Search NASA⌕ Search

SEARCH · Search NASA

Results for “Spectrometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Key Elements of a Low Voltage, Ultracompact Plasma Spectrometer

Taking advantage of technological developments in wafer-scale processing over the past two decades, such as deep etching, 3-D chip stacking, and double-sided lithography, we have designed and fabricated the key elements of an ultracompact 1.5cm (exp 3)plasma spectrometer that requires only low-voltage power supplies, has no microchannel plates, and has a high aperture area to instrument volume ratio. The initial design of the instrument targets the measurement of charged particles in the 3-20keV range with a highly directional field of view and a 100 duty cycle; i.e., the entire energy range Is continuously measured. In addition to reducing mass, size, and voltage requirements, the new design will affect the manufacturing process of plasma spectrometers, enabling large quantities of identical instruments to be manufactured at low individual unit cost. Such a plasma spectrometer is ideal for heliophysics plasma investigations, particularly for small satellite and multispacecraft missions. Two key elements of the instrument have been fabricated: the collimator and the energy analyzer. An initial collimator transparency of 20 with 3deg x 3deg angular resolution was achieved. The targeted 40 collimator transparency appears readily achievable. The targeted energy analyzer scaling factor of 1875 was achieved; i.e.20 keV electrons were selected for only a 10.7V bias voltage in the energy analyzer.

Scime, E. E.↗

Miniature X-Ray Solar Spectrometer: A Science-Oriented, University 3U CubeSat

The miniature x-ray solar spectrometer is a three-unit CubeSat developed at the Laboratory for Atmospheric and Space Physics at the University of Colorado, Boulder. Over 40 students contributed to the project with professional mentorship and technical contributions from professors in the Aerospace Engineering Sciences Department at University of Colorado, Boulder and from Laboratory for Atmospheric and Space Physics scientists and engineers. The scientific objective of the miniature x-ray solar spectrometer is to study processes in the dynamic sun, from quiet sun to solar flares, and to further understand how these changes in the sun influence the Earth's atmosphere by providing unique spectral measurements of solar soft x-rays. The enabling technology providing the advanced solar soft x-ray spectral measurements is the Amptek X123, a commercial off-the-shelf silicon drift detector. The Amptek X123 has a low mass (approx. 324 g after modification), modest power consumption (approx. 2.50 W), and small volume (6.86 x 9.91 x 2.54 cm), making it ideal for a CubeSat. This paper provides an overview of the miniature x-ray solar spectrometer mission: the science objectives, project history, subsystems, and lessons learned, which can be useful for the small-satellite community.

Mason, James P.↗

Dual Ion Spectrometers and Their Calibration for the Fast Plasma Investigation on NASA's Magnetospheric Multiscale Mission

The scientific target of NASA's Magnetospheric Multiscale (MMS) mission is to study the fundamentally important phenomenon of magnetic reconnection. Theoretical models of this process predict a small size, on the order of hundred kilometers, for the ion diffusion region where ions are demagnetized at the dayside magnetopause. This region may typically sweep over the spacecraft at relatively high speeds of 50 km/s, requiring the fast plasma investigation (FPI) instrument suite to have an extremely high time resolution for measurements of the 3D particle distribution functions. As part of the FPI on MMS, the 16 dual ion spectrometers (DIS) will provide fast (150 ms) 3D ion velocity distributions, from 10 to 30,000 eV/q, by combining the measurements from four dual spectrometers on each of four MMS spacecraft. For any multispacecraft mission, the response uniformity among the spectrometer set assumes an enhanced importance. Due to these demanding instrument requirements and the effort of calibrating more than 32 sensors (16 × 2) within a tight schedule, a highly systematic and precise calibration was required for measurement repeatability. To illustrate how this challenge was met, a brief overview of the FPI DIS was presented with a detailed discussion of the calibration method of approach and implementation. Finally, a discussion of DIS performance results, their unit-to-unit variation, and the lessons learned from this calibration effort are presented.

