Search NASA⌕ Search

SEARCH · Search NASA

Results for “Signal Processing Power”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Integrated microwave acousto-optic frequency shifter on thin-film lithium niobate

Electrically driven acousto-optic devices that provide beam deflection and optical frequency shifting have broad applications from pulse synthesis to heterodyne detection. Commercially available acousto-optic modulators are based on bulk materials and consume Watts of radio frequency power. Here, we demonstrate an integrated 3-GHz acousto-optic frequency shifter on thin-film lithium niobate, featuring a carrier suppression over 30 dB. Further, we demonstrate a gigahertz-spaced optical frequency comb featuring more than 200 lines over a 0.6-THz optical bandwidth by recirculating the light in an active frequency shifting loop. Our integrated acousto-optic platform leads to the development of on-chip optical routing, isolation, and microwave signal processing.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Algorithm-Driven Advances for Scientific CT Instruments: From model-based to deep learning-based approaches

Multiscale 3D characterization is widely used by materials scientists to further their understanding of the relationships between microscopic structure and macroscopic function. Scientific computed tomography (SCT) instruments are one of the most popular choices for 3D nondestructive characterization of materials at length scales ranging from the angstrom scale to the micron scale. These instruments typically have a source of radiation (such as electrons, X-rays, or neutrons) that interacts with the sample to be studied and a detector assembly to capture the result of this interaction (see Figure 1 ). A collection of such high-resolution measurements is made by reorienting the sample, which is mounted on a specially designed stage/holder after which reconstruction algorithms are used to produce the final 3D volume of interest. The specific choice of which instrument to use depends on the desired resolution and properties of the materials being imaged. Additionally, the end goal of SCT scans includes determining the morphology, chemical composition, or dynamic behavior of materials when subjected to external stimuli. In summary, SCT instruments are powerful tools that enable 3D characterization across multiple length scales and play a critical role in furthering the understanding of the structure–function relationships of different materials.

42 ENGINEERING↗

Commissioning of SRF Cavity Analyzer System

Research and development in Superconducting Radio Frequency (SRF) cavities manufacturing, surface treatment, preparation, and doping techniques for the improvement of cavities performance necessitate reliable cavities’ intrinsic quality factor measurement with accurate and repeatable results. Fermilab Vertical Test Stand facility (VTS) performs ~270 cavities tests per year, including R&D cavities as well as production cavities at each step of their preparation for the placement in accelerator’s cryomodules. Current Fermilab VTS testing system is based on the scalar approach of power measurement, which neglects potential error factors of the RF networks with distributed parameters, hence the assessed measurement errors of such a system might be slightly underestimated. Alternative approach, utilizing a vector measurement (amplitude and phase) of RF signals in the setup with a cavity as a device under test, promises an enhanced accuracy and results traceability. New cavity an alyser system based on this approach (Vector VTS) was developed by D. Frolov et al. and currently undergoes a commissioning process. Basic underlying principles of the system will be presented with the methods of quality factor extraction from S-parameters measurement of multiport cavities and brief error analysis will be discussed. The system architecture will be shown with main components parameters and ensuing testing capabilities. Multiple tests results will be discussed with a cross-check comparison of the results obtained with a conventional testing method. System advantages such as automated calibration process and additional features as a built- in microphonics measurement capability will be presented.

Netepenko, A.↗

Reinforcement learning for real-time process control in high-temperature superconductor manufacturing

