Search NASA⌕ Search

SEARCH · Search NASA

Results for “Shorting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Variables controlling fatigue crack growth of short cracks

A study was conducted to evaluate the roles of crack closure and microstructure in the fatigue growth of short cracks. Testing was performed at R ratios of 0.1, 0.5, and 0.7. At all R ratios short cracks exhibited accelerated growth rates in comparison to long cracks. It was concluded that crack closure could not entirely account for the accelerated growth rates of short cracks. The accelerated growth rates occurred over crack lengths on the order of grain size, suggesting a strong influence of microstructure. A significant effect of grain boundaries and inclusions on short crack FCG behavior was observed. For very short crack lengths, fatigue growth rates do not appear to be a function of either delta K or R ratio.

Telesman, J.↗

Voyager Uranus encounter 0.2lbf T/VA short pulse test report

The attitude control thrusters on the Voyager spacecraft were tested for operation at electrical pulse widths of less than the current 10-millisecond minimum to reduce impulse bit and, therefore, reduce image smear of pictures taken during the Uranus encounter. Thrusters with the identical configuration of the units on the spacecraft were fired in an altitude chamber to characterize impulse bit and impulse bit variations as a function of electrical pulse widths and to determine if the short pulses decreased thruster life. Pulse widths of 4.0 milliseconds provide approximately 45 percent of the impulse provided by a 10-ms pulse, and thruster-to-thruster and pulse-to-pulse variation is approximately plus or minus 10 percent. Pulse widths shorter than 4 ms showed wide variation, and no pulse was obtained at 3 ms. Three thrusters were each subjected to 75,000 short pulses of 4 ms or less without performance degradation. A fourth thruster exhibited partial flow blockage after 13,000 short pulses, but this was attributed to prevous test history and not short pulse exposure. The Voyager attitude control thrusters should be considered flight qualified for short pulse operation at pulse widths of 4.0 ms or more.

Source record↗

Short time Fourier analysis of the electromyogram - Fast movements and constant contraction

Short-time Fourier analysis was applied to surface electromyograms (EMG) recorded during rapid movements, and during isometric contractions at constant forces. A portion of the data to be transformed by multiplying the signal by a Hamming window was selected, and then the discrete Fourier transform was computed. Shifting the window along the data record, a new spectrum was computed each 10 ms. The transformed data were displayed in spectograms or 'voiceprints'. This short-time technique made it possible to see time-dependencies in the EMG that are normally averaged in the Fourier analysis of these signals. Spectra of EMGs during isometric contractions at constant force vary in the short (10-20 ms) term. Short-time spectra from EMGs recorded during rapid movements were much less variable. The windowing technique picked out the typical 'three-burst pattern' in EMG's from both wrist and head movements. Spectra during the bursts were more consistent than those during isometric contractions. Furthermore, there was a consistent shift in spectral statistics in the course of the three bursts. Both the center frequency and the variance of the spectral energy distribution grew from the first burst to the second burst in the same muscle. The analogy between EMGs and speech signals is extended to argue for future applicability of short-time spectral analysis of EMG.

Hannaford, Blake↗

Short fatigue cracks in notched aluminum specimens

The short-crack fatigue behavior in notched specimens of Al 2024-T3 was studied at values of the stress ratio, R, equal to 0.5, 0.0, -1.0, and -2.0. Crack growth was monitored using a replica technique for cracks ranging in length from a few tens of a micron to the specimen's thickness (2.3 mm). Crack opening displacement was measured for surface cracks as short as 0.035 mm using the interferometric strain/displacement gage, a laser-based optical technique described by Sharpe (1982). It was found that the growth rates of short cracks were faster than the rates of long cracks for R values of -1.0 and -2.0. No significant difference was observed for R = 0.0, and at R = 0.5, the short cracks actually grew more slowly that the long ones. At all R values, the closure stresses measured for short cracks were smaller than those predicted for large cracks.

Lee, J. J.↗

Short-crack growth behaviour in various aircraft materials

The results of the first phase of an AGARD Cooperative Test Program on the behavior and growth of short fatigue cracks are reviewed. The establishment of a common test method, means of data collection/analysis and crack growth modeling in an aircraft alloy AA 2024-T3 are described. The second phase allowed testing of various materials and loading conditions. The results of this second phase are described. All materials exhibited a short-crack effect to some extent. The effect was much less evident in 4340 steel than in the other materials. For the aluminum, aluminum-lithium, and titanium alloys, short cracks grew at stress-intensity factor ranges lower, in some cases much lower, than the thresholds obtained from long crack tests. Several laboratories used the same crack growth model to analyze the growth of short cracks. Reasonable agreement was found between measured and predicted short-crack growth rates and fatigue lives.

