Search NASA⌕ Search

SEARCH · Search NASA

Results for “Signal Reconstruction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Shuttle Ku-band signal design study

Carrier synchronization and data demodulation of Unbalanced Quadriphase Shift Keyed (UQPSK) Shuttle communications' signals by optimum and suboptimum methods are discussed. The problem of analyzing carrier reconstruction techniques for unbalanced QPSK signal formats is addressed. An evaluation of the demodulation approach of the Ku-Band Shuttle return link for UQPSK when the I-Q channel power ratio is large is carried out. The effects that Shuttle rocket motor plumes have on the RF communications are determined also. The effect of data asymmetry on bit error probability is discussed.

Lindsey, W. C.↗

Observation of Bs-Bsbar Oscillations Using Partially Reconstructed Hadronic Bs Decays

This thesis describes the contribution of partially reconstructed hadronic decays in the world's first observation of B$0\atop{s}$-$\bar{B}$$0\atop{s}$ oscillations. The analysis is a core member of a suite of closely related studies whose combined time-dependent measurement of the B$0\atop{s}$-$\bar{B}$$0\atop{s}$ oscillation frequency Δm s is of historic significance. Using a data sample of 1 fb -1 of p$\bar{p}$ collisions at √s = 1.96 TeV collected with the CDF-II detector at the Fermilab Tevatron, they find signals of 3150 partially reconstructed hadronic B s decays from the combined decay channels B$0\atop{s}$ → D*$-\atop{s}$ π + and B$0\atop{s}$ → D$-\atop{s}$ ρ + with D$-\atop{s}$ → Φπ - . These events are analyzed in parallel with 2000 fully reconstructed B$0\atop{s}$ → D$-\atop{s}$ π + (D$-\atop{s}$ → Φπ - ) decays. The treatment of the data is developed in stages of progressive complexity, using high-statistics samples of hadronic B 0 and B + decays to study the attributes of partially reconstructed events. The analysis characterizes the data in mass and proper decay time, noting the potential of the partially reconstructed decays for precise measurement of B branching fractions and lifetimes, but consistently focusing on the effectiveness of the model for the oscillation measurement. They efficiently incorporate the measured quantities of each decay into a maximum likelihood fitting framework, from which they extract amplitude scans and a direct measurement of the oscillation frequency. The features of the amplitude scans are consistent with expected behavior, supporting the correctness of the calibrations for proper time uncertainty and flavor tagging dilution. The likelihood allows for the smooth combination of this analysis with results from other data samples, including 3500 fully reconstructed hadronic B s events and 61,500 partially reconstructed semileptonic B s events. The individual analyses show compelling evidence for B$0\atop{s}$-$\bar{B}$$0\atop{s}$ oscillations, and the combination yields a clear signal. The probability that random fluctuations could produce a comparable signature is 8 x 10 -8 , which exceeds the 5 standard deviations threshold of significance for observation. The discovery threshold would not be achieved without inclusion of the partially reconstructed hadronic decays. They measure Δm s = 17.77 ± 0.10(stat) ± 0.07(syst) ps -1 and extract |V td /V ts | = 0.2060 ± 0.0007(exp)$+0.0081\atop{-0.0060}$(theory), consistent with the Standard Model expectation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Effects of asymmetric passband filtering on the phase of the Costas loop's reconstructed carrier

The reconstructed carrier of a telemetry return signal is used in deriving the Doppler and range information in the radiometric systems. When suppressed carrier BPSK signalling with Costas loop demodulation is used, there are concerns on the amount of shift in the reconstructed carrier phase, when the received signal suffers asymmetric bandpass filtering through the various stages of the receiver. It is concluded that the phase shifts due to asymmetric bandpass filtering on the Costas loop's reconstructed carrier can be slightly worse than those suffered by the residual carrier loop's reconstructed carrier. However, they are well within the error budgets of the radiometric system.

