Search NASA⌕ Search

SEARCH · Search NASA

Results for “Silicon detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Characterizing x-ray transmission through filters used in high energy density physics diagnostics

We report on the design and implementation of a new system used to characterize the energy-dependent x-ray transmission curve, Θ(E), through filters used in high-energy density physics diagnostics. Using an Amptek X-123-CdTe x-ray spectrometer together with a partially depleted silicon surface barrier detector, both the energy spectrum and total emission of an x-ray source have been accurately measured. By coupling these detectors with a custom PROTO-XRD x-ray source with interchangeable cathodes, accurate characterizations of Θ(E) for filters of varying materials and thicknesses have been obtained. The validity of the technique has been confirmed by accurately reproducing areal densities for high-purity filters with known x-ray transmission properties. In this paper, the experimental setup is described and the results of absorption calibrations performed on a variety of different filters are presented.

Pearcy, J.↗

Neutron Calibration Studies for the SuperCDMS SNOLAB Experiment

My time at Fermilab has been dedicated to advancing the field of dark matter detection through my contributions to the SuperCDMS collaboration. The first project involved the development and testing of a delivery system for a Cf-252 neutron source to calibrate the SuperCDMS silicon and germanium detectors. Subsequently, I focused on parametrizing the detectors' instrumental response by optimizing a plastic scintillator backing array to measure the scattering angle of a collimated neutron beam. The Monte Carlo simulation I designed provided insights into the detection efficiency of the array, and the best-fit design I arrived at for the scattering counters will be implemented into the final array. Additionally, I assembled a muon detector with legacy hardware to enhance the ability of the calibration experiment to reduce dark current and false signals. As my work nears completion, I am confident that these contributions will significantly enhance the precision and reliability of the SuperCDMS experiment, pushing the boundaries of our understanding of dark matter and contributing to the broader scientific community's quest to unravel the mysteries of the universe.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Performance of novel VUV-sensitive Silicon Photo-Multipliers for nEXO

Liquid xenon time projection chambers are promising detectors to search for neutrinoless double beta decay (0νββ), due to their response uniformity, monolithic sensitive volume, scalability to large target masses, and suitability for extremely low background operations. The nEXO collaboration has designed a tonne-scale time projection chamber that aims to search for 0νββ of 136 Xe with projected half-life sensitivity of 1.35 x 10 28 yr. To reach this sensitivity, the design goal for nEXO is ≤1% energy resolution at the decay Q-value (2458.07 ± 0.31 keV). Reaching this resolution requires the efficient collection of both the ionization and scintillation produced in the detector. The nEXO design employs Silicon Photo-Multipliers (SiPMs) to detect the vacuum ultra-violet, 175 nm scintillation light of liquid xenon. This paper reports on the characterization of the newest vacuum ultra-violet sensitive Fondazione Bruno Kessler VUVHD3 SiPMs specifically designed for nEXO, as well as new measurements on new test samples of previously characterised Hamamatsu VUV4 Multi Pixel Photon Counters (MPPCs). Various SiPM and MPPC parameters, such as dark noise, gain, direct crosstalk, correlated avalanches and photon detection efficiency were measured as a function of the applied over voltage and wavelength at liquid xenon temperature (163 K). The results from this study are used to provide updated estimates of the achievable energy resolution at the decay Q-value for the nEXO design.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Low-threshold sapphire detector for rare event searches

Low mass nuclear recoil dark matter and coherent-elastic-neutrino-nucleus-scattering (CE$v$NS) searches confront similar challenges in choosing ultra-low threshold and large-mass detectors. Here, we report experimental results from a 100 g single-crystal sapphire detector design with a diameter of 76 mm and thickness of 4 mm instrumented with transition edge sensors (TES). Sapphire is a crystal of aluminum oxide (Al 2 O) and has been found to be a good candidate for light mass dark matter search experiments due to its lower atomic mass compared to other detector materials such as germanium and silicon. This new phonon-assisted sapphire detector was characterized to yield a baseline recoil energy resolution of 28.4 ± 0.4 eV. The detector is designed to be sensitive to low-energy rare interactions with an intention to investigate the low-mass region of dark matter phase-space and search for CE$v$NS at the reactor site.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Revisiting the dark matter interpretation of excess rates in semiconductors

