Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sensitivity and Specificity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Measurement of cross sections for mesonless charged-current muon neutrino interactions on argon with and without protons at MicroBooNE

urrent and upcoming neutrino experiments at Fermilab will rely on liquid argon time projection chambers (LArTPCs) as the primary detector technology. To reach the ambitious precision required for their physics goals, a detailed understanding of neutrino-argon scattering must be achieved. For the present Short-Baseline Neutrino program, the dominant reaction channel is charged-current muon neutrino interactions leading to mesonless final states with and without protons. Using a large data set of neutrino interactions recorded by the MicroBooNE LArTPC detector at Fermilab, we report progress towards new measurements of differential cross sections in this channel. The analysis leverages multiple event reconstruction paradigms and observables specifically chosen to maximize sensitivity to nuclear effects of interest for improving neutrino scattering models. Related previous cross-section results from MicroBooNE and a preview of what to expect from the new analysis will both be featured in this presentation.

Liu, Liang [Fermilab]↗

Laser Doppler velocimeter investigation of trailing vortices behind a semi-span swept wing in a landing configuration

Measured axial and tangential velocity profiles in the near wake vortices of a semi-span model of the Convair 990 wing in the NASA-Ames 7- by 10-foot wind tunnel are presented. A scanning laser Doppler velocimeter was used to obtain data at two different downstream stations (0.49 and 1.25 wing spans) at various angles of attack and configurations from wing alone to wing plus nacelles, anti-shock bodies, and flaps deflected 27 deg (landing configuration). It is shown that the velocity distributions within the wake are quite sensitive to span loading. Specifically, it is illustrated that an aircraft flying at given lift coefficient (C SUB L), can substantially reduce its trailing vortex upset potential by deploying its flaps and altering its flight attitude to maintain the same C SUB L. This might be taken into consideration along with performance and noise considerations in the selection of aircraft approach lift over drag.

Ciffone, D. L.↗

An improved method for echographic detection of left atrial enlargement

Echographic dimensions of the aortic root and left atrium were compared in 170 patients in order to assess dilation of the left atrium with reference to the relatively nondistensible fibrous aortic root. In 50 patients without cause for left atrial or aortic enlargement, the ratio of left atrial/aortic root dimensions was 0.87 to 1.11. In 80 patients with known cause for left atrial enlargement, the left atrial/aortic root ratio was greater than or equal to 1.17. In 40 patients with isolated valve disease, dilation of both the aortic root and the left atrium resulted in a left atrial/aortic root dimension ratio less than 1.17 in some patients. Despite this consideration, the comparison of left atrial and aortic root dimension appears to be as specific as, and more sensitive than, previously proposed methods for the evaluation of left atrial enlargement.

Brown, O. R.↗

Thermal IR imaging system using a self-scanned HgCdTe/CCD detector array

It is likely that future high resolution earth observation imaging systems will utilize self-scanned IR detectors. In an initial step toward this goal, an IR imaging system operating in the 10 to 12 micron spectral region has been developed. This system uses a 9-element HgCdTe/CCD linear array operating in the photoconductive mode, nine pre-amplifiers and a silicon CCD multiplexer integrated into a focal plane assembly. Opto-mechanical techniques are used to scan the scene and images are produced in real time. The imaging performance of this system is described and measurements of noise, responsivity, specific detectivity, and detector sensitivity profiles are presented. The requirements for more advanced detector arrays for use in future NASA remote sensing missions are also discussed.

Husain-Abidi, A. S.↗

The Space Telescope

The Space Telescope, still under construction, is discussed in light of the constraints imposed on ground-based telescopes. The history of the Space Telescope is traced from its conceptual origin to its actual construction, and design considerations used to determine the Space Telescope construction are described. The optical system of the telescope will have an aperture of 2.4 m, a focal ratio of 24, and a front of primary to focus of 1.5 m. The fine guidance system will use astigmatic images at the edge of the field of view to provide the guidance signal for maintaining stability to 0.007 arcseconds. The guidestars are required for 85% of random fields located at the galactic poles, and the system sensitivity must meet performance specifications for stars brighter than 13.5 magnitude. The scientific instruments - the wide field camera, the faint object camera, the faint object spectrograph, the high resolution spectrograph, the high speed photometer, and the fine guidance sensors - are discussed in detail. Finally, the operations system, including schedule contraints and the Science Institute, is presented.

