Search NASA⌕ Search

SEARCH · Search NASA

Results for “Storage Futures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Genesis Spacecraft Science Canister Preliminary Inspection and Cleaning

The Genesis science canister is an aluminum cylinder (75 cm diameter and 35 cm tall) hinged at the mid-line for opening. This canister was cleaned and assembled in an ISO level 4 (Class 10) clean room at Johnson Space Center (JSC) prior to launch. The clean solar collectors were installed and the canister closed in the cleanroom to preserve collector cleanliness. The canister remained closed until opened on station at Earth-Sun L1 for solar wind collection. At the conclusion of collection, the canister was again closed to preserve collector cleanliness during Earth return and re-entry. Upon impacting the dry Utah lakebed at 300 kph the science canister integrity was breached. The canister was returned to JSC. The canister shell was briefly examined, imaged, gently cleaned of dust and packaged for storage in anticipation of future detailed examination. The condition of the science canister shell noted during this brief examination is presented here. The canister interior components were packaged and stored without imaging due to time constraints.

Hittle, J. D.↗

Large Scale Production of Densified Hydrogen to the Triple Point and Below

Recent demonstration of advanced liquid hydrogen storage techniques using Integrated Refrigeration and Storage technology at NASA Kennedy Space Center led to the production of large quantities of densified liquid and slush hydrogen in a 125,000 L tank. Production of densified hydrogen was performed at three different liquid levels and LH2 temperatures were measured by twenty silicon diode temperature sensors. Overall densification performance of the system is explored, and solid mass fractions are calculated. Experimental data reveal hydrogen temperatures dropped well below the triple point during testing, and were continuing to trend downward prior to system shutdown. Sub-triple point temperatures were seen to evolve in a time dependent manner along the length of the horizontal, cylindrical vessel. The phenomenon, observed at two fill levels, is detailed herein. The implications of using IRAS for energy storage, propellant densification, and future cryofuel systems are discussed.

IRAS↗

Large Scale Production of Densified Hydrogen Using Integrated Refrigeration and Storage

Recent demonstration of advanced liquid hydrogen storage techniques using Integrated Refrigeration and Storage (IRAS) technology at NASA Kennedy Space Center led to the production of large quantities of solid densified liquid and slush hydrogen in a 125,000 L tank. Production of densified hydrogen was performed at three different liquid levels and LH2 temperatures were measured by twenty silicon diode temperature sensors. System energy balances and solid mass fractions are calculated. Experimental data reveal hydrogen temperatures dropped well below the triple point during testing (up to 1 K), and were continuing to trend downward prior to system shutdown. Sub-triple point temperatures were seen to evolve in a time dependent manner along the length of the horizontal, cylindrical vessel. Twenty silicon diode temperature sensors were recorded over approximately one month for testing at two different fill levels (33 67). The phenomenon, observed at both two fill levels, is described and presented detailed and explained herein., and The implications of using IRAS for energy storage, propellant densification, and future cryofuel systems are discussed.

Notardonato, William U.↗

Large Scale Production of Densified Hydrogen to the Triple Point and Below

Recent demonstration of advanced liquid hydrogen storage techniques using Integrated Refrigeration and Storage technology at NASA Kennedy Space Center led to the production of large quantities of densified liquid and slush hydrogen in a 125,000 L tank. Production of densified hydrogen was performed at three different liquid levels and LH2 temperatures were measured by twenty silicon diode temperature sensors. Overall densification performance of the system is explored, and solid mass fractions are calculated. Experimental data reveal hydrogen temperatures dropped well below the triple point during testing, and were continuing to trend downward prior to system shutdown. Sub-triple point temperatures were seen to evolve in a time dependent manner along the length of the horizontal, cylindrical vessel. The phenomenon, observed at two fill levels, is detailed herein. The implications of using IRAS for energy storage, propellant densification, and future cryofuel systems are discussed.

