Search NASA⌕ Search

SEARCH · Search NASA

Results for “Signal detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Stimulus configuration determines the detectability of motion signals in noise

We measured the detectability of moving signal dots in dynamic noise to determine whether local motion signals are preferentially combined along an axis parallel to the direction of motion. Observers were asked to detect a signal composed of three dots moving in a linear trajectory among dynamic noise dots. The signal dots were collinear and equally spaced in a configuration that was either parallel to or perpendicular to their trajectory. The probability of detecting the signal was measured as a function of noise density, over a range of signal dot spacings from 0.5 degrees to 5.0 degrees. At any given noise density, the signal in the parallel configuration was more detectable than that in the perpendicular configuration. Our four observers could tolerate 1.5-2.5 times more noise in the parallel configuration. This improvement is not due merely to temporal summation between consecutive dots in the parallel trajectory. Temporal summation functions measured on our observers indicate that the benefit from spatial coincidence of the dots lasts for no more than 50 ms, whereas the increased detectability of the parallel configuration is observed up to the largest temporal separations tested (210 ms). These results demonstrate that dots arranged parallel to the signal trajectory are more easily detected than those arranged perpendicularly. Moreover, this enhancement points to the existence of visual mechanisms that preferentially organize motion information parallel to the direction of motion.

Non-NASA Center↗

Quantum Enhanced Probes of Magnetic Circular Dichroism

Magneto-optical microscopies, including optical measurements of magnetic circular dichroism, are increasingly ubiquitous tools for probing spin-orbit coupling, charge-carrier g-factors, and chiral excitations in matter, but the minimum detectable signal in classical magnetic circular dichroism measurements is fundamentally limited by the shot-noise limit of the optical readout field. Here, a two-mode squeezed light source is used to improve the minimum detectable signal in magnetic circular dichroism measurements by 3 decibels compared with state-of-the-art classical measurements, even with relatively lossy samples like terbium gallium garnet. Furthermore, these results provide a framework for new quantum-enhanced magneto-optical microscopies that are particularly critical for environmentally sensitive materials and for low temperature measurements where increased optical power can introduce unacceptable thermal perturbations.

42 ENGINEERING↗

Signal processing in SETI

It is believed that the Galaxy might contain ten billion potential life sites. In view of the physical inaccessibility of extraterrestrial life on account of the vast distances involved, a logical first step in a search for extraterrestrial intelligence (SETI) appears to be an attempt to detect signals already being radiated. The characteristics of the signals to be expected are discussed together with the search strategy of a NASA program. It is pointed out that all presently planned searches will use existing radio-astronomy antennas. If no extraterrestrial intelligence signals are discovered, society will have to decide whether SETI justifies a dedicated facility of much greater collecting area. Attention is given to a multichannel spectrum analyzer, CW signal detection, pulse detection, the pattern detector, and details of SETI system operation.

Cullers, D. K.↗

Eye-tracking of nodule detection in lung CT volumetric data

Purpose: Signal detection on 3D medical images depends on many factors, such as foveal and peripheral vision, the type of signal, and background complexity, and the speed at which the frames are displayed. In this paper, the authors focus on the speed with which radiologists and naïve observers search through medical images. Prior to the study, the authors asked the radiologists to estimate the speed at which they scrolled through CT sets. They gave a subjective estimate of 5 frames per second (fps). The aim of this paper is to measure and analyze the speed with which humans scroll through image stacks, showing a method to visually display the behavior of observers as the search is made as well as measuring the accuracy of the decisions. This information will be useful in the development of model observers, mathematical algorithms that can be used to evaluate diagnostic imaging systems. Methods: The authors performed a series of 3D 4-alternative forced-choice lung nodule detection tasks on volumetric stacks of chest CT images iteratively reconstructed in lung algorithm. The strategy used by three radiologists and three naïve observers was assessed using an eye-tracker in order to establish where their gaze was fixed during the experiment and to verify that when a decision was made, a correct answer was not due only to chance. In a first set of experiments, the observers were restricted to read the images at three fixed speeds of image scrolling and were allowed to see each alternative once. In the second set of experiments, the subjects were allowed to scroll through the image stacks at will with no time or gaze limits. In both static-speed and free-scrolling conditions, the four image stacks were displayed simultaneously. All trials were shown at two different image contrasts. Results: The authors were able to determine a histogram of scrolling speeds in frames per second. The scrolling speed of the naïve observers and the radiologists at the moment the signal was detected was measured at 25–30 fps. For the task chosen, the performance of the observers was not affected by the contrast or experience of the observer. However, the naïve observers exhibited a different pattern of scrolling than the radiologists, which included a tendency toward higher number of direction changes and number of slices viewed. Conclusions: The authors have determined a distribution of speeds for volumetric detection tasks. The speed at detection was higher than that subjectively estimated by the radiologists before the experiment. The speed information that was measured will be useful in the development of 3D model observers, especially anthropomorphic model observers which try to mimic human behavior.