In light of recent results from low-threshold dark matter detectors, we revisit the possibility of a common dark matter origin for multiple excesses across numerous direct detection experiments, with a focus on the excess rates in semiconductor detectors. We explore the interpretation of the low-threshold calorimetric excess rates above 40 eV in the silicon SuperCDMS Cryogenic Phonon Detector and above 100 eV in the germanium EDELWEISS Surface detector as arising from a common but unknown origin, and demonstrate a compatible fit for the observed energy spectra in both experiments, which follow a power law of index α = 3.4 3 - 0.06 + 0.11 . Despite the intriguing scaling of the normalization of these two excess rates with approximately the square of the mass number A 2 , we argue that the possibility of common origin by dark matter scattering via nuclear recoils is strongly disfavored, even allowing for exotic condensed matter effects in an as-yet unmeasured kinematic regime, due to the unphysically large dark matter velocity required to give comparable rates in the different energy ranges of the silicon and germanium excesses. We also investigate the possibility of inelastic nuclear scattering by cosmic ray neutrons, solar neutrinos, and photons as the origin, and quantitatively disfavor all three based on known fluxes of particles.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Quality assurance test of silicon photomultipliers and electronic boards for STAR event plane detector

The event plane detector (EPD), installed in the Solenoid Tracker at the Relativistic Heavy-Ion Collider located at the Brookhaven National Laboratory is a plastic scintillator-based device that measures the reaction centrality and event plane in the forward region of the relativistic heavy-ion collisions. We used silicon photomultiplier (SiPM) arrays to detect the photons produced in the scintillator via the fiber connection. Signals from the SiPM arrays were amplified by the front-end electronic (FEE) board, and sent to the analog-to-digital converter (ADC) boards for further processing via the receiver (RX) board. The full EPD system consisted of 24 super-sectors (SSs); each SS was equipped with two SiPM boards, two FEE boards and two RX boards, and they corresponded to 744 readout channels. All these boards were mass produced at the University of Science and Technology of China, with a dedicated quality assurance (QA) procedures applied to identify any problems before deployment. This article describes the details of the QA method and the related test system. As a result, the QA test results are presented along with the discussions.

EPD↗

Evaluation of silicon and indium gallium arsenide photodiodes as direct timing detectors for pulsed x-ray systems

Benchtop pulsed x-ray systems are commonly used to record dynamic material data on the order of nanoseconds, but pulse timing is often difficult to accurately determine. This study demonstrates that commercially available photodiodes can be used effectively for direct x-ray pulse detection without the need for visible light scintillators. X-ray pulses from four commercially available flash x-ray systems were quantified using one silicon and two indium gallium arsenide (InGaAs) photodiodes. The measured InGaAs pulse durations were strongly dependent on radiation dose in the non-linear operating regime, so the photodiodes were shielded to operate below the 2.5 V non-linear regime threshold. The average pulse duration and pulse arrival time jitter of the photodiodes for each x-ray source were within several nanoseconds with the exception of two sets of measurements that were affected by low instrument sensitivity and electrical noise. These results show that InGaAs photodiodes can be used as effective and repeatable stand-alone timing diagnostics for x-ray pulses as short as 20 ns or less.