Coffey, V. N.↗

Composite Infrared Spectrometer (CIRS) on Cassini

The Cassini spacecraft orbiting Saturn carries the composite infrared spectrometer (CIRS) designed to study thermal emission from Saturn and its rings and moons. CIRS, a Fourier transform spectrometer, is an indispensable part of the payload providing unique measurements and important synergies with the other instruments. It takes full advantage of Cassini's 13-year-long mission and surpasses the capabilities of previous spectrometers on Voyager 1 and 2. The instrument, consisting of two interferometers sharing a telescope and a scan mechanism, covers over a factor of 100 in wavelength in the mid and far infrared. It is used to study temperature, composition, structure, and dynamics of the atmospheres of Jupiter, Saturn, and Titan, the rings of Saturn, and surfaces of the icy moons. CIRS has returned a large volume of scientific results, the culmination of over 30 years of instrument development, operation, data calibration, and analysis. As Cassini and CIRS reach the end of their mission in 2017, we expect that archived spectra will be used by scientists for many years to come.

Jennings, Donald E.↗

Numerical Investigation of Ion Transport in the MOMA Ion Mass Spectrometer

The Mars Organic Molecule Analyzer (MOMA) is a miniature ion trap mass spectrometer designed for the upcoming ExoMars Rover mission. The spectrometer uses laser desorption to ionize a Martian soil sample within an instrument internal clean zone maintained at ambient Martian pressure. A high-speed aperture valve transiently opens to allow ionized constituents, along with the ambient gas, to enter a vacuum cavity containing a linear ion trap mass spectrometer. The ambient clean zone and the vacuum cavity are connected via a few centimeter long aperture valve ion guide tube. In this paper, we present results from a recently completed numerical investigation of ion transport from the ion source across the ion guide. Specifically, we focus on collisional coupling between ions and the neutral molecules flowing into the vacuum cavity. The simulation domain contains the ambient region, and we consider the variation in ion conductance with ambient pressure. We also analyze the impact of a fixed potential bias applied to the aperture valve. Simulations are performed with a two-dimensional axisymmetric PIC / DSMC code Starfish. Numerical results are compared to experimental data.

Breida, Lubos↗

In-Flight Calibration of Hitomi Soft X-Ray Spectrometer. (1) Background

The X-Ray Spectrometer (XRS) instrument of Suzaku provided the first measurement of the non-X-ray background (NXB) of an X-ray calorimeter spectrometer, but the data set was limited. The Soft X-ray Spectrometer (SXS) instrument of Hitomi was able to provide a more detailed picture of X-ray calorimeter background, with more than 360 ks of data while pointed at the Earth, and a comparable amount of blank-sky data. These data are important not only for analyzing SXS science data, but also for categorizing the contributions to the NXB in X-ray calorimeters as a class. In this paper, we present the contributions to the SXS NXB, the types and effectiveness of the screening, the interaction of the screening with the broad-band redistribution, and the residual background spectrum as a function of magnetic cut-off rigidity. The orbit-averaged SXS NXB in the range 0.3-12 keV was 4 × 10(exp −2) counts s(exp −1) -sq cm. This very low background in combination with groundbreaking spectral resolution gave SXS unprecedented sensitivity to weak spectral lines.

Kilbourne, Caroline A.↗

Anomalous Uses of Mass Spectrometers at NASA

At the Harsh Environment Mass Spectrometer workshop we focus on bringing the Mass spectrometer to the sample because it's not practical to bring the samples back to the laboratories. However there are many NASA mass spectrometer applications where we bring the samples to the instrument. This presentation will discuss some of those applications that are ripe for innovative instrument development.

Loftin, Kathleen B.↗

Analytical Techniques for Retrieval of Atmospheric Composition with the Quadrupole Mass Spectrometer of the Sample Analysis at Mars Instrument Suite on Mars Science Laboratory

The Sample Analysis at Mars (SAM) instrument suite is the largest scientific payload on the Mars Science Laboratory (MSL) Curiosity rover, which landed in Mars׳ Gale Crater in August 2012. As a miniature geochemical laboratory, SAM is well-equipped to address multiple aspects of MSL׳s primary science goal, characterizing the potential past or present habitability of Gale Crater. Atmospheric measurements support this goal through compositional investigations relevant to martian climate evolution. SAM instruments include a quadrupole mass spectrometer, a tunable laser spectrometer, and a gas chromatograph that are used to analyze martian atmospheric gases as well as volatiles released by pyrolysis of solid surface materials (Mahaffy et al., 2012). This report presents analytical methods for retrieving the chemical and isotopic composition of Mars׳ atmosphere from measurements obtained with SAM׳s quadrupole mass spectrometer. It provides empirical calibration constants for computing volume mixing ratios of the most abundant atmospheric species and analytical functions to correct for instrument artifacts and to characterize measurement uncertainties. Finally, we discuss differences in volume mixing ratios of the martian atmosphere as determined by SAM (Mahaffy et al., 2013) and Viking (Owen et al., 1977, Oyama and Berdahl, 1977) from an analytical perspective. Although the focus of this paper is atmospheric observations, much of the material concerning corrections for instrumental effects also applies to reduction of data acquired with SAM from analysis of solid samples.