With high efficiency and low energy loss, high-temperature superconductors (HTS) have demonstrated their profound applications in various fields, such as medical imaging, transportation, accelerators, microwave devices, and power systems. The high-field applications of HTS tapes have raised the demand for producing cost-effective tapes with long lengths in superconductor manufacturing. However, achieving the uniform and enhanced performance of a long HTS tape is challenging due to the unstable growth conditions in the manufacturing process. Although it is confirmed that the process parameters during the advanced metal organic chemical vapor deposition (A-MOCVD) process influence the uniformity of the produced HTS tapes, the high-dimensional process parameter signals and their complicated interactions make it difficult to develop an effective control policy. In this paper, we propose a local measure for the uniformity of HTS tapes to provide instant feedback for our control policy. Then, we model the manufacturing of HTS tapes as a Markov decision process (MDP) with continuous state and action spaces to assess the instant reward in real time in our feedback control model. As our MDP involves continuous and high-dimensional state and action spaces, a neural fitted Q-iteration (NFQ) algorithm is adopted to solve the MDP with artificial neural network (ANN) function approximation. The collinearity of process parameters can restrict our capability of adjusting the process parameters, which is addressed by the principal component analysis (PCA) in our method. The control policy adjusts the PCA of process parameters using the NFQ algorithm. In conclusion, based on our case studies on real A-MOCVD dataset, the obtained control policy increases the average uniformity of tapes by 5.6% and performs especially well on sample HTS tapes with a low uniformity.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Uncovering acoustic signatures of pore formation in laser powder bed fusion

Abstract We present a machine learning workflow to discover signatures in acoustic measurements that can be utilized to create a low-dimensional model to accurately predict the location of keyhole pores formed during additive manufacturing processes. Acoustic measurements were sampled at 100 kHz during single-layer laser powder bed fusion (LPBF) experiments, and spatio-temporal registration of pore locations was obtained from post-build radiography. Power spectral density (PSD) estimates of the acoustic data were then decomposed using non-negative matrix factorization with custom $$\varvec{k}$$ k -means clustering (NMF $$\varvec{k}$$ k ) to learn the underlying spectral patterns associated with pore formation. NMF $$\varvec{k}$$ k returned a library of basis signals and matching coefficients to blindly construct a feature space based on the PSD estimates in an optimized fashion. Moreover, the NMF $$\varvec{k}$$ k decomposition led to the development of computationally inexpensive machine learning models which are capable of quickly and accurately identifying pore formation with classification accuracy of supervised and unsupervised label learning greater than 95% and 90%, respectively. The intrinsic data compression of NMF k , the relatively light computational cost of the machine learning workflow, and the high classification accuracy makes the proposed workflow an attractive candidate for edge computing toward in-situ keyhole pore prediction in LPBF.

36 MATERIALS SCIENCE↗

QUIJOTE scientific results – IV. A northern sky survey in intensity and polarization at 10–20 GHz with the multifrequency instrument

ABSTRACT We present QUIJOTE intensity and polarization maps in four frequency bands centred around 11, 13, 17, and 19 GHz, and covering approximately 29 000 deg2, including most of the northern sky region. These maps result from 9000 h of observations taken between May 2013 and June 2018 with the first QUIJOTE multifrequency instrument (MFI), and have angular resolutions of around 1°, and sensitivities in polarization within the range 35–40 µK per 1° beam, being a factor ∼2–4 worse in intensity. We discuss the data processing pipeline employed, and the basic characteristics of the maps in terms of real space statistics and angular power spectra. A number of validation tests have been applied to characterize the accuracy of the calibration and the residual level of systematic effects, finding a conservative overall calibration uncertainty of 5 per cent. We also discuss flux densities for four bright celestial sources (Tau A, Cas A, Cyg A, and 3C274), which are often used as calibrators at microwave frequencies. The polarization signal in our maps is dominated by synchrotron emission. The distribution of spectral index values between the 11 GHz and WMAP 23 GHz map peaks at β = −3.09 with a standard deviation of 0.14. The measured BB/EE ratio at scales of ℓ = 80 is 0.26 ± 0.07 for a Galactic cut |b| > 10°. We find a positive TE correlation for 11 GHz at large angular scales (ℓ ≲ 50), while the EB and TB signals are consistent with zero in the multipole range 30 ≲ ℓ ≲ 150. The maps discussed in this paper are publicly available.