Edwards, P. R.↗

Analytical and experimental studies of a short compact subsonic diffuser for a two-dimensional supersonic inlet

An experimental study of a two-dimensional supersonic inlet with a short compact subsonic diffuser, length to exit diameter (dl/d) ratio of 1.25, was conducted to investigate the impact of the short diffuser on inlet performance at low speeds and to assess the diffuser subsonic performance for a simulated diffuser flow corresponding to high-speed inlet conditions near the design flight Mach number of 2.2. For the low-speed testing, a drooped lip was employed to improve the inlet performance at a high angle of attack. For the simulated high-speed testing, air was blown through slots or discrete nozzles as an active boundary-layer control. The results from the low-speed performance test were compared with the results from a previous test program on the same inlet with a long subsonic diffuser (dl/d = 4.5). The comparison indicates that inlet recovery was not affected by the use of the short diffuser for either the baseline (no droop) or the drooped cowl lip configuration. However, the inlet baseline distortion for the short diffuser configuration was substantially higher than for the long diffuser. A comparison of the two configurations with a 70 deg drooped lip showed no significant difference in distortion. For the portion of the experimental program in which diffuser conditions for high-speed flight were simulated, diffuser-induced flow separation occurred. This separation was predicted from an analytical study that used the Hess potential flow panel method and the Herring two-dimensional boundary-layer analysis computer codes. The flow separated mainly on the diffuser ramp. Subsequent tests in which boundary-control systems were utilized showed that blowing with either slots or discrete nozzles could suppress the flow separation in the short subsonic diffuser, thereby substantially improving the diffuser performance.

Iek, Chanthy↗

The Long and the Short of Gamma-Ray Bursts

We report evidence from the Third BATSE Gamma-Ray Burst Catalog that long (T(sub 90) greater than 10 s) and short (T(sub 90) less than 10 s) gamma-ray bursts (GRBS) represent distinct source populations. Their spatial distributions are significantly different, with long bursts having = 0.282+/- 0.014 but short bursts having = 0.385 +/- 0.019, differing by 0.103 +/- 0.024, significant at the 4.3 or level. This implies different spatial origin and physical processes for long and short bursts. Long bursts may be explained by accretion-induced collapse. Short bursts require another mechanism, for which we suggest neutron star collisions. These are capable of producing neutrino bursts as short as a few milliseconds, consistent with the shortest observed timescales in GRBS. We briefly investigate the parameters of clusters in which neutron star collisions may occur, and discuss the nuclear evolution of expelled and accelerated matter.

Katz, J. I.↗

Subendocardial motion in hypertrophic cardiomyopathy: assessment from long- and short-axis views by pulsed tissue Doppler imaging

BACKGROUND: Tissue Doppler imaging (TDI) is a recently developed technique that allows the instantaneous measurement of intrinsic regional myocardial motion velocity. Pulsed TDI is capable of separately assessing left ventricular (LV) regional motion velocity caused by circumferential and longitudinal fiber contraction. This particular feature of function is still controversial in patients with hypertrophic cardiomyopathy (HC). METHODS: To better characterize intrinsic circumferential and longitudinal LV systolic myocardial function in HC, we used pulsed TDI to measure short- and long-axis LV motion velocities, respectively. The subendocardial motion velocity patterns at the middle of the LV posterior wall (PW) and ventricular septum (IVS) in LV parasternal and apical long-axis views were recorded by pulsed TDI in 19 patients with nonobstructive HC and in 21 normal controls (NC). RESULTS: Peak short- and long-axis systolic subendocardial velocities in both the LV PW and IVS were significantly smaller in the HC group than in the NC group, and the time to peak velocity was significantly delayed. Furthermore, peak PW systolic velocity was significantly greater along the long axis than along the short axis in the NC group (8.8 +/- 1.5 cm/s vs 8.2 +/- 1.4 cm/s, P <.05), whereas the opposite was observed in the HC group (6.1 +/- 1.2 cm/s vs 7.5 +/- 1.0 cm/s, P <.0001). No significant differences were found in either group between the long- and short-axis IVS velocities (HC: 5.9 +/- 1.4 cm/s vs 5.5 +/- 1.3 cm/s; NC: 7.8 +/- 1.3 cm/s vs 7.9 +/- 1.6 cm/s). CONCLUSIONS: By using the capability of pulsed TDI for the evaluation of intrinsic myocardial velocity instantaneously in a specific region and direction, we found impairment of LV myocardial systolic function in patients with HC not only in the hypertrophied IVS but also in the nonhypertrophied LV PW. We also found a greater decrease in LV PW velocities along the long axis than the short axis, suggesting greater impairment of long-axis contraction in patients with HC. Because our HC patients did not appear to have excessive intracavitary pressure, these results suggest that the relatively normal-appearing PW is directly affected by the HC pathologic process.

