Search NASA⌕ Search

SEARCH · Search NASA

Results for “Solid angle”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

MO-E-17A-05: Individualized Patient Dosimetry in CT Using the Patient Dose (PATDOSE) Algorithm

Purpose: Radiation dose to the patient undergoing a CT examination has been the focus of many recent studies. While CTDIvol and SSDE-based methods are important tools for patient dose management, the CT image data provides important information with respect to CT dose and its distribution. Coupled with the known geometry and output factors (kV, mAs, pitch, etc.) of the CT scanner, the CT dataset can be used directly for computing absorbed dose. Methods: The HU numbers in a patient's CT data set can be converted to linear attenuation coefficients (LACs) with some assumptions. With this (PAT-DOSE) method, which is not Monte Carlo-based, the primary and scatter dose are computed separately. The primary dose is computed directly from the geometry of the scanner, x-ray spectrum, and the known patient LACs. Once the primary dose has been computed to all voxels in the patient, the scatter dose algorithm redistributes a fraction of the absorbed primary dose (based on the HU number of each source voxel), and the methods here invoke both tissue attenuation and absorption and solid angle geometry. The scatter dose algorithm can be run N times to include Nth-scatter redistribution. PAT-DOSE was deployed using simple PMMA phantoms, to validate its performance against Monte Carlo-derived dose distributions. Results: Comparison between PAT-DOSE and MCNPX primary dose distributions showed excellent agreement for several scan lengths. The 1st-scatter dose distributions showed relatively higher-amplitude, long-range scatter tails for the PAT-DOSE algorithm then for MCNPX simulations. Conclusion: The PAT-DOSE algorithm provides a fast, deterministic assessment of the 3-D dose distribution in CT, making use of scanner geometry and the patient image data set. The preliminary implementation of the algorithm produces accurate primary dose distributions however achieving scatter distribution agreement is more challenging. Addressing the polyenergetic x-ray spectrum and spatially dependent scatter fractions will improve algorithm accuracy. Funding Support: UC Davis Clinical and Translational Science Center (CTSC) Award; NIH IMSD Student Fellowship; Saxon Student Fellowship Disclosure: PATENT Royalties from Samsung for dosimetry algorithm.

60 APPLIED LIFE SCIENCES↗

TU-AB-201-09: Calibration of An Element of a New Directional Pd-103 Planar Source Array

Purpose: The CivaSheet™ is a new directional Pd-103 planar source array, with a variable number of discrete source elements referred to as “dots”. Each dot consists of a polymer capsule containing {sup 103}Pd and a gold shield that attenuates radiation on one side of the device to define hot and cold dose regions. Fluorescence from the gold shield is observed in the dot spectrum. Since CivaSheet™ is a planar directional source, conventional methods used for calibration of azimuthally symmetric sources are not applicable. The purpose of this work is to establish an air-kerma-strength standard and a transfer to a well chamber for clinical calibration. Methods: Primary air-kerma strength measurement of the dots was performed using a variable-aperture free-air chamber (VAFAC). Charge measurements were recorded using a well chamber with a custom insert. Anisotropy measurements were performed using a Sodium-Iodide detector. Spectral measurements were performed using a low-energy germanium detector and compared to a source without gold. The dot geometry was modeled using the MCNP6 radiation transport code. Results: Air-kerma strength measurements of a batch of four dots performed with the VAFAC were within ±1.5% of the average measured value and the measurement precision was within ±0.5%. Anisotropy measurements indicated uniform emission within the measurement uncertainty for the solid angle defining the VAFAC aperture used. Charge measurements of each dot using the well chamber in four cardinal angle source orientations were within ±1.5% of the average measured values. The spectral study of a dot resulted in identification of fluorescence from the gold shield and primary spectral energies that were compared to MCNP6 simulations. Conclusion: Calibration procedures for the new directional Pd-103 source dot were established for future clinical use, based on the results of experimental and Monte Carlo investigations. This work was partially supported by NCI contract (HHSN261201200052C) through CivaTech Oncology Inc.