Astronomy & Astrophysics↗

On-Line Monitoring of Gas-Phase Molecular Iodine Using Raman and Fluorescence Spectroscopy Paired with Chemometric Analysis

Molten salt reactors (MSRs) have the potential to safely support green energy goals. However, licensing and deployment of these systems will be aided through development of new technology. This includes on-line monitoring tools for real-time compositional analysis. Of particular interest is quantifying iodine within reactor off-gas streams to support design and operational control of reactor off-gas treatment systems. Here we discuss the development of advanced Raman spectroscopy systems for the on-line analysis of I 2(g) within the gas phase. Signal response is explored with two Raman instruments utilizing a 532 nm and a 671 nm excitation source, as a function of I 2(g) pressure and temperature. Furthermore, the applicability of chemometric modeling for advanced analysis of data is explored. Raman spectroscopy paired with chemometric analysis is demonstrated to be a powerful route to analyzing I 2(g) composition within the gas phase, which lays the foundation for applications within molten salt reactor off-gas analysis and other significant chemical processes producing iodine species.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Nonreciprocal Frequency Domain Beam Splitter

The canonical beam splitter—a fundamental building block of quantum optical systems—is a reciprocal element. It operates on forward- and backward-propagating modes in the same way, regardless of direction. The concept of nonreciprocal quantum photonic operations, by contrast, could be used to transform quantum states in a momentum- and direction-selective fashion. In this study, we demonstrate the basis for such a nonreciprocal transformation in the frequency domain through intermodal Bragg scattering four-wave mixing (BSFWM). Since the total number of idler and signal photons is conserved, the process can preserve coherence of quantum optical states, functioning as a nonreciprocal frequency beam splitter. We explore the origin of this nonreciprocity and find that the phase-matching requirements of intermodal BSFWM produce an enormous asymmetry ( 76 × ) in the conversion bandwidths for forward and backward configurations, yielding ~ 25 dB of nonreciprocal contrast over several hundred GHz. We also outline how the demonstrated efficiencies ( ~ 10 – 4 ) may be scaled to near-unity values with readily accessible powers and pumping configurations for applications in integrated quantum photonics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Stable electrospray signal on a microfabricated glass chip with three-dimensional open edge and tiered depth geometries

This paper presents the microfabrication and performance of a three-dimensional electrospray ionization (ESI) emitter tip made from glass, which achieves stable current signals important for chemical analysis. Our novel microfabrication process and custom-built signal conditioning hardware provides the advantage of providing accurate features and steady signals. The fabrication process relies on standard microfabrication techniques (i.e., deposition, photolithography, and wet etching). This fabrication method involves the novel application of two layers of positive and negative photoresists in addition to Parafilm® wax tape. Open edge and tiered depth details were successfully created from a multilayer planar mask. This is a benefit for integrated miniaturized and microfluidic systems that often require micro features for their functionality but relatively large millimeter size features for their physical periphery. We demonstrate the fundamental performance of electrospray with this microfluidic chip. The emitter tip was fixed on a linear axis stage with high resolution (10 μm) to finely control the tip distance from a metal counter electrode plate. Further, a custom printed circuit board system was built to safely control four voltages applied to the microchip ports from a single high voltage power supply. To readily form the electrospray, non-aqueous solvents were used for their low viscosity and a constant voltage of +2.7 kV was applied to the sheath electrospray microchannel. The liquid being sprayed was 80/20 (v/v) methanol/acetonitrile with 0.1% acetic acid in the sheath microchannel and with ammonium acetate (10–40 mM) in its remaining microchannels. The electrospray signal was measured in response to varying the distance (1.4 to 1.6mm) between the electrospray emitter tip and a metal counter electrode plate in addition to the varying concentration of the background electrolyte, ammonium acetate. Stable and repeatable electrospray signal showed linear relationships with emitter tip distance and concentration (r 2 ≥ 0.95).

42 ENGINEERING↗

Ancient Rapid Radiation Explains Most Conflicts Among Gene Trees and Well-Supported Phylogenomic Trees of Nostocalean Cyanobacteria

