Search NASA⌕ Search

SEARCH · Search NASA

Results for “Single photon sources”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Merged-Element Transmon

Transmon qubits are ubiquitous in the pursuit of quantum computing using superconducting circuits. However, they have some drawbacks that still need to be addressed. Most importantly, the scalability of transmons is limited by the large device footprint needed to reduce the participation of the lossy capacitive parts of the circuit. In this work, we investigate and evaluate losses in an alternative device geometry, namely, the merged-element transmon (mergemon). To this end, we replace the large external shunt capacitor of a traditional transmon with the intrinsic capacitance of a Josephson junction and achieve an approximately 100 times reduction in qubit dimensions. We report the implementation of the mergemon using a sputtered Nb–amorphous-Si–Nb trilayer film. In an experiment below 10 mK, the frequency of the readout resonator, capacitively coupled to the mergemon, exhibits a qubit-state-dependent shift in the low-power regime. The device also demonstrates the single-photon and multiphoton transitions that represent a weakly anharmonic system in two-tone spectroscopy. The transition spectra are explained well with master-equation simulations. Here, a participation-ratio analysis identifies the dielectric loss of the amorphous-Si tunnel barrier and its interfaces as the dominant source for qubit relaxation. We expect the mergemon to achieve high coherence for relatively small device dimensions when implemented with a low-loss, epitaxially grown, and lattice-matched trilayer.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Quantum Enhanced Dark-Matter Search with Entangled Fock States in High-Quality Cavities

We present a quantum-enhanced protocol for detecting wave-like dark matter using an array of $N$ entangled superconducting cavities initialized in an $m$-photon Fock state. By distributing and recollecting the quantum state with an entanglement-distribution operation, the scan rate scales as $N^2(m+1)$ while thermal excitation is the dominant background, significantly outperforming classical single-cavity methods under matched conditions. We evaluate the robustness of our scheme against additional noise sources, including decoherence and beamsplitter infidelity, through theoretical analysis and numerical simulations. In practice, the key requirements, namely high-Q superconducting radio-frequency cavities that support long integration times, high-fidelity microwave beamsplitters, and universal cavity control, are already available on current experimental platforms, making the protocol experimentally feasible.

Freiman, Benjamin [Fermilab]↗

Extreme ultraviolet time- and angle-resolved photoemission setup with 21.5 meV resolution using high-order harmonic generation from a turn-key Yb:KGW amplifier

Characterizing and controlling electronic properties of quantum materials require direct measurements of nonequilibrium electronic band structures over large regions of momentum space. Here, we demonstrate an experimental apparatus for time- and angle-resolved photoemission spectroscopy using high-order harmonic probe pulses generated by a robust, moderately high power (20 W) Yb:KGW amplifier with a tunable repetition rate between 50 and 150 kHz. By driving high-order harmonic generation (HHG) with the second harmonic of the fundamental 1025 nm laser pulses, we show that single-harmonic probe pulses at 21.8 eV photon energy can be effectively isolated without the use of a monochromator. The on-target photon flux can reach 5 × 1010 photons/s at 50 kHz, and the time resolution is measured to be 320 fs. The relatively long pulse duration of the Yb-driven HHG source allows us to reach an excellent energy resolution of 21.5 meV, which is achieved by suppressing the space-charge broadening using a low photon flux of 1.5 × 108 photons/s at a higher repetition rate of 150 kHz. The capabilities of the setup are demonstrated through measurements in the topological semimetal ZrSiS and the topological insulator Sb2−xGdxTe3.

Liu, Yangyang↗

Quantifying high-dimensional spatial entanglement with a single-photon-sensitive time-stamping camera

High-dimensional entanglement is a promising resource for quantum technologies. Being able to certify it for any quantum state is essential. However, to date, experimental entanglement certification methods are imperfect and leave some loopholes open. Using a single-photon-sensitive time-stamping camera, we quantify high-dimensional spatial entanglement by collecting all output modes and without background subtraction, two critical steps on the route toward assumptions-free entanglement certification. We show position-momentum Einstein–Podolsky–Rosen (EPR) correlations and quantify the entanglement of formation of our source to be larger than 2.8 along both transverse spatial axes, indicating a dimension higher than 14. Our work overcomes important challenges in photonic entanglement quantification and paves the way toward the development of practical quantum information processing protocols based on high-dimensional entanglement.

