Search NASA⌕ Search

SEARCH · Search NASA

Results for “Soft thresholding”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Spectral softening between outburst and quiescence in the neutron star low-mass X-ray binary SAX J1750.8-2900

Tracking the spectral evolution of transiently accreting neutron stars between outburst and quiescence probes relatively poorly understood accretion regimes. Such studies are challenging because they require frequent monitoring of sources with luminosities below the thresholds of current all-sky X-ray monitors. We present the analysis of over 30 observations of the neutron star low-mass X-ray binary SAX J1750.8-2900 taken across four years with the X-ray telescope aboard Swift. We find spectral softening with decreasing luminosity both on long (∼1 yr) and short (∼days to week) timescales. As the luminosity decreases from 4 × 10{sup 36} erg s{sup −1} to ∼1×10{sup 35} erg s{sup −1} (0.5–10 keV), the power law photon index increases from 1.4 to 2.9. Although not statistically required, our spectral fits allow an additional soft component that displays a decreasing temperature as the luminosity decreases from 4 × 10{sup 36} to 6 × 10{sup 34} erg s{sup −1}. Spectral softening exhibited by SAX J1750.8-2900 is consistent both with accretion emission whose spectral shape steepens with decreasing luminosity and also with being dominated by a changing soft component, possibly associated with accretion onto the neutron star surface, as the luminosity declines.

79 ASTRONOMY AND ASTROPHYSICS↗

Unsterile-active neutrino mixing: Consequences on radiative decay and bounds from the x-ray background

We consider a sterile neutrino to be an unparticle, namely, an unsterile neutrino, with anomalous dimension {eta} and study its mixing with a canonical active neutrino via a seesaw mass matrix. We show that there is no unitary transformation that diagonalizes the mixed propagator and a field redefinition is required. The propagating or 'mass' states correspond to an unsterilelike and activelike mode. The unsterile mode features a complex pole or resonance for 0{<=}{eta}<1/3 with an 'invisible width' which is the result of the decay of the unsterile mode into the active mode and the massless particles of the hidden conformal sector. For {eta}{>=}1/3, the complex pole disappears, merging with the unparticle threshold. The active mode is described by a stable pole, but 'inherits' a nonvanishing spectral density above the unparticle threshold as a consequence of the mixing. We find that the radiative decay width of the unsterile neutrino into the active neutrino (and a photon) via charged current loops, is suppressed by a factor {approx}[2sin{sup 2}({theta}{sub 0})(M{sup 2}/{lambda}{sup 2})]{sup {eta}}{sup /(1-{eta})}, where {theta}{sub 0} is the mixing angle for {eta}=0, M is approximately the mass of the unsterile neutrino, and {lambda}>>M is the unparticle scale. The suppression of the radiative (visible) decay width of the sterile neutrino weakens the bound on the mass and mixing angle from the x-ray or soft gamma-ray background.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

An MHD model for magnetar giant flares

Giant flares on soft gamma-ray repeaters that are thought to take place on magnetars release enormous energy in a short time interval. Their power can be explained by catastrophic instabilities occurring in the magnetic field configuration and the subsequent magnetic reconnection. By analogy with the coronal mass ejection events on the Sun, we develop a theoretical model via an analytic approach for magnetar giant flares. In this model, the rotation and/or displacement of the crust causes the field to twist and deform, leading to flux rope formation in the magnetosphere and energy accumulation in the related configuration. When the energy and helicity stored in the configuration reach a threshold, the system loses its equilibrium, the flux rope is ejected outward in a catastrophic way, and magnetic reconnection helps the catastrophe develop to a plausible eruption. By taking SGR 1806–20 as an example, we calculate the free magnetic energy released in such an eruptive process and find that it is more than 10{sup 47} erg, which is enough to power a giant flare. The released free magnetic energy is converted into radiative energy, kinetic energy, and gravitational energy of the flux rope. We calculated the light curves of the eruptive processes for the giant flares of SGR 1806–20, SGR 0526–66, and SGR 1900+14, and compared them with the observational data. The calculated light curves are in good agreement with the observed light curves of giant flares.