Prokaryotic genomes are often considered to be mosaics of genes that do not necessarily share the same evolutionary history due to widespread horizontal gene transfers (HGTs). Consequently, representing evolutionary relationships of prokaryotes as bifurcating trees has long been controversial. However, studies reporting conflicts among gene trees derived from phylogenomic data sets have shown that these conflicts can be the result of artifacts or evolutionary processes other than HGT, such as incomplete lineage sorting, low phylogenetic signal, and systematic errors due to substitution model misspecification. Here, we present the results of an extensive exploration of phylogenetic conflicts in the cyanobacterial order Nostocales, for which previous studies have inferred strongly supported conflicting relationships when using different concatenated phylogenomic data sets. We found that most of these conflicts are concentrated in deep clusters of short internodes of the Nostocales phylogeny, where the great majority of individual genes have low resolving power. We then inferred phylogenetic networks to detect HGT events while also accounting for incomplete lineage sorting. Our results indicate that most conflicts among gene trees are likely due to incomplete lineage sorting linked to an ancient rapid radiation, rather than to HGTs. Moreover, the short internodes of this radiation fit the expectations of the anomaly zone, i.e., a region of the tree parameter space where a species tree is discordant with its most likely gene tree. In this work, we demonstrated that concatenation of different sets of loci can recover up to 17 distinct and well-supported relationships within the putative anomaly zone of Nostocales, corresponding to the observed conflicts among well-supported trees based on concatenated data sets from previous studies. Our findings highlight the important role of rapid radiations as a potential cause of strongly conflicting phylogenetic relationships when using phylogenomic data sets of bacteria. We propose that polytomies may be the most appropriate phylogenetic representation of these rapid radiations that are part of anomaly zones, especially when all possible genomic markers have been considered to infer these phylogenies.

59 BASIC BIOLOGICAL SCIENCES↗

Universal signal scaling in microwave impedance microscopy

Microwave impedance microscopy (MIM) is an emerging scanning probe technique that measures the local complex dielectric function using near-field microwave. Although it has made significant impacts in diverse fields, a systematic, quantitative understanding of the signal's dependence on various important design parameters is lacking. Here, we show that for a wide range of MIM implementations, given a complex tip-sample admittance change ΔΥ, the MIM signal—the amplified change in the reflected microwave amplitude—is –G · ΔΥ/2Υ 0 · η 2 · V in , where η is the ratio of the microwave voltage at the probe to the incident microwave amplitude, Y o is the system admittance, and G is the total voltage gain. For linear circuits, η is determined by the circuit design and does not depend on V in . We show that the maximum achievable signal for different designs scales with η 2 or η when limited by input power or sample perturbation, respectively. Furthermore, this universal scaling provides guidance on diverse design goals, including maximizing narrow-band signal for imaging and balancing bandwidth and signal strength for spectroscopy.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Effect of time and spatial domains on monolayer 2D material interface thermal conductance measurement using ns ET-Raman

Raman-based approaches to characterizing thermal properties of nanoscale and microscale materials have proven to be powerful experimental methods. Here, this work explores the potential of energy-transport state-resolved Raman (ET-Raman) for the precise determination of interfacial thermal conductance (G) between monolayer 2D materials and their substrates. ET-Raman employs a continuous wave laser and nanosecond (ns) pulsed laser to induce both steady state and transient heating while simultaneously collecting 2D material temperature information from the Raman signal. A 3D numerical model built using the finite volume method simulates the two differentiated thermal transport processes. The simulated temperature rises are compared with experimental Raman temperature information to extract G. In this study, we investigate the temporal effects of the pulse frequency and pulse width of the ns laser on precise characterization of G. By running multiple simulations for a range of pulsed laser frequencies and pulse widths, we determine that ET-Raman is most sensitive to precise interfacial thermal conductance measurements with short pulse widths (~below 20 ns) and with pulsing frequencies that ensure sufficient cooling time between consecutive pulses (~below 500 kHz). We also conclude that substrate thickness and laser spot size play critical roles in heat distribution and subsequent sensitivity to meaningful G measurements. As both laser spot size and SiO 2 substrate thickness decrease, detection of interfacial thermal transport becomes more difficult. These results offer essential guidance in the design of future Raman-based approaches to thermal measurements using pulsed lasers.