Woo, K. T.↗

Deep-Learning based Reconstruction of the Shower Maximum $X_{\mathrm{max}}$ using the Water-Cherenkov Detectors of the Pierre Auger Observatory

The atmospheric depth of the air shower maximum X max is an observable commonly used for the determination of the nuclear mass composition of ultra-high energy cosmic rays. Direct measurements of X max are performed using observations of the longitudinal shower development with fluorescence telescopes. At the same time, several methods have been proposed for an indirect estimation of X max from the characteristics of the shower particles registered with surface detector arrays. In this paper, we present a deep neural network (DNN) for the estimation of X max . The reconstruction relies on the signals induced by shower particles in the ground based water-Cherenkov detectors of the Pierre Auger Observatory. The network architecture features recurrent long short-term memory layers to process the temporal structure of signals and hexagonal convolutions to exploit the symmetry of the surface detector array. We evaluate the performance of the network using air showers simulated with three different hadronic interaction models. Thereafter, we account for long-term detector effects and calibrate the reconstructed X max using fluorescence measurements. Finally, we show that the event-by-event resolution in the reconstruction of the shower maximum improves with increasing shower energy and reaches less than 25 g/cm 2 at energies above 2 × 10 19 eV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluating the Utility of Pressure Scanners for Unsteady Pressure Measurements in Wind Tunnel Characterization of the Space Launch System

In many aerodynamic measurement applications, the ability to make time-accurate measurements with pressure scanners provides practical advantages over making the same measurements directly using flush-mounted transducers. The pneumatic distortion due to the tubing between the sensing module and surface port limits the usefulness of such measurements to averaged, steady data only. This issue has restricted the application of pressure scanners for unsteady pressure measurements in wind tunnel and flight-testing applications. The Wiener-filtered inverse system response model has been proven to be effective in reconstructing complex unsteady pressure signals acquired remotely using pressure scanners. In this work, the feasibility of using pressure scanning systems for time-resolved pressure measurements in the NASA Langley 14- by 22-Foot Subsonic Wind Tunnel was evaluated. Results demonstrated good agreement between the reference transducers and reconstructed pressure scanner measurements up to frequencies of approximately 500 Hz.

Unsteady pressure↗

The Impact of Reconstruction in Pandora on Sensitivity to the Low-Energy Excess Signal at MicroBooNE

With the MicroBooNE collaboration’s first low-energy excess (LEE) searches complete and twice the amount of data to analyse in future iterations, it is imperative that we begin considering the potential analysis upgrades that can be achieved, such as those in the event reconstruction level. This note identifies the areas in Pandora reconstruction framework that could be improved upon, and evaluates their impact through cheated selections using MicroBooNE’s exclusive pionless LEE search as a benchmark. Vertexing and proton reconstruction improvements are demonstrated to have significant potential benefits in terms of sensitivity to the LEE signal and thus should be prioritised. Sensitivity projections for the full 10.1e20 POT are 3.2σ and 2.3σ for vertex and proton cheated selections respectively, and 3.3σ for the combined effect of both, compared to 2.1σ in the absence of the cheated selections.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The electronically steered thinned array radiometer

An L-band radiometer which allows global imaging of soil moisture from LEO is discussed. The system consists of an array of antennas with amplifiers, a device to cross-correlate the signals from the antennas, and a process to translate the resulting data into an image of brightness temperature over the field of view. The process is based on a Fourier transform relation that exists between the incident electric field strength as a function of incidence angle and electric fields across the aperture plane of the antenna. The system's image reconstruction technique and signal-to-noise performance are examined.