79 ASTRONOMY AND ASTROPHYSICS↗

TU-F-BRF-06: 3D Pancreas MRI Segmentation Using Dictionary Learning and Manifold Clustering

Purpose: The recent advent of MRI guided radiotherapy machines has lent an exciting platform for soft tissue target localization during treatment. However, tools to efficiently utilize MRI images for such purpose have not been developed. Specifically, to efficiently quantify the organ motion, we develop an automated segmentation method using dictionary learning and manifold clustering (DLMC). Methods: Fast 3D HASTE and VIBE MR images of 2 healthy volunteers and 3 patients were acquired. A bounding box was defined to include pancreas and surrounding normal organs including the liver, duodenum and stomach. The first slice of the MRI was used for dictionary learning based on mean-shift clustering and K-SVD sparse representation. Subsequent images were iteratively reconstructed until the error is less than a preset threshold. The preliminarily segmentation was subject to the constraints of manifold clustering. The segmentation results were compared with the mean shift merging (MSM), level set (LS) and manual segmentation methods. Results: DLMC resulted in consistently higher accuracy and robustness than comparing methods. Using manual contours as the ground truth, the mean Dices indices for all subjects are 0.54, 0.56 and 0.67 for MSM, LS and DLMC, respectively based on the HASTE image. The mean Dices indices are 0.70, 0.77 and 0.79 for the three methods based on VIBE images. DLMC is clearly more robust on the patients with the diseased pancreas while LS and MSM tend to over-segment the pancreas. DLMC also achieved higher sensitivity (0.80) and specificity (0.99) combining both imaging techniques. LS achieved equivalent sensitivity on VIBE images but was more computationally inefficient. Conclusion: We showed that pancreas and surrounding normal organs can be reliably segmented based on fast MRI using DLMC. This method will facilitate both planning volume definition and imaging guidance during treatment.

60 APPLIED LIFE SCIENCES↗

Spectra of helium clusters with up to six atoms using soft-core potentials

In this paper, we investigate small clusters of helium atoms using the hyperspherical harmonic basis. We consider systems with A=2,3,4,5,6 atoms with an interparticle potential which does not present a strong repulsion at short distances. We use an attractive Gaussian potential that reproduces the values of the dimer binding energy, the atom-atom scattering length, and the effective range obtained with one of the widely used He-He interactions, the Aziz and Slaman potential, called LM2M2. In systems with more than two atoms, we consider a repulsive three-body force that, by construction, reproduces the trimer binding energy of the LM2M2 potential. With this model, consisting of the sum of a two- and three-body potential, we have calculated the spectrum of clusters formed by four, five, and six helium atoms. We have found that these systems present two bound states, one deep and one shallow, close to the threshold fixed by the energy of the (A-1)-atom system. Universal relations between the energies of the excited state of the A-atom system and the ground-state energy of the (A-1)-atom system are extracted, as well as the ratio between the ground state of the A-atom system and the ground-state energy of the trimer.

74 ATOMIC AND MOLECULAR PHYSICS↗

Azimuthal-spin-wave-mode-driven vortex-core reversals

We studied, by micromagnetic numerical calculations, asymmetric vortex-core reversals driven by the m = −1 and m = +1 azimuthal spin-wave modes' excitations in soft magnetic circular nano-disks. We addressed the similarities and differences between the asymmetric core reversals in terms of the temporal evolutions of the correlated core-motion speed, locally concentrated perpendicular gyrofield, and magnetization dip near the original vortex core. The criterion for the core reversals was found to be the magnetization dip that must reach the out-of-plane magnetization component, m{sub z} = −p, with the initial polarization p, where p = +1 (−1) for the upward (downward) core magnetization. The core-motion speed and the associated perpendicular gyrofield, variable and controllable with static perpendicular field, H{sub z}, applied perpendicularly to the disk plane, must reach their threshold values to meet the ultimate core-reversal criterion. Also, we determined the H{sub z} strength and direction dependence of the core-switching time and threshold exciting field strength required for the core reversals, whose parameters are essential in the application aspect. This work offers deeper insights into the azimuthal spin-wave-driven core-reversal dynamics as well as an efficient means of controlling the azimuthal-modes-driven core reversals.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Image Guided Planning for Prostate Carcinomas With Incorporation of Anti-3-[18F]FACBC (Fluciclovine) Positron Emission Tomography: Workflow and Initial Findings From a Randomized Trial

