Search NASA⌕ Search

SEARCH · Search NASA

Results for “Scanning techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

SU-F-T-163: Improve Proton Therapy Efficiency: Report of a Workshop

Purpose: The technology of proton therapy, especially the pencil beam scanning technique, is evolving very quickly. However, the efficiency of proton therapy seems to lag behind conventional photon therapy. The purpose of the abstract is to report on the findings of a workshop on improvement of QA, planning and treatment efficiency in proton therapy. Methods: A panel of physicists, clinicians, and vendor representatives from over 18 institutions in the United States and internationally were convened in Knoxville, Tennessee in November, 2015. The panel discussed several topics on how to improve proton therapy efficiency, including 1) lean principle and failure mode and effects analysis, 2) commissioning and machine QA, 3) treatment planning, optimization and evaluation, 4) patient positioning and IGRT, 5) vendor liaison and machine availability, and 6) staffing, education and training. Results: The relative time needed for machine QA, treatment planning & check in proton therapy was found to range from 1 to 2.5 times of that in photon therapy. Current status in proton QA, planning and treatment was assessed. Key areas for efficiency improvement, such as elimination of unnecessary QA items or steps and development of efficient software or hardware tools, were identified. A white paper to summarize our findings is being written. Conclusion: It is critical to improve efficiency by developing reliable proton beam lines, efficient software tools on treatment planning, optimization and evaluation, and dedicated proton QA device. Conscious efforts and collaborations from both industry leaders and proton therapy centers are needed to achieve this goal and further advance the technology of proton therapy.

60 APPLIED LIFE SCIENCES↗

MO-A-201-00: A Cliff’s Notes Version of Proton Therapy

Proton therapy is a rapidly growing modality in the fight against cancer. From a high-level perspective the process of proton therapy is identical to x-ray based external beam radiotherapy. However, this course is meant to illustrate for x-ray physicists the many differences between x-ray and proton based practices. Unlike in x-ray therapy, proton dose calculations use CT Hounsfield Units (HU) to determine proton stopping power and calculate the range of a beam in a patient. Errors in stopping power dominate the dosimetric uncertainty in the beam direction, while variations in patient position determine uncertainties orthogonal to the beam path. Mismatches between geometric and range errors lead to asymmetric uncertainties, and so while geometric uncertainties in x-ray therapy are mitigated through the use of a Planning Target Volume (PTV), this approach is not suitable for proton therapy. Robust treatment planning and evaluation are critical in proton therapy, and will be discussed in this course. Predicting the biological effect of a proton dose distribution within a patient is also a complex undertaking. The proton therapy community has generally regarded the Radiobiological Effectiveness (RBE) of a proton beam to be 1.1 everywhere in the patient, but there are increasing data to suggest that the RBE probably climbs higher than 1.1 near the end of a proton beam when the energy deposition density increases. This lecture will discuss the evidence for variable RBE in proton therapy and describe how this is incorporated into current proton treatment planning strategies. Finally, there are unique challenges presented by the delivery process of proton therapy. Many modern systems use a spot scanning technique which has several advantages over earlier scattered beam designs. However, the time dependence of the dose deposition leads to greater concern with organ motion than with scattered protons or x-rays. Image guidance techniques in proton therapy may also differ from standard x-ray approaches, due to equipment design or the desire to maximize efficiency within a high-cost proton therapy treatment room. Differences between x-ray and proton therapy delivery will be described. Learning Objectives: Understand how CT HU are calibrated to provide proton stopping power, and the sources of uncertainty in this process. Understand why a PTV is not suitable for proton therapy, and how robust treatment planning and evaluation are used to mitigate uncertainties. Understand the source and implications of variable RBE in proton therapy Learn about proton specific challenges and approaches in beam delivery and image guidance Jon Kruse has a research grant from Varian Medical Systems related to proton therapy treatment plannning.; J. Kruse, Jon Kruse has a research grant with Varian Medical Systems related to proton therapy planning.