Hydrogen↗

Lunar Equator Regenerative Fuel Cell System Efficiency Analysis

It is expected that future NASA mission energy storage requirements can be adequately met by regenerative fuel cells (RFCs). Aerospace RFCs are likely to package proton exchange membrane electrochemical conversion devices based on hydrogen, oxygen, and water. To optimize system designs and direct further development, the most useful system metric is round-trip efficiency (RTE). Improving RTE generally increases specific energy and reduces system mass. The following analysis models the impact of several factors on RTE for RFCs scaling from 0.1 to 50 kW. The analysis demonstrates that higher electrolyzer (EZ) operational pressure most negatively impacts both RFC RTE and specific energy. Reactant storage heating and power management losses are significant for RFCs of any scale, but solenoid valve power becomes a noticeable parasitic load for smaller RFCs. Spherical gas storage vessels benefit RTE by only 2 to 4 percentage points but increase specific energy by ~50 percent. Cryogenic reactant storage is shown to depress RTE to below 15 percent in all cases. For a given RFC scale, there is an RTE benefit to specifying larger EZs and recharging at higher rates—if the RFC can be coupled with a corresponding power source. Although fuel cell (FC) operation is less impactful on RTE than EZ factors, efficiency is maximized by sizing the FCs relatively large and keeping current density low. RFC design is a balance of many interrelated factors, but this analysis provides a starting point for difficult decisions that must be made when designing a lunar equator RFC.

regenerative fuel cell↗

Lunar South Pole Regenerative Fuel Cell System Efficiency Analysis

It is expected that future NASA mission energy storage needs can be adequately met by regenerative fuel cells (RFCs). Aerospace RFCs package proton exchange membrane (PEM) electrochemical conversion devices based on hydrogen, oxygen, and water. To optimize system designs and direct further development, the most useful system metric is round-trip efficiency (RTE). Improving RTE generally increases specific energy and reduces system mass. The following analysis models the impact of several factors on RTE for RFCs at the lunar south pole scaling from 0.1 kW to 50 kW. The analysis demonstrates that higher electrolyzer operational pressure most negatively impacts both RFC RTE and specific energy. Optimal electrolyzer membrane thickness is evaluated as a function of operational current density and pressure. Reactant storage heating and power management losses are significant for RFCs of any scale but are reduced in impact at the south pole compared to colder equator applications. Solenoid valve power remains a noticeable parasitic load for smaller RFCs. Larger electrolyzers enable higher peak theoretical efficiencies when recharging at higher rates, if the RFC can be coupled with a corresponding higher power source. RFC design is a compromise of many interrelated factors, but this analysis provides a starting point for difficult decisions that must be made when designing a lunar south pole RFC.

regenerative fuel cell↗

Validation of CFD Model Prediction of Flow Boiling Regime Transitions during LN2 Line Chilldown

Propellant storage and transfer during future long-duration missions will involve fuel depot operations in which a donor depot tank is used to fill a receiver spacecraft tank with a cryogenic propellant. Prior to the on-Orbit filling operation both the receiver tank and the transfer line must be cooled. The line chilldown process involves transition between boiling regimes in microgravity that will be quite different from their 1g ground-based counterparts. Since the cryogenic propellant itself will be used to perform the chilldown process, the time constants to cool the wall and the amount of fuel that will be used become important design considerations. In this light, the focus of the present work is to understand the flow boiling characteristics of a cryogenic fluid, namely, liquid nitrogen, during the chill-down of a transfer line using CFD modelling and simulations. The cryogenic chill-down process involves different flow boiling regimes: film boiling, transition boiling and nucleate boiling. The prediction of transition between these regimes in a CFD framework is new and challenging. The present work addresses this challenge by employing a volume-of-fluid (VOF) based methodology with Lee phase change model to predict the film boiling regime of the chill-down process in ANSYS Fluent®. The transition and nucleate boiling regimes are predicted by incorporating a sub-grid model developed by Craft Tech that accounts for bubble nucleation, growth, shedding frequency, and departure diameter. The sub-grid model is implemented into Fluent via a user-defined function for wall-fluid heat flux calculations. The sub-grid model is similar in formulation to the well-known Rensselaer Polytechnic Institute (RPI) boiling model. The model constants are tested for different operating conditions and designated values are reported. The CFD model is validated against published experimental data for liquid nitrogen chill-down of a heated stainless-steel pipe in 1g. Predicted results showing good agreement of wall temperature, rewetting temperature, and transition between film and nucleate boiling with the experimental measurements are presented and discussed.