Purpose: {sup 18}F-Fluciclovine (anti-1-amino-3-[{sup 18}F]fluorocyclobutane-1-carboxylic acid) is a novel positron emission tomography (PET)/computed tomography (CT) radiotracer that has demonstrated utility for detection of prostate cancer. Our goal is to report the initial results from a randomized controlled trial of the integration of {sup 18}F-fluciclovine PET-CT into treatment planning for defining prostate bed and lymph node target volumes. Methods and Materials: We report our initial findings from a cohort of 41 patients, of the first enrolled on a randomized controlled trial, who were randomized to the {sup 18}F-fluciclovine arm. All patients underwent {sup 18}F-fluciclovine PET-CT for the detection of metabolic abnormalities and high-resolution CT for treatment planning. The 2 datasets were registered first by use of a rigid registration. If soft tissue displacement was observable, the rigid registration was improved with a deformable registration. Each {sup 18}F-fluciclovine abnormality was segmented as a percentage of the maximum standard uptake value (SUV) within a small region of interest around the lesion. The percentage best describing the SUV falloff was integrated in planning by expanding standard target volumes with the PET abnormality. Results: In 21 of 55 abnormalities, a deformable registration was needed to map the {sup 18}F-fluciclovine activity into the simulation CT. The most selected percentage was 50% of maximum SUV, although values ranging from 15% to 70% were used for specific patients, illustrating the need for a per-patient selection of a threshold SUV value. The inclusion of {sup 18}F-fluciclovine changed the planning volumes for 46 abnormalities (83%) of the total 55, with 28 (51%) located in the lymph nodes, 11 (20%) in the prostate bed, 10 (18%) in the prostate, and 6 (11%) in the seminal vesicles. Only 9 PET abnormalities were fully contained in the standard target volumes based on the CT-based segmentations and did not necessitate expansion. Conclusions: The use of {sup 18}F-fluciclovine in postprostatectomy radiation therapy planning was feasible and led to augmentation of the target volumes in the majority (30 of 41) of the patients studied.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Controlling electron quantum paths for generation of circularly polarized high-order harmonics by H 2 + subject to tailored (ω, 2ω) counter-rotating laser fields

Recently, studies of high-order harmonics (HHG) from atoms driven by bichromatic counter-rotating circularly polarized laser fields as a source of coherent circularly polarized extreme ultraviolet (XUV) and soft-x-ray beams in a tabletop-scale setup have received considerable attention. Here, we demonstrate the ability to control the electron recollisions giving three returns per one cycle of the fundamental frequency ω by using tailored bichromatic (ω, 2ω) counter-rotating circularly polarized laser fields with a molecular target. The full control of the electronic pathway is first analyzed by a classical trajectory analysis and then extended to a detailed quantum study of H 2 + molecules in bichromatic (ω, 2ω) counter-rotating circularly polarized laser fields. The radiation spectrum contains doublets of left- and right-circularly polarized harmonics in the XUV ranges. Finally, we study in detail the below-, near-, and above-threshold harmonic regions and describe how excited-state resonances alter the ellipticity and phase of the generated harmonic peaks.

74 ATOMIC AND MOLECULAR PHYSICS↗

Encapsulation of Monolayer 2D Materials Using Kinetic Energy-Controlled Pulsed Laser Deposition

The integration of monolayer (ML) two-dimensional (2D) materials into next-generation microelectronics, optoelectronics, and sensors is hindered by their sensitivity to environmental exposure. Deposition of additional layers for encapsulation or growth on ML 2D materials by versatile but energetic plasma techniques such as pulsed laser deposition (PLD) has not been considered at the monolayer level because of potential damage caused by hyperthermal species with kinetic energies (KEs) exceeding the threshold displacement energy (TDE) of the ML. Here, we describe a general strategy to understand and mitigate damage during PLD by reducing the incident KE of ablated species below the TDE of the 2D monolayer using background gas collisions. Ion flux diagnostics, combined with in situ Raman spectroscopy of monolayer graphene during PLD of amorphous boron nitride (a-BN) as a dielectric encapsulation layer, show that damage is primarily correlated with fast ions that penetrate the background gas in accordance with Beer’s Law and are often overlooked in ICCD imaging due to the dominance of the bright, delayed plasma luminescence. Significantly, if fast ions are eliminated and a ∼2 nm-thick a-BN layer is “soft landed”, the monolayer graphene is effectively protected from damage by high KE species in the boron nitride plasma plume. Deposited a-BN films display a characteristic dielectric constant of 3.6 at 100 kHz and tunable charge injection properties. Our results enable PLD as a viable option for encapsulation and thin film growth onto ML 2D materials, with implications for both fundamental research and device integration.