47 OTHER INSTRUMENTATION↗

Water-based Liquid Scintillator detector as a new technology testbed for neutrino studies in Turkey

This study investigates the deployment of a medium-scale neutrino detector near Turkey's rst nuclear power plant, the Akkuyu Nuclear Power Plant. The aim of this detector is to become a modular testbed for new technologies in the elds of new detection media and innovative photosensors. Such technologies include Water-based Liquid Scintillator (WbLS), Large Area Picosecond Photo- Detectors (LAPPDs), dichroic Winston cones, and large area silicon photomul- tiplier modules. Here, the detector could be used for instantaneous monitoring of the Akkuyu Nuclear Power Plant via its antineutrino ux. In addition to its physics and technological goals, it would be an invaluable opportunity for the nuclear and particle physics community in Turkey to play a role in the development of next generation of particle detectors in the eld of neutrino physics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Alignment of the CLAS12 central hybrid tracker with a Kalman Filter

Several factors can contribute to the difficulty of aligning the sensors of tracking detectors, including a large number of modules, multiple types of detector technologies, and non-linear strip patterns on the sensors. All three of these factors apply to the CLAS12 CVT, which is a hybrid detector consisting of planar silicon sensors with non-parallel strips, and cylindrical micromegas sensors with longitudinal and arc-shaped strips located within a 5 T superconducting solenoid. To align this detector, we used the Kalman Alignment Algorithm, which accounts for correlations between the alignment parameters without requiring the time-consuming inversion of large matrices. This is the first time that this algorithm has been adapted for use with hybrid technologies, non-parallel strips, and curved sensors. We present the results for the first alignment of the CLAS12 CVT using straight tracks from cosmic rays and from a target with the magnetic field turned off. After running this procedure, we achieved alignment at the level of 10 µm, and the widths of the residual spectra were greatly reduced. These results attest to the flexibility of this algorithm and its applicability to future use in the CLAS12 CVT and other hybrid or curved trackers, such as those proposed for the future Electron-Ion Collider.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of energy resolution with the NEXT-White silicon photomultipliers

The NEXT-White detector, a high-pressure gaseous xenon time projection chamber, demonstrated the excellence of this technology for future neutrinoless double beta decay searches using photomultiplier tubes (PMTs) to measure energy and silicon photomultipliers (SiPMs) to extract topology information. This analysis uses $^{83m}$Kr data from the NEXT-White detector to measure and understand the energy resolution that can be obtained with the SiPMs, rather than with PMTs. The energy resolution obtained of (10.9 ± 0.6)%, full-width half-maximum, is slightly larger than predicted based on the photon statistics resulting from very low light detection coverage of the SiPM plane in the NEXT-White detector. The difference in the predicted and measured resolution is attributed to poor corrections, which are expected to be improved with larger statistics. Furthermore, the noise of the SiPMs is shown to not be a dominant factor in the energy resolution and may be negligible when noise subtraction is applied appropriately, for high-energy events or larger SiPM coverage detectors. These results, which are extrapolated to estimate the response of large coverage SiPM planes, are promising for the development of future, SiPM-only, readout planes that can offer imaging and achieve similar energy resolution to that previously demonstrated with PMTs.[graphic not available: see fulltext]

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Silicon pinhole strip defects and their impact on ATLAS Inner Tracker HV current measurement

In preparation for the High-Luminsity LHC (HL-LHC) [1], the ATLAS detector will undergo major detector upgrades, including the replacement of the current Inner Detector with the new all-silicon Inner Tracker (ITk) [2]. The ITk consists of a pixel detector close to the beamline surrounded by a large-area strip detector. During detector production, the electrical properties of silicon sensors and readout electronics must be characterized through a series of quality control (QC) and quality assurance tests. These tests ensure any defect is captured at the earliest possible stage. One such defect, callled a pinhole, occurs when the strip implant and the metal readout electrode are shorted through the intermediary dielectric layer. Notably, the introduction of pinholes during module assembly and pinhole effects on completed modules, especially on leakage current measurement circuitry, have never been studied. In this paper, we investigate the effect of such connections on the sensor leakage current measurements of completed modules and introduce new ways to locate pinholed strips. Here, with minor modifications to testing procedures, such defects are shown not to impede module testing or performance.