Boiling regimes↗

Predictions of Line Chilldown Boiling Regime Transitions by a Coupled CFD-Sub-Grid Boiling Model Validated against 1G LN2 Experiments

Propellant storage and transfer during future long-duration missions will involve fuel depot operations in which a donor depot tank is used to fill a receiver spacecraft tank with a cryogenic propellant. Prior to the on-Orbit filling operation both the receiver tank and the transfer line must be cooled. The line chilldown process involves transition between boiling regimes in microgravity that will be quite different from their 1g ground-based counterparts. Since the cryogenic propellant itself will be used to perform the chilldown process, the time constants to cool the wall and the amount of fuel that will be used become important design considerations. In this light, the focus of the present work is to capture the flow boiling characteristics of a cryogenic fluid, namely, liquid nitrogen, during the chill-down of a transfer line using CFD modelling and simulations. The cryogenic chill-down process involves different flow boiling regimes: film boiling, transition boiling and nucleate boiling. The prediction of transition between these regimes in a CFD framework is new and challenging. The present work addresses this challenge by employing a volume-of-fluid (VOF) based methodology with Lee phase change model to predict the film boiling regime of the chill-down process in ANSYS Fluent®. The transition and nucleate boiling regimes are predicted by incorporating a sub-grid model that accounts for bubble nucleation, growth, shedding frequency, and departure diameter. The sub-grid model is implemented into Fluent via a user-defined function for wall-fluid heat flux calculations. The sub-grid model is similar in formulation to the well-known Rensselaer Polytechnic Institute (RPI) boiling model. The CFD model is validated against published experimental data for liquid nitrogen chill-down of a heated stainless-steel pipe in 1g. Predicted results shows good agreement of wall temperature, rewetting temperature, and transition between film and nucleate boiling with the experimental measurements for several different LN2 flowrates in the vertical orientation. The strengths and weaknesses of this modeling approach are presented and discussed.

Cryogenic Fluid Management↗

(Paper) TRIPWIRE: Multi-modal Distributed Sensing For Repository Verification

Underground geological repositories for storing used nuclear fuel are being planned and developed around the world. Research is being performed to understand technical aspects of sealing entombed materials and underground repositories to ensure the radiological and nuclear materials remain contained. To support safeguards verification for these facilities research at Idaho National Laboratory (INL) is underway to develop and demonstrate a multi-modal sensor system, TRIPWIRE, for containment verification in inaccessible radiological and nuclear waste repositories. The TRIPWIRE system will continuously monitor ionizing radiation and electromagnetic fields in the vicinity of emplaced nuclear materials buried in a repository, reporting on disturbances with a real-time alarm control station. The system will use long-length scintillating fiber bundles (SFBs) to perform area radiation monitoring; these will be coupled to kilometer-scale multimodal optical communication fibers – all light sensors and electronic components used with this system will be located above ground. Electromagnetic fields, and changes in local dielectric conditions caused by intrusion and soil movement, will be monitored using commercial grade, ported "leaky" coaxial cables (PCCs), with control electronics also located above ground. Tamper-indicating self-diagnostic assessments will be done using optical and electronic time domain reflectometry in the SFBs and PCCs, respectively. The result will be a long, kilometer-scale multi-modal SFB-PCC system. Simulation and modeling are being used to inform the work and a demonstration of the system's utility is planned at a nuclear storage facility in the future.

98 - NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL↗

Thermal Storage Applications Workshop. Volume 1: Plenary Session Analysis

The importance of the development of inexpensive and efficient thermal and thermochemical energy storage technology to the solar power program is discussed in a summary of workship discussions held to exchange information and plan for future systems. Topics covered include storage in central power applications such as the 10 MW-e demonstration pilot receiver to be constructed in Barstow, California; storage for small dispersed systems, and problems associated with the development of storage systems for solar power plants interfacing with utility systems.

