Search NASA⌕ Search

SEARCH · Search NASA

Results for “Spatial resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Towards the spatial resolution of metalloprotein charge states by detailed modeling of XFEL crystallographic diffraction

Oxidation states of individual metal atoms within a metalloprotein can be assigned by examining X-ray absorption edges, which shift to higher energy for progressively more positive valence numbers. Indeed, X-ray crystallography is well suited for such a measurement, owing to its ability to spatially resolve the scattering contributions of individual metal atoms that have distinct electronic environments contributing to protein function. However, as the magnitude of the shift is quite small, about +2 eV per valence state for iron, it has only been possible to measure the effect when performed with monochromated X-ray sources at synchrotron facilities with energy resolutions in the range 2–3 × 10 −4 (Δ E / E ). This paper tests whether X-ray free-electron laser (XFEL) pulses, which have a broader bandpass (Δ E / E = 3 × 10 −3 ) when used without a monochromator, might also be useful for such studies. The program nanoBragg is used to simulate serial femtosecond crystallography (SFX) diffraction images with sufficient granularity to model the XFEL spectrum, the crystal mosaicity and the wavelength-dependent anomalous scattering factors contributed by two differently charged iron centers in the 110-amino-acid protein, ferredoxin. Bayesian methods are then used to deduce, from the simulated data, the most likely X-ray absorption curves for each metal atom in the protein, which agree well with the curves chosen for the simulation. The data analysis relies critically on the ability to measure the incident spectrum for each pulse, and also on the nanoBragg simulator to predict the size, shape and intensity profile of Bragg spots based on an underlying physical model that includes the absorption curves, which are then modified to produce the best agreement with the simulated data. This inference methodology potentially enables the use of SFX diffraction for the study of metalloenzyme mechanisms and, in general, offers a more detailed approach to Bragg spot data reduction.

59 BASIC BIOLOGICAL SCIENCES↗

Mapping wall-to-wall fractional cover of Arctic tundra plant functional types in Alaska using 20-m spatial resolution satellite imagery and harmonized plot observations

Estimates of fractional cover (fCover) across given land surfaces are used to assess, and often model, vegetation composition and diversity, which are crucial for understanding the health and functioning of terrestrial ecosystems. Remote sensing provides a useful means for scaling local, plot-measured fCover estimates to regional scales. Leveraging a recently synthesized and harmonized plot database, this study generated wall-to-wall maps of fCover for six Alaskan-Arctic plant functional types (PFT), including non-vascular plants, forbs, graminoids, and deciduous and evergreen shrubs, using 20-m satellite data (Sentinel-1, Sentinel-2, ArcticDEM) using a machine learning regression approach, specifically the random forest (RF) algorithm, which is well-suited for handling nonlinear relationships and high-dimensional satellite datasets. This study additionally addressed the spatio-temporal inconsistencies e.g., sampling scale, plot size, and collection year in plot measured fCover by adopting a multivariate outlier detection approach—Cook’s distance—to identify high-quality plots for model training and validation. Our approach achieves high accuracy (R 2 = 0.59–0.93, root mean squared errors = 0.02–0.10 for all PFTs) between plot-observed and satellite-derived fCover when using high-quality plot samples. The mapped fCover characterizes the spatial patterns of different PFTs across the tundra biome at a 20-m resolution, providing key information needed for improved representation of Arctic tundra vegetation in terrestrial biosphere models to better understand climate-vegetation feedback across the Arctic tundra.

Arctic tundra↗

Reduction of Stored NOx with CO/H2 and Hydrocarbons: A Spatial Resolution Analysis

Lean NOx traps (LNT) are multi-function multi-component catalysts which operate in an integral and transient reactor mode to reduce NOx in the exhaust from diesel or lean-burn gasoline engines. This chapter addresses the regeneration phase of the LNT operation, discussing various types of reductants and reactions involved. We describe how reductants of different reactivity influence catalyst functions, reactions, and overall regeneration efficiency. The presented examples highlight the importance of understanding the spatial and temporal development of key reactions and their interplay to rationalize the global performance of practical LNTs which are generally honeycomb-shaped ceramic monoliths. The emphasis is on explaining global NOx removal performance (i.e., activity and selectivity) based on the insights gained through spatially resolved techniques, including initial distribution and redistribution of stored NOx; oxygen storage and reduction; transformation of feed reductants; and formation and utilization of reduction intermediates. Pathways leading to N2O and NH3 byproduct formation as well as mitigation strategies are also discussed.

