Search NASA⌕ Search

SEARCH · Search NASA

Results for “Spectrometers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Analytical Assessment of Impurities Found in Process Gases using the InfiTOF, a High Resolution, Low Mass, Variable Time-of-Flight Mass Spectrometer

The JEOL InfiToF is a high-resolution, low mass (HRLM) mass spectrometer (MS) with the application potential to meet analytical needs for tritium handling systems, such as those at the Savannah River Tritium Facilities (SRTE) and those used in fusion research. The Service Level Agreement (SLA) #144 line 27 “InfiTOF R&D” has concluded its first year of efforts under Tritium Recycle and Renewal. The project goals for FY22 were: (1) Production of a finalized modification list for tritium hardened components in the InfiTOF, (2) perform an assessment on impurity gases commonly found in process gases from Tritium Facilities and (3) begin developing a set of standardized work instructions that will be used as a basis for operations on the InfiTOF.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Milestone report for MRT 8504: Commission EXAFS spectrometer with spectral range of 17.95-18.6 keV design to obtain EXAFS data for Pu L shell experiments

This milestone describes the development and fielding of EXAFS Phase II spectrometer designed to provide high quality (SNR>=5) EXAFS spectra for Plutonium measurements at the National Ignition facility (NIF). Benefits: the EXAFS data will be used by the High Energy Density (HED) Physics and more specifically the Focused Material Science program to measure the thermal state of compressed materials with good temperature sensitivity (~100-1000 Kelvin). Data with good signal to noise ratio (SNR>=5) and good spectral resolution allows the FMS program to fill a gap in diagnosing temperature to completely constrain material properties for weapon physics and Stockpile Stewardship applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Continued Evaluation of the Use of a Raman Spectrometer for H-Canyon Dissolver Monitoring

Remote monitoring of dissolver activities in H-Canyon can help operators avoid delays associated with excessive levels of fuel fragments remaining after a run. SRNL has proposed that effective monitoring can be achieved by using a Raman spectrometer to measure NO 2 concentrations in the offgas stream sampled from the facility stack. Prior work (SRNL-STI-2021-00451) measuring the offgas from one dissolution batch of High Flux Isotope Reactor (HFIR) fuel suggested a relationship between %NO 2 levels and fragment height. Herein, we report the results of monitoring and analysis of the dissolution of four batches of Material Test Reactor (MTR) fuel. A rigorous quantitative relationship between %NO 2 measurements and fragment heights could not be established, due to high uncertainties associated with both measurements. Uncertainties with gas measurements are associated with the %NO 2 levels in the offgas being close to the detection limit for the analyzer. Alternative gas measurement strategies are discussed which could improve sensitivity and reduce uncertainty. Limitations to the precision of the probe measurements are also discussed. It is also noted that the offgas is an average of the products from simultaneous dissolution of elements in multiple wells. Detection of a high fragment height level in an individual well may be hindered by low levels in other wells.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Characterization of the Multi-Coincident Bismuth Germanate Oxide Spectrometer at the Nuclear Counting Facility

A multi-detector γ-ray spectroscopy system including 3 high-purity germanium (HPGe) detectors has been developed at the Nuclear Counting Facility at Lawrence Livermore National Laboratory. This system operates not only in conventional singles γ-ray detection mode but also incorporates features like coincidence and anti-coincidence techniques. These advanced detection modes can significantly enhance the system’s sensitivity, making it a powerful tool for isotope identification and quantification, especially for complex samples with high background and overlapping peaks. In this re port, we present a comprehensive performance characterization of the Multi-Coincident Bismuth Oxide Spectrometer (MCBOS) using a variety of sample types, including 60 Co, 48 Sc, and mixed fission product samples. Each sample provides unique tests for the MCBOS capabilities. Additionally, a GEANT4 model of the MCBOS has been generated to aid with the characterization of the system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improved Chopper System for a Direct Geometry Spectrometer at the Second Target Station

This report describes a chopper cascade suitable for a cold direct geometry spectrometer at a pulsed neutron source with a low repetition rate such as the Second Target Station (STS) currently being planned at Oak Ridge National Laboratory (ORNL). The chopper cascade offers the following capabilities: selection of a variable number of pulses per frame (flexible pulse suppression), selection of pulses with increasing timing separation within one frame, and an increasing pulse width ∆t within one frame, in order to achieve an even energy resolution over several pulses at different wavelengths across the frame.