2D materials↗

Rayleigh-Taylor-instability experiments with elastic-plastic materials

A rotating wheel experimental facility was developed to investigate incompressible Rayleigh-Taylor instability in elastic-plastic materials. A soft solid (mayonnaise) was chosen as the elastic-plastic material for experiments; material properties that include shear modulus and yield strength were fully characterized using a vane spindle type rheometer. Initial perturbations of varying amplitudes and wavelengths were generated on the interface of the soft solid using sinusoidal cutting guides. A backlit imaging technique was used in conjunction with a high-speed camera to track the motion of the interface at various phases of the instability. Results for both two- and three-dimensional perturbations were compared to study the acceleration required for instability and the growth after the interface yielded. Exponential growth rates were observed after instability was reached with trends of increasing growth rates for lower initial amplitudes. It was found that the acceleration required for instability increased when initial amplitude and wavelength decreased. Here, three-dimensional interfaces were found to be more stable. For both cases, a decrease in initial amplitude produced a more stable interface that increased the threshold acceleration required for the instability. Critical amplitude conditions for instability were calculated and compared with various analytical models and other experimental results.

42 ENGINEERING↗

HOW SOFT GAMMA REPEATERS MIGHT MAKE FAST RADIO BURSTS

There are several phenomenological similarities between soft gamma repeaters (SGRs) and fast radio bursts (FRBs), including duty factors, timescales, and repetition. The sudden release of magnetic energy in a neutron star magnetosphere, as in popular models of SGRs, can meet the energy requirements of FRBs, but requires both the presence of magnetospheric plasma, in order for dissipation to occur in a transparent region, and a mechanism for releasing much of that energy quickly. FRB sources and SGRs are distinguished by long-lived (up to thousands of years) current-carrying coronal arches remaining from the formation of the young neutron star, and their decay ends the phase of SGR/AXP/FRB activity even though “magnetar” fields may persist. Runaway increases in resistance when the current density exceeds a threshold, releases magnetostatic energy in a sudden burst, and produces high brightness GHz emission of FRB by a coherent process. SGRs are produced when released energy thermalizes as an equlibrium pair plasma. The failures of some alternative FRB models and the non-detection of SGR 1806-20 at radio frequencies are discussed in the appendices.

79 ASTRONOMY AND ASTROPHYSICS↗

Rapidity gap cross sections measured with the ATLAS detector in pp collisions at $\sqrt{s} = 7 \mbox{~TeV}$

Pseudorapidity gap distributions in proton-proton collisions at s√=7 ~TeVs=7 ~TeV are studied using a minimum bias data sample with an integrated luminosity of 7.1 μb -1 . Cross sections are measured differentially in terms of Δη F , the larger of the pseudorapidity regions extending to the limits of the ATLAS sensitivity, at η= ±4.9, in which no final state particles are produced above a transverse momentum threshold p$cut\atop{T}$ . The measurements span the region 0<Δη F < 8 for 200~MeV< p$cut\atop{T}$ <800~MeV200~MeV F , the data test the reliability of hadronisation models in describing rapidity and transverse momentum fluctuations in final state particle production. The measurements at larger gap sizes are dominated by contributions from the single diffractive dissociation process (pp→Xp), enhanced by double dissociation (pp→XY) where the invariant mass of the lighter of the two dissociation systems satisfies M Y ≲7 GeV. The resulting cross section is dσ/dΔη F ≈1 mb for Δη F ≳3. The large rapidity gap data are used to constrain the value of the Pomeron intercept appropriate to triple Regge models of soft diffraction. Finally, the cross section integrated over all gap sizes is compared with other LHC inelastic cross section measurements.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Complete multiwavelength evolution of Galactic black hole transients during outburst decay. I. Conditions for 'compact' jet formation