Odell, C. R.↗

Economic impact of fuel properties on turbine powered business aircraft

The principal objective was to estimate the economic impact on the turbine-powered business aviation fleet of potential changes in the composition and properties of aviation fuel. Secondary objectives include estimation of the sensitivity of costs to specific fuel properties, and an assessment of the directions in which further research should be directed. The study was based on the published characteristics of typical and specific modern aircraft in three classes; heavy jet, light jet, and turboprop. Missions of these aircraft were simulated by computer methods for each aircraft for several range and payload combinations, and assumed atmospheric temperatures ranging from nominal to extremely cold. Five fuels were selected for comparison with the reference fuel, nominal Jet A. An overview of the data, the mathematic models, the data reduction and analysis procedure, and the results of the study are given. The direct operating costs of the study fuels are compared with that of the reference fuel in the 1990 time-frame, and the anticipated fleet costs and fuel break-even costs are estimated.

Powell, F. D.↗

Human factors and productivity on Space Station Freedom

Three main facets of man systems are investigated with reference to the Space Station Freedom program: specific hardware systems that focus on the human element; requirements definition for man-systems integration; and crew interface and operations analysis. Three key criteria have been identified for selecting individuals to constitute the human system or crew for Space Station Freedom missions: aptitude for mission specific skills, motivation, and sensitivity to self and others. Integration of the human system into the complex engineering and science systems planned on Space Station Freedom will require the close collaboration of engineers, physicians, psychologists, and human factors experts. Ground-based research and experiments on the KC-135 aircraft are providing information about how human systems will function on a space station and how to design other systems to interact with the crew. A laboratory for further research will be provided onboard Space Station Freedom.

Leach, C. S.↗

Photovoltaic power for a lunar base

A lunar base is an attractive option for space exploration plans early in the next century. The primary options for a lunar base power system are solar and nuclear. This paper details the requirements for a photovoltaic powered lunar base. Topics covered are (1) requirements for power during the lunar day and during the night, (2) solar cells, present and future availability, efficiency, specific power, and temperature sensitivity, (3) storage options for the lunar night, (4) arrays and system integration, and (5) the potential for production of photovoltaic arrays and storage capability from locally available materials.

Landis, Geoffrey A.↗

Diode injection - seeded, 940 nanometer (nm), titanium - sapphire laser for H2O DIAL (differential absorption lidar), measurements

Differential absorption of laser radiation by various molecular species represents both a selective and a sensitive method of measuring specific atmospheric constituents. DIAL measurements can be carried out via two different means. Both involve using two laser pulses with slightly different wavelengths (lambda), (one lambda at a strong absorption line of the molecule of interest, the other detuned into the wing of the line), and comparing the attenuation of the pulses. One approach relies on scattering of the radiation from some conveniently located topographical target. In the other technique elastic scattering from atmospheric aerosols and particulates is used to return the radiation to the lidar receiver system. This case is referred to as the differential absorption and scattering technique, and is the technique we are interested in to measure water vapor at 940 nm. The 940 nm wavelength is extremely desirable to atmospheric scientist interested in accurate DIAL measurements of H2O in the upper and lower troposphere. Simulated measurements using approximately 940 nm and 815 nm lasers at a range of altitudes and experimental conditions are shown. By offering access to larger absorption cross-sections, injected seeded, 940 nm DIAL laser transmitters would allow for more accurate water profile measurements at altitudes from 6 to 16 km than is currently possible with 730 nm and 815 nm DIAL laser transmitters. We have demonstrated the operation of an injected seeded titanium-sapphire (TS) laser operating at approximately 940 nm with an energy of more than 90 mJ per pulse. The TS laser is pumped by a commercial, 600 mJ, 532 nm, 10 Hz Nd:YAG laser. The slope efficiency of the laser using a flat 50 percent R output coupler and a 10 m end-mirror is shown. The laser was injected seeded with a CW, AlGaAs, semiconductor diode laser which had an output of 83 mW. The CW diode seed beam was introduced into the TS laser cavity through a HR end-mirror. When the diode beam is aligned to the TS resonator, it controls the TS laser output wavelength and its spectral line width with the required resolution for DIAL applications. This work supports the need for the development of 940 nm, titanium-sapphire DIAL transmitters.