43 PARTICLE ACCELERATORS↗

Testing, Calibration, and UxS Integration of the Kromek GR1 Plus CZT Gamma Spectrometer

Collecting radiation measurements can be a hazardous task, especially in the presence of highly active sources. Various scenarios necessitate source search, classification, and quantification, often with limited or no a priori information. Activities such as disaster mitigation, emergency response, environmental monitoring, and site remediation may involve dangerous radioactive sources. In these situations, there is a pressing need for remote monitoring capabilities that protect human operators from potential harm and enhance adherence to the principle of “As Low as Reasonably Achievable” (ALARA) for radiation doses. The first step toward achieving remote radiation measurement capabilities is the remote operation of a radiation sensor. Once this milestone is reached, the next challenge is to integrate this remote sensing capability into suitable actuation agents, collectively referred to as uncrewed systems (UxS). These systems include familiar platforms such as robotic quadrupeds, aerial multirotor vehicles, and ground vehicles, any of which may be teleoperated, act autonomously, or utilize a combination of both. A critical factor in achieving remote radiation sensing is the availability of data from the appropriate sensor. Many commercially available radiation sensors have closed-source documentation for their communication protocols. Typical end-user products are often self-contained, handheld devices designed for manual measurement scenarios. While there are commercial off-the-shelf (COTS) integrations of radiation sensors with UxS available for purchase, these solutions are typically tailored for specific use cases and may not meet the requirements of different applications. This paper discusses efforts to remotely acquire radiation measurements from a small form-factor CZT gamma spectrometer. Sandia National Laboratories has successfully demonstrated the initial capability to integrate low size, weight, and power (SWaP) gamma spectroscopy into various UxS, alongside co-located GPS data logging and sensor calibration and qualification. With remote gamma spectroscopy achieved, the stage is set for UxS integration of this capability.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Network of Modified Portable Optical Particle Spectrometers Instrument Handbook

The U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility’s portable optical particle spectrometer (POPS) network (Figure 1) provides an aerosol size distribution spectrum from 150 nm to 5 μm in 16 logarithmically spaced bins. The data emanating from this network of up to four matching POPS in weatherproof enclosures comprises one-minute averages of the aerosol size and number spectrum and the co-located temperature and relative humidity. The total particle concentration and sample flow rate are also provided. The sample stream is not dried before its measurement. Two size spectra are provided: the default size distribution corresponds to the calibration using polystyrene latex spheres (PSL), while the second size distribution corresponds to the calibration using size-selected dry ammonium sulfate aerosol. The principal scientific application of the data provided by the ARM POPS is to determine the aerosol size distribution across a region in three disparate locations – the size distribution is broadly relevant to studies of pollution and of conditions in the boundary layer. A high particle concentration can be an indicator of unhealthy levels of pollution; the dispersion of particles in the atmosphere is a predictor of long-range visibility; and particles serve as collectors of condensing gases including water vapor, and thus are a factor in the formation and properties of fogs and clouds, and in the initiation of precipitation.

54 ENVIRONMENTAL SCIENCES↗

In-Field Alpha Spectrometer Development FY2022 Mid-Year Report

In response to needs identified by the International Atomic Energy Agency (IAEA), Idaho National Laboratory (INL) has developed an In-Field Alpha Spectrometer (IFAS) to allow IAEA safeguards inspectors to collect samples of uranium hexafluoride (UF 6 ) at processing facilities, to perform field assessments to verify uranium enrichment. For sample collection, the IFAS method uses Single-Use Destructive Assay (SUDA) samplers, developed at Pacific Northwest National Laboratory (PNNL), which contain thin zeolite coatings that trap UF6 gas and convert it to the safer, more stable form uranyl fluoride (as a dihydrate, UO 2 F 2 ·2H 2 O). For alpha spectrometry, the IFAS instrument employs a large area silicon semiconductor transducer to detect and record alpha particle energy-deposition events. Over the course of this project INL, PNNL, Oak Ridge National Laboratory worked to optimize the SUDA sample design for alpha spectrometry, to optimize processes for manufacturing, loading, and shipping SUDA samples, and to allow the measurement of loaded SUDA samples. In fiscal year (FY) 2022 INL has bene investigating the reproducibility and measurement precision of IFAS measurements and the associated determination of uranium enrichment.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Autonomous Ion Mass Spectrometer Sentry (AIMSS)

Satellite measurements of plasma density and temperature help predict the intensity of geomagnetic storms, which can impact satellites, communications, and power systems. Accurate forecasting requires knowledge of plasma composition. However, typical orbital mass spectrometers have difficulty distinguishing between nitrogen (N+) and oxygen (O+) ions due to their similar masses. This limitation makes it difficult to validate modern space weather models, which depend on accurate knowledge of ion composition in near-Earth space. N+ and O+ ions behave differently in space due to differences in their origin, transport, and loss mechanisms. Improving our ability to distinguish between these ions is critical for understanding and predicting space weather.