NASA Program Biomedical Research and Countermeasur↗

Short Gamma-Ray Bursts with Extended Emission

The recent association of several short gamma-ray bursts (GRBs) with early type galaxies with low star formation rate demonstrates that short bursts arise from a different progenitor mechanism than long bursts. However, since the duration distributions of the two classes overlap, membership is not always easily established. The picture is complicated by the occasional presence of softer, extended emission lasting tens of seconds after the initial spike- like emission comprising an otherwise short burst. Using the large BATSE sample with time-tagged event (TTE) data, we show that the fundamental defining characteristic of the short burst class is that the initial spike exhibits negligible spectral evolution at energies above approx. 25 keV. This is behavior is nearly ubiquitous for the 260 bursts with T(sub 90) less than 2s where the BATSE TTE data type completely included the initial spike: Their spectral lags measured between the 25-50 keV and 100-300 energy ranges are consistent with zero in 90-95% of the cases, with most outliers probably representing the tail of the long burst class. We also analyze a small sample of "short" BATSE bursts - those with the most fluent, intense extended emission. The same lack of evolution on the pulse timescale obtains for the extended emission in the brighter bursts where significant measurements can be made. One possible inference is that both emission components may arise in the same region. We also show that the dynamic range in the ratio of peak intensities, spike : extended, is at least approx. l0(exp 3), and that for some bursts, the extended emission is only a factor of 2-5 lower. However, for our whole sample the total counts fluence of the extended component equals or exceeds that in the spike by a factor of several.

Norris, J. P.↗

Lithium-Ion Small Cell Battery Shorting Study

Positive Temperature Coefficient (PTC) provides adequate sustained hard short protection for AEA batteries with up to 8 cells in series. PTC cannot protect against sustained hard short in AEA batteries with 10 cells or more in series. Protective fused connector is a proven way to protect larger batteries from hard short damage: a) Hard short not credible in unmanned missions; b) However, recommended during ground handling; c) Inexpensive item. Preliminary diode protection scheme has passed manned space safety requirements for high voltage batteries. SCM confirmed fused connector did not affect battery health, however, this affect of hard short on the its long calendar and cycle life performance needs to be verified.

Pearson, Chris↗

An Investigation of the Electrical Short Circuit Characteristics of Tin Whiskers

Existing risk simulations make the assumption that when a free tin whisker has bridged two adjacent exposed electrical conductors, the result is an electrical short circuit. This conservative assumption is made because shorting is a random event that has a currently unknown probability associated with it. Due to contact resistance electrical shorts may not occur at lower voltage levels. In this experiment, we study the effect of varying voltage on the breakdown of the contact resistance which leads to a short circuit. From this data we can estimate the probability of an electrical short, as a function of voltage, given that a free tin whisker has bridged two adjacent exposed electrical conductors. Also, three tin whiskers grown from the same Space Shuttle Orbiter card guide used in the aforementioned experiment were cross-sectioned and studied using a focused ion beam (FIB). The rare polycrystalline structure seen in the FIB cross section was confirmed using transmission electron microscopy (TEM). The FIB was also used to cross section two card guides to facilitate the measurement of the grain size to determine that the tin plating on the card guides had a bright finish.

Courey, Karim J.↗

Heterogeneity in Short Gamma-Ray Bursts

We analyze the Swift/BAT sample of short gamma-ray bursts, using an objective Bayesian Block procedure to extract temporal descriptors of the bursts' initial pulse complexes (IPCs). The sample comprises 12 and 41 bursts with and without extended emission (EE) components, respectively. IPCs of non-EE bursts are dominated by single pulse structures, while EE bursts tend to have two or more pulse structures. The medians of characteristic timescales - durations, pulse structure widths, and peak intervals - for EE bursts are factors of approx 2-3 longer than for non-EE bursts. A trend previously reported by Hakkila and colleagues unifying long and short bursts - the anti-correlation of pulse intensity and width - continues in the two short burst groups, with non-EE bursts extending to more intense, narrower pulses. In addition we find that preceding and succeeding pulse intensities are anti-correlated with pulse interval. We also examine the short burst X-ray afterglows as observed by the Swift/XRT. The median flux of the initial XRT detections for EE bursts (approx 6 X 10(exp -10) erg / sq cm/ s) is approx > 20 x brighter than for non-EE bursts, and the median X-ray afterglow duration for EE bursts (approx 60,000 s) is approx 30 x longer than for non-EE bursts. The tendency for EE bursts toward longer prompt-emission timescales and higher initial X-ray afterglow fluxes implies larger energy injections powering the afterglows. The longer-lasting X-ray afterglows of EE bursts may suggest that a significant fraction explode into more dense environments than non-EE bursts, or that the sometimes-dominant EE component efficiently p()wers the afterglow. Combined, these results favor different progenitors for EE and non-EE short bursts.