60 APPLIED LIFE SCIENCES↗

Analysis of Technology for Compact Coherent Lidar

In view of the recent advances in the area of solid state and semiconductor lasers has created new possibilities for the development of compact and reliable coherent lidars for a wide range of applications. These applications include: Automated Rendezvous and Capture, wind shear and clear air turbulence detection, aircraft wake vortex detection, and automobile collision avoidance. The work performed by the UAH personnel under this Delivery Order, concentrated on design and analyses of a compact coherent lidar system capable of measuring range and velocity of hard targets, and providing air mass velocity data. The following is the scope of this work. a. Investigate various laser sources and optical signal detection configurations in support of a compact and lightweight coherent laser radar to be developed for precision range and velocity measurements of hard and fuzzy targets. Through interaction with MSFC engineers, the most suitable laser source and signal detection technique that can provide a reliable compact and lightweight laser radar design will be selected. b. Analyze and specify the coherent laser radar system configuration and assist with its optical and electronic design efforts. Develop a system design including its optical layout design. Specify all optical components and provide the general requirements of the electronic subsystems including laser beam modulator and demodulator drivers, detector electronic interface, and the signal processor. c. Perform a thorough performance analysis to predict the system measurement range and accuracy. This analysis will utilize various coherent laser radar sensitivity formulations and different target models.

Amzajerdian, Farzin↗

Detection of signals in the ion cyclotron frequency range at the edge during ICRF heating on ASDEX Upgrade

The ICRF system on ASDEX Upgrade is equipped with an arc detector based on the observation of frequencies between 5 and 25 MHz in the RF feeding line [R1]. On some shots, the detector was triggered in an anomalous way: tenths of detections over several hundreds of milliseconds on detectors of all antennas at the same time [R2]. It was suggested that these frequencies were not excited by arcs but came from the plasma. We installed a RF probe inside the vacuum vessel and connected it to a fast acquisition system. We indeed observed frequencies during ICRF heating of several shots. We present here the features of these frequencies, their possible conditions of existence in terms of plasma and RF parameters (magnetic field, density, temperature, RF frequency, power injected) and we compare the source of these frequencies with known phenomena like ICE, CAE and surface waves.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Detection and Signal Processing for Near-Field Nanoscale Fourier Transform Infrared Spectroscopy

Researchers from a broad spectrum of scientific and engineering disciplines are increasingly using scattering-type near-field infrared spectroscopic techniques to characterize materials non-destructively with nanoscale spatial resolution. However, a sub-optimal understanding of a technique's implementation can complicate data interpretation and act as a barrier to entering the field. Here the key detection and processing steps involved in producing scattering-type near-field nanoscale Fourier transform infrared spectra (nano-FTIR) are outlined. The self-contained mathematical and experimental work derives and explains: i) how normalized complex-valued nano-FTIR spectra are generated, ii) why the real and imaginary components of spectra qualitatively relate to dispersion and absorption respectively, iii) a new and generally valid equation for spectra which can be used as a springboard for additional modeling of the scattering processes, and iv) an algebraic expression that can be used to extract an approximation to the sample's local extinction coefficient from nano-FTIR. The algebraic model for weak oscillators is validated with nano-FTIR and attenuated total reflectance Fourier transform infrared (ATR-FTIR) spectra on samples of polystyrene and Kapton and further provides a pedagogical pathway to cementing some of the technique's key qualitative attributes.

36 MATERIALS SCIENCE↗

Transiting Planet Search in the Kepler Pipeline

The Kepler Mission simultaneously measures the brightness of more than 160,000 stars every 29.4 minutes over a 3.5-year mission to search for transiting planets. Detecting transits is a signal-detection problem where the signal of interest is a periodic pulse train and the predominant noise source is non-white, non-stationary (1/f) type process of stellar variability. Many stars also exhibit coherent or quasi-coherent oscillations. The detection algorithm first identifies and removes strong oscillations followed by an adaptive, wavelet-based matched filter. We discuss how we obtain super-resolution detection statistics and the effectiveness of the algorithm for Kepler flight data.

Jenkins, Jon M.↗

Wnt7a interaction with Fzd5 and detection of signaling activation using a split eGFP

Wnts are secreted glycoproteins that regulate important cellular processes including proliferation, differentiation, and cell fate. In the {beta}-catenin/canonical pathway, Wnt interacts with Fzd receptors to inhibit degradation of {beta}-catenin and promote its translocation into the nucleus where it regulates transcription of a number of genes. Dysregulation of this pathway has been attributed to a host of diseases including cancer. As a result, components of the {beta}-catenin/canonical pathway have been gaining recognition as promising targets for the discovery of novel therapeutic agents. Here, we show, using an ELISA-based protein-protein binding assay that purified Wnt7a binds to the extracellular cysteine-rich domain of Fzd5 in the nanomolar range. We have developed a novel split eGFP complementation assay to visually detect Wnt7a-Fzd5 interactions and subsequent pathway activation in cells. These biological tools could help lead to a better understanding of Wnt-Fzd interactions and the identification of new modulators of Wnt signaling.