47 OTHER INSTRUMENTATION↗

A High-Magnetic-Field Polarized 3He Target for JLab's CLAS12 Spectrometer

We are developing a polarized 3He target for use in high luminosity electron scattering experiments within the high magnetic field environment of Jefferson Lab's CLAS12 spectrometer. By combining recent advancements in metastability exchange optical pumping (MEOP) of 3He with cryogenic, double-cell target methods as used for the MIT-Bates 88-02 experiment, a target with polarization and gas density comparable to traditional, low-field polarized 3He targets can be reached within high magnetic field environments. We have begun polarizing sealed 3He cells at fields up to 5 T at Jefferson Lab, and are preparing for our first tests exploring polarization performance versus magnetic field and gas pressure in a single cell before we move to the construction of a full, cryogenic, double-cell prototype target. A key focus of our research is the determination of polarization relaxation under the irradiation of an ionizing particle beam within high magnetic fields.

Maxwell, James↗

Improvements in the Sample Space for the Backscattering Silicon Spectrometer (BASIS)

The increase in neutron flux at the Oak Ridge National Laboratory (ORNL) Spallation Neutron Source (SNS), currently operating at 2.0 MW proton beam power, has created new opportunities for higher-throughput neutron scattering experiments while also increasing the importance of minimizing background scattering and optimizing sample-environment operations. To address these challenges on the Backscattering Silicon Spectrometer (BA-SIS), several upgrades were developed and evaluated, including boron carbide (B₄C) masking for flat-plate sample containers, multi-cell sample holders used with a vertically translating sample stick, and an automated helium pump and purge (HPP) system for closed-cycle refrigerators. Neutron diffraction measurements demonstrate that B₄C masks reduce background scattering by 49–67%, outperforming both borated aluminum and boron nitride masks while introducing no additional Bragg reflections within the instrument’s accessible Q-range. Commissioning tests of a double-cell flat-plate sample contain-er showed no measurable crosstalk between adjacent sample compartments and con-firmed stable thermal performance, enabling multiple samples to be measured without re-peated temperature cycling. In addition, the automated HPP system provided reproducible sample-space gas handling with approximately ±1 mbar precision while reducing the need for operator intervention and supporting remote operation. Together, these developments improve signal-to-noise performance, increase experimental throughput, and enhance operational efficiency at BASIS, supporting the instrument’s continued operation under higher neutron flux conditions.

Jalarvo, Niina [ORNL] (ORCID:0000000306446866)↗

Nanoscale Three-Dimensional Imaging of Integrated Circuits Using a Scanning Electron Microscope and Transition-Edge Sensor Spectrometer

X-ray nanotomography is a powerful tool for the characterization of nanoscale materials and structures, but it is difficult to implement due to the competing requirements of X-ray flux and spot size. Due to this constraint, state-of-the-art nanotomography is predominantly performed at large synchrotron facilities. We present a laboratory-scale nanotomography instrument that achieves nanoscale spatial resolution while addressing the limitations of conventional tomography tools. The instrument combines the electron beam of a scanning electron microscope (SEM) with the precise, broadband X-ray detection of a superconducting transition-edge sensor (TES) microcalorimeter. The electron beam generates a highly focused X-ray spot on a metal target held micrometers away from the sample of interest, while the TES spectrometer isolates target photons with a high signal-to-noise ratio. This combination of a focused X-ray spot, energy-resolved X-ray detection, and unique system geometry enables nanoscale, element-specific X-ray imaging in a compact footprint. The proof of concept for this approach to X-ray nanotomography is demonstrated by imaging 160 nm features in three dimensions in six layers of a Cu-SiO 2 integrated circuit, and a path toward finer resolution and enhanced imaging capabilities is discussed.