Compact, steady jets are observed in the near infrared and radio bands in the hard state of Galactic black hole transients as their luminosity decreases and the source moves toward a quiescent state. Recent radio observations indicate that the jets turn off completely in the soft state; therefore, multiwavelength monitoring of black hole transients is essential to probe the formation of jets. In this work, we conducted a systematic study of all black hole transients with near infrared and radio coverage during their outburst decays. We characterized the timescales of changes in X-ray spectral and temporal properties and also in near infrared and/or in radio emission. We confirmed that state transitions occur in black hole transients at a very similar fraction of their respective Eddington luminosities. We also found that the near infrared flux increase that could be due to the formation of a compact jet is delayed by a time period of days with respect to the formation of a corona. Finally, we found a threshold disk Eddington luminosity fraction for the compact jets to form. We explain these results with a model such that the increase in the near infrared flux corresponds to a transition from a patchy, small-scale height corona along with an optically thin outflow to a large-scale height corona that allows for collimation of a steady compact jet. We discuss the timescale of jet formation in terms of transport of magnetic fields from the outer parts of the disk, and we also consider two alternative explanations for the multiwavelength emission: hot inner accretion flows and irradiation.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-E-J-224: Using UTE and T1 Weighted Spin Echo Pulse Sequences for MR-Only Treatment Planning; Phantom Study

Purpose: Investigating a new approach in MRI based treatment planning using the combination of (Ultrashort Echo Time) UTE and T1 weighted spin echo pulse sequences to delineate air, bone and water (soft tissues) in generating pseudo CT images comparable with CT. Methods: A gel phantom containing chicken bones, ping pang balls filled with distilled water and air bubbles, was made. It scanned with MRI using UTE and 2D T1W SE pulse sequences with (in plane resolution= 0.53mm, slice thickness= 2 mm) and CT with (in plane resolution= 0.5 mm and slice thickness= 0.75mm) as a ground truth for geometrical accuracy. The UTE and T1W SE images were registered with CT using mutual information registration algorithm provided by Philips Pinnacle treatment planning system. The phantom boundaries were detected using Canny edge detection algorithm for CT, and MR images. The bone, air bubbles and water in ping pong balls were segmented from CT images using threshold 300HU, - 950HU and 0HU, respectively. These tissue inserts were automatically segmented from combined UTE and T1W SE images using edge detection and relative intensity histograms of the phantom. The obtained segmentations of air, bone and water inserts were evaluated with those obtained from CT. Results: Bone and air can be clearly differentiated in UTE images comparable to CT. Combining UTE and T1W SE images successfully segmented the air, bone and water. The maximum segmentation differences from combine MRI images (UTE and T1W SE) and CT are within 1.3 mm, 1.1mm for bone, air, respectively. The geometric distortion of UTE sequence is small less than 1 pixel (0.53 mm) of MR image resolution. Conclusion: Our approach indicates that MRI can be used solely for treatment planning and its quality is comparable with CT.

60 APPLIED LIFE SCIENCES↗

A macroscopic description of a generalized self-organized criticality system: Astrophysical applications

We suggest a generalized definition of self-organized criticality (SOC) systems: SOC is a critical state of a nonlinear energy dissipation system that is slowly and continuously driven toward a critical value of a system-wide instability threshold, producing scale-free, fractal-diffusive, and intermittent avalanches with power law-like size distributions. We develop here a macroscopic description of SOC systems that provides an equivalent description of the complex microscopic fine structure, in terms of fractal-diffusive transport (FD-SOC). Quantitative values for the size distributions of SOC parameters (length scales L, time scales T, waiting times Δt, fluxes F, and fluences or energies E) are derived from first principles, using the scale-free probability conjecture, N(L)dL∝L {sup –d}, for Euclidean space dimension d. We apply this model to astrophysical SOC systems, such as lunar craters, the asteroid belt, Saturn ring particles, magnetospheric substorms, radiation belt electrons, solar flares, stellar flares, pulsar glitches, soft gamma-ray repeaters, black-hole objects, blazars, and cosmic rays. The FD-SOC model predicts correctly the size distributions of 8 out of these 12 astrophysical phenomena, and indicates non-standard scaling laws and measurement biases for the others.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-F-J-211: Scatter Correction for Clinical Cone-Beam CT System Using An Optimized Stationary Beam Blocker with a Single Scan