Choi, Jae-Soon↗

Quantitative Nonlinear Optical Polarimetry with High Spatial Resolution

Nonlinear optical microscopy such as in the optical second-harmonic generation (SHG) modality has become a popular tool today for probing materials in the physical and biological sciences. While imaging and spectroscopy are widely used in the microscopy mode, nonlinear polarimetry, which can shed light on materials’ symmetry and microstructure, is relatively underdeveloped. This is partly because quantitative analytical modeling of the optical SHG response for anisotropic crystals and films largely assumes low-numerical aperture (NA) focusing of light, where the plane-wave approximation is sufficient. Tight focusing provides unique benefits in revealing out-of-plane polarization responses, which cannot be detected by near-plane-wave illumination at normal incidence. Here, we outline a method for quantitatively analyzing SHG polarimetry measurements obtained under high-NA focusing within a microscope geometry. Experiments and simulations of a variety of standard samples, from single crystals to thin films, are in good agreement, including measured and simulated spatial SHG maps of ferroelectric domains. A solution to the inverse problem is demonstrated, where the spatial distribution of an SHG tensor with unknown tensor coefficient magnitudes is determined by experimentally measured polarimetry. The ability to extract the out-of-plane component of the nonlinear polarization in normal incidence is demonstrated, which can be valuable for high-resolution polarimetry of 2D materials, thin films, heterostructures, and uniaxial crystals with a strong out-of-plane response.

36 MATERIALS SCIENCE↗

Transmission Interface Limits for High-Spatial Resolution Capacity Expansion Modeling

Large-scale capacity expansion models typically rely on estimates of the power transfer limits between modeled zones. Accurate estimation of these interface transfer limits (ITLs) requires modeling the underlying transmission network. Here we expand on a maximum flow optimization method that uses linearized power flow to estimate transfer limits. We apply this method to a data set of the U.S. transmission network to estimate ITLs between U.S. counties. By calculating ITLs using different subsets of the network, we evaluate how the size of the network used in the estimation affects the results. The results show diminishing returns to ITL accuracy after six hops, suggesting that a network subset can reasonably be used to approximate ITLs. The county-level estimates produced in this study will support more spatially resolved capacity expansion modeling and will help inform policy making at local and national levels.

capacity planning↗

Transmission Interface Limits for High-Spatial Resolution Capacity Expansion Modeling

Large-scale capacity expansion models typically rely on estimates of the power transfer limits between modeled zones. Accurate estimation of these interface transfer limits (ITLs) requires modeling the underlying transmission network. Here we expand on a maximum flow optimization method that uses linearized power flow to estimate transfer limits. We apply this method to a data set of the U.S. transmission network to estimate ITLs between U.S. counties. By calculating ITLs using different subsets of the network, we evaluate how the size of the network used in the estimation affects the results. The results show diminishing returns to ITL accuracy after six hops, suggesting that a network subset can reasonably be used to approximate ITLs. The county-level estimates produced in this study will support more spatially resolved capacity expansion modeling and will help inform policy making at local and national levels.

capacity planning↗

Developing a platform for Fresnel diffractive radiography with 1 μ m spatial resolution at the National Ignition Facility

An x-ray Fresnel diffractive radiography platform was designed for use at the National Ignition Facility. It will enable measurements of micron-scale changes in the density gradients across an interface between isochorically heated warm dense matter materials, the evolution of which is driven primarily through thermal conductivity and mutual diffusion. Here we use 4.75 keV Ti K-shell x-ray emission to heat a 1000 μm diameter plastic cylinder, with a central 30 μm diameter channel filled with liquid D 2 , up to 8 eV. This leads to a cylindrical implosion of the liquid D 2 column, compressing it to ~2.3 g/cm 3 . After pressure equilibration, the location of the D 2 /plastic interface remains steady for several nanoseconds, which enables us to track density gradient changes across the material interface with high precision. For radiography, we use Cu He- α x rays at 8.3 keV. Using a slit aperture of only 1 μm width increases the spatial coherence of the source, giving rise to significant diffraction features in the radiography signal, in addition to the refraction enhancement, which further increases its sensitivity to density scale length changes at the D 2 /plastic interface.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Predicting vehicular emissions in high spatial resolution using pervasively measured transportation data and microscopic emissions model