Ruf, C. S.↗

Model-Based Reconstruction for Collimated Beam Ultrasound Systems

Collimated beam ultrasound systems are a novel technology for imaging inside multi-layered structures such as geothermal wells. Such systems include a transmitter and multiple receivers to capture reflected signals. Common algorithms for ultrasound reconstruction use delay-and-sum (DAS) approaches; these have low computational complexity but produce inaccurate images in the presence of complex structures and specialized geometries such as collimated beams.In this paper, we propose a multi-layer, ultrasonic, model-based iterative reconstruction algorithm designed for collimated beam systems. We introduce a physics-based forward model to accurately ac-count for the propagation of a collimated ultrasonic beam in multi-layer media and describe an efficient implementation using binary search. We model direct arrival signals, detector noise, and a spatially varying image prior, then cast the reconstruction as a maximum a posteriori estimation problem. Using simulated and experimental data we obtain significantly fewer artifacts relative to DAS while running in near real time using commodity compute resources.

Alanazi, Abdulrahman M.↗

Boosting the signal-to-noise of low-field MRI with deep learning image reconstruction

Recent years have seen a resurgence of interest in inexpensive low magnetic field (< 0.3 T) MRI systems mainly due to advances in magnet, coil and gradient set designs. Most of these advances have focused on improving hardware and signal acquisition strategies, and far less on the use of advanced image reconstruction methods to improve attainable image quality at low field. We describe here the use of our end-to-end deep neural network approach (AUTOMAP) to improve the image quality of highly noise-corrupted low-field MRI data. We compare the performance of this approach to two additional state-of-the-art denoising pipelines. We find that AUTOMAP improves image reconstruction of data acquired on two very different low-field MRI systems: human brain data acquired at 6.5 mT, and plant root data acquired at 47 mT, demonstrating SNR gains above Fourier reconstruction by factors of 1.5- to 4.5-fold, and 3-fold, respectively. In these applications, AUTOMAP outperformed two different contemporary image-based denoising algorithms, and suppressed noise-like spike artifacts in the reconstructed images. The impact of domain-specific training corpora on the reconstruction performance is discussed. The AUTOMAP approach to image reconstruction will enable significant image quality improvements at low-field, especially in highly noise-corrupted environments.

42 ENGINEERING↗

An adaptive filtered back-projection for photoacoustic image reconstruction

Purpose: The purpose of this study is to develop an improved filtered-back-projection (FBP) algorithm for photoacoustic tomography (PAT), which allows image reconstruction with higher quality compared to images reconstructed through traditional algorithms. Methods: A rigorous expression of a weighting function has been derived directly from a photoacoustic wave equation and used as a ramp filter in Fourier domain. The authors’ new algorithm utilizes this weighting function to precisely calculate each photoacoustic signal’s contribution and then reconstructs the image based on the retarded potential generated from the photoacoustic sources. In addition, an adaptive criterion has been derived for selecting the cutoff frequency of a low pass filter. Two computational phantoms were created to test the algorithm. The first phantom contained five spheres with each sphere having different absorbances. The phantom was used to test the capability for correctly representing both the geometry and the relative absorbed energy in a planar measurement system. The authors also used another phantom containing absorbers of different sizes with overlapping geometry to evaluate the performance of the new method for complicated geometry. In addition, random noise background was added to the simulated data, which were obtained by using an arc-shaped array of 50 evenly distributed transducers that spanned 160° over a circle with a radius of 65 mm. A normalized factor between the neighbored transducers was applied for correcting measurement signals in PAT simulations. The authors assumed that the scanned object was mounted on a holder that rotated over the full 360° and the scans were set to a sampling rate of 20.48 MHz. Results: The authors have obtained reconstructed images of the computerized phantoms by utilizing the new FBP algorithm. From the reconstructed image of the first phantom, one can see that this new approach allows not only obtaining a sharp image but also showing the correct signal strength of the absorbers. The reconstructed image of the second phantom further demonstrates the capability to form clear images of the spheres with sharp borders in the overlapping geometry. The smallest sphere is clearly visible and distinguishable, even though it is surrounded by two big spheres. In addition, image reconstructions were conducted with randomized noise added to the observed signals to mimic realistic experimental conditions. Conclusions: The authors have developed a new FBP algorithm that is capable for reconstructing high quality images with correct relative intensities and sharp borders for PAT. The results demonstrate that the weighting function serves as a precise ramp filter for processing the observed signals in the Fourier domain. In addition, this algorithm allows an adaptive determination of the cutoff frequency for the applied low pass filter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Roller Bearing Health Monitoring Using CPLE Frequency Analysis Method