Source record↗

A High-Rate Lithium Manganese Oxide-Hydrogen Battery

Rechargeable hydrogen gas batteries show promises for the integration of renewable yet intermittent solar and wind electricity into the grid energy storage. Here, we describe a rechargeable, high-rate, and long-life hydrogen gas battery that exploits a nanostructured lithium manganese oxide cathode and a hydrogen gas anode in an aqueous electrolyte. The proposed lithium manganese oxide-hydrogen battery shows a discharge potential of ~1.3 V, a remarkable rate of 50 C with Coulombic efficiency of ~99.8%, and a robust cycle life. A systematic electrochemical study demonstrates the significance of the electrocatalytic hydrogen gas anode and reveals the charge storage mechanism of the lithium manganese oxide-hydrogen battery. This work provides opportunities for the development of new rechargeable hydrogen batteries for the future grid-scale energy storage.

25 ENERGY STORAGE↗

Eighth Goddard Conference on Mass Storage Systems and Technologies in Cooperation with the Seventeenth IEEE Symposium on Mass Storage Systems

This document contains copies of those technical papers received in time for publication prior to the Eighth Goddard Conference on Mass Storage Systems and Technologies which is being held in cooperation with the Seventeenth IEEE Symposium on Mass Storage Systems at the University of Maryland University College Inn and Conference Center March 27-30, 2000. As one of an ongoing series, this Conference continues to provide a forum for discussion of issues relevant to the management of large volumes of data. The Conference encourages all interested organizations to discuss long term mass storage requirements and experiences in fielding solutions. Emphasis is on current and future practical solutions addressing issues in data management, storage systems and media, data acquisition, long term retention of data, and data distribution. This year's discussion topics include architecture, future of current technology, new technology with a special emphasis on holographic storage, performance, standards, site reports, vendor solutions. Tutorials will be available on stability of optical media, disk subsystem performance evaluation, I/O and storage tuning, functionality and performance evaluation of file systems for storage area networks.

Kobler, Benjamin↗

Roles of kaolinite-oil-gas molecular interactions in hydrogen storage within depleted reservoirs

Hydrogen is a clean alternative to fossil fuels, emitting only water vapor during combustion. In a future hydrogen economy, large-scale storage will be an important component of the supply chain. Due to its low volumetric density, conventional surface storage methods are inadequate. Underground hydrogen storage (UHS) offers a viable solution, enabling the storage of millions of cubic meters. Among potential geological sites, including salt caverns, aquifers, and depleted gas reservoirs, depleted oil reservoirs show promise. Studying hydrogen interactions with residual oil and reservoir minerals is vital for understanding the properties of hydrogen and the reservoir post-injection. In this work, we employed molecular dynamics simulations to gain molecular-level insights into these interactions. We investigated hydrogen dissolution in oil, adsorption at kaolinite/oil interfaces, the role of CO 2 as a cushion gas, and the influence of kaolinite’s hydrophobicity on H 2 behavior. The main findings include: (1) hydrogen dissolves more in oil than in water, (2) the introduction of CO 2 suppresses hydrogen dissolution in oil and reduces the interfacial tension (IFT) between oil and gas, (3) CO 2 decreases H 2 partitioning near kaolinite surfaces due to its strong affinity for the hydrophilic gibbsite surface of kaolinite, and (4) CO 2 is more effective than H 2 in reducing IFT between kaolinite and the oil–gas mixture. These findings emphasize the effectiveness of CO 2 as a cushion gas and the important role of clay hydrophobicity in UHS, providing insights that are challenging to obtain experimentally.

08 HYDROGEN↗

Novel CCS Monitoring of Approved Class VI Storage in North Dakota

Presentation at Dallas Geophysical Society Meeting, Dallas, Texas, April 24, 2025. This high-level overview of focuses on novel and sustainable monitoring methods at various stages of planning or demonstration to accelerate the deployment at future carbon capture, utilization, and storage (CCUS) sites.