FOS: Physical sciences↗

The MU2E Experiment at FERMILAB: R&D, Design and Status

The Mu2e Experiment at Fermilab 1) will search for coherent, neutrinoless conversion of negative muons into electrons in the field of an aluminum nucleus, µ - + N (A, Z) → e - + N (A, Z). This is an example of Charged Lepton Flavour Violation (CLFV) never observed experimentally. The dynamics of such a process is well modelled by a two-body decay, resulting in a mono-energetic electron with an energy slightly below the muon rest mass (~104.967 MeV). If no events are observed in three years of running, Mu2e will set an upper limit on the ratio between conversion and capture rate R µe ≤ 6 × 10 -17 (@ 90% C.L.). This will improve the current limit of a factor of 10 4 over previous experiments. The experiment complements and extends the current/planned searches (µ → eγdecay at MEG , mu3e) as well as the direct searches for new physics at the LHC. Indeed, such CLFV searches in the muon sector probe new physics at a mass scale inaccessible with direct searches at either present or planned high-energy colliders. To detect the muon conversion process, a very intense pulsed beam of negative muons is produced by means of a S-shape Superconducting Solenoid Magnet System that is organized into three subsystems: the Production Solenoid, the Transport Solenoid and the Detector Solenoid. The beam is stopped at 10 GHz on an Aluminum target inside the Detector Solenoid. The Mu2e detectors, also installed inside the Detector Solenoid, are a high-precision tracker made on ~20000 straw tubes, and a calorimeter composed of ~1500 pure CsI crystals organized in two disks and readout by two large area UV-extended Silicon Photomultipliers (SiPMs). The Detector Solenoid region is surrounded by a Cosmic Ray Veto based on scintillators readout by SiPMs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A high-temperature Rutherford Backscattering Spectrometry apparatus for in situ material characterization

A new methodology for high-temperature Rutherford Backscattering Spectrometry (HT-RBS) has been developed to enable in situ material characterization at elevated temperatures. A 3.5 MeV proton beam penetrates a 10-µm-thick 316L stainless steel foil mounted on a graphite substrate, with backscattered signals detected using an HT-RBS system. Conventional semiconductor detectors, primarily based on silicon, suffer significant performance degradation at temperatures higher than ~ 60 °C due to increased leakage current and noise, leading to signal distortion and failure. Here, to preserve spectral quality, a 5 µm aluminum foil shields the detector from thermal radiation, allowing reliable operation up to 900 °C at the target. A rotatable shutter provides additional thermal isolation during data collection pauses. In situ measurements of areal density changes of 316L stainless steel were conducted to validate the technique, revealing consistency with the known thermal expansion coefficient. The method facilitates seamless switching between irradiation and analysis, enabling continuous studies. This approach supports in situ investigations of diffusion, void swelling, creep, and corrosion, offering a versatile tool for advanced materials research.

36 MATERIALS SCIENCE↗

The BDX-MINI detector for Light Dark Matter search at JLab

This paper describes the design and performance of a compact detector, BDX-MINI, that incorporates all features of a concept that optimized the detection of light dark matter in the MeV-GeV mass range produced by electrons in a beam dump. It represents a reduced version of the future BDX experiment expected to run at JLAB. BDX-MINI was exposed to penetrating particles produced by a 2.176GeV electron beam incident on the beam dump of Hall A at Jefferson Lab. The detector consists of 30.5 kg of PbWO 4 crystals with sufficient material following the beam dump to eliminate all known particles except neutrinos. The crystals are read out using silicon photomultipliers. Completely surrounding the detector are a passive layer of tungsten and two active scintillator veto systems, which are also read out using silicon photomultipliers. The design was validated and the performance of the robust detector was shown to be stable during a six month period during which the detector was operated with minimal access.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Low voltage AC electroluminescence in silicon MOS capacitors

Low power silicon based light source and detector are attractive for on-chip photonic circuits given their ease of process integration. However, conventional silicon light emitting diodes emit photons with energies near the band edge where the corresponding silicon photodetectors lack responsivity. On the other hand, previously reported hot carrier electroluminescent silicon devices utilizing a reverse biased diode require high operating voltages. Here, we investigate hot carrier electroluminescence in silicon metal–oxide–semiconductor capacitors operating under transient voltage conditions. Further, during each voltage transient, large energy band bending is created at the edge of the source contact, much larger than what is achievable at a steady state. As a result, electrons and holes are injected efficiently from a single source contact into the silicon channel at the corresponding voltage transient, where they subsequently undergo impact ionization and phonon-assisted interband recombination. Notably, we show low voltage operation down to 2.8 V by using a 20 nm thick high-κ gate dielectric. We show further voltage scaling is possible by reducing the gate dielectric thickness, thus presenting a low voltage platform for silicon optoelectronic integrated circuits.