quadropole mass spectometer↗

Second-Generation Micro-Spec: A Compact Spectrometer for Far-Infrared and Submillimeter Space Missions

Micro-Spec is a direct-detection spectrometer which integrates all the components of a diffraction-grating spectrometer onto a ≈ 10-sq.cm chip through the use of superconducting microstrip transmission lines on a single- crystal silicon substrate. The second generation of Micro-Spec is being designed to operate with a spectral re- solution of at least 512 in the far-infrared and submillimeter (420–540 GHz, 714–555 μm) wavelength range, a band of interest for NASA's experiment for cryogenic large-aperture intensity mapping called EXCLAIM. EXCLAIM will be a balloon-borne telescope that is being designed to map the emission of redshifted carbon monoxide and singly-ionized carbon lines over a redshift range 0 < z < 3.5 and it will be the first demonstration of the Micro-Spec technology in a space-like environment. This work reviews the status of the Micro-Spec design for the EXCLAIM telescope, with emphasis on the spectrometer's two-dimensional diffractive region, through which light of different wavelengths is focused on kinetic inductance detectors along the instrument focal plane. An optimization process is used to generate a geometrical configuration of the diffractive region that satisfies l range and performance. An initial optical design optimized for n terms of geometric layout, spectral purity and efficiency.

Cataldo, Giuseppe↗

Uncertainties for Pre- and Post-Launch Radiometric Calibration of Imaging Spectrometers for Multi-Sensor Applications

An important aspect to using imaging spectrometer data is the radiometric characterization and calibration of the sensors and validation of their data products and doing so with error budgets with known traceability. The radiometric accuracy of a given sensor is important for demonstrating the expected quality of data from the sensor. Known traceability allows data from multiple sensors to be directly comparable as will become more important in the near future with the expected launches of multiple imaging spectrometers from multiple countries, agencies, and commercial entities. The current work describes the state of pre- and post-launch radiometric absolute and relative uncertainties and their role in harmonising on-orbit data. Examples of prelaunch uncertainties based on the calibration of EnMAP and the calibration planned for the CLARREO Pathfinder Mission are presented highlighting recent work in the area of detector-based approaches using tunable laser sources. Post-launch calibration approaches for Pathfinder, EnMAP, CHIME, and DESIS including traditional vicarious calibration methods and the challenges of working with commercial data are presented. The vicarious calibration discussion relies on the example of the recently-available RadCalNet data to describe typical methods and challenges that will be faced when harmonising data between imaging spectrometers as well as with multispectral sensors.

Thome, K.↗

The Marshall Grazing Incidence X-ray Spectrometer (MaGIXS) Solar Sounding Rocket Campaign – Calibration and Performance

The Marshall Grazing Incidence X-ray Spectrometer (MaGIXS) is a sounding rocket experiment that is designed to observe, for the first time, soft X-ray spectra of high-temperature, low-emission plasma of coronal structures spatially resolved along a narrow slit.MaGIXS observation involves a set of high temperature spectral lines in soft X-rays from 0.5 - 2.0 keV from an active region core,which will extend the DEM coverage from 3MK to 10MK constraining the slope of the DEM fall-off. The novel instrument designincludes a Wolter-I type telescope and a 3-optic grazing-incidence spectrometer. The spectrometer consists of a finite conjugatemirror pair and a blazed planar, varied line spaced grating, which disperses the rays on to a CCD and provides a high spatial andspectral resolution. Component level instrument testing, integration of the instrument and end-to-end X-ray calibration are carriedout using the X-ray and Cryogenic Facility (XRCF) at NASA Marshall Space Flight Center. MaGIXS is scheduled for launch in2021. We will present the results of X-ray calibration tests for MaGIXS and discuss the expected inflight performance throughdifferent solar observation scenarios.