Air pollution related to traffic emissions pose an especially significant problem in cities; this is due to its adverse impact on human health and well-being. Previous studies which have aimed to quantify emissions from the transportation sector have been limited by either simulated or coarsely resolved traffic volume data. Emissions inventories form the basis of urban pollution models, therefore in this study, Global Positioning System (GPS) trajectory data from a taxi fleet of over 15,000 vehicles were analyzed with the aim of predicting air pollution emissions for Singapore. This novel approach enabled the quantification of instantaneous drive cycle parameters in high spatio-temporal resolution, which provided the basis for a microscopic emissions model. Carbon dioxide (CO2), nitrogen oxides (NOx), volatile organic compounds (VOCs) and particulate matter (PM) emissions were thus estimated. Highly localized areas of elevated emissions levels were identified, with a spatio-temporal precision not possible with previously used methods for estimating emissions. Relatively higher emissions areas were mainly concentrated in a few districts that were the Singapore Downtown Core area, to the north of the central urban region and to the east of it. Daily emissions quantified for the total motor vehicle population of Singapore were found to be comparable to another emissions dataset Results demonstrated that high resolution spatio-temporal vehicle traces detected using GPS in large taxi fleets could be used to infer highly localized areas of elevated acceleration and air pollution emissions in cities, and may become a complement to traditional emission estimates, especially in emerging cities and countries where reliable fine-grained urban air quality data is not easily available. This is the first study of its kind to investigate measured microscopic vehicle movement in tandem with microscopic emissions modeling for a substantial study domain.

54 ENVIRONMENTAL SCIENCES↗

Leveraging staggered tessellation for enhanced spatial resolution in high-granularity calorimeters

Here we advance the concept of high-granularity calorimeters with staggered tessellations, underscoring the effectiveness of a design incorporating multifold staggering cycles based on hexagonal cells to enhance position resolution. Moreover, we introduce HEXPLIT, a sub-cell re-weighting algorithm tailored to harness staggered designs, resulting in additional performance improvements. By combining our proposed staggered design with HEXPLIT, we achieve an approximately twofold enhancement in position resolution for neutrons across a wide energy range, as compared to unstaggered designs. These findings hold the potential to elevate particle-flow performance across various forthcoming facilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spatial Resolution in Scanning Electron Microscopy and Scanning Transmission Electron Microscopy Without a Specimen Vacuum Chamber

Abstract A long-standing goal of electron microscopy has been the high-resolution characterization of specimens in their native environment. However, electron optics require high vacuum to maintain an unscattered and focused probe, a challenge for specimens requiring atmospheric or liquid environments. Here, we use an electron-transparent window at the base of a scanning electron microscope’s objective lens to separate column vacuum from the specimen, enabling imaging under ambient conditions, without a specimen vacuum chamber. We demonstrate in-air imaging of specimens at nanoscale resolution using backscattered scanning electron microscopy (airSEM) and scanning transmission electron microscopy. We explore resolution and contrast using Monte Carlo simulations and analytical models. We find that nanometer-scale resolution can be obtained at gas path lengths up to 400 μ m, although contrast drops with increasing gas path length. As the electron-transparent window scatters considerably more than gas at our operating conditions, we observe that the densities and thicknesses of the electron-transparent window are the dominant limiting factors for image contrast at lower operating voltages. By enabling a variety of detector configurations, the airSEM is applicable to a wide range of environmental experiments including the imaging of hydrated biological specimens and in situ chemical and electrochemical processes.

Nguyen, Kayla X. (ORCID:0000000192537064)↗

The NanoSIMS-HR: The Next Generation of High Spatial Resolution Dynamic SIMS

The high lateral resolution and sensitivity of the NanoSIMS 50 and 50L series of dynamic SIMS instruments have enabled numerous scientific advances over the past 25 years. Here, in this study, we report on the NanoSIMS-HR, the first major upgrade to the series, and analytical tests in a suite of sample types, including an aluminum sample containing silicon crystals, microalgae, and plant roots colonized with a symbiotic fungus. Significant improvements have been made in the Cs + ion source, high voltage (HV) control, stage reproducibility, and other aspects of the instrument that affect performance. The modified design of the NanoSIMS-HR thermal-ionization Cs + source enables a 5 pA primary ion beam to be focused into a 100 nm spot, a ~2.5-fold increase compared to Cs + sources on previous instruments (~2 pA at 100 nm). The brightness of the new Cs + source enables an ultimate lateral resolution as high as 30 nm and improved detection limits for a given analysis area. Sample stage movement accuracy is higher than 500 nm, enabling many-fold higher throughput automated analyses. With the new HV control, the primary ion beam impact energy can be reduced from 16 to 2 keV, which enables higher depth resolution during depth profiling (a 2-fold improvement), albeit with a 5-fold decrease in lateral resolution. In the NanoSIMS-HR, the secondary ion column and detection system are identical to those used in the previous series, and the isotopic analysis performance is as precise as in previous NanoSIMS instruments.

54 ENVIRONMENTAL SCIENCES↗