Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sensor Integration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Detection of saliva-range glucose concentrations using organic thin-film transistors

We describe the development of a glucose sensor through direct incorporation of an enzyme (glucose oxidase) into the gate of an organic thin film transistor (OTFT). We show that glucose diffusion is the key determinant of the device response time and present a mechanism of glucose sensing in these devices that involves protonic doping of the transistor channel via enzymatic oxidation of glucose. The integrated OTFT sensor is sensitive across 4 decades of glucose concentration; a range that encompasses both the blood and salivary glucose concentration levels. As such, this work acts as a proof-of-concept for low-cost printed biosensors for salivary glucose.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Micro-Structured Sapphire Fiber Sensors for Simultaneous Measurements of High-T and Dynamic Gas Pressure in Harsh Environments

This is the final report for the program “Micro-Structured Sapphire Fiber Sensors for Simultaneous Measurements of High Temperature and Dynamic Gas Pressure in Harsh Environments”, funded by NETL, and performed by Missouri University of Science and Technology, Clemson University and University of Cincinnati from October 1, 2009 to September 30, 2014. Securing a sustainable energy economy by developing affordable and clean energy from coal and other fossil fuels is a central element to the mission of The U.S. Department of Energy’s (DOE) National Energy Technology Laboratory (NETL). To further this mission, NETL funds research and development of novel sensor technologies that can function under the extreme operating conditions often found in advanced power systems. The main objective of this research program is to conduct fundamental and applied research that will lead to successful development and demonstration of robust, multiplexed, microstructured silica and single-crystal sapphire fiber sensors to be deployed into the hot zones of advanced power and fuel systems for simultaneous measurements of high temperature and gas pressure. The specific objectives of this research program include: 1) Design, fabrication and demonstration of multiplexed, robust silica and sapphire fiber temperature and dynamic gas pressure sensors that can survive and maintain fully operational in high-temperature harsh environments. 2) Development and demonstration of a novel method to demodulate the multiplexed interferograms for simultaneous measurements of temperature and gas pressure in harsh environments. 3) Development and demonstration of novel sapphire fiber cladding and low numerical aperture (NA) excitation techniques to assure high signal integrity and sensor robustness.

01 COAL, LIGNITE, AND PEAT↗

Glove-based sensors for multimodal monitoring of natural sweat

Sweat sensors targeting exercise or chemically induced sweat have shown promise for noninvasive health monitoring. Natural thermoregulatory sweat is an attractive alternative as it can be accessed during routine and sedentary activity without impeding user lifestyles and potentially preserves correlations between sweat and blood biomarkers. We present simple glove-based sensors to accumulate natural sweat with minimal evaporation, capitalizing on high sweat gland densities to collect hundreds of microliters in just 30 min without active sweat stimulation. Sensing electrodes are patterned on nitrile gloves and finger cots for in situ detection of diverse biomarkers, including electrolytes and xenobiotics, and multiple gloves or cots are worn in sequence to track overarching analyte dynamics. Direct integration of sensors into gloves represents a simple and low-overhead scheme for natural sweat analysis, enabling sweat-based physiological monitoring to become practical and routine without requiring highly complex or miniaturized components for analyte collection and signal transduction.

42 ENGINEERING↗

Development and Characterization of a Self-Tightening Tourniquet System

Uncontrolled hemorrhage remains a leading cause of death in both emergency and military medicine. Tourniquets are essential to stopping hemorrhage in these scenarios, but they suffer from subjective, inconsistent application. Here, we demonstrate how tourniquet application can be automated using sensors and computer algorithms. The auto-tourniquet self-tightens until blood pressure oscillations are no longer registered by the pressure sensor connected to the pneumatic pressure cuff. The auto-tourniquet’s performance in stopping the bleed was comparable to manual tourniquet application, but the time required to fully occlude the bleed was longer. Application of the tourniquet was significantly smoother, and less variable, for the automatic tourniquet compared to manual tourniquet application. This proof-of-concept study highlights how automated tourniquets can be integrated with sensors to provide a much more consistent application and use compared to manual application, even in controlled, low stress testing conditions. Future work will investigate different sensors and tourniquets to improve the application time and repeatability.

Vega, Saul J.↗

Fine-Grained Power and Energy Attribution on AMD GPU/APU-Based Exascale Nodes

Modern exascale GPU- and APU-based systems provide multiple power and energy sensors, but differences in scope, update rate, timing, and filtering complicate the attribution of short-lived accelerator activity. This paper presents a methodology to characterize and correct these effects on Cray EX systems with AMD Instinct MI250X GPUs (Frontier) and MI300A APUs (Portage). Using controlled square-wave workloads, we quantify update intervals, delay, aliasing, and variability across up to 512 GPUs and 480 APUs with on-chip (rocm-smi/amd-smi) and off-chip Cray Power Management sensors. We reconstruct power from cumulative energy counters to achieve faster response times, validate it against on-chip, off-chip, and node-level sensors, and integrate the resulting streams into a Score-P/PAPI-based tool for time-aligned, phase-level attribution. Applied to rocHPL, rocHPL-MxP, and HPG-MxP, the method separates energy savings due to reduced runtime from changes in power. Mixed precision reduces node energy on Frontier by 79% for rocHPL-MxP and 31% for HPG-MxP, with similar trends on Portage. These results provide portable guidance for sensor validation and power-aware optimization on current and future exascale systems.