60 APPLIED LIFE SCIENCES↗

MO-A-201-01: A Cliff’s Notes Version of Proton Therapy

Proton therapy is a rapidly growing modality in the fight against cancer. From a high-level perspective the process of proton therapy is identical to x-ray based external beam radiotherapy. However, this course is meant to illustrate for x-ray physicists the many differences between x-ray and proton based practices. Unlike in x-ray therapy, proton dose calculations use CT Hounsfield Units (HU) to determine proton stopping power and calculate the range of a beam in a patient. Errors in stopping power dominate the dosimetric uncertainty in the beam direction, while variations in patient position determine uncertainties orthogonal to the beam path. Mismatches between geometric and range errors lead to asymmetric uncertainties, and so while geometric uncertainties in x-ray therapy are mitigated through the use of a Planning Target Volume (PTV), this approach is not suitable for proton therapy. Robust treatment planning and evaluation are critical in proton therapy, and will be discussed in this course. Predicting the biological effect of a proton dose distribution within a patient is also a complex undertaking. The proton therapy community has generally regarded the Radiobiological Effectiveness (RBE) of a proton beam to be 1.1 everywhere in the patient, but there are increasing data to suggest that the RBE probably climbs higher than 1.1 near the end of a proton beam when the energy deposition density increases. This lecture will discuss the evidence for variable RBE in proton therapy and describe how this is incorporated into current proton treatment planning strategies. Finally, there are unique challenges presented by the delivery process of proton therapy. Many modern systems use a spot scanning technique which has several advantages over earlier scattered beam designs. However, the time dependence of the dose deposition leads to greater concern with organ motion than with scattered protons or x-rays. Image guidance techniques in proton therapy may also differ from standard x-ray approaches, due to equipment design or the desire to maximize efficiency within a high-cost proton therapy treatment room. Differences between x-ray and proton therapy delivery will be described. Learning Objectives: Understand how CT HU are calibrated to provide proton stopping power, and the sources of uncertainty in this process. Understand why a PTV is not suitable for proton therapy, and how robust treatment planning and evaluation are used to mitigate uncertainties. Understand the source and implications of variable RBE in proton therapy Learn about proton specific challenges and approaches in beam delivery and image guidance Jon Kruse has a research grant from Varian Medical Systems related to proton therapy treatment plannning.; J. Kruse, Jon Kruse has a research grant with Varian Medical Systems related to proton therapy planning.

60 APPLIED LIFE SCIENCES↗

MO-FG-CAMPUS-TeP3-05: Limitations of the Dose Weighted LET Concept for Intensity Modulated Proton Therapy in the Distal Falloff Region and Beyond

Purpose: Dose-weighted linear energy transfer (dLET) has been shown to be useful for the analysis of late effects in proton therapy. This study presents the results of the testing of the dLET concept for intensity modulated proton therapy (IMPT) with a discrete spot scanning beam system without use of an aperture or compensator (AC). Methods: IMPT (no AC) and broad beams (BB) with (AC) were simulated in the TOPAS and FLUKA code systems. Information from the independently tested Monte Carlo Damage Simulation (MCDS) was integrated into the FLUKA code systems to account for spatial variations in the RBE for protons and other light ions using an endpoint of DNA double strand break (DSB) induction. Results: The proton spectra for IMPT beams at the depths beyond the distal edge contain a tail of high energy protons up to 100 MeV. The integral from the tail is compatible with the number of 5–8 MeV protons at the tip of the Bragg peak (BP). The dose averaged energy (dEav) decreases to 7 MeV at the tip of (BP) and then increases to about 15 MeV beyond the distal edge. Neutrons produced in the nozzle are two orders of magnitude higher for BB with AC than for IMPT in low energy part of the spectra. The dLET values beyond of the distal edge of the BP are 5 times larger for the IMPT than for BB with the AC. Contrarily, negligible differences are seen in the RBE estimates for IMPT and BB with AC beyond the distal edge of the BP. Conclusion: The analysis of late effects in IMPT with a spot scanning and double scattering or scanning techniques with AC may requires both dLET and RBE as quantitative parameters to characterize effects beyond the distal edge of the BP.

60 APPLIED LIFE SCIENCES↗

Three dimensions, two microscopes, one code: Automatic differentiation for x-ray nanotomography beyond the depth of focus limit

Conventional tomographic reconstruction algorithms assume that one has obtained pure projection images, involving no within-specimen diffraction effects nor multiple scattering. Advances in x-ray nanotomography are leading toward the violation of these assumptions, by combining the high penetration power of x-rays, which enables thick specimens to be imaged, with improved spatial resolution that decreases the depth of focus of the imaging system. We describe a reconstruction method where multiple scattering and diffraction effects in thick samples are modeled by multislice propagation and the 3D object function is retrieved through iterative optimization. We show that the same proposed method works for both full-field microscopy and for coherent scanning techniques like ptychography. Our implementation uses the optimization toolbox and the automatic differentiation capability of the open-source deep learning package TensorFlow, demonstrating a straightforward way to solve optimization problems in computational imaging with flexibility and portability.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Synthesis and characterization of three-dimensional flower-like tin dioxide-based structures