42 ENGINEERING↗

The NEXT-100 Detector

The NEXT collaboration is dedicated to the study of double beta decays of 136 Xe using a high-pressure gas electroluminescent time projection chamber. This advanced technology combines exceptional energy resolution (≤ 1% FWHM at the Q ββ value of the neutrinoless double beta decay) and powerful topological event discrimination. Building on the achievements of the NEXT-White detector, the NEXT-100 detector started taking data at the Laboratorio Subterráneo de Canfranc (LSC) in May of 2024. Designed to operate with xenon gas at 13.5 bar, NEXT-100 consists of a time projection chamber where the energy and the spatial pattern of the ionising particles in the detector are precisely retrieved using two sensor planes (one with photo-multiplier tubes and the other with silicon photo-multipliers). The detector has been operating at stable conditions using argon and xenon gases at ~4 bar and drift fields of 74 V cm –1 and 118 V cm –1 , respectively. Alpha decays from the 222 Rn chain have been used to test and monitor the stability of the detector, showing a constant electron lifetime in the drift volume. In this paper, in addition to reporting the results of the commissioning run, we provide a detailed description of the NEXT-100 detector, describe its assembly, and present the current estimation of the radiopurity budget.

Adams, C. [Argonne National Laboratory; NVIDIA] (O↗

Inert Gas Element as Active Infrared‐Absorption Source and Donor in Silicon for Forbidden‐Wavelength Sensing

Intrinsic silicon (Si) is forbidden for infrared (IR) sensing at the communication wavelength like 1.31 or 1.55 µm due to the well‐known bandgap limitation. In this work, an unexpected physical picture of using argon (Ar) is identified, which is usually inert to the surrounding chemical environment and used as a protective agent in semiconductor processing, to overcome the IR‐sensing‐forbidden problem in Si. Here, in this work, it is shown by an analysis of a dynamic secondary ion mass spectrometer that such a Si, when exposed to laser pulse in Ar gas, can contain a very high dose of Ar up to 10 20 cm −3 even after 1300 days. First‐principles calculations, molecular dynamics, and Hall effect measurements reveal that, due to both steric and dynamic repulsions by Ar orbitals to Si dangling bonds, the Ar‐filled‐vacancy produces a much wider defect band inside the gap, which is not only responsible for strong infrared absorption, but also causes a significant increase in n‐type conductivity, both in line with experiments. The study proves that originally inert elements in fact can act as active impurities in semiconductors for advanced applications, which updates the current knowledge of defect physics.

36 MATERIALS SCIENCE↗

Study of CMOS strip sensor for future silicon tracker

Monolithic silicon sensors developed with High-Voltage CMOS (HV-CMOS) processes have become highly attractive for charged particle tracking. Compared with the standard CMOS sensors, HV-CMOS sensors can provide larger and deeper depletion regions that lead to larger signals and faster charge collection. They can provide high position resolution, low material budget, high radiation hardness and low cost that are desirable for high performance tracking in harsh collision environment. Various studies have been conducted to explore the technology feasibility for the large-area tracking systems at future collider experiments. CHESS (CMOS HV/HR Evaluation for Strip Sensor) sensor series have been developed as an alternative solution to the conventional silicon micro-strip detectors for the ATLAS inner tracker upgrade. The first prototype (named CHESS1) was to evaluate the diode geometry and the in-pixel analog electronics. Obtained test results were used to optimize the second prototype (named CHESS2). CHESS2 was implemented with a full digital readout architecture and realized as a full reticle sized monolithic sensor. Here, the basic characteristics of the CHESS2 prototype sensors and their performance in response to different input signals are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