Search NASA⌕ Search

SEARCH · Search NASA

Results for “Systems Health Monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Packaged Capacitive Pressure Sensor System for Aircraft Engine Health Monitoring

This paper describes the development of a packaged silicon carbide (SiC) based MEMS pressure sensor system designed specifically for a conventional turbofan engine. The electronic circuit is based on a Clapp-type oscillator that incorporates a 6H-SiC MESFET, a SiCN MEMS capacitive pressure sensor, titanate MIM capacitors, wirewound inductors, and thick film resistors. The pressure sensor serves as the capacitor in the LC tank circuit, thereby linking pressure to the resonant frequency of the oscillator. The oscillator and DC bias circuitry were fabricated on an alumina substrate and secured inside a metal housing. The packaged sensing system reliably operates at 0 to 350 psi and 25 to 540C. The system has a pressure sensitivity of 6.8 x 10E-2 MHzpsi. The packaged system shows negligible difference in frequency response between 25 and 400C. The fully packaged sensor passed standard benchtop acceptance tests and was evaluated on a flight-worthy engine.

Harsh environment↗

WE-D-9A-06: Open Source Monitor Calibration and Quality Control Software for Enterprise Display Management

Purpose: Medical display monitor calibration and quality control present challenges to medical physicists. The purpose of this work is to demonstrate and share experiences with an open source package that allows for both initial monitor setup and routine performance evaluation. Methods: A software package, pacsDisplay, has been developed over the last decade to aid in the calibration of all monitors within the radiology group in our health system. The software is used to calibrate monitors to follow the DICOM Grayscale Standard Display Function (GSDF) via lookup tables installed on the workstation. Additional functionality facilitates periodic evaluations of both primary and secondary medical monitors to ensure satisfactory performance. This software is installed on all radiology workstations, and can also be run as a stand-alone tool from a USB disk. Recently, a database has been developed to store and centralize the monitor performance data and to provide long-term trends for compliance with internal standards and various accrediting organizations. Results: Implementation and utilization of pacsDisplay has resulted in improved monitor performance across the health system. Monitor testing is now performed at regular intervals and the software is being used across multiple imaging modalities. Monitor performance characteristics such as maximum and minimum luminance, ambient luminance and illuminance, color tracking, and GSDF conformity are loaded into a centralized database for system performance comparisons. Compliance reports for organizations such as MQSA, ACR, and TJC are generated automatically and stored in the same database. Conclusion: An open source software solution has simplified and improved the standardization of displays within our health system. This work serves as an example method for calibrating and testing monitors within an enterprise health system.

60 APPLIED LIFE SCIENCES↗

Annual Health Monitoring Conference for Space Propulsion Systems, 2nd, Cincinnati, OH, Nov. 14, 15, 1990, Proceedings

This conference discusses health management systems for liquid rocket engines, signal processing of spectroscopic data for engine diagnostic applications, real-time diagnostics of the reusable rocket engine using on-line system identification, and nonlinear parameter estimation for rocket engine health monitoring. Plume diagnostics are considered including discussion on preliminary plume diagnostics on the SSME using video digitization techniques and baseline plume emmissions. The development of a Fabry-Perot Interferometer for rocket engine plumes is also considered. The topic of computational modeling is also discussed, addressing such topics as probabalistic dynamics of material loss in the SSME turbomachinery, state-variable modelling of fluid-dynamics processes, and a model for the SSME high pressure oxidizer turbopump shaft seal system. A discussion of sensor development includes the topics of sensor development for the rocket engine condition monitoring system and the heat flux measurements in SSME turbine blade tester.

Source record↗

Demonstration of a Packaged Capacitive Pressure Sensor System Suitable for Jet Turbofan Engine Health Monitoring

In this paper, the development and characterization of a packaged pressure sensor system suitable for jet engine health monitoring is demonstrated. The sensing system operates from 97 to 117 MHz over a pressure range from 0 to 350 psi and a temperature range from 25 to 500 deg. The sensing system consists of a Clapp-type oscillator that is fabricated on an alumina substrate and is comprised of a Cree SiC MESFET, MIM capacitors, a wire-wound inductor, chip resistors and a SiCN capacitive pressure sensor. The pressure sensor is located in the LC tank circuit of the oscillator so that a change in pressure causes a change in capacitance, thus changing the resonant frequency of the sensing system. The chip resistors, wire-wound inductors and MIM capacitors have all been characterized at temperature and operational frequency, and perform with less than 5% variance in electrical performance. The measured capacitive pressure sensing system agrees very well with simulated results. The packaged pressure sensing system is specifically designed to measure the pressure on a jet turbofan engine. The packaged system can be installed by way of borescope plug adaptor fitted to a borescope port exposed to the gas path of a turbofan engine.