Three-dimensional flower-like SnO{sub 2}-based structures have been produced by the alkaline hydrothermal treatment of t-SnO{sub 2} powder with no additive and in the presence of aminoterephthalic acid (ATPA). The synthesis products have been characterized by a variety of physicochemical techniques (scanning electron microscopy, transmission electron microscopy, Raman and IR spectroscopies, X-ray diffraction, and others). The results demonstrate that raising the ATPA concentration in the reaction mixture changes the morphology of the materials and leads to the SnO{sub 2} → SnO{sub 2}/Sn{sub 3}O{sub 4} → Sn{sub 3}O{sub 4} phase transformation in the structures through the formation of SnO{sub x} nonstoichiometric tin oxide phases with 1 < x < 2. Hydrothermal treatment of the starting reagents in the presence of ≤75 wt % ATPA leads to the formation of hierarchical structures dominated by a nonstoichiometric tin oxide, which is thermally unstable at t ≥ 500°C. The morphology and phase composition of the synthesized structures have been shown to have a significant effect on the electronic conductivity of the material.

36 MATERIALS SCIENCE↗

Formation of Cu{sub 2}O and ZnO Crystal Layers by Magnetron Assisted Sputtering and Their Optical Characterization

Copper (I) oxide and zinc oxide films are formed on silicon and glassy quartz substrates by magnetron assisted sputtering. The thickness of the films is tens and hundreds of nanometers. The films are grown at different substrate temperatures and different oxygen pressures in the working chamber. The film samples are studied by the X-ray diffraction technique, scanning electron microscopy, and optical methods. It is established that an increase in the substrate temperature yields a change in the surface morphology of copper (I) oxide films towards the formation of well-pronounced crystallites. The reflectance and Raman spectra suggest that the quality of such films is close to that of bulk Cu{sub 2}O crystals produced by the oxidation of copper. As concerns ZnO films, an increase in the substrate temperature and an increase in the partial oxygen pressure make it possible to produce films, for which a sharp exciton structure is observed in the reflectance spectra and the emission of excitons bound at donors is observed in the luminescence spectra.

36 MATERIALS SCIENCE↗

Polymer Composition Influence on Optical Properties of Laser-Generated Au Nanoparticles Based Nanocomposites

Au nanoparticles (AuNPs) stable colloid solution were prepared by laser ablation and fragmentation in liquid monomer isodecyl acrylate (IDA). Sizes of obtained nanoparticles were determined by scanning transmission electron microscopy (STEM) and were about 20 nm. Nanocomposites films were prepared from obtained stable colloid solution by UV-photocuring. To prepare solid polymer films different crosslinking diacrylates were used. Third-order nonlinear optical responses of prepared nanomaterials with different polymer matrix compositions were estimated by z-scan technique and compared.

36 MATERIALS SCIENCE↗

Nonlinear Optical Properties of CdS/ZnS Quantum Dots in a High-Molecular-Weight Polyvinylpyrrolidone Matrix

Sols containing core/shell CdS/ZnS semiconductor quantum dots are synthesized and their nonlinear properties, which are interesting for a large variety of applications in nanophotonics, are studied. The quantum dots produced are smaller in dimensions than the exciton Bohr radius and, therefore, exhibit a well-pronounced quantum-confinement effect. The nonlinear optical properties of low-concentration sols are studied upon exposure to laser pulses with an emission wavelength of 532 nm and a duration of 5 ns by the z-scan technique. The dependences of nonlinear optical coefficients on the concentration of CdS/ZnS quantum dots are obtained. The intensity dependence of two-photon absorption coefficients is presented. The dependence determines the boundary of the influence of high-order nonlinearities on the nonlinear transmittance of the samples. The mechanisms of optical limitation exhibited by sols, specifically, two-photon absorption, nonlinear refraction, and nonlinear scattering are discussed.