60 APPLIED LIFE SCIENCES↗

TH-AB-201-05: Determining the Direction Distribution of the Primary Radiation for a Cyberknife-M6

Purpose: Radiation protection regulatory differentiates between primary and scatter radiation. Whereas for conventional clinical linear accelerators the solid angle for primary radiation is planar, the Cyberknife (Accuray Inc., Sunnyvale, CA) may point its beam in all spatial directions. In order to be able to judge on radiation protection calculations for a Cyberknife-M6 vault, the direction distribution for delivered plans was evaluated based on clinical experiences. Methods: The log-files of 121 delivered patient treatment plans were exported, divided into cranial and extra-cranial treatments and the delivered monitor units (MU) together with the corresponding beam directions were analyzed. This MU-weighted spatial distribution was then projected to a 9.5 × 5.9 × 3.9 m{sup 3} vault, generating an “intensity map” using a binning of 50 × 50 cm{sup 2}. The factor of direction (FOD) is reported as a fraction of the total applied MUs to the walls, ceiling and floor in the perspective of a patient lying in head-first-supine position on the couch. In this study, the term intFOD refers to the integral FOD and maxFOD refers to the maximal FOD for a single bin. Results: For all kind of treatments and collimators, intFOD and maxFOD for the wall behind the patient’s head is 0.0. The intFOD for the floor varies between 0.65 and 0.74. For the ceiling, maxFOD is 0.002 and 0.0 for cranial and extra-cranial cases, respectively. The intFOD for the wall at the patient’s feet, is 0.094 for cranial and 0.005 for extra-cranial cases. There is nearly no difference between the maxFOD of the right and left wall for cranial cases, whereas for extra-cranial cases these numbers differ by a factor of 1.75. Conclusion: The varying FODs for the Cyberknife were quantified based on delivered treatment plans. These findings are helpful regarding the design of Cyberknife vaults.

60 APPLIED LIFE SCIENCES↗

Total cross sections for photoabsorption on light nuclei in the energy range 600-1500 MeV

Experimental data of the GRAAL Collaboration on the total cross sections for photoabsorption on deuterium and carbon targets at gamma-ray energies in the range between 600 and 1500 MeV are presented. The experiment was performed in a beam of photons obtained by the method of the Compton backscattering of laser photons at the electron storage ring of the European Synchrotron Radiation Facility (ESRF, Grenoble, France) by using a wide-aperture detector covering a solid angle close to 4{pi}. The total photoabsorption cross sections were determined by two independent methods: by subtracting the emptytarget background and by summing partial cross sections for meson photoproduction. The total cross sections for photoabsorption on quasifree protons and neutrons are shown to agree both in magnitude and in shape within a 5% precision of the measurements. In contrast to data previously available in the literature, both cross sections show distinctly the F{sub 15}(1680) resonance at a photon energy of about 1 GeV. Data obtained in the present experiment for the cross sections for photoabsorption on a free and a bound nucleon are compared. This comparison reveals a substantial role of two-nucleon correlations in estimating the nuclear-medium effect on meson photoproduction.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

On the anisotropy of E{sub 0} Greater-Than-Or-Slanted-Equal-To 5.5 Multiplication-Sign 10{sup 19} eV cosmic rays according to data of the Pierre Auger Collaboration

The Pierre Auger Collaboration discovered, in a solid angle of radius about 18 Degree-Sign , a local group of cosmic rays having energies in the region E{sub 0} {>=} 5.5 Multiplication-Sign 10{sup 19} eV and coming from the region of the Gen A radio galaxy, whose galactic coordinates are l{sub G} 309.5 Degree-Sign and b{sub G} = 19.4 Degree-Sign . Near it, there is the Centaur supercluster of galaxies, its galactic coordinates being l{sub G} = 302.4 Degree-Sign and b{sub G} = 21.6 Degree-Sign . It is noteworthy that the Great Attractor, which may have a direct bearing on the observed picture, is also there.