79 ASTRONOMY AND ASTROPHYSICS↗

Counting of Hong-Ou-Mandel Bunched Optical Photons Using a Fast Pixel Camera

The uses of a silicon-pixel camera with very good time resolution (∼nanosecond) for detecting multiple, bunched optical photons is explored. We present characteristics of the camera and describe experiments proving its counting capabilities. We use a spontaneous parametric down-conversion source to generate correlated photon pairs, and exploit the Hong-Ou-Mandel (HOM) interference effect in a fiber-coupled beam splitter to bunch the pair onto the same output fiber. It is shown that the time and spatial resolution of the camera enables independent detection of two photons emerging simultaneously from a single spatial mode.

47 OTHER INSTRUMENTATION↗

Structural, Criticality, and Radiation Dose Calculations to Support SNF Loading into a DOE Standard Canister

The DOE Standard Canister Demonstration Project includes the development of an internal support structure (ISS) for the 4.6-m-long and 45.7-cm-diameter canister. This study presents structural evaluations, criticality safety assessments, and dose rate calculations conducted within the scope of the ISS design process to support smooth canister loading operations and to ensure safe storage, transportation, and disposal of Peach Bottom 1 Core II (PB2) and Fort St. Vrain (FSV) SNF, currently stored at INL’s CPP-603 facility. The ISS includes a 316L stainless-steel basket that holds 12 PB2 SNF rods. The PB2 basket rests on top of six individual, 78.7-cm-long, 316L stainless-steel columns that are equally spaced and welded to the inner canister wall at the lower end of the shell. These columns represent the FSV basket and can hold one FSV SNF element. An A92014 T6 aluminum spacer disc is bolted to the bottom plate of the PB2 basket to vertically restrain the FSV SNF element after the PB2 basket is placed inside the canister above the FSV basket. The structural evaluations of the ISS followed applicable ASME BPVC.III.3 guidelines and included finite element (FE) analyses of the PB2 basket structure; analyses of welds and bolds; buckling analyses of selected components, and acceptability assessments of the expected basket deformations under loading operations. The criticality safety assessments used the Monte Carlo N-Particle (MCNP) software architecture Version 6.2, including ENDF/B-V continuous-energy cross-section libraries, considering intact SNF in a single storage overpack or two multistorage overpack configurations and intact or failed SNF configured for disposal. The dose rate computations are based on source terms taken from the DOE Spent Fuel Database. The isotopic composition was decay corrected for the year 2022 using the ORIGEN module in the SCALE suite. A 19-group photon spectrum and a 27-group neutron-source spectrum were generated and used in MCNP to calculate estimated dose-equivalent rates, both on DOE Standard Canister contact and at a radial distance of 1 m from the canister surface. The results of this study indicate a structurally sound system that can uphold its criticality safety functions throughout its intended operational phases. Furthermore, this study provides confidence that sufficient radiological protection is technically achievable.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

On-chip frequency-bin quantum photonics

Abstract Frequency-bin encoding furnishes a compelling pathway for quantum information processing systems compatible with established lightwave infrastructures based on fiber-optic transmission and wavelength-division multiplexing. Yet although significant progress has been realized in proof-of-principle tabletop demonstrations, ranging from arbitrary single-qubit gates to controllable multiphoton interference, challenges in scaling frequency-bin processors to larger systems remain. In this Perspective, we highlight recent advances at the intersection of frequency-bin encoding and integrated photonics that are fundamentally transforming the outlook for scalable frequency-based quantum information. Focusing specifically on results on sources, state manipulation, and hyperentanglement, we envision a possible future in which on-chip frequency-bin circuits fulfill critical roles in quantum information processing, particularly in communications and networking.

electro-optic modulators↗

A New MCNP6 Electron-Photon Transport Validation Test: The Lockwood Energy Deposition Experiment (V.1.0)

This memo announces the availability of a new validation test for quantifying the accuracy of the MCNP6 electron-photon transport algorithm for use in energy-deposition calculations. Specifically, energy-deposition results are compared with the Lockwood energy-deposition experiment. The comparison includes energy-deposition profiles in a variety of different single-element materials including beryllium, aluminum, carbon, copper, iron, molybdenum, tantalum, and uranium for pencil beam electron sources with energies including 0.05-, 0.1-, 0.3-, 0.5, and 1-MeV and angles of incidence including normal, 30°, and 60° off-normal. The purpose of this memo is to discuss the contents of the Lockwood validation directory and to outline the procedure for generating the input files, running the tests, processing the results, and comparing results to the experimental and numerical benchmark. Each step is mostly automated by a makefile that executes the necessary perl script.