36 MATERIALS SCIENCE↗

Horizontal-Velocity and Variance Measurements in the Stable Boundary Layer Using Doppler Lidar: Sensitivity to Averaging Procedures

Quantitative data on turbulence variables aloft--above the region of the atmosphere conveniently measured from towers--has been an important but difficult measurement need for advancing understanding and modeling of the stable boundary layer (SBL). Vertical profiles of streamwise velocity variances obtained from NOAA’s High Resolution Doppler Lidar (HRDL), which have been shown to be numerically equivalent to turbulence kinetic energy (TKE) for stable conditions, are a measure of the turbulence in the SBL. In the present study, the mean horizontal wind component U and variance σu2 were computed from HRDL measurements of the line-of-sight (LOS) velocity using a technique described in Banta, et al. (2002). The technique was tested on datasets obtained during the Lamar Low-Level Jet Project (LLLJP) carried out in early September 2003, near the town of Lamar in southeastern Colorado. This paper compares U with mean wind speed obtained from sodar and sonic anemometer measurements. It then describes several series of averaging tests that produced the best correlation between TKE calculated from sonic anemometer data at several tower levels and lidar measurements of horizontal velocity variance σu2. The results show high correlation (0.71-0.97) of the mean U and average wind speed measured by sodar and in-situ instruments, independent of sampling strategies and averaging procedures. Comparison of estimates of variance, on the other hand, proved sensitive to both the spatial and temporal averaging techniques.

54 ENVIRONMENTAL SCIENCES↗

Data processing methods and data acquisition for samples larger than the field of view in parallel-beam tomography

Parallel-beam tomography systems at synchrotron facilities have limited field of view (FOV) determined by the available beam size and detector system coverage. Scanning the full size of samples bigger than the FOV requires various data acquisition schemes such as grid scan, 360-degree scan with offset center-of-rotation (COR), helical scan, or combinations of these schemes. Though straightforward to implement, these scanning techniques have not often been used due to the lack of software and methods to process such types of data in an easy and automated fashion. The ease of use and automation is critical at synchrotron facilities where using visual inspection in data processing steps such as image stitching, COR determination, or helical data conversion is impractical due to the large size of datasets. Here, we provide methods and their implementations in a Python package, named Algotom, for not only processing such data types but also with the highest quality possible. The efficiency and ease of use of these tools can help to extend applications of parallel-beam tomography systems.

36 MATERIALS SCIENCE↗

Gamma-radiation-induced negative nonlinear absorption in quartz glass

The effect of ionizing radiation on the nonlinear optical properties of materials needs to be considered for applications that employ high-power laser pulses in extreme radiation environments. The Heraeus Infrasil302 optical quartz glass was irradiated by gamma rays, and its nonlinear absorption was measured using the open-aperture Z-scan technique with nanosecond laser pulses. Irradiation results in a negative nonlinear absorption coefficient whose magnitude increases with irradiation dose. Nonlinear absorption coefficients of -0.78, -1.14, -1.29, and -1.88~ × ~10 -13 m/W are measured for gamma doses of 600 krad, 1.2 Mrad, 3.6 Mrad, and 10 Mrad, respectively. Thermal annealing restores the optical properties of quartz-glass to their unirradiated values. It is suggested that metallic impurities introduced by the manufacturing process have a role in inducing saturated absorption in irradiated quartz glass, which manifests as negative nonlinear absorption coefficient, and is demonstrated by comparing Infrasil302 quartz results to equivalent irradiated measurements for Spectrosil2000 quartz.

07 ISOTOPE AND RADIATION SOURCES↗

Analysis of citation networks as a new tool for scientific research

The rapid growth of scientific publications necessitates new methods to understand the direction of scientific research within fields of study, ascertain the importance of particular groups, authors, or institutions, compute metrics that can determine the importance (centrality) of particular seminal papers, and provide insight into the social (collaboration) networks that are present. We present one such method based on analysis of citation networks, using the freely available CiteSpace Program. We use citation network analysis on three examples, including a single material that has been widely explored in the last decade (BiFeO 3 ), two small subfields with a minimal number of authors (flexoelectricity and Kitaev physics), and a much wider field with thousands of publications pertaining to a single technique (scanning tunneling microscopy). Interpretation of the analysis and key insights into the fields, such as whether the fields are experiencing resurgence or stagnation, are discussed, and author or collaboration networks that are prominent are determined. Such methods represent a paradigm shift in our way of dealing with the large volume of scientific publications and could change the way literature searches and reviews are conducted, as well as how the impact of specific work is assessed.

