structure in a new cell to study solid catalysts in combination with a modulation approach

We describe a novel cell used to combine in situ transmission X-ray absorption spectroscopy (XAS) with diffuse reflectance infrared Fourier transform spectroscopy (DRIFTS) in a single experiment. The novelty of the cell design compared to current examples is that both radiations are passed through an X-ray and IR transparent window in direct contact with the sample. This innovative geometry also offers a wide surface for IR collection. In order to avoid interference from the crystalline IR transparent materials (e.g., CaF{sub 2}, MgF{sub 2}, diamond) a 500 μm carbon filled hole is laser drilled in the center of a CaF{sub 2} window. The cell is designed to represent a plug flow reactor, has reduced dead volume in order to allow for fast exchange of gases and is therefore suitable for experiments under fast transients, e.g., according to the concentration modulation approach. High quality time-resolved XAS and DRIFTS data of a 2 wt.% Pt/Al{sub 2}O{sub 3} catalyst are obtained in concentration modulation experiments where CO (or H{sub 2}) pulses are alternated to O{sub 2} pulses at 150 °C. We show that additional information can be obtained on the Pt redox dynamic under working conditions thanks to the improved sensitivity given by the modulation approach followed by Phase Sensitive Detection (PSD) analysis. It is anticipated that the design of the novel cell is likely suitable for a number of other in situ spectroscopic and diffraction methods.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Photoelectric properties of the metamorphic InAs/InGaAs quantum dot structure at room temperature

We present the study of optical and photoelectric properties of InAs quantum dots (QDs) grown on a metamorphic In{sub 0.15}Ga{sub 0.85}As buffer layer: such nanostructures show efficient light emission in the telecom window at 1.3 μm (0.95 eV) at room temperature. We prepared a sample with vertical geometry of contacts isolated from the GaAs substrate. The structure is found to be photosensitive in the spectral range above 0.9 eV at room temperature, showing distinctive features in the photovoltage and photocurrent spectra attributed to QDs, InAs wetting layer, and In{sub 0.15}Ga{sub 0.85}As metamorphic buffer, while a drop in the photoelectric signal above 1.36 eV is related to the GaAs layer. No effect of defect centers on the photoelectrical properties is found, although they are observed in the absorption spectrum. We conclude that metamorphic QDs have a low amount of interface-related defects close to the optically active region and charge carriers can be effectively collected into InAs QDs.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Characterization of LiMn 2 O 4 cathodes by electrochemical strain microscopy

Electrochemical strain microscopy (ESM) is a scanning probe microscopy(SPM) method in which the local electrodiffusion is probed via application of AC voltage to the SPM tip and registration of resulting electrochemical strain. In this study, we implemented ESM to measure local strain in bulk LiMn 2 O 4 cathodes of a commercial Li-battery in different states of charge to investigate distribution of Li-ion mobility and concentration. Ramped AC ESM imaging and voltage spectroscopy were used to find the most reliable regime of measurements allowing separating and diminishing different contributions to ESM. This is not a trivial task due to complex geometry of the sample and various obstacles resulting in less predictable contributions of different origins into ESM response: electrostatic tip–surface interactions, charge injection, electrostriction, and flexoelectricity. Finally, understanding and control of these contributions is an important step towards quantitative interpretation of ESM data.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