79 ASTRONOMY AND ASTROPHYSICS↗

Creation and investigation of powerful EUV sources ({lambda} {approx} 13.5 nm)

Results are presented from experimental studies of repetitively pulsed EUV ({lambda} = 13.5 {+-} 0.135 nm) sources based on a laser-initiated discharge in tin vapor between rotating disk electrodes. Radiative characteristics of two sources with different systems of tin supply onto the electrode surface and different types of power supply have been compared. A number of new effects have been revealed at pulse repetition rates as high as {approx}4000 Hz. A mean radiation power of 520 W into the 2{pi} solid angle has been achieved in the spectral band 13.5 {+-} 0.135 nm at a deposited electrical power of 24 kW.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Gamma Ray Multiplicity of 252Cf Spontaneous Fission using LiBerACE

We are studying the gamma ray and neutron multiplicity of various fission processes, beginning with the spontaneous fission of {sup 252}Cf, for a variety of basic and applied science purposes. The Livermore-Berkeley Array for Collaborative Experiments (LiBerACE) consists of six high-purity germanium Clover detectors (HPGe) each enclosed by an array of 16 bismuth-germanate (BGO) detectors. These detectors were arranged in a cubic pattern around a 1 {micro}Ci {sup 252}Cf source to attempt to cover as much solid angle of gamma ray emission as possible with a high level of segmentation. The single-gamma detector response function is determined at several energies by tagging in a HPGe detector on the photopeak of one of two gamma rays in two-gamma ray calibration sources and observing the multiplicity of the remainder of the array. Summing these single-gamma responses in groups yields the response function of the array to higher multiplicity events, which are convolved with multiplicity distributions from theoretical models and compared to the measured results to test the models validity.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Robust Containment Queries over Collections of Trimmed NURBS Surfaces via Generalized Winding Numbers

Here, we propose a containment query that is robust to the watertightness of regions bound by trimmed NURBS surfaces, as this property is difficult to guarantee for in-the-wild CAD models. Containment is determined through the generalized winding number (GWN), a mathematical construction that is indifferent to the arrangement of surfaces in the shape. Applying contemporary techniques for the 3D GWN to trimmed NURBS surfaces requires some form of geometric discretization, introducing computational inefficiency to the algorithm and even risking containment misclassifications near the surface. In contrast, our proposed method leverages properties of the 3D solid angle to solve the relevant surface integral using a boundary formulation with rapidly converging adaptive quadrature. Batches of queries are further accelerated by memoizing (i.e., caching and reusing) quadrature node positions and tangents as they are evaluated. We demonstrate that our GWN method is robust to complex trimming geometry in a CAD model, and is accurate up to arbitrary precision at arbitrary distances from the surface. The derived containment query is therefore robust to model non-watertightness while respecting all curved features of the input shape.

97 MATHEMATICS AND COMPUTING↗

Fast, High-Resolution X-ray Microfluorescence Imaging

X-ray micro fluorescence imaging refers to the use of an x-ray beam as a probe to excite XRF in a specimen and produce a spatially resolved image of the element distribution. The advantages of high sensitivity and low background, together with the nondestructive nature of the measurement, have lead to applications of x-ray microfluorescence analysis in biology, geology, materials science, as well as in the area of nondestructive evaluation. Previous reports have described the development of an x-ray microprobe which uses a conventional source of x-rays to produce a 10-μm beam. This paper describes improvements to the microprobe which have increased the beam power and the solid angle of detection. The data collection and display software have also been enhanced.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

drtsans

drtsans is highly modular, allowing users to customize collected data as well as test hypothetical or simulated neutron events data. Instrument scientists can use the advance features of drtsans to calibrate their instruments and reduced large quantities of datasets in a streamlined mode. Users can correct the collected data with dark current subtraction and normalization by neutron flux, detector sensitivity, solid angle subtended by the detectors, and scaling to absolute units. Conversion from time-of-flight and/or wavelength to 1D or 2D momentum transfer renders the final scattering quantities amenable to analysis.