97 MATHEMATICS AND COMPUTING↗

Retuning the DARHT Axis-II Linear Induction Accelerator

The Dual-Axis Radiographic Hydrodynamic Test (DARHT) facility uses bremsstrahlung radiation source spots produced by the focused electron beams from two linear induction accelerators (LIAs) to radiograph large hydrodynamic experiments driven by high explosives. The Axis-II 1.7-kA, 1600-ns beam pulse is transported through the LIA by the magnetic field from 91 solenoids as it is accelerated to ~16.5 MeV. The magnetic field produced by the solenoids and 80 steering dipole pairs for a given set of magnet currents is known as the “tune” of the accelerator [1]. From June, 2013 through September, 2014 a single tune was used. This tune was based on measurements of LIA element positions made over several years [2], and models of solenoidal fields derived from actual field measurements [3] [4]. Based on the focus scan technique, changing the tune of the accelerator and downstream transport had no effect on the beam emittance, to within the uncertainties of the measurement. Beam sizes appear to have been overestimated in all prior measurements because of the low magnification of the imaging system. This has resulted in overestimates of emittance by ~50%. The high magnification imaging should be repeated with the old tune for direct comparison with the new tune. High magnification imaging with the new accelerator tune should be repeated after retuning the downstream to produce a much more symmetric beam to reduce the uncertainty of this measurement. Thus, these results should be considered preliminary until we can effect a new tune to produce symmetric spots at our imaging station, for high magnification images.

43 PARTICLE ACCELERATORS↗

Radiation-Induced Modifications in Copper Oxide Growth

Radiation-induced effects and their influence on oxidation processes were evaluated for their use as a forensic tool for special nuclear material (SNM). A beam of 10 MeV Au³⁺ ions was used to mimic the accumulation of microstructural damage from self-irradiation through the decay of radionuclides. Several copper samples were irradiated as suitable surrogate materials at 200 °C with a flux of 1x10¹² ions/cm·s to damage levels of 5, 10, and 15 displacements per atom (dpa). This corresponds to about 50, 100, and 150 years, respectively, of accumulated α-decay damage in a PuGa alloy assuming a damage rate of 0.1 dpa/year. After irradiation, all samples were exposed to an accelerated aging process induced by thermal treatment at 350 °C for 1 hour in air. This resulted in the growth of a mixed oxide layer (Cu₂O and CuO) which was characterized in detail using several complementary analytical techniques: Scanning Electron Microscopy, Raman spectroscopy, Synchrotron X-ray diffraction (transmission mode), and Grazing Incidence X-ray diffraction. The oxide layer growth of irradiated Cu at 350°C is distinctly modified as a result of the ion irradiation. Most notably, the growth of the CuO phase is suppressed with increasing radiation damage on the Cu substrate, and structural changes occurred in the Cu₂O phase. These results indicate that damage from self-irradiation over time can cause quantifiable modifications in the oxidation process of metals that could be harnessed for their use as a novel forensic tool.

36 MATERIALS SCIENCE↗

Bunch Length Measurements at the CEBAF Injector at 130 kV

In this work, we investigated the evolution in bunch length of beams through the CEBAF injector for 8?770 fC charge per bunch. Using the software General Particle Tracer (GPT), we have simulated beams through the beamline of the CEBAF injector to predict bunch lengths at the location of a beam chopper for comparison with measurements and to validate the model. We performed these simulations with the existing injector using a 130 kV gun voltage. The mea- surements have been done using chopper phase scanning technique for two injector laser drive frequencies 499 MHz and 249.5 MHz. Acknowledgement This material is based upon work supported by the U.S. Department of Energy, Office of Science, Office of Nuclear Physics under contract DE-AC05-06OR23177.

Pokharel, S.↗

Benchmarking Microscale Ductility Measurements (Final Report of the Project DE-NE0008799)