2D materials↗

Sensors with Intelligent Measurement Platform and Low-cost Equipment (SIMPLE) – Performance Characterization

Design and performance of a digital signal processing platform for enhancing off-the-shelf voltage and current sensors are presented. The platform was developed for enabling advanced distribution grid applications with existing low-cost sensors. This digital sensor system leverages a variety of off-the-shelf voltage and current sensing technologies, analog-to-digital conversion, and sensor correction algorithms to yield more accurate and reliable digital measurements that support a multitude of applications and use cases. Sample performance and accuracy results are provided, including measurements at power frequency and higher harmonics. The system extends the native performance of the medium voltage sensors used in the system, for example, broadening measurement bandwidth beyond a few kHz, appropriate for measuring switching surges and harmonics on medium voltage distribution systems. The digital sensor system is installed and characterized in the field with a high-bandwidth optical calibration system to determine site-dependent calibration and performance issues.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Combustion Performance and Emissions Optimization through Integration of Miniaturized High Temperature Multi Process Monitoring System

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings. The mMPMS is based on an electrochemical sensor that provides a real-time indication of the risk of damage to key locations in the radiant or convective section of a coal-fired boiler such as metal loss rates, heat flux, metal surface temperature, and deposit thickness. These indications can be utilized to optimize boiler performance as well as improve boiler availability in conjunction with corresponding operating conditions. This monitoring system was developed and tested in the high-temperature regions of coal-fired utility boilers in this project but can be applied to many other industries and applications as well. The new sensor design, leveraging the existing electrochemical noise-based monitoring system, is small enough to be installed through the webbing of the waterwalls without the need for long shut-downs to bend tubes and to make it feasible to obtain high spatial resolution in the boiler. Data can be transferred to the plant distributed control system (DCS) and any other control system. The sensor body that houses the sensor assembly was designed to ensure good conductive contact with boiler tubes to ensure the sensor is held at an identical temperature to the tube surface temperature. The data acquisition and signal conditioning modules were redesigned into a small footprint with optimized cooling of the module. System software was developed specifically for the new signal conditioning module and is compatible with plant PLCs. After the preliminary testing at a pilot-scale facility, five mMPMS were installed at a full-scale pulverized coal-fired plant, Basin Electric Power Cooperative’s Leland Olds Unit 1. The systems were demonstrated over a 6-week period during typical operation. Sensor measurements of deposit thickness were validated during the demonstration and subsequently leveraged to determine sensor-based boiler cleaning strategies. These strategies have the benefit of reduced thermal stresses on boiler tubes from over-cleaning and improved boiler water management. At the end of the project, continued development of the sensor technology was carried out at PacifiCorp’s Hunter Station. REI leveraged the permanent installation of the mMPMS in Unit 3 made possible by DOE funding on a separate program. The work at Hunter Plant focused on application of machine learning and artificial intelligence-based models for integration of sensor signals into control and optimization of Hunter Unit 3 processes.

Advanced Sensors, Corrosion, Ash Deposition, Optim↗

Combustion Performance and Emissions Optimization Through Integration of a Miniaturized High-Temperature Multi Process Monitoring System

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings. The mMPMS is based on an electrochemical sensor that provides a real-time indication of the risk of damage to key locations in the radiant or convective section of a coal-fired boiler such as metal loss rates, heat flux, metal surface temperature, and deposit thickness. These indications can be utilized to optimize boiler performance as well as improve boiler availability in conjunction with corresponding operating conditions. This monitoring system was developed and tested in the high-temperature regions of coal-fired utility boilers in this project but can be applied to many other industries and applications as well. The new sensor design, leveraging the existing electrochemical noise-based monitoring system, is small enough to be installed through the webbing of the waterwalls without the need for long shut-downs to bend tubes and to make it feasible to obtain high spatial resolution in the boiler. Data can be transferred to the plant distributed control system (DCS) and any other control system. The sensor body that houses the sensor assembly was designed to ensure good conductive contact with boiler tubes to ensure the sensor is held at an identical temperature to the tube surface temperature. The data acquisition and signal conditioning modules were redesigned into a small footprint with optimized cooling of the module. System software was developed specifically for the new signal conditioning module and is compatible with plant PLCs. After the preliminary testing at a pilot-scale facility, five mMPMS were installed at a full-scale pulverized coal-fired plant, Basin Electric Power Cooperative’s Leland Olds Unit 1. The systems were demonstrated over a 6-week period during typical operation. Sensor measurements of deposit thickness were validated during the demonstration and subsequently leveraged to determine sensor-based boiler cleaning strategies. These strategies have the benefit of reduced thermal stresses on boiler tubes from over-cleaning and improved boiler water management. At the end of the project, continued development of the sensor technology was carried out at PacifiCorp’s Hunter Station. REI leveraged the permanent installation of the mMPMS in Unit 3 made possible by DOE funding on a separate program. The work at Hunter Plant focused on application of machine learning and artificial intelligence-based models for integration of sensor signals into control and optimization of Hunter Unit 3 processes.