02 PETROLEUM↗

Bioenergy’s Role in Soil Carbon Storage Decarbonizing Transportation, Agriculture, and Industrial Sectors Workshop Summary Report

On March 28–29, 2022, the U.S. Department of Energy’s (DOE) Bioenergy Technologies Office (BETO) hosted the public virtual workshop “Bioenergy’s Role in Soil Carbon Storage.” Given the recent emphasis of the Biden administration on decarbonizing transportation, agriculture, and industrial sectors of the U.S. economy, this workshop examined how decarbonization through enhanced soil carbon storage while growing bioenergy crops is possible by discussing challenges and opportunities that affect soil carbon levels. Stakeholders representing academia, industry, the farming community, agricultural and forestry sectors, municipalities, and federal agencies involved in soil carbon storage participated in this workshop. A series of keynote presentations, plenary presentations, and stakeholder input sessions provided opportunities for sharing knowledge and identifying research and development (R&D) needs for future advances in soil carbon storage in relation to bioenergy crops. This document provides an overview of the content discussed in the presentations, as well as a summary of the stakeholder input received during the session discussions.

09 BIOMASS FUELS↗

GCAM–GLORY v1.0: representing global reservoir water storage in a multi-sector human–Earth system model

Abstract. Reservoirs play a significant role in modifying the spatiotemporal availability of surface water to meet multi-sector human demands, despite representing a relatively small fraction of the global water budget. Yet the integrated modeling frameworks that explore the interactions among climate, land, energy, water, and socioeconomic systems at a global scale often contain limited representations of water storage dynamics that incorporate feedbacks from other systems. In this study, we implement a representation of water storage in the Global Change Analysis Model (GCAM) to enable the exploration of the future role (e.g., expansion) of reservoir water storage globally in meeting demands for, and evolving in response to interactions with, the climate, land, and energy systems. GCAM represents 235 global water basins, operates at 5-year time steps, and uses supply curves to capture economic competition among renewable water (now including reservoirs), non-renewable groundwater, and desalination. Our approach consists of developing the GLObal Reservoir Yield (GLORY) model, which uses a linear programming (LP)-based optimization algorithm and dynamically linking GLORY with GCAM. The new coupled GCAM–GLORY approach improves the representation of reservoir water storage in GCAM in several ways. First, the GLORY model identifies the cost of supplying increasing levels of water supply from reservoir storage by considering regional physical and economic factors, such as evolving monthly reservoir inflows and demands, and the leveled cost of constructing additional reservoir storage capacity. Second, by passing those costs to GCAM, GLORY enables the exploration of future regional reservoir expansion pathways and their response to climate and socioeconomic drivers. To guide the model toward reasonable reservoir expansion pathways, GLORY applies a diverse array of feasibility constraints related to protected land, population, water sources, and cropland. Finally, the GLORY–GCAM feedback loop allows evolving water demands from GCAM to inform GLORY, resulting in an updated supply curve at each time step, thus enabling GCAM to establish a more meaningful economic value of water. This study improves our understanding of the sensitivity of reservoir water supply to multiple physical and economic dimensions, such as sub-annual variations in climate conditions and human water demands, especially for basins experiencing socioeconomic droughts.

54 ENVIRONMENTAL SCIENCES↗

Metal hydride composition-derived parameters as machine learning features for material design and H 2 storage

Though hydrogen is a promising energy carrier for a green future, many challenges persist. One is the difficulty in engineering storage solutions, with metal hydrides being a leading contender among solid-state strategies. To facilitate efficient searching of candidate materials, ridge regression, simple decision trees, random forest ensembles, and gradient boosting ensembles were employed to predict the energy of formation, with the random forest ensemble resulting in the lowest test set error. First, two public databases, Materials Project and HydPark, were searched for metal hydrides. Feature engineering was performed before the models were developed, resulting in electronegativity, density, atomic density, d-character, f-character, band gap, hydrogen weight fraction, magnetization, temperature, and pressure being retained. The models were then benchmarked by the lowest test error before a random forest ensemble was used to populate entries missing energy of formation. Furthermore, all were then scored by hydrogen storage capacity and energy of formation suitability. Readily available features including several derived from only the chemical formula which were found to be highly predictive. and so are promising for high-throughput screening of arbitrary novel hydride formulations and blends for thermodynamic feasibility.

25 ENERGY STORAGE↗

INL Energy Storage Overview

Briefings provided to Army Science Board Future tank team during their visit to INL in February. This is following the process to release the slides to the Army Science Board.

25 ENERGY STORAGE↗