47 OTHER INSTRUMENTATION↗

Measurement report: The Fifth International Workshop on Ice Nucleation phase 1 (FIN-01): intercomparison of single-particle mass spectrometers

Knowledge of the chemical composition and mixing state of aerosols at a single-particle level is critical for gaining insights into atmospheric processes. One common tool to make these measurements is single-particle mass spectrometry. There remains a need to compare the performance of different single-particle mass spectrometers (SPMSs). An intercomparison of SPMSs was conducted at the Aerosol Interaction and Dynamics in the Atmosphere (AIDA) chamber at the Karlsruhe Institute of Technology (KIT) in November 2014, as part of the first phase of the Fifth International Workshop on Ice Nucleation (FIN-01). In this paper we compare size distributions and mass spectra of atmospherically relevant particle types measured by five SPMSs. These include different minerals, desert and soil dusts, soot, bioaerosol (Snomax; protein granule), secondary organic aerosol (SOA), and SOA-coated mineral particles. Most SPMSs reported similar vacuum aerodynamic diameter (d va ) within typical instrumental ranges from ~100–200 nm (lower limit) to ~2–3 µm (upper limit). In general, all SPMSs exhibited a wide dynamic range (up to ~10 3 ) and high signal-to-noise ratio (up to ~10 4 ) in mass spectra. Common spectral features with small diversities in mass spectra were found with high average Pearson's correlation coefficients, i.e., for average positive spectra r avg-pos =0.74 ± 0.12 and average negative spectra r avg-neg =0.67 ± 0.22. We found that instrument-specific detection efficiency (DE) was more dependent on particle size than particle type, and particle identification favored the use of bipolar, rather than monopolar, instruments. Particle classification from “blind experiments” showed that all instruments differentiated SOA, soot, and soil dust and detected subtle changes in the particle internal mixing but had difficulties differentiating among specific mineral types and dusts. This study helps to further understand the capabilities and limitations of the single-particle mass spectrometry technique in general and the specific performance of the instrument in characterizing atmospheric aerosol particles.

54 ENVIRONMENTAL SCIENCES↗

Regularized inversion of aerosol hygroscopic growth factor probability density function: application to humidity-controlled fast integrated mobility spectrometer measurements

Abstract. Aerosol hygroscopic growth plays an important role in atmospheric particle chemistry and the effects of aerosol on radiation and hence climate. The hygroscopic growth is often characterized by a growth factor probability density function (GF-PDF), where the growth factor is defined as the ratio of the particle size at a specified relative humidity to its dry size. Parametric, least-squares methods are the most widely used algorithms for inverting the GF-PDF from measurements of the humidified tandem differential mobility analyzer (HTDMA) and have been recently applied to the GF-PDF inversion from measurements of the humidity-controlled fast integrated mobility spectrometer (HFIMS). However, these least-squares methods suffer from noise amplification due to the lack of regularization in solving the ill-posed problem, resulting in significant fluctuations in the retrieved GF-PDF and even occasional failures of convergence. In this study, we introduce nonparametric, regularized methods to invert the aerosol GF-PDF and apply them to HFIMS measurements. Based on the HFIMS kernel function, the forward convolution is transformed into a matrix-based form, which facilitates the application of the nonparametric inversion methods with regularizations, including Tikhonov regularization and Twomey's iterative regularization. Inversions of the GF-PDF using the nonparameteric methods with regularization are demonstrated using HFIMS measurements simulated from representative GF-PDFs of ambient aerosols. The characteristics of reconstructed GF-PDFs resulting from different inversion methods, including previously developed least-squares methods, are quantitatively compared. The result shows that Twomey's method generally outperforms other inversion methods. The capabilities of Twomey's method in reconstructing the pre-defined GF-PDFs and recovering the mode parameters are validated.

