Search NASA⌕ Search

SEARCH · Search NASA

Results for “Superconducting Detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Enabling Large Focal Plane Arrays Through Mosaic Hybridization

We have demonstrated advances in mosaic hybridization that will enable very large format far-infrared detectors. Specifically we have produced electrical detector models via mosaic hybridization yielding superconducting circuit patbs by hybridizing separately fabricated sub-units onto a single detector unit. The detector model was made on a 100mm diameter wafer while four model readout quadrant chips were made from a separate 100mm wafer. The individually fabric.ted parts were hybridized using a Suss FCI50 flip chip bonder to assemble the detector-readout stack. Once all of the hybridized readouts were in place, a single, large and thick silicon substrate was placed on the stack and attached with permanent epoxy to provide strength and a Coefficient of Thermal Expansion match to the silicon components underneath. Wirebond pads on the readout chips connect circuits to warm readout electronics; and were used to validate the successful superconducting electrical interconnection of the model mosaic-hybrid detector. This demonstration is directly scalable to 150 mm diameter wafers, enabling pixel areas over ten times the area currently available.

Miller, Timothy M.↗

Insertion Loss of a Multi-Plane Light Conversion Device with Few Mode Fiber Outputs Under Atmospheric Conditions

A key challenge of photon counting optical communication is delivering light with atmospherically distorted wavefronts from the telescope to detectors efficiently. When using fiber coupled single photon detectors, the efficiency of the transmittance is constrained by the modes supported by the fiber. The number of modes supported by a fiber depends on the size of the core. The larger the core, the more modes supported. However, commercial off the shelf superconducting nanowire single photon detectors (SNSPDs) are currently limited in area, which limits the core size of the fibers that can efficiently couple to the detectors. To increase the amount of light that can be delivered to the detectors, NASA Glenn Research Center is considering many different fiber/detector architectures. This paper compares insertion loss of the fiber device for two different architectures: • a multi-plane light conversion device to split the light from a 30 µm core diameter fiber into 7 separate, 15 µm core diameter few-mode fibers butt-coupled to 7 single-element SNSPDs, and • a 30 µm core diameter multimode fiber butt-coupled to a 16 multi-element, SNSPD array. The measured insertion loss for each fiber device under emulated atmospheric conditions with D/r0 between 2 and 30 is presented. The multi-plane light conversion device shows a consistent ~1 dB loss more than the multimode fiber. Also presented is the measured uneven power splitting of the multiplane light conversion device, especially at lower D/r0. How this uneven power splitting contributes to system loss called blocking loss is discussed.

Fiber↗

Insertion Loss of a Multi-Plane Light Conversion Device with Few Mode Fiber Outputs Under Atmospheric Conditions

A key challenge of photon counting optical communication is delivering light with atmospherically distorted wavefronts from the telescope to detectors efficiently. When using fiber coupled single photon detectors, the efficiency of the transmittance is constrained by the modes supported by the fiber. The number of modes supported by a fiber depends on the size of the core. The larger the core, the more modes supported. However, commercial off the shelf superconducting nanowire single photon detectors (SNSPDs) are currently limited in area, which limits the core size of the fibers that can efficiently couple to the detectors. To increase the amount of light that can be delivered to the detectors, NASA Glenn Research Center is considering many different fiber/detector architectures. This paper compares insertion loss of the fiber device for two different architectures: • a multi-plane light conversion device to split the light from a 30 µm core diameter fiber into 7 separate, 15 µm core diameter few-mode fibers butt-coupled to 7 single-element SNSPDs, • and a 30 µm core diameter multimode fiber butt-coupled to a 16 multi-element, SNSPD array. The measured insertion loss for each fiber device under emulated atmospheric conditions with D/r0 between 2 and 30 is presented. The multi-plane light conversion device shows a consistent ~1 dB loss more than the multimode fiber. Also presented is the measured uneven power splitting of the multiplane light conversion device, especially at lower D/r0. How this uneven power splitting contributes to system loss called blocking loss is discussed.