Bilheux, JeanC↗

Interferometric null test of a deep parabolic reflector generating a Hertzian dipole field

We report on interferometric characterization of a deep parabolic mirror with a depth of more than five times its focal length. The interferometer is of Fizeau type; its core consists of the mirror itself, a spherical null element, and a reference flat. Because of the extreme solid angle produced by the paraboloid, the alignment of the setup appears to be very critical and needs auxiliary systems for control. Aberrations caused by misalignments are removed via fitting of suitable functionals provided by means of ray tracing simulations. It turns out that the usual misalignment approximations fail under these extreme conditions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High Miller-Index Germanium Crystals For High-Energy X-ray Imaging Applications

Near-normal-incidence bent crystals are widely used for x-ray imaging applications. Advantages include high collection solid angle and potentially high efficiency for narrow-band sources, while disadvantages include relatively large (several Å) interatomic spacings and a limited number of suitable matches between a crystal 2d value and an integral multiple of useful emission line wavelengths. The disadvantages become more significant at x-ray energies >10 keV. The former disadvantage can be mitigated by using high-order reflections from crystal planes having low Miller indices, but both disadvantages can be mitigated by using low-order reflections from crystal planes having high Miller indices. We report here on integrated reflectivity measurements we performed of Ge (15,7,7) (2d=0.6296 Å), a candidate for imaging Ru He-α (θ(B)=87°). We find good agreement with calculations, and the data show a multitude of closely spaced reflections with slightly different Bragg angles including a fifth-order reflection of Ge (3,1,1) that has comparable reflectivity. This demonstrates that arbitrary choices of Miller indices in Ge crystals can be used to fine-tune Bragg angles for near-normal-incidence x-ray imaging at tens of kiloelectron volt x-ray energies with minimal lower-energy contamination from lower-order reflections, and that existing calculational tools can be used to reliably estimate integrated reflectivity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comment on elimination of polarization dependence from optical excitation functions

The measurement of optical excitation functions excited by electron impact is typically accomplished by recording atomic fluorescence emitted into a small solid angle perpendicular to the incident electron beam. This measured intensity is not proportional to the emission cross section because the fluorescence exhibits an angular distribution and polarization that varies with the energy of the exciting electrons. Typically, a polarizer is set at the ''magic angle'' (54.7 degree sign ) with respect to the electron beam axis to remove this polarization dependence. The literature for the derivation of the magic angle value assumes the polarizing element is perfect. An expression for the angle that accounts for the use of a partial polarizer is presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Theory of Compton scattering in ignited thermonuclear plasmas

Inertially confined, ignited thermonuclear deuterium-tritium plasmas will produce intense blackbody radiation at temperatures of T(greater-or-similar sign)20 keV; it is shown that the injection of GeV electrons into the burning core can efficiently generate high-energy Compton scattering photons, as the high blackbody photon density alleviates the small interaction cross section. Moreover, it is shown that the spectrum scattered in a small solid angle can be remarkably monochromatic, due to kinematic pileup; peak brightness in excess of 10{sup 30} photons/(mm{sup 2} mrad{sup 2} s 0.1% bandwidth) are predicted. These results are also discussed within the context of the Schwinger field and the Sunyaev-Zel'dovich effect.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Spin-phonon coupling in AFM transition-metal mono-oxide

Time-of-flight INS measurements were performed on single crystal NiO with the Wide Angular Range Chopper Spectrometer (ARCS) at the Spallation Neutron Source. Experiments were performed on NiO single crystal mounted in an aluminum can and cooled using a closed-cycle helium refrigerator. Measurements were conducted at T = 100 K and 650 K, with the [HHL] scattering plane aligned horizontally. A Fermi chopper with slit spacing of 1.52mm, spinning at 300 Hz, was used to select an incident neutron energy of 100 meV. All datasets were normalized to a vanadium standard to correct for detector efficiency and solid angle coverage. The data sets include the .nxs files, the generated .hdf5 files (for use with Phonon Explorer), and Python scripts used to create them.