Purpose: X-ray scatter photons result in significant image quality degradation of cone-beam CT (CBCT). Measurement based algorithms using beam blocker directly acquire the scatter samples and achieve significant improvement on the quality of CBCT image. Within existing algorithms, single-scan and stationary beam blocker proposed previously is promising due to its simplicity and practicability. Although demonstrated effectively on tabletop system, the blocker fails to estimate the scatter distribution on clinical CBCT system mainly due to the gantry wobble. In addition, the uniform distributed blocker strips in our previous design results in primary data loss in the CBCT system and leads to the image artifacts due to data insufficiency. Methods: We investigate the motion behavior of the beam blocker in each projection and design an optimized non-uniform blocker strip distribution which accounts for the data insufficiency issue. An accurate scatter estimation is then achieved from the wobble modeling. Blocker wobble curve is estimated using threshold-based segmentation algorithms in each projection. In the blocker design optimization, the quality of final image is quantified using the number of the primary data loss voxels and the mesh adaptive direct search algorithm is applied to minimize the objective function. Scatter-corrected CT images are obtained using the optimized blocker. Results: The proposed method is evaluated using Catphan@504 phantom and a head patient. On the Catphan©504, our approach reduces the average CT number error from 115 Hounsfield unit (HU) to 11 HU in the selected regions of interest, and improves the image contrast by a factor of 1.45 in the high-contrast regions. On the head patient, the CT number error is reduced from 97 HU to 6 HU in the soft tissue region and image spatial non-uniformity is decreased from 27% to 5% after correction. Conclusion: The proposed optimized blocker design is practical and attractive for CBCT guided radiation therapy. This work is supported by grants from Guangdong Innovative Research Team Program of China (Grant No. 2011S013), National 863 Programs of China (Grant Nos. 2012AA02A604 and 2015AA043203), the National High-tech R&D Program for Young Scientists by the Ministry of Science and Technology of China (Grant No. 2015AA020917)

60 APPLIED LIFE SCIENCES↗

X-ray diagnostic developments in the perspective of DEMO

Soft X-ray diagnostics at present are not adequate for a burning plasma experiment, neither in term of hardware nor as diagnostic conception. Detectors have to be radiation tolerant, easily shielded, with low sensitivity to neutrons and gammas and with energy discrimination. Layout and viewing capability should be more flexible, thanks to the use also of optical devices, going toward a configuration intermediate between discrete tomography and pure imaging. The general conception of these diagnostics should therefore evolve in the direction of pattern recognition for a real time feedback. This work is focused on the diagnostic developments undertaken at the ENEA- Frascati X-ray Laboratory, following in particular three directions: gas detector for fast and advanced high density tomography, C-MOS solid state imaging detectors for slow control and X-ray polycapillary optics. GEM gas detectors in photon counting mode (noise free) were developed in the range 1-30 keV having high efficiency, high time resolution (up to microseconds), energy discrimination in bands and optical flexibility. Discrimination of X-rays, neutrons and gammas has been demonstrated, thanks to the combination of intrinsic gain and discrimination thresholds, at neutron fluxes (10{sup 7} n/s*cm{sup 2}) comparable with the expected ones at the ports of ITER. GEM detectors are also extremely flexible in the design, allowing optimization of the measurements and solutions for shielding or minimization of the effect of background radiation. Two solid state C-MOS imagers working in photon counting mode, one based on Si semiconductor (Medipix-2, range 5-30 keV) and the other one having a CdTe sensor (Pixirad, range 2-100 keV) have been characterized in laboratory. C-MOS imagers have features and performances thoroughly complementary to the GEM detector and, thanks to their higher pixel density, could be used as remote imaging detectors coupled to optics. X-ray polycapillary lenses have been therefore studied in the laboratory both as imaging optical device (full lens) or to define a line of sight (cylinder lens); the preliminary results are encouraging toward the goal of using these lenses to transport X-ray radiation far from the reactor. Reflective or diffractive X-ray optics can be also an option for tomography. A GEM detector has been installed at KSTAR and in the next future hopefully the other approaches will be tested there: once their feasibility will be demonstrated, the issue of the improvement of the radiation tolerance will be faced and the development of algorithms for data analysis as well.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