60 APPLIED LIFE SCIENCES↗

High-sensitive scanning laser magneto-optical imaging system

A high-sensitive scanning laser magneto-optical (MO) imaging system has been developed. The system is mainly composed of a laser source, galvano meters, and a high-sensitive differential optical-detector. Preliminary evaluation of system performance by using a Faraday indicator with a Faraday rotation coefficient of 3.47x10{sup -5} rad/{mu}m Oe shows a magnetic sensitivity of about 5 {mu}T, without any need for accumulation or averaging processing. Using the developed MO system we have succeeded in the fast and quantitative imaging of a rotationally symmetric magnetic field distribution around an YBa{sub 2}Cu{sub 3}O{sub 7-{delta}} (YBCO) strip line applied with dc-biased current, and also succeeded in the detection of quantized fine signals corresponding to magnetic flux quantum generation in a superconducting loop of an YBCO Josephson vortex flow transistor. Thus, the developed system enables us not only to do fast imaging and local signal detection but also to directly evaluate both the strength and direction of a magnetic signal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A multinomial maximum likelihood program /MUNOML/

A multinomial maximum likelihood program (MUNOML) for signal detection and for behavior models is discussed. It is found to be useful in day to day operation since it provides maximum flexibility with minimum duplicated effort. It has excellent convergence qualities and rarely goes beyond 10 iterations. A library of subroutines is being collected for use with MUNOML, including subroutines for a successive categories model and for signal detectability models.

Curry, R. E.↗

Origin of electrical signals for plasma etching endpoint detection

Electrical signals are used for endpoint detection in plasma etching, but the origin of the electrical changes observed at endpoint is not known. They may be caused by changes in the gas-phase densities of etch products and reactants or by changes in substrate surface properties such as photoemitted or ion-induced electron yield. To investigate these effects, experiments were performed in an inductively coupled, rf-biased reactor, during CF{sub 4}/Ar etches of SiO{sub 2} films on Si wafers. The rf bias impedance was measured vs. time during etching, simultaneous with Langmuir probe measurements. At endpoint, a decrease in impedance coincided with increases in ion current and electron energy. The data, analyzed by a numerical model of the discharge, indicate that changes in electron emission yield were relatively insignificant or entirely absent. Thus the impedance change is not a surface effect but is, instead, predominantly or entirely a gas-phase phenomenon.

36 MATERIALS SCIENCE↗

Experimental evaluation of fluctuating density and radiated noise from a high temperature jet

An experimental investigation has been conducted to characterize the fluctuating density within a high-temperature (1100 K) subsonic jet and to characterize by the noise radiated to the surroundings. Cross correlations obtained by introducing time delay to the signals detected from spatially separated crossed laser beams set up as a Schlieren system were used to determine radial and axial distributions of the convection velocity of the moving noise sources (eddies). In addition, the autocorrelation of the fluctuating density was evaluated in the moving frame of reference of the eddies. Also, the autocorrelation of the radiated noise in the moving reference frame was evaluated from cross correlations by introducing time delay to the signals detected by spatially separated pairs of microphones. Radial distributions of the mean velocity were obtained from measurements of the stagnation temperature, and stagnation and static pressures with the use of probes.

Massier, P. F.↗

Experimental evaluation of fluctuating density and radiated noise from a high-temperature jet

An experimental investigation has been conducted to characterize the fluctuating density within a high temperature (1100 K) subsonic jet and to characterize the noise radiated to the surroundings. Cross correlations obtained by introducing time delay to the signals detected from spatially separated crossed laser beams set up as a schlieren system were used to determine radial and axial distributions of the convection velocity of the moving noise sources (eddies). In addition, the autocorrelation of the fluctuating density was evaluated in the moving frame of reference of the eddies. Also, the autocorrelation of the radiated noise in the moving reference frame was evaluated from cross correlations by introducing time delay to the signals detected by spatially separated pairs of microphones. The radiated noise results are compared with Lighthill's theory and with the data of Lush. Radial distributions of the mean velocity were obtained from measurements of the stagnation temperature, and stagnation and static pressures with the use of probes.