Multi-plane light conversion device↗

Enhancing spectroscopy and microscopy with emerging methods in photon correlation and quantum illumination

Quantum optics has led to important advancements in our ability to prepare and detect correlations between individual photons. Its principles are increasingly translated into nanoscale characterization tools, furthering methods in spectroscopy, microscopy and metrology. Here, in this Review, we discuss the rapid progress in this field driven by advanced technologies of single-photon detectors and quantum-light sources, including time-resolved single-photon counting cameras, superconducting nanowire single-photon detectors and entangled photon sources of increasing brightness. We emphasize emerging applications in super-resolution microscopy, measurements below classical noise limits and photon-number-resolved spectroscopy—a powerful paradigm for the characterization of nanoscale electronic materials. We conclude by discussing key technological challenges and future opportunities in materials science and bionanophotonics alike.

Tsao, Chieh [University of California, Berkeley, C↗

A Compact, Modular Package for Superconducting Bolometer Arrays

As bolometer arrays grow to ever-larger formats, packaging becomes a more critical engineering issue. We have designed a detector package to house a superconducting bolometer array, SQUID multiplexers, bias and filtering circuitry, and electrical connectors. The package includes an optical filter, magnetic shielding, and has well-defined thermal and mechanical interfaces. An early version of this package has been used successfully in the GISMO 2mm camera, a 128-pixel camera operating at a base temperature of 270mK. A more advanced package permits operation at lower temperatures by providing direct heat sinking to the SQUIDS and bias resistors, which generate the bulk of the dissipation in the package. Standard electrical connectors provide reliable contact while enabling quick installation and removal of the package. We describe how the design compensates for differing thermal expansions, allows heat sinking of the bolometer array, and features magnetic shielding in critical areas. We highlight the performance of this detector package and describe its scalability to 1280-pixel arrays in the near future.

Benford, D.↗

NASA Tech Briefs, July 2008

Topics covered include: Torque Sensor Based on Tunnel-Diode Oscillator; Shaft-Angle Sensor Based on Tunnel-Diode Oscillator; Ground Facility for Vicarious Calibration of Skyborne Sensors; Optical Pressure-Temperature Sensor for a Combustion Chamber; Impact-Locator Sensor Panels; Low-Loss Waveguides for Terahertz Frequencies; MEMS/ECD Method for Making Bi(2-x)Sb(x)Te3 Thermoelectric Devices; Low-Temperature Supercapacitors; Making a Back-Illuminated Imager with Back-Side Contact and Alignment Markers; Compact, Single-Stage MMIC InP HEMT Amplifier; Nb(x)Ti(1-x)N Superconducting-Nanowire Single-Photon Detectors; Improved Sand-Compaction Method for Lost-Foam Metal Casting; Improved Probe for Evaluating Compaction of Mold Sand; Polymer-Based Composite Catholytes for Li Thin-Film Cells; Using ALD To Bond CNTs to Substrates and Matrices; Alternating-Composition Layered Ceramic Barrier Coatings; Variable-Structure Control of a Model Glider Airplane; Axial Halbach Magnetic Bearings; Compact, Non-Pneumatic Rock-Powder Samplers; Biochips Containing Arrays of Carbon-Nanotube Electrodes; Nb(x)Ti(1-x)N Superconducting-Nanowire Single-Photon Detectors; Neon as a Buffer Gas for a Mercury-Ion Clock; Miniature Incandescent Lamps as Fiber-Optic Light Sources; Bidirectional Pressure-Regulator System; and Prism Window for Optical Alignment. Single-Grid-Pair Fourier Telescope for Imaging in Hard-X Rays and gamma Rays Range-Gated Metrology with Compact Optical Head Lossless, Multi-Spectral Data Compressor for Improved Compression for Pushbroom-Typetruments.