Norris, Jay P.↗

An Empirical Model for Estimating the Probability of Electrical Short Circuits from Tin Whiskers-Part I

Existing risk simulations make the assumption that when a free tin whisker has bridged two adjacent exposed electrical conductors, the result is an electrical short circuit. This conservative assumption is made because shorting is a random event that has a currently unknown probability associated with it. Due to contact resistance, electrical shorts may not occur at lower voltage levels. In this experiment, we study the effect of varying voltage on the breakdown of the contact resistance which leads to a short circuit. From this data, we can estimate the probability of an electrical short, as a function of voltage, given that a free tin whisker has bridged two adjacent exposed electrical conductors. In addition, three tin whiskers grown from the same Space Shuttle Orbiter card guide used in the aforementioned experiment were cross sectioned and studied using a focused ion beam (FIB).

Courey, Karim↗

An Investigation of the Electrical Short Circuit Characteristics of Tin Whiskers

Existing risk simulations make the assumption that when a free tin whisker has bridged two adjacent exposed electrical conductors, the result is an electrical short circuit. This conservative assumption is made because shorting is a random event that has a currently unknown probability associated with it. Due to contact resistance electrical shorts may not occur at lower voltage levels. In this experiment, we study the effect of varying voltage on the breakdown of the contact resistance which leads to a short circuit. From this data we can estimate the probability of an electrical short, as a function of voltage, given that a free tin whisker has bridged two adjacent exposed electrical conductors. Also, three tin whiskers grown from the same Space Shuttle Orbiter card guide used in the aforementioned experiment were cross-sectioned and studied using a focused ion beam (FIB). The rare polycrystalline structure seen in the FIB cross section was confirmed using transmission electron microscopy (TEM). The FIB was also used to cross section two card guides to facilitate the measurement of the grain size to determine that the tin plating on the card guides had a bright finish.

Courey, Karim J.↗

Tin Whisker Electrical Short Circuit Characteristics Part 2

Existing risk simulations make the assumption that when a free tin whisker has bridged two adjacent exposed electrical conductors, the result is an electrical short circuit. This conservative assumption is made because shorting is a random event that has a currently unknown probability associated with it. Due to contact resistance electrical shorts may not occur at lower voltage levels. In this experiment, we study the effect of varying voltage on the breakdown of the contact resistance which leads to a short circuit. From this data we can estimate the probability of an electrical short, as a function of voltage, given that a free tin whisker has bridged two adjacent exposed electrical conductors. In addition, three tin whiskers grown from the same Space Shuttle Orbiter card guide used in the aforementioned experiment were cross-sectioned and studied using a focused ion beam (FIB).

Courey, Karim J.↗

Are Soft Short Tests Good Indicators of Internal Li-ion Cell Defects?