36 MATERIALS SCIENCE↗

Muon Fluence Measurements for Homeland Security Applications

This report focuses on work conducted at Pacific Northwest National Laboratory to better characterize aspects of backgrounds in RPMs deployed for homeland security purposes. Two polyvinyl toluene scintillators were utilized with supporting NIM electronics to measure the muon coincidence rate. Muon spallation is one mechanism by which background neutrons are produced. The measurements performed concentrated on a broad investigation of the dependence of the muon flux on a) variations in solid angle subtended by the detector; b) the detector inclination with the horizontal; c) depth underground; and d) diurnal effects. These tests were conducted inside at Building 318/133, outdoors at Building 331G, and underground at Building 3425 at Pacific Northwest National Laboratory.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

NSLS-II Preliminary Design Report

Following the CD0 approval of the National Synchrotron Light Source II (NSLS-II) during August 2005, Brookhaven National Laboratory prepared a conceptual design for a worldclass user facility for scientific research using synchrotron radiation. DOE SC review of the preliminary baseline in December 2006 led to the subsequent CD1 approval (approval of alternative selection and cost range). This report is the documentation of the preliminary design work for the NSLS-II facility. The preliminary design of the Accelerator Systems (Part 1) was developed mostly based of the Conceptual Design Report, except for the Booster design, which was changed from in-storage-ring tunnel configuration to in external- tunnel configuration. The design of beamlines (Part 2) is based on designs developed by engineering firms in accordance with the specification provided by the Project. The conventional facility design (Part 3) is the Title 1 preliminary design by the AE firm that met the NSLS-II requirements. Last and very important, Part 4 documents the ES&H design and considerations related to this preliminary design. The NSLS-II performance goals are motivated by the recognition that major advances in many important technology problems will require scientific breakthroughs in developing new materials with advanced properties. Achieving this will require the development of new tools that will enable the characterization of the atomic and electronic structure, chemical composition, and magnetic properties of materials, at nanoscale resolution. These tools must be nondestructive, to image and characterize buried structures and interfaces, and they must operate in a wide range of temperatures and harsh environments. The NSLS-II facility will provide ultra high brightness and flux and exceptional beam stability. It will also provide advanced insertion devices, optics, detectors, and robotics, and a suite of scientific instruments designed to maximize the scientific output of the facility. Together these will enable the study of material properties and functions with a spatial resolution of {approx}1 nm, an energy resolution of {approx}0.1 meV, and the ultra high sensitivity required to perform spectroscopy on a single atom. In order to meet this need, NSLS-II has been designed to provide world-leading brightness and flux and exceptional beam stability. The brightness is defined as the number of photons emitted per second, per photon energy bandwidth, per solid angle, and per unit source size. Brightness is important because it determines how efficiently an intense flux of photons can be refocused to a small spot size and a small divergence. It scales as the ring current and the number of total periods of the undulator field (both of which contribute linearly to the total flux), as well as eing nversely proportional to the horizontal and vertical emittances (the product of beam size and divergence) of the electron beam. Raising the current in the storage ring to obtain even brighter beams is ultimately limited by beam-driven, collective instabilities in the accelerator. Thus, to maximize the brightness, the horizontal and vertical emittances must be made as small as possible. With the concept of using damping wigglers, low-field bending magnets, and a large number of lattice cells to achieve ultra small emittance, the performance of NSLS-II will be nearly at the ultimate limit of storage ring light sources, set by the intrinsic properties of the synchrotron radiation process. The facility will produce x-rays more than 10,000 times brighter than those produced at NSLS today. The facility, with various insertion devices, including three-pole-wigglers and low-field dipole radiations, has the capability of covering a broad range of radiation spectra, from hard x-ray to far infra-red. The superlative character and combination of capabilities will have broad impact on a wide range of disciplines and scientific initiatives in the coming decades, including new studies of small crystals in structural biology, a wide range of nanometer-resolution probes for nanoscience, coherent imaging of the structure and dynamics of disordered materials, greatly increased applicability of inelastic x-ray scattering, and properties of materials under extreme conditions. Commissioned in 1982, the existing National Synchrotron Light Source (NSLS) provides essential scientific tools for 2,300 scientists per year from more than 400 academic, industrial, and government institutions. Their myriad research programs produce about 800 publications per year, with more than 130 appearing in premier journals. It was designed in the 1970s and is now in its third decade of service. It has been continually upgraded over the years, with the brightness increasing fully five orders of magnitude. However, it has reached the theoretical limits of performance given its small circumference and small periodicity, and only a small number of insertion devices are possible.

43 PARTICLE ACCELERATORS↗