Source record↗

Search for New Physics with the Compact Muon Solenoid Experiment and QIS-enabled Technology

Understanding the fundamental nature of dark matter (DM)---its cosmological origin, constituents, and interactions---is one of the most important questions in fundamental science today. In this thesis, I present two novel and highly complementary approaches to cover the gaps in sensitivity of current DM searches. The searches are enabled by a first-of-its-kind reconstruction technique to search for hidden-sector particles using the Compact Muon Solenoid (CMS) and by new advances in quantum sensing technology to search for axions and hidden-sector DM. In the first part of this thesis, I present a search for long-lived hidden sector particles, predicted by many extensions of the SM, using a novel technique to reconstruct decays of long-lived particles (LLPs) in the CMS muon detector. The innovative LLP reconstruction technique is sensitive to a broad range of LLP decays and to LLP masses below GeV. The search yields competitive sensitivity for proper lifetime 0.1--1000 m with the full Run 2 dataset recorded at the LHC between 2016--2018 at $\sqrt{s} = 13~$TeV. To extend the physics reach of this novel muon detector shower (MDS) signature, I present the model-independence of MDS and the reinterpretation of the search to a large number of LLP models, demonstrating its complementarity with proposed and existing dedicated LLP experiments. Finally, I present a new dedicated MDS trigger that improves the trigger efficiency by at least an order of magnitude and was deployed in 2022, at the start of Run 3 of the LHC operations. In the second part of the thesis, I present for the first time, the use of a novel quantum sensor, the low-noise and single-photon sensitive superconducting nanowire single photon detectors (SNSPDs), to directly detect dark matter. The low detection threshold and ultra-low dark count rate of SNSPDs can close the gap in DM discovery reach due to the current limitations in detector sensitivity. I will present my work on the development and characterization of SNSPDs for two entirely new experiments to directly detect axions via absorption and hidden-sector DM via electron scattering. The search for axions employs a novel broadband reflector technique with the Broadband Reflector Experiment for Axion Detection (BREAD). A unique parabolic mirror is then used to focus axion-converted photons to the SNSPDs, extending the reach to axion masses of 0.04--1 eV. On the other hand, by coupling the SNSPDs with gallium arsenide, a bright cryogenic scintillator well matched to SNSPD detection, a prototype sensing system can be built as a basis of new direct DM detection experiments capable of extending the discovery to DM masses as low as 1 MeV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Harnessing the Quantum Zeno Effect in superconducting qubits for particle detection

Superconducting qubits, originally developed for quantum computing, are emerging as a potentially powerful tool for detecting low-energy particle interactions, such as dark matter and neutrinos. These devices can register energy deposits as small as a few meV, dramatically lowering the detection threshold compared to conventional sensors. However, their deployment in rare-event searches is hampered by a critical and unresolved background: Two-Level Systems (TLSes). TLSes are material defects that can scramble qubit frequencies and coherence times in a way that resembles particle energy deposits. Such false signals can critically limit the sensitivity and extend experimental runtimes for qubit-based sensors by years. This talk introduces a novel method to eliminate TLSes as a background source in superconducting qubit-based detectors. By harnessing the Quantum Zeno Effect (QZE), a well-established quantum phenomenon where frequent observation inhibits system evolution, I will discuss the possibility of “freezing” these TLS defects in place. This effectively suppresses their interference, stabilizes qubit behavior, and opens the door to using TLSes themselves as auxiliary sensors. I have already identified target TLSes and observed early signs of QZE-like dynamics in Fermilab-fabricated devices. The method builds on my existing collaborations at Fermilab’s Quantum Information Testbed (QUIET), with access to low muon flux cryogenic facilities 100 meters underground, control electronics, and expert mentors across multiple institutions. By removing a key bottleneck to superconducting sensor deployment, this research targets advancing the development of a general-purpose technique to enhance sensitivity, reduce false positives, and accelerate discovery in searches for dark matter, neutrinos, and other rare phenomena.