The self discharge test at full state of charge, may not be a good one to detect subtle defects since the li-ion chemistry has the highest self discharge at full state of charge. One should characterize self discharge versus storage time for each cell manufacturer/design to differentiate between normal self discharge and that due to a subtle manufacturing defect. The various soft short test methods indicate that if this test is carried out at full discharge (0% SOC) with all capacity removed (by lowering the current load in a stepwise manner to the same end of discharge voltage), then the cells need to be placed in storage for more than 72 hours to get a good analysis on the presence of subtle defects since it takes more than 72 hours to achieve voltage stabilization. If the cells are to be charged up even to a small percentage (ex. 1%), 72 hours are sufficient to determine issues. However, the pass/fail criteria should be based on a valid OCV decline. Less than 10 mV voltage decline is not a good method to detect subtle defects. As mentioned in the first bullet, self discharge is a competing reaction when a charge is introduced and hence a characterization of the self discharge versus storage time is required to fully correlate voltage decline to a failure due to a subtle defect. Soft short test method cannot be relied on for defect detection because cells with and without voltage decline seemed to have similar defects and characteristics. Screening methods such as internal resistance and capacity as well as a 3-sigma range for OCV, mass and dimensions should be used to screen out outliers. A very critical aspect in the understanding of subtle defects is to carry out destructive analysis of cells from every lot to confirm the quality of production and screen all cells and batteries in a stringent manner to have a high quality set of flight cells. Self Discharge Test: Fully charged cells shall be placed in Open circuit stand for 72 hours (OCV measurement twice a day); continue for total of 14 days with 1 reading per day 2. Soft Short Test 1: Fully charge; cells discharged to manufacturer's end of disch. Voltage (EODV) cutoff at C/5 rate; stand for 30 minutes; discharge with C/500 to the same EODV. stand for another 30 minutes; discharge the cells again using C/1000 current to the same EODV. OCV measurements twice a day for 72 hours and then for total of 14 days (data collection same as in 1.) 3. Soft Short Test 2: Fully charge; cells discharged to the manuf. EODV with a C/13 constant current; provide a 10 hour rest, discharge again to the same EODV with a current of C/250, provide a 10 hour rest, discharge again using a C/250 rate, provide a 24 hour rest, charge using C/250 to 3.15 V (for ~12 hours). OCV measurements twice a day for at 72 hours. (data collection same as in 1.) 4. Soft Short Test 3: Fully charge; cells shall be discharged using C/10 current to manuf. EODV. Allow the cell to remain at Open circuit for 10 seconds. Discharge the cell at C/20 rate to the same EODV, hold open circuit for 24 hours. Discharge the cells at C/200 rate to the same end of voltage cutoff and hold open circuit for 24 hours. Discharge the cells one more time at C/200 rate to the same EODV and hold open circuit for 36 hours. Charge at C/200 rate to 3.15 V and hold for 3 days. Record OCV during the open circuit stand periods every 12 hours and at the beginning and end of the 3 day hold (include the 12 hour OCV recording during this time also). Capacity Cycling: Cells with declining voltages - one cell from each manufacturer chosen for cycling Destructive Physical Analysis (DPA): Cells with and without decline chosen from each lot for DPA.

Jeevarajan, J.↗

Seat Capacity Selection for an Advanced Short-Haul Aircraft Design

A study was performed to determine the target seat capacity for a proposed advanced short-haul aircraft concept projected to enter the fleet by 2030. This analysis projected the potential demand in the U.S. for a short-haul aircraft using a transportation theory approach, rather than selecting a target seat capacity based on recent industry trends or current market demand. A transportation systems model was used to create a point-to-point network of short-haul trips and then predict the number of annual origin-destination trips on this network. Aircraft of varying seat capacities were used to meet the demand on this network, assuming a single aircraft type for the entire short-haul fleet. For each aircraft size, the ticket revenue and operational costs were used to calculate a total market profitability metric for all feasible flights. The different aircraft sizes were compared, based on this market profitability metric and also the total number of annual round trips and markets served. Sensitivity studies were also performed to determine the effect of changing the aircraft cruise speed and maximum trip length. Using this analysis, the advanced short-haul aircraft design team was able to select a target seat capacity for their design.

Marien, Ty V.↗

2900 Square Degree Search for the Optical Counterpart of Short Gamma-Ray Burst GRB 180523B with the Zwicky Transient Facility

There is significant interest in the models for production of short gamma-ray bursts (GRBs). Until now, the number of known short GRBs with multi-wavelength afterglows has been small. While the Fermi GRB Monitor detects many GRBs relative to the Neil Gehrels Swift Observatory, the large localization regions makes the search for counterparts difficult. With the Zwicky Transient Facility (ZTF - part of Palomar Observatory) recently achieving first light, it is now fruitful to use its combination of depth (m (sub AB) approximating 20.6), field of view (approximately 47 square degrees), and survey cadence (every approximately 3 days) to perform Target of Opportunity observations. We demonstrate this capability on GRB 180523B, which was recently announced by the Fermi GRB Monitor as a short GRB. ZTF imaged 2900 square degrees of the localization region, resulting in the coverage of 61.6 percent of the enclosed probability over two nights to a depth of m (sub AB) approximating 20.5. We characterized 14 previously unidentified transients, and none were found to be consistent with a short GRB counterpart. This search with the ZTF shows it is an efficient camera for searching for coarsely localized short GRB and gravitational-wave counterparts, allowing for a sensitive search with minimal interruption to its nominal cadence.

Coughlin, Michael W.↗