Miller, George E.↗

ISS-Crystal Growth of Photorefractive Materials (BSO): Critical Design Issues for Optimized Data Extraction from Space Experiments

Realization of the full potential of photorefractive materials in device technology is seriously impeded by our inability to achieve controlled formation of critical defects during single crystal growth and by difficulties in meeting the required degree of compositional uniformity on a micro-scale over macroscopic dimensions. The exact nature and origin of the critical defects which control photorefractivity could not as yet be identified because of gravitational interference. There exists, however, strong evidence that the density of defect formation and their spatial distribution are adversely affected by gravitational interference which precludes the establishment of quantifiable and controllable heat and mass transfer conditions during crystal growth. The current, NASA sponsored research at MIT is directed at establishing a basis for the development of a comprehensive approach to the optimization of property control during melt growth of photorefractive materials, making use of the m-g environment, provided in the International Space Station. The objectives to be pursued in m-g research on photorefractive BSO (Bi12SiO20) are: (a) identification of the x-level(s) responsible for photorefractivity in undoped BSO; (b) development of approaches leading to the control of x-level formation at uniform spatial distribution; (c) development of doping and processing procedures for optimization of the critical, application specific parameters, spectral response, sensitivity, response time and matrix stability. The presentation will focus on: the rationale for the justification of the space experiment, ground-based development efforts, design considerations for the space experiments, strategic plan of the space experiments, and approaches to the quantitative analysis of the space experiments.

Hyers, Robert W.↗

Risk reduction using DDP (Defect Detection and Prevention): Software support and software applications

Risk assessment and mitigation is the focus of the Defect Detection and Prevention (DDP) process, which has been applied to spacecraft technology assessments and planning, both hardware and software. DDP's major elements and their relevance to core requirement engineering concerns are summarized. The accompanying research demonstration illustrates DDP's tool support, and further customizations for application to software.

Software-specific customizations↗

Model-based parameter estimation using cardiovascular response to orthostatic stress

This paper presents a cardiovascular model that is capable of simulating the short-term (< or approximately equal to 3 min) transient hemodynamic response to gravitational stress and a gradient-based optimization method that allows for the automated estimation of model parameters from simulated or experimental data. We perform a sensitivity analysis of the transient heart rate response to determine which parameters of the model impact the heart rate dynamics significantly. We subsequently include only those parameters in the estimation routine that impact the transient heart rate dynamics substantially. We apply the estimation algorithm to both simulated and real data and showed that restriction to the 20 most important parameters does not impair our ability to match the data.

Non-NASA Center↗

Automated quantification of mitral valve regurgitation based on normalized centerline velocity distribution

Previous echocardiographic techniques for quantifying valvular regurgitation are limited by factors including uncertainties for orifice location and a hemispheric convergence assumption that often results in over- and underestimation of flow rate and regurgitant orifice area. Using computational fluid dynamics simulations, these factors were eliminated, allowing a more accurate assessment of regurgitation. A model was developed to allow automated quantification of regurgitant orifice diameter based on the centerline velocity data available from color M-mode echocardiography. The model, validated using in vitro unsteady flow data, demonstrated improved accuracy for orifice diameter (y=0.95x + 0.38, r=0.96) and volume (y=1.18x - 4.72, r=0.93).