This paper describes a unique vibration signature analysis technique Coherence Phase Line Enhancer (CPLE) Frequency Analysis - for roller bearing health monitoring. Defects of roller bearing (e.g. wear, foreign debris, crack in bearing supporting structure, etc.) can cause small bearing characteristic frequency shifts due to minor changes in bearing geometry. Such frequency shifts are often too small to detect by the conventional Power Spectral Density (PSD) due to its frequency bandwidth limitation. This Coherent Phase Line Enhancer technology has been evolving over the last few years and has culminated in the introduction of a new and novel frequency spectrum which is fully described in this paper. This CPLE technology uses a "key phasor" or speed probe as a preprocessor for this analysis. With the aid of this key phasor, this CPLE technology can develop a two dimensional frequency spectrum that preserves both amplitude and phase that is not normally obtained using conventional frequency analysis. This two-dimensional frequency transformation results in several newly defined spectral functions; i. e. CPLE-PSD, CPLE-Coherence and the CPLE-Frequency. This paper uses this CPLE frequency analysis to detect subtle, low level bearing related signals in the High Pressure Fuel Pump (HPFP) of the Space Shuttle Main Engine (SSME). For many rotating machinery applications, a key phasor is an essential measurement that is used in the detection of bearing related signatures. There are times however, when a key phasor is not available; i. e. during flight of any of the SSME turbopumps or on the SSME High Pressure Oxygen Turbopump (HPOTP) where no speed probe is present. In this case, the CPLE analysis approach can still be achieved using a novel Pseudo Key Phasor (PKP) technique to reconstruct a 1/Rev PKP signal directly from external vibration measurements. This paper develops this Pseudo Key Phasor technique and applies it to the SSME vibration data.

Jong, Jen-Yi↗

Reconstruction for Liquid Argon TPC Neutrino Detectors Using Parallel Architectures.

Neutrinos are particles that interact rarely, so identifying them re-quires large detectors which produce lots of data. Processing this data with thecomputing power available is becoming more dicult as the detectors increasein size to reach their physics goals. In liquid argon time projection chambers(TPCs) the charged particles from neutrino interactions produce ionization elec-trons which drift in an electric field towards a series of collection wires, and thesignal on the wires is used to reconstruct the interaction. The MicroBooNEdetector currently collecting data at Fermilab has 8000 wires, and planned fu-ture experiments like DUNE will have 100 times more, which means that thetime required to reconstruct an event will scale accordingly. Modernization ofliquid argon TPC reconstruction code, including vectorization, parallelizationand code portability to GPUs, will help to mitigate these challenges. The liquidargon TPC hit finding algorithm within theLArSoftframework used acrossmultiple experiments has been vectorized and parallelized. This increases thespeed of the algorithm on the order of ten times within a standalone version onIntel architectures. This new version has been incorporated back intoLArSoftso that it can be generally used. These methods will also be applied to otherlow-level reconstruction algorithms of the wire signals such as the deconvolu-tion. The applications and performance of this modernized liquid argon TPCwire reconstruction will be presented.