P. S. Athiray↗

4-Pixel Heterodyne Receiver at 1.9 THz using a CMOS Spectrometer

We present results from a 4x1-pixel 1.9 THz heterodyne array for the astrophysically important [CII] spectral line. A 4-pixel multiplier chain at 1.9 THz, with a compact spacing of 5 mm, is used as an LO. Receiver performance is verified by y-factor measurements with measured sensitivities of 900 K. Finally, using a coherent source near the target frequency of 1.9 THz, we down convert to baseband and measure spectra with both an IBOB and a new CMOS-based spectrometer. The CMOS spectrometer provides several advantages over more traditional spectrometers because of its compact size and low power consumption. This receiver prototype is easily scalable to other frequencies and larger focal plane arrays. Furthermore, because of its compact configuration, it can be easily packaged for orbital or sub-orbital missions.

Mehdi, Imran↗

BIRCHES and Lunarcubes: Building the First Deep Space Cubesat Broadband IR Spectrometer

The Broadband InfraRed Compact High-resolution Exploration Spectrometer (BIRCHES), which will be described in detail here, is the compact broadband IR spectrometer of the Lunar Ice Cube mission. Lunar Ice Cube is one of 13 6U cubesats that will be deployed by EM1 in cislunar space, qualifying as lunarcubes. The LunarCube paradigm is a proposed approach for extending the affordable CubeSat standard to support access to deep space via cis-lunar/lunar missions. Because the lunar environment contains analogs of most solar system environments, the Moon is an ideal target for both testing critical deep space capabilities and understanding solar system formation and processes. Effectively, as developments are occurring in parallel, 13 prototype deep space cubesats are being flown for EM1. One useful outcome of this ‘experiment’ will be to determine to what extent it is possible to develop a lunarcube ‘bus’ with standardized interfaces to all subsystems using reasonable protocols for a variety of payloads. The lunar ice cube mission was developed as the test case in a GSFC R&D study to determine whether the cubesat paradigm could be applied to deep space, science requirements driven missions, and BIRCHES was its payload. Here, we present the design and describe the ongoing development, and testing, in the context of the challenges of using the cubesat paradigm to fly a broadband IR spectrometer in a 6U platform, including minimal funding and extensive need for leveraging existing assets and relationships on development, the foreshortened schedule for payload delivery on testing, and minimum bandwidth translating into simplified or canned operation.

Chapin, Peter↗

Spectral Properties of Dust on Asteroid (101955) Bennu with the OSIRIS-REx Visible and Infrared Spectrometer (OVIRS)

The Origins, Spectral Interpretation, Resource Identification, Security-Regolith Explorer (OSIRIS-REx) spacecraft successfully collected a sample of regolith from asteroid (101955) Bennu on October 20, 2020[1]. The Touch-and-Go (TAG) spacecraft maneuver used to collect the sample mobilized material, including very fine particles (dust),from up to ~1m in depth and ~10m in diameter from the point of contact with the asteroid [1,2].TAG created a dust plume that intercepted the spacecraft and accumulated on the instruments. As a result, all instruments show degradation in optical throughput, with the degree of degradation depending on their aperture size, orientation, and position on the spacecraft [1]. In this study, we analyzed OSIRIS-REx Visible and Infrared Spectrometer (OVIRS) from before and after TAG to assess the dust on the instrument with implications for Bennu’s dust composition and scattering properties, and future visible–near-infrared (VNIR)spectral observations with the OSIRIS-REx spacecraft. OVIRS is a point spectrometer that measures reflected light at VNIR wavelengths from 0.4 to 4.3 μm with a 4 mrad circular field of view(FOV) [3]. Previous observations with OVIRS revealed widespread hydrated minerals and carbon-bearing materials on Bennu [4,5]. A ~3 μm absorption feature is observed globally in OVIRS spectra, with a band position and depth that is consistent with Mg/Fe phyllosilicates and suggests a similar degree of aqueous alteration to that experienced by some carbonaceous chondrite meteorites[4,6]. A series of weak (<5%) VNIR spectral features, potentially associated with hydrated phyllosilicates and iron oxides, are also found in OVIRS spectra (Fig. 1), though not typically observed in meteorite spectra [7]. OSIRIS-REx Thermal Emission Spectrometer (OTES) spectra are consistent with a very thin accumulation (a few to ~ten microns) of fine particles (<~65–100 microns in size)across the surface of Bennu, and particularly on the roughest boulders, an interpretation that is supported by the dust plume seen during TAG [1,8]. An analysis of TAG contamination on the OTES optics revealed a 15% decrease in throughput, and OTES observations of space with and without that contamination allow a recreation of the thermal infrared spectrum [1]. The spectrum of the contamination lacks volume scattering features and exhibits a stronger Mg-OH absorption (~16.5 μm) than average Bennu, suggesting a Mg-rich phyllosilicate composition [1,6]. Here we present the first compositional analysis of Bennu dust at VNIR wavelengths by analyzing the contaminant on OVIRS.