NASA Program Biomedical Research and Countermeasur↗

Investigation of electrolyte measurement in diluted whole blood using spectroscopic and chemometric methods

The feasibility of using near-infrared (NIR) spectroscopy in combination with partial least-squares (PLS) regression was explored to measure electrolyte concentration in whole blood samples. Spectra were collected from diluted blood samples containing randomized, clinically relevant concentrations of Na+, K+, and Ca2+. Sodium was also studied in lysed blood. Reference measurements were made from the same samples using a standard clinical chemistry instrument. Partial least squares (PLS) was used to develop calibration models for each ion with acceptable results (Na+, R2 = 0.86, CVSEP = 9.5 mmol/L; K+, R2 = 0.54, CVSEP = 1.4 mmol/L; Ca2+, R2 = 0.56, CVSEP = 0.18 mmol/L). Slightly improved results were obtained using a narrower wavelength region (470-925 nm) where hemoglobin, but not water, absorbed indicating that ionic interaction with hemoglobin is as effective as water in causing measurable spectral variation. Good models were also achieved for sodium in lysed blood, illustrating that cell swelling, which is correlated with sodium concentration, is not required for calibration model development.

Non-NASA Center↗

Noninvasive, near infrared spectroscopic-measured muscle pH and PO2 indicate tissue perfusion for cardiac surgical patients undergoing cardiopulmonary bypass

OBJECTIVE: To determine whether near infrared spectroscopic measurement of tissue pH and Po2 has sufficient accuracy to assess variation in tissue perfusion resulting from changes in blood pressure and metabolic demand during cardiopulmonary bypass. DESIGN: Prospective clinical study. SETTING: Academic medical center. SUBJECTS: Eighteen elective cardiac surgical patients. INTERVENTION: Cardiac surgery under cardiopulmonary bypass. MEASUREMENTS AND MAIN RESULTS: A near infrared spectroscopic fiber optic probe was placed over the hypothenar eminence. Reference Po2 and pH sensors were inserted in the abductor digiti minimi (V). Data were collected every 30 secs during surgery and for 6 hrs following cardiopulmonary bypass. Calibration equations developed from one third of the data were used with the remaining data to investigate sensitivity of the near infrared spectroscopic measurement to physiologic changes resulting from cardiopulmonary bypass. Near infrared spectroscopic and reference pH and Po2 measurements were compared for each subject using standard error of prediction. Near infrared spectroscopic pH and Po2 at baseline were compared with values during cardiopulmonary bypass just before rewarming commenced (hypotensive, hypothermic), after rewarming (hypotensive, normothermic) just before discontinuation of cardiopulmonary bypass, and at 6 hrs following cardiopulmonary bypass (normotensive, normothermic) using mixed-model analysis of variance. Near infrared spectroscopic pH and Po2 were well correlated with the invasive measurement of pH (R2 =.84) and Po2 (R 2 =.66) with an average standard error of prediction of 0.022 +/- 0.008 pH units and 6 +/- 3 mm Hg, respectively. The average difference between the invasive and near infrared spectroscopic measurement was near zero for both the pH and Po2 measurements. Near infrared spectroscopic Po2 significantly decreased 50% on initiation of cardiopulmonary bypass and remained depressed throughout the bypass and monitored intensive care period. Near infrared spectroscopic pH decreased significantly during cardiopulmonary bypass, decreased significantly during rewarming, and remained depressed 6 hrs after cardiopulmonary bypass. Diabetic patients responded differently than nondiabetic subjects to cardiopulmonary bypass, with lower muscle pH values (p =.02). CONCLUSIONS: Near infrared spectroscopic-measured muscle pH and Po2 are sensitive to changes in tissue perfusion during cardiopulmonary bypass.