Berkman, Sophie↗

Measurement of the top quark mass and pp{yields}tt cross section in the all-hadronic mode with the CDF II detector

We present a measurement of the top quark mass and of the top-antitop (tt) pair production cross section using pp data collected with the CDF II detector at the Tevatron Collider at the Fermi National Accelerator Laboratory and corresponding to an integrated luminosity of 2.9 fb{sup -1}. We select events with six or more jets satisfying a number of kinematical requirements imposed by means of a neural-network algorithm. At least one of these jets must originate from a b quark, as identified by the reconstruction of a secondary vertex inside the jet. The mass measurement is based on a likelihood fit incorporating reconstructed mass distributions representative of signal and background, where the absolute jet energy scale (JES) is measured simultaneously with the top quark mass. The measurement yields a value of 174.8{+-}2.4(stat+JES){sub -1.0}{sup +1.2}(syst) GeV/c{sup 2}, where the uncertainty from the absolute jet energy scale is evaluated together with the statistical uncertainty. The procedure also measures the amount of signal from which we derive a cross section, {sigma}{sub tt}=7.2{+-}0.5(stat){+-}1.0(syst){+-}0.4(lum) pb, for the measured values of top quark mass and JES.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for B{yields}h{sup (*)}{nu}{nu} Decays at Belle

We present a search for the rare decays B{yields}h{sup (*)}{nu}{nu}, where h{sup (*)} stands for a light meson. A data sample of 535x10{sup 6} BB pairs collected with the Belle detector at the KEKB e{sup +}e{sup -} collider is used. Signal candidates are required to have an accompanying B meson fully reconstructed in a hadronic mode and signal side particles consistent with a single h{sup (*)} meson. No significant signal is observed and we set upper limits on the branching fractions at 90% confidence level. The limits on B{sup 0}{yields}K*{sup 0}{nu}{nu} and B{sup +}{yields}K{sup +}{nu}{nu} decays are more stringent than the previous constraints, while the first searches for B{sup 0}{yields}K{sup 0}{nu}{nu}, {pi}{sup 0}{nu}{nu}, {rho}{sup 0}{nu}{nu}, {phi}{nu}{nu} and B{sup +}{yields}K*{sup +}{nu}{nu}, {rho}{sup +}{nu}{nu} are reported.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Improving small-scale CMB lensing reconstruction

Over the past decade, the gravitational lensing of the Cosmic Microwave Background (CMB) has become a powerful tool for probing the matter distribution in the Universe. The standard technique used to reconstruct the CMB lensing signal employs the quadratic estimator (QE) method, which has recently been shown to be suboptimal for lensing measurements on very small scales in temperature and polarization data. We implement a simple, more optimal method for the small-scale regime, which involves taking the direct inverse of the background gradient. We derive new techniques to make continuous maps of lensing using this "Gradient-Inversion" (GI) method and validate our method with simulated data, finding good agreement with predictions. For idealized simulations of lensing cross- and autospectra that neglect foregrounds, we demonstrate that our method performs significantly better than previous quadratic estimator methods in temperature; at $L=5000-9000$, it reduces errors on the lensing auto-power spectrum by a factor of $\sim 4$ for both idealized CMB-S4 and Simons Observatory-like experiments and by a factor of $\sim 2.6$ for cross-correlations of CMB-S4-like lensing reconstruction and the true lensing field. Finally, we caution that the level of the neglected small-scale foreground power, while low in polarization, is very high in temperature; though we briefly outline foreground mitigation methods, further work on this topic is required. Nevertheless, our results show the future potential for improved small-scale CMB lensing measurements, which could provide stronger constraints on cosmological parameters and astrophysics at high redshifts.

79 ASTRONOMY AND ASTROPHYSICS↗

A multidimensional approach to quantum state tomography of photoelectron wavepackets