Seidel, Olivia [Texas U., Arlington]↗

Imaging antenna arrays

Many millimeter and far-infrared imaging systems are limited in sensitivity and speed because they depend on a single scanned element. Because of recent advances in planar detectors such as Schottky diodes, superconducting tunnel junctions, and microbolometers, an attractive approach to this problem is a planar antenna array with integrated detectors. A planar line antenna array and optical system for imaging has been developed. The significant advances are a 'reverse-microscope' optical configuration and a modified bow-tie antenna design. In the 'reverse-microscope' configuration, a lens is attached to the bottom of the substrate containing the antennas. Imaging is done through the substrate. This configuration eliminates the troublesome effects of substrate surface waves. The substrate lens has only a single refracting surface, making possible a virtually aplanatic system, with little spherical aberration or coma. The array is characterized by an optical transfer function that is easily measured. An array with 19 dB crosstalk levels between adjacent antennas has been tested and it was found that the array captured 50 percent of the available power. This imaging system was diffraction limited.

Rutledge, D. B.↗

Quench Analysis of EIC Central Detector (ePIC) Solenoid Magnet (MARCO)

The 2.0 T superconducting solenoid magnet (MARCO) being designed to be built for the EIC central detector (ePIC). Here, the magnet consists of three set of coil in a vacuum impregnated coil pack. Each coil pack consists of a total 554 turns winding wrapped with 6 layers of winding per coil. The coil case assembly is cooled by supercritical helium at 4.6 K. This manuscript presents quench analysis carried out on the magnet system along with the conductor stability. For the normal operation the magnet at 4.6 K and at normal operating current, the quench evaluation is carried out at 4.7 K for design assessment. The quench analysis carried out using commercial multi-physics FEA tool along an equivalent single coil quench model and the requirements for the magnet protection is also presented.

Ghoshal, Probir K. [Thomas Jefferson National Acce↗

The Data Acquisition System for Phase-III of the BeEST Experiment

The BeEST experiment is a precision laboratory search for physics beyond the standard model that measures the electron capture decay of 7 Be implanted into superconducting tunnel junction (STJ) detectors. For Phase-III of the experiment, we constructed a continuously sampling data acquisition system to extract pulse shape and timing information from 16 STJ pixels offline. Four additional pixels are read out with a fast list-mode digitizer, and one with a nuclear MCA already used in the earlier limit-setting phases of the experiment. Here, we present the performance of the data acquisition system and discuss the relative advantages of the different digitizers.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Anatomy of Protein Electrospray Ionization Mass Spectra by Superconducting Tunnel Junction Mass and Energy Spectrometry

Cryogenic superconducting tunnel junction (STJ) detectors have the advantage of single-particle sensitivity, high quantum efficiency, low noise, and the ability to detect the time and relative impact energy of deposited ions. This makes them attractive for use in mass spectrometry (MS) and as a form of energy spectrometry. STJ cryodetectors have been coupled to time-offlight (TOF) mass spectrometers equipped with a matrix-assisted laser desorption ionization (MALDI) source and to an electrospray ionization (ESI) TOF mass spectrometer. Here, a lab-made linear ion trap (LIT) mass spectrometer system was coupled to an ESI source and a 16-channel Nb-STJ array with improved readout electronics. The goal was to investigate fundamentals of ESI-generated protein ions by further exploiting the advantage of resolving these ions in a third dimension of the relative energy deposited into the STJs. The proteins equine cytochrome c, bovine carbonic anhydrase, bovine serum albumin, and murine immunoglobulin G were studied using this ESI-LIT-STJ-MS instrument. Multiply charged monomers, multimers, and fragments from metastable ions were resolved from monomer peaks by differences in ion deposition energy even when these ions have the same mass-to-charge ratio as the corresponding monomer. The determination of fragment mass from metastable decomposition is accomplished without knowing the charge state of the fragment. The average charge state of the multimers is reduced with each addition of a protein which is a direct reflection of the surface area available for charging. Multiply charged in-source fragments have also been observed and distinguished in the mass spectrum of carbonic anhydrase by using the differences in the energy deposited in the STJs.