Non-NASA Center↗

Modeling of the HiPco process for carbon nanotube production. II. Reactor-scale analysis

The high-pressure carbon monoxide (HiPco) process, developed at Rice University, has been reported to produce single-walled carbon nanotubes from gas-phase reactions of iron carbonyl in carbon monoxide at high pressures (10-100 atm). Computational modeling is used here to develop an understanding of the HiPco process. A detailed kinetic model of the HiPco process that includes of the precursor, decomposition metal cluster formation and growth, and carbon nanotube growth was developed in the previous article (Part I). Decomposition of precursor molecules is necessary to initiate metal cluster formation. The metal clusters serve as catalysts for carbon nanotube growth. The diameter of metal clusters and number of atoms in these clusters are some of the essential information for predicting carbon nanotube formation and growth, which is then modeled by the Boudouard reaction with metal catalysts. Based on the detailed model simulations, a reduced kinetic model was also developed in Part I for use in reactor-scale flowfield calculations. Here this reduced kinetic model is integrated with a two-dimensional axisymmetric reactor flow model to predict reactor performance. Carbon nanotube growth is examined with respect to several process variables (peripheral jet temperature, reactor pressure, and Fe(CO)5 concentration) with the use of the axisymmetric model, and the computed results are compared with existing experimental data. The model yields most of the qualitative trends observed in the experiments and helps to understanding the fundamental processes in HiPco carbon nanotube production.

Validation Studies↗

Modeling of the HiPco process for carbon nanotube production. I. Chemical kinetics

A chemical kinetic model is developed to help understand and optimize the production of single-walled carbon nanotubes via the high-pressure carbon monoxide (HiPco) process, which employs iron pentacarbonyl as the catalyst precursor and carbon monoxide as the carbon feedstock. The model separates the HiPco process into three steps, precursor decomposition, catalyst growth and evaporation, and carbon nanotube production resulting from the catalyst-enhanced disproportionation of carbon monoxide, known as the Boudouard reaction: 2 CO(g)-->C(s) + CO2(g). The resulting detailed model contains 971 species and 1948 chemical reactions. A second model with a reduced reaction set containing 14 species and 22 chemical reactions is developed on the basis of the detailed model and reproduces the chemistry of the major species. Results showing the parametric dependence of temperature, total pressure, and initial precursor partial pressures are presented, with comparison between the two models. The reduced model is more amenable to coupled reacting flow-field simulations, presented in the following article.

Evaluation Studies↗

Focused Assessment with Sonography for Trauma in weightlessness: a feasibility study

BACKGROUND: The Focused Assessment with Sonography for Trauma (FAST) examines for fluid in gravitationally dependent regions. There is no prior experience with this technique in weightlessness, such as on the International Space Station, where sonography is currently the only diagnostic imaging tool. STUDY DESIGN: A ground-based (1 g) porcine model for sonography was developed. We examined both the feasibility and the comparative performance of the FAST examination in parabolic flight. Sonographic detection and fluid behavior were evaluated in four animals during alternating weightlessness (0 g) and hypergravity (1.8 g) periods. During flight, boluses of fluid were incrementally introduced into the peritoneal cavity. Standardized sonographic windows were recorded. Postflight, the video recordings were divided into 169 20-second segments for subsequent interpretation by 12 blinded ultrasonography experts. Reviewers first decided whether a video segment was of sufficient diagnostic quality to analyze (determinate). Determinate segments were then analyzed as containing or not containing fluid. A probit regression model compared the probability of a positive fluid diagnosis to actual fluid levels (0 to 500 mL) under both 0-g and 1.8-g conditions. RESULTS: The in-flight sonographers found real-time scanning and interpretation technically similar to that of terrestrial conditions, as long as restraint was maintained. On blinded review, 80% of the recorded ultrasound segments were considered determinate. The best sensitivity for diagnosis in 0 g was found to be from the subhepatic space, with probability of a positive fluid diagnosis ranging from 9% (no fluid) to 51% (500 mL fluid). CONCLUSIONS: The FAST examination is technically feasible in weightlessness, and merits operational consideration for clinical contingencies in space.

NASA Discipline Life Sciences Technologies↗