Mcdaniel, Adam [ORNL] (ORCID:000000016926028X)↗

Development of thermal transit flow measurement for small modular reactors - 140

Safe, reliable, and efficient operation of nuclear reactors requires timely and accurate measurement of primary coolant parameters such as temperature, flow, pressure, and level. These measurements may be challenging in small modular reactors (SMRs) with integral vessel design. For SMRs with the integral design, sensors may be located in confined spaces or embedded within pressure vessels. The absence of primary coolant loops is another fundamental design attribute that will affect the location of sensors, sensor interfaces, and types of sensors suited for process parameter measurements. Further, the number and location of pressure vessel penetrations may be constrained compared to traditional nuclear power plants (NPPs). As a result, conventional NPP temperature, flow, pressure, and level sensors may not be appropriate for use in SMRs. This paper addresses the development of new sensor technology for hybrid temperature, flow, and level measurement. The authors demonstrate the alternative use of resistance temperature detectors (RTDs) where cross-correlation of process temperature variations between RTDs is used to calculate process flow velocity. The new sensor and measurement technology will also incorporate RTD response time and self-heating characteristics to provide flow and level measurement in accident conditions. This capability would simplify reactor design and enable optimal placement of reactor pressure vessel penetrations leading to increased operational reliability and safety. The cross-correlation of temperature signals and adaptation for flow measurement in a laboratory setting is presented here. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Natural Gas Fugitive Leak Detection Using an Unmanned Aerial Vehicle: Localization and Quantification of Emission Rate

We describe a set of methods for locating and quantifying natural gas leaks using a small unmanned aerial system equipped with a path-integrated methane sensor. The algorithms are developed as part of a system to enable the continuous monitoring of methane, supported by a series of over 200 methane release trials covering 51 release location and flow rate combinations. The system was found throughout the trials to reliably distinguish between cases with and without a methane release down to 2 standard cubic feet per hour (0.011 g/s). Among several methods evaluated for horizontal localization, the location corresponding to the maximum path-integrated methane reading performed best with a mean absolute error of 1.2 m if the results from several flights are spatially averaged. Additionally, a method of rotating the data around the estimated leak location according to the wind is developed, with the leak magnitude calculated from the average crosswind integrated flux in the region near the source location. The system is initially applied at the well pad scale (100–1000 m2 area). Validation of these methods is presented including tests with unknown leak locations. Sources of error, including GPS uncertainty, meteorological variables, data averaging, and flight pattern coverage, are discussed. The techniques described here are important for surveys of small facilities where the scales for dispersion-based approaches are not readily applicable.

47 OTHER INSTRUMENTATION↗

Development of a Cloud-based Application to Enable a Scalable Risk-informed Predictive Maintenance Strategy at Nuclear Power Plants

Light-water reactor operations and maintenance (O&M) costs are prohibitively high, thus contributing to the premature decommissioning of nuclear power plants (NPPs). This is partly due to how the equipment is monitored. In recent years, cloud computing has emerged as a dominant technology by virtue of its low costs, computing and storage adaptability, and ability to host applications over numerous types of virtual infrastructures. Cloud computing can be a cost-effective alternative to onsite storage and diagnostics. This paper conducts a techno-economic assessment of a provisional cloud deployment architecture for a NPP predictive monitoring (PdM) system. The cloud-based monitoring system would enable maintenance and diagnostics (M&D) analysts and other authorized plant users to remotely monitor equipment functionality so as to enable PdM practices and early detection of faults. The Microsoft Azure cloud platform is included in the proposed cloud architecture to provide data processing and storage, sensor device networking, and database management; however, this analysis could be extended to other cloud computing service providers as well. For the techno-economic assessment, technical feasibility is measured in terms of network performance metrics such as response time, latency, and throughput, whereas economic feasibility is measured in terms of operational costs and capital expenditures. Finally, this report covers certain regulatory and security aspects that may concern licensees looking to implement cloud computing. The report focuses on the integration of sensor database storage, the application of cloud resources to PdM, and the identification of technological and economic hurdles associated with moving to a cloud-computing-based architecture.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Direct ink write multi-material printing of PDMS-BTO composites with MWCNT electrodes for flexible force sensors