Massier, P. F.↗

Some More Sensitive Measures of Sensitivity and Response Bias

In this article, the author proposes a new pair of sensitivity and response bias indices and compares them to other measures currently available, including d' and Beta of signal detection theory. Unlike d' and Beta, these new performance measures do not depend on specific distributional assumptions or assumptions about the transformation from stimulus information to a discrimination judgment with simulated and empirical data, the new sensitivity index is shown to be more accurate than d' and 16 other indices when these measures are used to compare the sensitivity levels of 2 experimental conditions. Results from a perceptual discrimination experiment demonstrate the feasibility of the new distribution-free bias index and suggest that biases of the type defined within the signal detection theory framework (i.e., the placement of a decision criterion) do not exist, even under an asymmetric payoff manipulation.

Balakrishnan, J. D.↗

Advanced Water Vapor Lidar Detection System

In the present water vapor lidar system, the detected signal is sent over long cables to a waveform digitizer in a CAMAC crate. This has the disadvantage of transmitting analog signals for a relatively long distance, which is subjected to pickup noise, leading to a decrease in the signal to noise ratio. Generally, errors in the measurement of water vapor with the DIAL method arise from both random and systematic sources. Systematic errors in DIAL measurements are caused by both atmospheric and instrumentation effects. The selection of the on-line alexandrite laser with a narrow linewidth, suitable intensity and high spectral purity, and its operation at the center of the water vapor lines, ensures minimum influence in the DIAL measurement that are caused by the laser spectral distribution and avoid system overloads. Random errors are caused by noise in the detected signal. Variability of the photon statistics in the lidar return signal, noise resulting from detector dark current, and noise in the background signal are the main sources of random error. This type of error can be minimized by maximizing the signal to noise ratio. The increase in the signal to noise ratio can be achieved by several ways. One way is to increase the laser pulse energy, by increasing its amplitude or the pulse repetition rate. Another way, is to use a detector system with higher quantum efficiency and lower noise, on the other hand, the selection of a narrow band optical filter that rejects most of the day background light and retains high optical efficiency is an important issue. Following acquisition of the lidar data, we minimize random errors in the DIAL measurement by averaging the data, but this will result in the reduction of the vertical and horizontal resolutions. Thus, a trade off is necessary to achieve a balance between the spatial resolution and the measurement precision. Therefore, the main goal of this research effort is to increase the signal to noise ratio by a factor of 10 over the current system, using a newly evaluated, very low noise avalanche photo diode detector and constructing a 10 MHz waveform digitizer which will replace the current CAMAC system.

Elsayed-Ali, Hani↗

A portalino to the dark sector

“Portal” models that connect the Standard Model to a Dark Sector allow for a wide variety of scenarios beyond the simplest WIMP models. Kinetic mixing of gauge fields in particular has allowed a broad range of new ideas. However, the models that evade CMB constraints are often non-generic, with new mass scales and operators to split states and suppress indirect detection signals. Models with a “portalino”, a neutral fermion that marries a linear combination of a standard model neutrino and dark sector fermion and carries a conserved quantum number, can be simpler. This is especially interesting for interacting dark sectors; then the unmarried linear combination which we identify as the standard model neutrino inherits these interactions too, and provides a new, effective interaction between the dark sector and the standard model. These interactions can be simple Z' type interactions or lepton-flavor changing. Dark matter freezes out into neutrinos, thereby evading CMB constraints, and conventional direct detection signals are largely absent. The model offers different signals, however. The “portalino” mechanism itself predicts small corrections to the standard model neutrino couplings as well as the possibility of discovering the portalino particle in collider experiments. Possible cosmological and astroparticle signatures include monochromatic neutrino signals from annihilation, spectral features in high energy CR neutrinos as well as conventional signals of additional light species and dark matter interactions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Sensitivity and Bias in Searches of Cockpit Display of Traffic Information Utilizing Highlighting/Lowlighting

A previous investigation showed that when bright and dim traffic symbols were mixed together on a cockpit display of traffic information, dim targets required longer search times than bright targets. The current experiment utilized Signal Detection methodology to determine the cause of this effect. Two factors were manipulated, Intensity and Mixture. The Intensity manipulation varied whether targets were bright or dim. The Mixture manipulation varied whether the brightness of all aircraft symbols was the same, or if half were bright and half dim. Participants were given 1.25 s to search a display of eight aircraft and determine whether a target was present or absent (50% of the time a target was present) and then rated their confidence in the accuracy of their decision. A Mixture by Intensity repeated-measures ANOVA on the signal detectability measure, A (a non- parametric variant of d ), revealed that targets presented at the dim intensity in the mixed condition yielded significantly lower sensitivity than either of the pure (homogenous) conditions or the bright targets in the mixed condition. There was not a significant difference in False Alarm rates between any conditions, indicating no change in decision criterion. Findings are discussed in terms of possible masking effects evoked by bright aircraft over the dim aircraft. Funding for this work was provided by the Advanced Air Transportation Technologies Project of NASA s Airspace Operation Systems Program.

Johnson, Walter W.↗