42 ENGINEERING↗

Sub-2 Kelvin Characterization of Nitrogen-Vacancy Centers in Silicon Carbide Nanopillars

The development of efficient quantum communication technologies depends on the innovation in multiple layers of its implementation, a challenge we address from the fundamental properties of the physical system at the nanoscale to the instrumentation level at the macroscale. We select a promising near-infrared quantum emitter, the nitrogen-vacancy (NV) center in 4H-SiC, and integrate it, at an ensemble level, with nanopillar structures that enhance photon collection efficiency into an objective lens. Moreover, changes in collection efficiency in pillars compared to bulk can serve as indicators of color center orientation in the lattice. To characterize NV center properties at the unprecedented sub-2 K temperatures, we incorporate compatible superconducting nanowire single photon detectors inside the chamber of an optical cryostat and create the ICECAP, the Integrated Cryogenic system for Emission, Collection And Photon detection. ICECAP measurements show no significant line-width broadening of NV ensemble emission and up to 14-fold enhancement in collected emission. With additional filtering, we measure emitter lifetimes of NV centers in a basal ( hk ) and axial ( kk ) orientation, unveiling their cryogenic values of 2.2 and 2.8 ns.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Temperature trends and correlation between SQUID superparamagnetic relaxometry and dc-magnetization on model iron-oxide nanoparticles

Structural properties of iron-oxide nanoparticles deeply affect their magnetic performance in many applications such as with superparamagnetic relaxometry, when employed as cell-targeted magnetic nanoparticles for in vivo diagnostics. In this work, we present a detailed characterization of model nanoparticles for this application, with an average size of ~25 nm and a narrow size dispersion (σ < 7%). Considering the intrinsic structural properties of these model nanoparticles, the study of temperature dependence and correlation between dc-magnetization and superconducting quantum interference detector-relaxometry are discussed based on known theoretical predictions and computer simulations of the magnetic dipole moment and characteristic decay constants. Furthermore, computer simulations provide support in clarifying how important the overall collective magnetization is affected by particle size dispersion, which has a direct role on sustaining the magnetic relaxation signal in the temperature range required in preclinical and clinical settings.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

High-resolution Compton spectroscopy using x-ray microcalorimeters

X-ray Compton spectroscopy is one of the few direct probes of the electron momentum distribution of bulk materials in ambient and operando environments. Herein, we report high-resolution inelastic x-ray scattering experiments with high momentum and energy transfer performed at a storage-ring-based high-energy x-ray light source facility using an x-ray transition-edge sensor (TES) microcalorimeter detector. The performance was compared with a silicon drift detector (SDD), an energy-resolving semiconductor detector, and Compton profiles were measured for lithium and cobalt oxide powders relevant to lithium-ion battery research. Spectroscopic analysis of the measured Compton profiles demonstrates the high-sensitivity to the low- Z elements and oxidation states. The line shape analysis of the measured Compton profiles in comparison with computed Hartree–Fock profiles is usually limited by the resolution of the semiconductor detector. We have characterized an x-ray TES microcalorimeter detector for high-resolution Compton scattering experiments using a bending magnet source at the Advanced Photon Source with a double crystal monochromator, providing monochromatic photon energies near 27.5 keV. The momentum resolution below 0.16 atomic units (a.u.) was measured, yielding an improvement of more than a factor of 7 over a state-of-the-art SDD for the same scattering geometry. Furthermore, the lineshapes of narrow valence and broad core electron profiles of sealed lithium metal were clearly resolved using an x-ray TES compared to smeared and broadened lineshapes observed when using the SDD. High-resolution Compton scattering using the energy-resolving area detector shown here presents new opportunities for spatial imaging of electron momentum distributions for a wide class of materials with applications ranging from electrochemistry to condensed matter physics.