74 ATOMIC AND MOLECULAR PHYSICS↗

A Hybrid Molecular–Nanophotonic Platform for On-Chip Cavity Quantum Electrodynamics and Collective Interactions

We present a hybrid solid-state cavity quantum electrodynamics (QED) platform that integrates a high density of coherent organic molecules with high-quality-factor nanophotonics. Thin anthracene crystals doped with dibenzoterrylene (DBT) are mechanically transferred onto prefabricated silicon nitride photonic crystal cavities, preserving both the cavity quality and molecular coherence. This approach decouples emitter synthesis from nanofabrication, providing a pathway for integrating other types of emitters. The high density of molecular emitters results in up to ten molecules being coupled to a single cavity. By tuning pairs of molecules into resonance within a single cavity mode, we observe cavity-mediated interactions in both dispersive and dissipative regimes. Furthermore, these results establish an accessible route to deterministic on-chip single- and multiphoton sources.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Cross Section Measurements of Photonuclear Reaction Pathways Towards Promising Medical Radioisotopes

Project Objectives: The goal of this project was to generate data relevant to radioisotope production while developing innovative technologies that foster and enhance novel production of radioisotopes, and, also, while providing opportunities for cultivating and training future generations of scientists. This work has provided the foundation for methodologies for determination of photonuclear cross sections over multiple energies in a single irradiation. Simultaneously, the feasibility of electron LINAC production of several in-demand radioisotopes such as 47 Sc, 67 Cu, 77 As, and 186 Re has been demonstrated. To accomplish these objectives a collaboration was formed between two complimentary facilities, the Low Energy Accelerator Facility (LEAF) at Argonne National Laboratory and the High Intensity Gamma-ray Source (HIGS) at Triangular Universities Nuclear Laboratory (TUNL). The involvement of the research group from North Carolina Central University gave students at this Historically Black University experience in forefront nuclear-physics research relevant to addressing a high-priority interdisciplinary issue. Project Description: HIGS provides a nearly monoenergetic gamma-ray beam by intra-cavity Compton backscattering of free-electron photons from electrons circulating in a storage ring. This beam can be collimated to produce a very precise energy beam. If the beam is un-collimated a calculated and precise energy spread of the beam occurs radially. The γ-flux can be evenly distributed over the radial distribution of energy and used to perform activation experiments on concentric ring targets. Thus providing multiple energy ranges in a single irradiation. Each concentric ring target can be counted separately in order to determine activation at the given energy and successively be correlated to the activation cross section. Targets were activated to determine production feasibility using electron beams at LEAF. Potential Impact: The Nuclear Science Advisory Committee recently named production of radioisotopes with electron LINACs as one of the most compelling and largest-impact opportunities for the production of high specific activity radioisotopes. Improving the photonuclear cross sectional data base with experimentally verified results will greatly enhance a researcher’s ability to rationalize electron LINAC production routes towards desired radioisotopes. This work will provide the foundation for methodologies for determination of photonuclear cross sections over multiple energies and multiple targets in a single irradiation. The techniques developed in this project will enable future studies to continue verifying theoretically predicted photonuclear cross section with experimental results. These data will also enable adaptation of models and support more precise theoretical calculation of photonuclear cross sections. This research will involve undergraduates, graduate students, and post-docs to give them a valuable research experience leading towards the next generation of scientists in the field of medical isotopes.

07 ISOTOPE AND RADIATION SOURCES↗

Scalable single-mode surface-emitting laser via open-Dirac singularities

Single-aperture cavities are a key component of lasers that are instrumental for the amplification and emission of a single light mode. However, the appearance of high-order transverse modes as the size of the cavities increases has frustrated efforts to scale-up cavities while preserving single-mode operation since the invention of the laser six decades ago. A suitable physical mechanism that allows single-mode lasing irrespective of the cavity size-a 'scale invariant' cavity or laser-has not been identified yet. Here we propose and demonstrate experimentally that open-Dirac electromagnetic cavities with linear dispersion-which in our devices are realized by a truncated photonic crystal arranged in a hexagonal pattern-exhibit unconventional scaling of losses in reciprocal space, leading to single-mode lasing that is maintained as the cavity is scaled up in size. The physical origin of this phenomenon lies in the convergence of the complex part of the free spectral range in open-Dirac cavities towards a constant governed by the loss rates of distinct Bloch bands, whereas for common cavities it converges to zero as the size grows, leading to inevitable multimode emission. An unconventional flat-envelope fundamental mode locks all unit cells in the cavity in phase, leading to single-mode lasing. We name such sources Berkeley surface-emitting lasers (BerkSELs) and demonstrate that their far-field corresponds to a topological singularity of charge two, in agreement with our theory. Open-Dirac cavities unlock avenues for light-matter interaction and cavity quantum electrodynamics.