There is a growing interest in reconstructing the density matrix of photoelectron wavepackets, in particular in complex systems where decoherence can be introduced either by a partial measurement of the system or through coupling with a stochastic environment. To this end, several methods to reconstruct the density matrix, quantum state tomography protocols, have been developed and tested on photoelectrons ejected from noble gases following absorption of extreme ultraviolet (XUV) photons from attosecond pulses. It remains a challenge to obtain model-free, single scan protocols that can reconstruct the density matrix with high fidelities. Current methods require extensive measurements or involve complex fitting of the signal. Efficient single-scan reconstructions would be of great help to increase the number of systems that can be studied. We propose a new and more efficient protocol that is able to reconstruct the continuous variable density matrix of a photoelectron in a single time delay scan. It is based on measuring the coherences of a photoelectron created by absorption of an XUV pulse using a broadband infrared (IR) probe that is scanned in time and a narrowband IR reference that is temporally fixed to the XUV pulse. We illustrate its performance for a Fano resonance in He as well as mixed states in Ar arising from spin-orbit splitting. We show that the protocol results in excellent fidelities and near-perfect estimation of the purity.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Synthetic CT: Simulating low dose single and dual energy protocols from a dual energy scan

Purpose: The choice of CT protocol can greatly impact patient dose and image quality. Since acquiring multiple scans at different techniques on a given patient is undesirable, the ability to predict image quality changes starting from a high quality exam can be quite useful. While existing methods allow one to generate simulated images of lower exposure (mAs) from an acquired CT exam, the authors present and validate a new method called synthetic CT that can generate realistic images of a patient at arbitrary low dose protocols (kVp, mAs, and filtration) for both single and dual energy scans. Methods: The synthetic CT algorithm is derived by carefully ensuring that the expected signal and noise are accurate for the simulated protocol. The method relies on the observation that the material decomposition from a dual energy CT scan allows the transmission of an arbitrary spectrum to be predicted. It requires an initial dual energy scan of the patient to either synthesize raw projections of a single energy scan or synthesize the material decompositions of a dual energy scan. The initial dual energy scan contributes inherent noise to the synthesized projections that must be accounted for before adding more noise to simulate low dose protocols. Therefore, synthetic CT is subject to the constraint that the synthesized data have noise greater than the inherent noise. The authors experimentally validated the synthetic CT algorithm across a range of protocols using a dual energy scan of an acrylic phantom with solutions of different iodine concentrations. An initial 80/140 kVp dual energy scan of the phantom provided the material decomposition necessary to synthesize images at 100 kVp and at 120 kVp, across a range of mAs values. They compared these synthesized single energy scans of the phantom to actual scans at the same protocols. Furthermore, material decompositions of a 100/120 kVp dual energy scan are synthesized by adding correlated noise to the initial material decompositions. The aforementioned noise constraint also allows us to compute feasible mAs values that can be synthesized for each kVp. Results: The single energy synthesized and actual reconstructed images exhibit identical signal and noise properties at 100 kVp and at 120 kVp, and across a range of mAs values. For example, the noise in both the synthesized and actual images at 100 kVp increases by {radical}(2) when the mAs is halved. The synthesized and actual material decompositions of a dual energy protocol show excellent agreement when the decomposition images are linearly weighted to form monoenergetic images at energies from 40 to 100 keV. For simulated single energy protocols with kVp between 80 and 140, the highest feasible mAs exceeds that of either initial scan. Conclusions: This work describes and validates the synthetic CT theory and algorithm by comparing its results to actual scans. Synthetic CT is a powerful new tool that allows users to realistically see how protocol selection affects CT images and enables radiologists to retrospectively identify the lowest dose protocol achievable that provides diagnostic quality images on real patients.

61 RADIATION PROTECTION AND DOSIMETRY↗

Fast algorithms for nonconvex compression sensing: MRI reconstruction from very few data

Compressive sensing is the reconstruction of sparse images or signals from very few samples, by means of solving a tractable optimization problem. In the context of MRI, this can allow reconstruction from many fewer k-space samples, thereby reducing scanning time. Previous work has shown that nonconvex optimization reduces still further the number of samples required for reconstruction, while still being tractable. In this work, we extend recent Fourier-based algorithms for convex optimization to the nonconvex setting, and obtain methods that combine the reconstruction abilities of previous nonconvex approaches with the computational speed of state-of-the-art convex methods.

99 GENERAL AND MISCELLANEOUS↗