H H Kaplan↗

Recent Developments in Tolerancing Methods for Imaging Spectrometers

We discuss detailed tolerancing methods developed for imaging spectrometers at NASA Jet Propulsion Laboratory, California Institute of Technology using the Earth Surface Mineral Dust Source Investigation (EMIT) imaging spectrometer as an illustrative example. We tolerance five metrics simultaneously: along-track response function, cross-track response function, spectral response function, spectral centroid uniformity, and spatial centroid uniformity. A method to calculate tolerancing sensitivities for each metric directly, a method to statistically combine Monte Carlo files from multiple tolerancing runs, and an example summary error budgets that communicate the key and driving tolerances for each metric are discussed. These methods facilitate rapid and semi-automated assessment of the predicted performance of imaging spectrometer systems from design through to assembly and launch life cycle, using metrics that are directly relevant to the extraction of accurate spectroscopic data from these instruments.

Mouroulis, Pantazis↗

DSN Radio Astronomy Spectrometer

The Deep Space Network (DSN) enables NASA to communicate with its deep space spacecraft. By virtue of its large antennas, the DSN can be used as a powerful instrument for radio astronomy. In particular, Deep Space Station (DSS) 43, the 70 m antenna at the Canberra Deep Space Communications Complex (CDSCC) has a K-band radio astronomy system covering a 10 GHz bandwidth at 17 to 27 GHz. This spectral range covers a number of atomic and molecular lines, produced in a rich variety of interstellar gas conditions. A new high-resolution spectrometer was deployed at CDSCC in November 2019 and connected to the K-band downconverter. The system has two different firmware modes: 1) Using a 65k-pt FFT to provide 32,768 spectral channels at ~30.5 kHz (0.45 km/s velocity resolution) and 2) Using a 16k-pt polyphase filterbank (PFB) to provide 8,192 spectral channels with ~122 kHz resolution (1.8 km/s velocity resolution). Previous work extensively described the spectrometer system. In this paper we present added functionality and updates to the commissioned spectrometer. The changes include developments in system timing, metadata, firmware and data products.

Bradford, Brian↗

Updated assessment of TROPOMI NO2 and HCHO columns using airborne spectrometers during the MOOSE and TRACER-AQ field campaigns

Airborne spectrometer data offers the opportunity to evaluate satellite product performance without the impact of subpixel heterogeneity between the different satellite and ground-based measurement footprints. Previous measurements during the Long Island Sound Tropospheric Ozone Study were used to evaluate TROPOMI’s v1.3 NO2 product and found very strong relationships (r2=0.96) between the airborne spectrometer and TROPOMI with a systematic low bias mostly attributed to the coarse a priori profile assumption within the standard TROPOMI retrieval. This presentation will update that analysis using the most up-to-date version 2 TROPOMI NO2 product as well as expand analysis to the HCHO product. In summer 2021, NASA GeoCAPE Airborne Simulator (GCAS) collected measurements over southeast Michigan/western Ontario for the Michigan-Ontario Ozone Source Experiment (MOOSE) and Houston, Texas during the TRacking Aerosol Convection ExpeRiment – Air Quality (TRACER-AQ). Flight strategies for both deployments included repeated systematic sampling over common areas of interest coinciding with TROPOMI. During these flights, GCAS NO2 tropospheric columns are available at 250 m x 560 m resolution. Preliminary evaluation of GCAS NO2 retrievals with Pandora spectrometer data in Houston, Texas (3 sites) shows a median percent difference of 1.4% with an interquartile range of -15.5-14.9% (r2=0.72). Column HCHO was also retrieved at a slightly coarser resolution in Houston, Texas (750 m x 1680 m) showing distinct spatial patterns associated with secondary production through the oxidation of VOCs downwind of industrial facilities. Comparison to Pandora HCHO showed a low bias of ~25% (r2=0.29) with further investigation needed to identify the cause for this bias. This presentation will share how the GCAS/Pandora/TROPOMI NO2 and HCHO intercompare and will also extend analysis toward thinking about how these assets will contribute to the validation of future geostationary observations.

Laura Judd↗