42 ENGINEERING↗

Single-photoelectron collection efficiency in 4D ultrafast electron microscopy

In femtosecond (fs) 4D ultrafast electron microscopy (UEM), a tradeoff is made between photoelectrons per packet and time resolution. One consequence of this can be longer-than-desirable acquisition times for low-density packets, and particularly for low repetition rates when complete photothermal dissipation is required. Thus, gaining an understanding of photoelectron trajectories in the gun region is important for identifying factors that limit collection efficiency (CE; fraction of photoelectrons that enter the illumination system). Here, we continue our work on the systematic study of photoelectron trajectories in the gun region of a Thermo Fisher/FEI Tecnai Femto UEM, focusing specifically on CE in the single-electron regime. Using General Particle Tracer, calculated field maps, and the exact architecture of the Tecnai Femto UEM, we simulated the effects of fs laser parameters and key gun elements on CE. The results indicate CE strongly depends upon the laser spot size on the source, the (unbiased) Wehnelt aperture diameter, and the incident photon energy. The CE dispersion with laser spot size is found to be strongly dependent on aperture diameter, being nearly dispersionless for the largest apertures. A gun crossover is also observed, with the beam-waist position being dependent on the aperture diameter, further illustrating that the Wehnelt aperture acts as a simple, fixed electrostatic lens in UEM mode. This work provides further insights into the operational aspects of fs 4D UEM.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Two-Photon Spontaneous Emission in Atomically Thin Plasmonic Nanostructures

The ability to harness light-matter interactions at the few-photon level plays a pivotal role in quantum technologies. Single photons—the most elementary states of light—can be generated on demand in atomic and solid state emitters. Two-photon states are also key quantum assets, but achieving them in individual emitters is challenging because their generation rate is much slower than competing one-photon processes. We demonstrate that atomically thin plasmonic nanostructures can harness two-photon spontaneous emission, resulting in giant far field two-photon production, a wealth of resonant modes enabling tailored photonic and plasmonic entangled states, and plasmon-assisted single-photon creation orders of magnitude more efficient than standard one-photon emission. We unravel the two-photon spontaneous emission channels and show that their spectral line shapes emerge from an intricate interplay between Fano and Lorentzian resonances. Enhanced two-photon spontaneous emission in two-dimensional nanostructures paves the way to an alternative efficient source of light-matter entanglement for on-chip quantum information processing and free-space quantum communications.

36 MATERIALS SCIENCE↗

Structural, Criticality, and Radiation Dose Calculations to support SNF Loading into a DOE Standard Canister

The DOE Standard Canister Demonstration Project includes the development of an internal support structure (ISS) for the 4.6-m long and 45.7-cm diameter canister. This study presents structural evaluations, criticality safety assessments, and dose rate calculations conducted within the scope of the ISS design process to support smooth canister loading operations and to ensure safe storage, transportation, and disposal of Peach Bottom 1 Core II (PB2) and Fort St. Vrain (FSV) SNF, currently stored at the CPP-603 facility of the INL. The ISS includes a 316L stainless steel basket that holds twelve PB2 SNF rods. Further, six individual, 78.7-cm long, 316L stainless steel columns are equally spaced and welded to the inner canister wall at the lower end of the shell. These columns represent the FSV basket and can hold one FSV SNF element. An A92014 T6 aluminum spacer disc is bolted to the bottom plate of the PB2 basket to vertically restrain the FSV SNF element after the PB2 basket is placed inside the canister on top of the FSV basket. The structural evaluations of the ISS followed applicable ASME BPVC.III.3 guidelines and included finite element (FE) analyses of the PB2 basket structure; analyses of welds and bolds; buckling analyses of selected components, and acceptability assessments of the expected basket deformations under loading operations. The criticality safety assessments used the Monte Carlo N-Particle (MCNP) software architecture version 6.2 including ENDF/B-V continuous energy cross-section libraries, considering intact SNF in a single storage overpack or two multi-storage overpack configurations, and intact or failed SNF configured for disposal. The dose rate computations are based on source terms taken from the DOE Spent Fuel Database. The isotopic composition was decay corrected for the year 2022 using the ORIGEN module in the SCALE suite. A 19-group photon spectrum and 27-group neutron-source spectra were generated and used in MCNP to calculate estimated dose-equivalent rates, both on DOE Standard Canister contact and at a radial distance of from the canister surface. The results of this study indicate a structurally sound system that can uphold its criticality safety functions throughout its intended operational phases. Further, they increase confidence that sufficient radiological protection is technically achievable.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Performance of a phonon-mediated kinetic inductance detector at the NEXUS cryogenic facility