47 OTHER INSTRUMENTATION↗

β-decay feeding intensity distributions for 103,104m Nb

The β decays of 103,104m Nb were studied with the Summing NaI(Tl) (SuN) detector at the National Superconducting Cyclotron Laboratory. The β-decay feeding intensity distribution I β (E) for each isotope was extracted by measuring γ rays in coincidence with an emitted electron. The I β (E) was extracted via the total absorption spectroscopy technique. The I β (E) for each nucleus was compared to predictions made by the quasiparticle random-phase approximation (QRPA) model which is commonly used to calculate β-decay properties for astrophysical applications. The main goal was to provide experimental data for neutron-rich nuclei, relevant to the astrophysical r process. In addition, the extracted β-decay feeding intensity distributions can lead to a better understanding of nuclear structure in a region of rapid structure changes around A = 100. Finally, experimental data for 104m Nb are also of interest to antineutrino studies of nuclear reactors

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Spectroscopic Measurements and Models of Energy Deposition in the Substrate of Quantum Circuits by Natural Ionizing Radiation

Naturally occurring background radiation is a potential source of correlated decoherence events in superconducting qubits that will challenge error-correction schemes. In order to characterize the radiation environment in an unshielded laboratory representative of superconducting qubits’ environments, we performed broadband, spectroscopic measurements of background radiation events inside a millikelvin refrigerator. The spectrometer was designed to mimic the size and composition of a quantum circuit. Specifically, we measured the background radiation spectra in silicon substrates of two thicknesses, 500 and 1500 µm, and one area, 25 mm 2 . The observed spectra span energies from a few kilo-electron-volts up to nearly 10 MeV, are nearly featureless, and decrease in intensity by a factor of 40 000 between 100 keV and 3 MeV for the 500-µm substrate. We integrate the spectra to obtain the average event rates and deposited power levels. These quantities correspond to a rate of 0.023 events per second and a power of 4.9 keV s -1 , when counting events that deposit at least 40 keV for the 500-µm-thick substrate. We find that the cryogenic measurements are in good agreement with predictions based on simple measurements of the terrestrial gamma-ray flux outside the refrigerator, published models of cosmic-ray fluxes, a crude model of the cryostat, and radiation-transport simulations. This model requires no free parameters to predict the background radiation spectra in the silicon substrates. The agreement between measurements and predictions demonstrates that the model we present can be used to assess the relative contributions of terrestrial and cosmic-ray sources to background radiation interactions in silicon substrates of varying thickness. These spectroscopic measurements are performed with a novel combination of superconducting microresonators located on micromachined silicon islands that define the interaction volume with background radiation. The resonators transduce deposited energy to a readily detectable electrical signal. Microresonator readout closely resembles dispersive superconducting qubit readout, so similar devices—with or without micromachined islands—are suitable for integration with superconducting quantum circuits as detectors for background radiation events. For our specific laboratory conditions, we find that gamma-ray emissions from radioisotopes are responsible for the majority of events that deposit E < 1 ⁢Me⁢V. We present results demonstrating that the background radiation spectrum contains relevant contributions from cosmic-ray particles other than muons, particularly a tail of multi-mega-electron-volt events due to protons and neutrons. These observations suggest several paths to reducing the impact of background radiation on quantum circuits, supported by an empirically validated model for generating reliable predictions of radiation interactions with silicon substrates.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Focusing Optics for Axion Detection: Simulating Sensing Enhancements of Photons in InfraBREAD

The Broadband Reflector Experiment for Axion Detection (BREAD) will search for axions, a promising particle candidate for dark matter, in the high mass range of [$10^{-3}$,1]eV. BREAD acts like a telescope for dark matter, using a parabolic reflector to direct axion-induced photons onto a precise focal spot. InfraBREAD is the experimental version designed to detect photons resulting from axions with infrared frequency using a 1mm × 1mm Superconducting Nanowire Singe Photon Detector (SNSPD). However, at this frequency scale two problems arise: 1) the focal spot becomes smeared across an area larger than the size of the SNSPD detector; 2) any millimeter-scale misalignment shifts in the SNSPD can greatly diminish photon signal. This study performed simulations of novel optical configurations of lenses and reflectors placed around the SNSPD to achieve a greater efficiency than the SNSPD alone through both of these effects. One optical setup was identified called the “Parabolo id to Winston Cone (PTW) Configuration,” which exploits the optics of parabolic reflectors to focus incoming photons from the larger area of the smeared focal spot onto the smaller 1mm 2 area of the detector. The PTW configuration demonstrated overall improvements in efficiency by around 10% through misalignment shifts, with a maximal improvement of 55% in one region.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