54 ENVIRONMENTAL SCIENCES↗

MOSAiC-Colorado State University Ice Spectrometer

This data set contains atmospheric ice nucleating particle (INP) measurements, using Colorado State University&rsquo;s (CSU) Ice Spectrometer (IS), of filter collections taken at the U.S. DOE ARM AMF2 site onboard the R/V Polarstern P-deck during the Multidisciplinary Drifting Observatory for the Study of Arctic Climate (MOSAiC) field campaign. Samples were collected from October 27, 2019 to September 24, 2020. A filter sampler was mounted approximately 15 m above ground level on a railing in proximity to (and approximately 3 m below) the Aerosol Observation System (AOS) inlet. Single-use filter units open to the atmosphere were pre-cleaned and pre-loaded with 47-mm diameter Nuclepore polycarbonate (0.2 &micro;m pore-diameter) filters. Filters were typically drawn for a three-day period, with an average volume of air filtered of 87,000 standard liters. Total volumes were calculated through recorded daily flow rates using a mass flow meter (TSI). After collection, filters were stored and transported frozen until analysis using CSU&rsquo;s IS instrument (McCluskey et al., 2018). Aerosol particles were first re-suspended in 8 mL of 0.1 &micro;m-filtered deionized (DI) water. Aliquots of each suspension, and corresponding 11-fold dilutions, were dispensed into polymerase chain reaction (PCR) trays and placed into the aluminum blocks of the IS. Samples were cooled at approximately 0.33 &deg;C min -1 and freezing detected optically with corresponding temperatures recorded. Cumulative INP concentrations were determined through calculating the number of INPs per mL of suspension (Vali, 1971) and converting to concentration per standard L of air by accounting for the proportion of liquid used and volume of air collected. All samples were corrected for the number of INPs on the average of four field blanks (cleaned, handled, transported, and analyzed in the same way without air flow). Two-tailed, 95% confidence intervals for binomial sampling are provided (Agresti and Coull, 1998). Select samples were also heat treated (95 &deg;C for 20 min) to denature and deactivate biological INPs present and digested in 10% H 2 O 2 at 95 &deg;C under UV-B for 20 min to remove any organic carbon INPs. Agresti, A, and BA Coull. 1998. "Approximate is better than &ldquo;exact&rdquo; for interval estimation of binomial proportions." American Statistics 52: 119&ndash;126. https://doi.org/10.2307/2685469 McCluskey, CS, J Ovadnevaite, M Rinaldi, J Atkinson, F Belosi, D Ceburnis, &hellip; and PJ DeMott. 2018. "Marine and Terrestrial Organic Ice-Nucleating Particles in Pristine Marine to Continentally Influenced Northeast Atlantic Air Masses." Journal of Geophysical Research: Atmospheres 123 (11): 6196&ndash;6212, https://doi.org/10.1029/2017JD028033 Vali, G. 1971. "Quantitative Evaluation of Experimental Results and the Heterogeneous Freezing Nucleation of Supercooled Liquids." Journal of the Atmospheric Sciences 28: 402-209. https://doi.org/10.1175/1520-0469(1971)028<0402:QEOERA>2.0.CO;2

54 ENVIRONMENTAL SCIENCES↗

EPCAPE-PT-LANL Measurements: Soot Particle Aerosol Mass Spectrometer

Coastal cities offer a unique environment for studying aerosol-cloud interactions and the effects of urban emissions on cloud properties. As part of the Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE), the Partitioning Thrust by Los Alamos National Laboratory (EPCAPE-PT-LANL) was conducted. Our campaign focused on measuring the optical and chemical properties of aerosols and their interactions within marine stratocumulus clouds in La Jolla, California. EPCAPE-PT-LANL enhances the primary goals of EPCAPE through innovative observations of vapor-phase transitions between aerosols and cloud droplets, the impact of black carbon on aerosol-cloud dynamics, and the effects of cloud processing on aerosol optical properties. Instrument: Soot particle-Aerosol Mass Spectrometer. (Aerodyne Inc.) Header: - Organic_GCVIoff[ug/m3]: Concentration of organic compounds measured via the Main Inlet (out-of-cloud) in micrograms per cubic meter. - Nitrate_GCVIoff[ug/m3]: Concentration of nitrate measured via the Main Inlet (out-of-cloud) in micrograms per cubic meter. - Sulfate_GCVIoff[ug/m3]: Concentration of sulfate measured via the Main Inlet (out-of-cloud) in micrograms per cubic meter. - Chloride_GCVIoff[ug/m3]: Concentration of chloride measured via the Main Inlet (out-of-cloud) in micrograms per cubic meter. - Ammonium_GCVIoff[ug/m3]: Concentration of ammonium via the Main Inlet (out-of-cloud) in micrograms per cubic meter. - Organic_GCVIon[ug/m3]: Concentration of organic compounds measured in-cloud via CVI in micrograms per cubic meter. - Nitrate_GCVIon[ug/m3]: Concentration of nitrate measured in-cloud via CVI in micrograms per cubic meter. - Sulfate_GCVIon[ug/m3]: Concentration of sulfate measured in-cloud via CVI in micrograms per cubic meter. - Chloride_GCVIon[ug/m3]: Concentration of chloride measured in-cloud via CVI in micrograms per cubic meter. - Ammonium_GCVIon[ug/m3]: Concentration of ammonium measured in-cloud via CVI in micrograms per cubic meter. - CVI_Flag[bool]: A boolean flag indicating whether the CVI was active (true) or inactive (false) during the measurement.

54 ENVIRONMENTAL SCIENCES↗