Conventional macroscale experimentation is generally considered to be straightforward with few limitations. Conversely, micro/nanoscale experimentation presents numerous challenges in loading device design, sample preparation and handling, as well as accurate understanding of grain size and local texture effects on recorded measurements. Despite these challenges, nanopillar compression, MEMs based micro-tension, and nanoindentation approaches have been able to provide fundamental contributions to the understanding of material behavior at small lengthscales. However, the overarching shortcoming of these micro/nanoscale experimentation approaches, is the inability to directly translate measurements evaluated at the nm and µm length scales (e.g., hardness) to macroscale tensile material behavior (i.e., elastic modulus, yield strength, and ductility). The objectives of the proposed study are, 1) to establish best practices for obtaining tensile microscale ductility measurements, and 2) to validate methodologies to for comparing microscale ductility measurements to macroscale ductility measurements. In order to achieve these objectives, a multi-lengthscale, multi-temperature testing protocol and simulation framework are executed first on copper as a model material to validate the following approach, and second on reactor grade Zircaloy-2. Experiments are conducted on specimens extracted from the same test piece to ensure nominally identical grain size and texture from specimens to specimen. Motivated by the need to isolate the contribution of size-effects on obtained mechanical property measurements, specimens are manufactured with thicknesses at the micro- (1-10 µm), meso- (10-100's µm), and macroscales (sub-sized ASTM E8). In-situ full-field deformation techniques (scanning electron microscopy (SEM) grid methods and optical DIC) are incorporated into testing at each specimen length-scale to capture plasticity localization and evolution. Experimental testing for all specimens is conducted at both room temperature and elevated temperatures to probe the role of thermal activation on plastic deformation accommodation processes. Simulation efforts focus on examining the mechanical behavior of microscale specimens using a finite element approach with explicitly resolved grain morphologies, and an embedded crystal plasticity model. The cost-efficient implementation method allows for the modeling of a statistically significant number of both real (i.e., digital twin) and generated microstructures to obtain an understanding of the interrelationships between specimen microstructure and geometric variables (grain size, texture, specimen geometry, etc.) on microscale mechanical behavior.

36 MATERIALS SCIENCE↗

Imaging doped silicon test structures using low energy electron microscopy.

This document is the final SAND Report for the LDRD Project 105877 - 'Novel Diagnostic for Advanced Measurements of Semiconductor Devices Exposed to Adverse Environments' - funded through the Nanoscience to Microsystems investment area. Along with the continuous decrease in the feature size of semiconductor device structures comes a growing need for inspection tools with high spatial resolution and high sample throughput. Ideally, such tools should be able to characterize both the surface morphology and local conductivity associated with the structures. The imaging capabilities and wide availability of scanning electron microscopes (SEMs) make them an obvious choice for imaging device structures. Dopant contrast from pn junctions using secondary electrons in the SEM was first reported in 1967 and more recently starting in the mid-1990s. However, the serial acquisition process associated with scanning techniques places limits on the sample throughput. Significantly improved throughput is possible with the use of a parallel imaging scheme such as that found in photoelectron emission microscopy (PEEM) and low energy electron microscopy (LEEM). The application of PEEM and LEEM to device structures relies on contrast mechanisms that distinguish differences in dopant type and concentration. Interestingly, one of the first applications of PEEM was a study of the doping of semiconductors, which showed that the PEEM contrast was very sensitive to the doping level and that dopant concentrations as low as 10{sup 16} cm{sup -3} could be detected. More recent PEEM investigations of Schottky contacts were reported in the late 1990s by Giesen et al., followed by a series of papers in the early 2000s addressing doping contrast in PEEM by Ballarotto and co-workers and Frank and co-workers. In contrast to PEEM, comparatively little has been done to identify contrast mechanisms and assess the capabilities of LEEM for imaging semiconductor device strictures. The one exception is the work of Mankos et al., who evaluated the impact of high-throughput requirements on the LEEM designs and demonstrated new applications of imaging modes with a tilted electron beam. To assess its potential as a semiconductor device imaging tool and to identify contrast mechanisms, we used LEEM to investigate doped Si test structures. In section 2, Imaging Oxide-Covered Doped Si Structures Using LEEM, we show that the LEEM technique is able to provide reasonably high contrast images across lateral pn junctions. The observed contrast is attributed to a work function difference ({Delta}{phi}) between the p- and n-type regions. However, because the doped regions were buried under a thermal oxide ({approx}3.5 nm thick), e-beam charging during imaging prevented quantitative measurements of {Delta}{phi}. As part of this project, we also investigated a series of similar test structures in which the thermal oxide was removed by a chemical etch. With the oxide removed, we obtained intensity-versus-voltage (I-V) curves through the transition from mirror to LEEM mode and determined the relative positions of the vacuum cutoffs for the differently doped regions. Although the details are not discussed in this report, the relative position in voltage of the vacuum cutoffs are a direct measure of the work function difference ({Delta}{phi}) between the p- and n-doped regions.

36 MATERIALS SCIENCE↗