Microcalorimeters that leverage microwave kinetic inductance detectors to read out phonon signals in the particle-absorbing target, referred to as kinetic inductance phonon-mediated (KIPM) detectors, offer an attractive detector architecture to probe dark matter (DM) down to the fermionic thermal relic mass limit. A prototype KIPM detector featuring a single aluminum resonator patterned onto a 1-gram silicon substrate was operated in the Northwestern EXerimental Underground Site (NEXUS) low-background facility at Fermilab for characterization and evaluation of this detector architecture’s efficacy for a DM search. An energy calibration was performed by exposing the bare substrate to a pulsed source of 470-nm photons, resulting in a baseline resolution on the energy absorbed by the phonon sensor of 2.1 ± 0.2 eV, a factor of two better than the current state of the art, enabled by quasiparticle lifetimes extending up to 6.5 ms. However, due to the subpercent phonon collection efficiency, the resolution on energy deposited in the substrate is limited to σ E = 318 ± 29 eV. We further model both the signal pulse shape as a function of device temperature to extract quasiparticle lifetimes, and the observed noise spectra.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Implementation of Talbot–Lau x-ray deflectometry in the pulsed power environment using a copper X-pinch backlighter

A Talbot–Lau x-ray deflectometer can map electron density gradients in high energy density plasmas, as well as provide information about plasma elemental composition through single-image x-ray refraction and attenuation measurements. A new adaptation to a pulsed power environment used backlighting from copper X-pinches, allowing for electron density mapping of a low-Z object. Even though the X-pinch backlighter is not properly optimized for emitting x-rays in terms of source size and photon fluence, Moire fringe patterns with contrast up to 14% and fringe shift due to refraction on a beryllium object are obtained. Due to the proximity of the deflectometer with the X-pinch (~6 cm), it is shown that a protective filter is required to avoid damage in the closest (i.e., source) grating due to both plasma debris and mechanical shock. Regarding grating survival, these did not show any damage due to the intense magnetic field or heating induced by plasma radiation. Electron density on beryllium was measured with a difference lower than 16%. The areal electron density mapping of the sample was limited by source size characteristics, in similarity to transmission radiography. These results show the potential of plasma electron density as well as material mapping through Talbot–Lau x-ray deflectometry in a pulsed power environment.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Coded-mask-based wavefront sensing technique for APS nanofocusing beamline diagnostics

Here, we extend our recently developed coded-mask wavefront sensing technique to enable single-shot measurements of nanofocused x-ray beams. This method accurately reconstructs the focal beam profile by backpropagating the wavefront measured downstream of the beam focus. To validate its performance, we benchmarked it against the conventional fluorescence wire scan method, successfully measuring ∼120 nm focal spots at the 28-ID-B beamline of the Advanced Photon Source using a polymeric compound refractive lens. The results highlight the effectiveness of coded-mask wavefront sensing for high-precision beam profiling and its application as a real-time wavefront monitoring tool.

Shi, Xianbo [Argonne National Laboratory (ANL), Ar↗

The high-energy X-ray spectrum of the Crab Nebula observed from OSO-8

Results are reported for a measurement of the X-ray spectrum of the Crab Nebula over the energy range from 20 to 500 keV with a scintillation spectrometer aboard the OSO-8 satellite. A time-averaged spectrum of the nebula is presented which includes the average intensity of the X-ray pulsar NP 0532. The photon spectrum is shown to be well-fitted by a power law with a constant of approximately 4.19, a weighted mean energy of 39.1 keV, and a spectral index of about 2.00. No evidence is found for day-to-day variations in the spectrum of the source. The spectrum obtained is taken as evidence for the single power-law character of the Crab Nebula spectrum out to at least 200 keV and probably to as high an energy as 500 keV.

Dolan, J. F.↗