Advanced Sensors, Corrosion, Ash Deposition, Optim↗

Faster Johnson–Lindenstrauss transforms via Kronecker products

The Kronecker product is an important matrix operation with a wide range of applications in signal processing, graph theory, quantum computing and deep learning. In this work, we introduce a generalization of the fast Johnson–Lindenstrauss projection for embedding vectors with Kronecker product structure, the Kronecker fast Johnson–Lindenstrauss transform (KFJLT). The KFJLT reduces the embedding cost by an exponential factor of the standard fast Johnson–Lindenstrauss transform’s cost when applied to vectors with Kronecker structure, by avoiding explicitly forming the full Kronecker products. Here, we prove that this computational gain comes with only a small price in embedding power: consider a finite set of $p$ points in a tensor product of $d$ constituent Euclidean spaces $\bigotimes _{k=d}^{1}{\mathbb{R}}^{n_k}$, and let $N = \prod _{k=1}^{d}n_k$. With high probability, a random KFJLT matrix of dimension $m \times N$ embeds the set of points up to multiplicative distortion $(1\pm \varepsilon )$ provided $m \gtrsim \varepsilon ^{-2} \, \log ^{2d - 1} (p) \, \log N$. We conclude by describing a direct application of the KFJLT to the efficient solution of large-scale Kronecker-structured least squares problems for fitting the CP tensor decomposition.