Here, with recent advances of additive manufacturing technology, direct ink write (DIW) printing has allowed to incorporate multi-material printing of various materials with freedom of design and complex geometric shapes to complete functional sensors in a one-step fabrication. This paper introduces the use of DIW 3D printing of polydimethylsiloxane (PDMS) with barium titanate (BTO) filler as stretchable composites with tunable piezoelectric properties that can be used for force sensors applications. To improve the bonding between stretchable piezoelectric composites and electrodes, multi-walled carbon nanotubes was included in the fabrication of electrodes at a fixed ratio of 11 wt. %. The alignment of the BTO dipoles was achieved through corona poling method, which applies an electric charge on the surface layer of the functional material, aligning the dipoles in the desired direction and thus gaining the piezoelectricity. Different BTO mixing ratios (10–50 wt. %) were evaluated in order to obtain tunable piezoelectric properties and compare the sensitivity with respect their elastic properties. Tensile testing and piezoelectric testing were carried out to characterize mechanical and piezoelectric properties. Results showed that fabricated PDMS with 50 wt. % BTO gave the highest piezoelectric coefficient (d 33 ) of 11.5 pC N -1 and with an output voltage of 385 mV under compression loading of >200 lbF. This demonstrates feasibility of using multi-material DIW printing to fabricate piezoelectric force sensors with integrated electrodes in one-step without compromising the flexibility of the material.

36 MATERIALS SCIENCE↗

System Calibration Including Time Delay Estimation for GNSS/INS-Assisted Pushbroom Scanners Onboard UAV Platforms

Unmanned aerial vehicles (UAVs ) equipped with imaging sensors and integrated global navigation satellite system/inertial navigation system (GNSS/INS ) units are used for numerous applications. Deriving reliable 3D coordinates from such UAVs is contingent on accurate geometric calibration, which encompasses the estimation of mounting parameters and synchronization errors. Through a rigorous impact analysis of such systematic errors, this article proposes a direct approach for spatial and temporal calibration (estimating system parameters through a bundle adjustment procedure) of a GNSS/INS -assisted pushbroom scanner onboard a UAV platform. The calibration results show that the horizontal and vertical accuracies are within the ground sampling distance of the sensor. Unlike for frame camera systems, this article also shows that the indirect approach is not a feasible solution for pushbroom scanners due to their limited ability for decoupling system parameters. This finding provides further support that the direct approach is recommended for spatial and temporal calibration of UAV pushbroom scanner systems.

47 OTHER INSTRUMENTATION↗

Evaluation of a catalytically aided thermal regeneration method for quartz filter-based black carbon sensing

Black carbon (BC)–a strong indicator of diesel particulate matter and other sources of incomplete carbonaceous fuel combustion–is an important air pollutant that affects public health, yet low-cost sensors capable of long-term, autonomous BC monitoring remain underdeveloped. We report on the development and evaluation of a novel BC prototype sensor that integrates soot collection on a quartz filter, in-situ optical transmission measurement, and thermal filter regeneration. To enable regeneration at lower temperatures, we evaluated the catalytic effects of various alkali metal salts pre-applied to the filter. Among these, cesium carbonate (Cs 2 CO 3 ) exhibited the strongest catalytic activity, lowering the temperature required for complete BC removal by up to 190 °C and reducing energy consumption by more than 75% compared to that required for untreated filters. The catalytic effect persisted through 10 BC collection–regeneration cycles. These findings demonstrate the potential of catalytically aided thermal regeneration in BC sensors and suggest a pathway toward energy-efficient and reduced maintenance air quality monitoring suitable for distributed BC monitoring networks.

Tang, Xiaochen [Lawrence Berkeley National Laborat↗

Analysis of ultra-high sensitivity configuration in chip-integrated photonic crystal microcavity bio-sensors

We analyze the contributions of quality factor, fill fraction, and group index of chip-integrated resonance microcavity devices, to the detection limit for bulk chemical sensing and the minimum detectable biomolecule concentration in biosensing. We analyze the contributions from analyte absorbance, as well as from temperature and spectral noise. Slow light in two-dimensional photonic crystals provide opportunities for significant reduction of the detection limit below 1 × 10{sup −7} RIU (refractive index unit) which can enable highly sensitive sensors in diverse application areas. We demonstrate experimentally detected concentration of 1 fM (67 fg/ml) for the binding between biotin and avidin, the lowest reported till date.