Kronecker structure↗

Assessment of Impurities in Neptunium Metal Using Double-Focusing SF-ICP-MS

In the transmutation process, minor actinides such as neptunium, americium and curium obtained from spent nuclear fuel are incorporated into new fuel that can be placed into a fast reactor, where these elements fission into products with shorter half-lives which reduces the health and safety hazards. In order to better understand the all the involved processes, fundamental physical properties of actinides should be investigated, and for that reason, high-purity materials need to be produced. One of the main challenges in characterizing these materials is the lack of pure metal available for study, and lack of analytical methods to determine the purity. Trans-uranic elements are challenging to study because of the need to be handled in specialized facilities, safeguards concerns and they are not easily purchased and/or produced. High-purity Np metal is being produced at the Materials and Fuels Complex (MFC) of Idaho National Laboratory (INL), in a process of direct oxide reduction developed by Squires and Lessing, with a target purity of 99.999%. The goal of this research is to develop methods to determine the impurities in the Np metal, with detection limits low enough to achieve this purity level. In this work, we have used several ICP-MS and ICP OES techniques, but the focus was the method development using a recently acquired Double-Focusing Sector Field Inductively Coupled Plasma Mass Spectrometer (SF-ICP-MS). To produce the Np metal, approximately 20 g of the neptunium oxide powder was calcined at 800 oC for 6 h in a magnesium oxide crucible, which is placed inside a stainless steel crucible, that goes into the Hot Uniaxial Press (HUP) furnace insert. After the calcining step, the Np oxide was mixed with approximately 9 g of calcium metal and 100 g of ultra-dry calcium chloride. The HUP furnace was heated in a ramp rate of 50 oC min -1 up to 1000 oC. When the reaction mixture reached 850 oC, a tantalum stirrer was activated at 100 rpm. After the tantalum stirrer was removed and the mixture cooled overnight, the MgO crucible was opened with a hammer and chisel to retrieve the Np metal button at the bottom of the reaction mixture. Prior to the dissolution process, the surface contaminants of the sample were removed. The Np button was washed in 10 mL of ultra-pure water for 1 min, with a faint reaction observed on the surface, indicating the presence of Ca metal. The water-washed sample was placed in a tube with 2 M HCl for only 3 s, as a vigorous reaction in the button surface was observed. The leachates were saved for further analysis. The sample was then rinsed with ultra-pure water and air-dried prior to dissolution. The cleaned sample was placed in a PTFE beaker and 25 mL of 6 M HCl and 150 µL of 24 M HF were added. After 10 minutes of reaction, the beaker was placed on a hot plate for 1 h and 30 min, followed by the addition of 1 mL of 16 M HNO3 and allowed to react for a further 1 h and 20 min. The sample was removed from heat and 10 mL of HNO3 16 M was added to react with the HCl. The beaker was covered and left for overnight reaction, producing a solution with approximately 20 mL of final volume. A Quadrupole Inductively Coupled Plasma Mass Spectrometer (Q-ICP-MS, Perkin Elmer ELAN DRC II Q-ICP-MS) was used to obtain qualitative mass spectra for the dissolution blank, each of the leachates and the dissolved sample. In the water leachate spectrum mainly Ca and Mg were observed, while the acid wash had a similar peak pattern to the one observed for the Np metal sample, indicating that the process not only removed surface contamination, but also reacted with the sample itself. In the Np material spectrum, Ta and actinides were identified as candidates for major contaminants, as the most intense peaks corresponded to the mass-to-charge ratios of these elements. Minor contaminants included Al, Au, Ca, Cr, Fe, I, Na, Nb, Pb, Sn, Ti, Tl, V, Y. The presence of impurities in the material could have originated from several sources, such as the materials used for the casting process, the use of impure NpO2 or contamination of reagents and materials used for the analysis. Some of the isotopes listed as potential contaminants are susceptible to spectral interferences, so Double-Focusing SF-ICP-MS (Nu Instruments Attom ES HR-ICP-MS) was used for the quantitative analysis. For each isotope determined, several items were evaluated: raw signal of a blank solution, sensitivity and determination coefficient of calibration curves, possibility of interferences and comparison of results obtained for at least two resolving powers (RP): 300 and 4000. The evaluation of the signal in a blank solution can indicate if a spectral interference from the plasma gas and/or the solvent was successfully resolved (commonly observed for 52Cr+/40Ar12C+, for example). It is important to highlight that a signal reduction is expected when a higher RP is used, as the ion beam transmission is decreased by the use of narrower slits

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Leveraging FPGA Advantages for Quicker Data Processing for LBNF

The Long Baseline Neutrino Facility (LBNF) will deliver a 2.4 MW muon neutrino beam from Fermilab to the Deep Underground Neutrino Experiment (DUNE), requiring unprecedented precision in beamline alignment to achieve DUNE's neutrino oscillation measurement goals. Vertical misalignments of beamline components as small as 0.5 mm can contribute 6-7\% uncertainty in predicted neutrino flux, necessitating sub-0.1 mm alignment monitoring capabilities. The Horn Location Sensor (HLS) system employs frequency sweep interferometry (FSI) in a distributed hydrostatic leveling network to achieve the required precision under harsh radiation conditions up to 5000 kRad/year. Traditional FSI implementations suffer from laser sweep nonlinearities that degrade resolution and require computationally intensive post-processing corrections using gas reference cells. This work presents a real-time FPGA-based implementation of the HLS data acquisition and processing system using a sweep tracker interferometer for dynamic sweep linearization. The system utilizes a PYNQ-Z2 FPGA with programmable logic implementing parallel 16k-point FFT processing across four channels, synchronized by the sweep tracker signal to eliminate post-processing requirements. Spectral performance testing demonstrates significant improvements in peak sharpness compared to traditional fixed-frequency digitization. The FPGA implementation enables real-time displacement monitoring with processing speeds orders of magnitude faster than software-based approaches, essential for the operational requirements of LBNF's eventual distributed sensor network. This advancement in real-time FSI processing directly supports DUNE's precision neutrino physics program by providing the rapid feedback necessary for maintaining stringent beamline alignment tolerances during high-power beam operations.

Rossel, Jacob↗