36 MATERIALS SCIENCE↗

Real-Time Ozone Detection Based on a Microfabricated Quartz Crystal Tuning Fork Sensor

A chemical sensor for ozone based on an array of microfabricated tuning forks is described. The tuning forks are highly sensitive and stable, with low power consumption and cost. The selective detection is based on the specific reaction of the polymer with ozone. With a mass detection limit of ~2 pg/mm 2 and response time of 1 second, the sensor coated with a polymer sensing material can detect ppb-level ozone in air. The sensor is integrated into a miniaturized wearable device containing a detection circuit, filtration, battery and wireless communication chip, which is ideal for personal and microenvironmental chemical exposure monitoring.

sensitive↗

Investigating the malleability of RNA aptamers

Aptamers are short, single-stranded nucleic acids with structures that frequently change upon ligand binding and are sensitive to the ionic environment. To achieve facile application of aptamers in controlling cellular activities, a better understanding is needed of aptamer ligand binding parameters, structures, intramolecular mobilities and how these structures adapt to different ionic environments with consequent effects on their ligand binding characteristics.The paper discusses the integration of biochemical analysis with NMR spectroscopy and computational modeling to explore the relation between ligand binding and structural malleability of some well-studied aptamers. Several methods for determining aptamer binding affinity and specificity are discussed, including isothermal titration calorimetry, steady state fluorescence of 2-aminopurine substituted aptamers, and dye displacement assays. Also considered are aspects of molecular dynamics simulations specific to aptamers including adding ions and simulating aptamer structure in the absence of ligand when NMR spectroscopy or X-ray crystallography structures of the unoccupied aptamer are not available. We focus specifically on RNA aptamers that bind small molecule ligands as would be applied in sensors or integrated into riboswitches such as to measure the products of metabolic activity.

Affinity measurement↗

Application of an automated wireless structural monitoring system for long-span suspension bridges

This paper describes an automated wireless structural monitoring system installed at the New Carquinez Bridge (NCB). The designed system utilizes a dense network of wireless sensors installed in the bridge but remotely controlled by a hierarchically designed cyber-environment. The early efforts have included performance verification of a dense network of wireless sensors installed on the bridge and the establishment of a cellular gateway to the system for remote access from the internet. Acceleration of the main bridge span was the primary focus of the initial field deployment of the wireless monitoring system. An additional focus of the study is on ensuring wireless sensors can survive for long periods without human intervention. Toward this end, the life-expectancy of the wireless sensors has been enhanced by embedding efficient power management schemes in the sensors while integrating solar panels for power harvesting. The dynamic characteristics of the NCB under daily traffic and wind loads were extracted from the vibration response of the bridge deck and towers. These results have been compared to a high-fidelity finite element model of the bridge.

42 ENGINEERING↗

Nucleation and Growth of Blue Phase 3D Cubic Structure Under Continuously Changing Curved Boundary Conditions

The blue phase of liquid crystals (BPLCs) with a cubic lattice of disclination lines and 3D nanostructure enables the modulation of photonic bandgap thus casting them in the category of photonic crystals. Its unique nature promises applications in display technologies, electro‐optics, and sensors. To integrate these ordered materials into wearable devices a fundamental understanding of curvature, and spatial confinement is necessary. Although continuous confinement in flat geometries have been studied, confining curvature has shown to induce strong destabilization effects on the cubic structure and formation of topological defects, thereby deteriorating their optical performance. Moreover, limitations in controlling the curvature of droplets further hinder studies of nucleation and growth of BPLCs. Here, to address these challenges, micro‐scale patterned surfaces of concentric cylinders are exploited to systematically control curvatures. The impact of curvature on the confined BPLCs is revealed in terms of phase transition temperature, nucleation and growth, morphology, as well as phase transformation. This research offers valuable insights into the stability, and structural characteristics of BPLCs in adaptive photonic devices, paving the way for future advancements in flexible displays, sensors, and other technologies leveraging liquid crystal (LC) materials.

3D Cubic Structure↗

Label Free Detection of L-Glutamate Using Microfluidic Based Thermal Biosensor

A thermoelectric biosensor for the detection of L-glutamate concentration was developed. The thermoelectric sensor is integrated into a micro-calorimeter which measures the heat produced by biochemical reactions. The device contains a single flow channel that is 120 µm high and 10 mm wide with two fluid inlets and one fluid outlet. An antimony-bismuth (Sb-Bi) thermopile with high common mode rejection ratio is attached to the lower channel wall and measures the dynamic changes in the temperature when L-glutamate undergoes oxidative deamination in the presence of glutamate oxidase (GLOD). The thermopile has a Seebeck coefficient of ~7 µV·(m·K)-1 . The device geometry, together with hydrodynamic focusing, eliminates the need of extensive temperature control. Layer-by-layer assembly is used to immobilize GLOD on the surface of glass coverslips by alternate electrostatic adsorption of polyelectrolyte and GLOD. The impulse injection mode using a 6-port injection valve minimizes sample volume to 5 µL. The sensitivity of the sensor for glutamate is 17.9 nVs·mM-1 in the linear range of 0–54 mM with an R2 value of 0.9873. The lowest detection limit of the sensor for glutamate is 5.3 mM.

layer-by-layer self-assembly↗