Harsh environment↗

Detection of System Drift for the Health Monitoring of an X-ray CT Scientific Instrument

This SE296 Capstone Project technical report is being submitted as a final requirement of the UCSD Master of Science in Structural Engineering with specialization in Structural Health Monitoring (SHM) and Nondestructive Evaluation (NDE). The Capstone provides students the opportunity to apply knowledge in their technology areas towards the solution of an SHM or NDE problem. As an employee of the Lawrence Livermore National Laboratory and NDE/NCI team member, I chose to apply the SHM design paradigm taught at UCSD to improve the health monitoring of the X-ray Micro-Computed Tomography (MCT) system. I would like to thank LLNL’s Dr. Harry Martz for serving as my mentor during this project and the entire LLNL MCT technical team for answering my questions and contributing to my knowledge. I would also like to thank Prof. Michael Todd for recruiting me to the UCSD NDE/SHM program and serving as my graduate advisor.

42 ENGINEERING↗

Sensor Fault Detection and Diagnosis Simulation of a Helicopter Engine in an Intelligent Control Framework

This paper presents an application of a fault detection and diagnosis scheme for the sensor faults of a helicopter engine. The scheme utilizes a model-based approach with real time identification and hypothesis testing which can provide early detection, isolation, and diagnosis of failures. It is an integral part of a proposed intelligent control system with health monitoring capabilities. The intelligent control system will allow for accommodation of faults, reduce maintenance cost, and increase system availability. The scheme compares the measured outputs of the engine with the expected outputs of an engine whose sensor suite is functioning normally. If the differences between the real and expected outputs exceed threshold values, a fault is detected. The isolation of sensor failures is accomplished through a fault parameter isolation technique where parameters which model the faulty process are calculated on-line with a real-time multivariable parameter estimation algorithm. The fault parameters and their patterns can then be analyzed for diagnostic and accommodation purposes. The scheme is applied to the detection and diagnosis of sensor faults of a T700 turboshaft engine. Sensor failures are induced in a T700 nonlinear performance simulation and data obtained are used with the scheme to detect, isolate, and estimate the magnitude of the faults.

Litt, Jonathan↗

Opportunities and challenges for structural health monitoring of radioactive waste systems and structures

Radioactive waste systems and structures (RWSS) are safety-critical facilities in need of monitoring over prolonged periods of time. Structural health monitoring (SHM) is an emerging technology that aims at monitoring the state of a structure through the use of networks of permanently mounted sensors. SHM technologies have been developed primarily within the aerospace and civil engineering communities. This paper addresses the issue of transitioning the SHM concept to the monitoring of RWSS and evaluates the opportunities and challenges associated with this process. Guided wave SHM technologies utilizing structurally-mounted piezoelectric wafer active sensors (PWAS) have a wide range of applications based on both propagating-wave and standing-wave methodologies. Hence, opportunities exist for transitioning these SHM technologies into RWSS monitoring. However, there exist certain special operational conditions specific to RWSS such as: radiation field, caustic environments, marine environments, and chemical, mechanical and thermal stressors. In order to address the high discharge of used nuclear fuel (UNF) and the limited space in the storage pools the U.S. the Department of Energy (DOE) has adopted a 'Strategy for the Management and Disposal of Used Nuclear Fuel and High-Level Radioactive Waste' (January 2013). This strategy endorses the key principles that underpin the Blue Ribbon Commission's on America's Nuclear Future recommendations to develop a sustainable program for deploying an integrated system capable of transporting, storing, and disposing of UNF and high-level radioactive waste from civilian nuclear power generation, defense, national security, and other activities. This will require research to develop monitoring, diagnosis, and prognosis tools that can aid to establish a strong technical basis for extended storage and transportation of UNF. Monitoring of such structures is critical for assuring the safety and security of the nation's spent nuclear fuel until a national policy for closure of the nuclear fuel cycle is defined and implemented. In addition, such tools can provide invaluable and timely information for verification of the predicted mechanical performance of RWSS (e.g. concrete or steel barriers) during off-normal occurrence and accident events such as the tsunami and earthquake event that affected Fukushima Daiichi nuclear power plant. The ability to verify the conditions, health, and degradation behavior of RWSS over time by applying nondestructive testing (NDT) as well as development of nondestructive evaluation (NDE) tools for new degradation processes will become challenging. The paper discusses some of the challenges associated to verification and diagnosis for RWSS and identifies SHM technologies which are more readily available for transitioning into RWSS applications. Fundamental research objectives that should be considered for the transition of SHM technologies (e.g., radiation hardened piezoelectric materials) for RWSS applications are discussed. The paper ends with summary, conclusions, and suggestions for further work. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Nominal Device Support for ATCA Shelf Manager

The ATCA standard specifies a mandatory Shelf Manager (ShM) unit which is a key element for the system operation. It includes the Intelligent Platform Management Controller (IPMC) which monitors the system health, retrieves inventory information and controls the Field Replaceable Units (FRUs). These elements enable the intelligent health monitoring, providing high-availability and safety operation, ensuring the correct system operation. For critical systems like ones of tokamak ITER these features are mandatory to support the long pulse operation. The Nominal Device Support (NDS) was designed and developed for the ITER CODAC Core System (CCS), which will be the responsible for plant Instrumentation and Control (I and C), supervising and monitoring on ITER. It generalizes the Enhanced Physics and Industrial Control System (EPICS) device support interface for Data Acquisition (DAQ) and timing devices. However the support for health management features and ATCA ShM are not yet provided. This paper presents the implementation and test of a NDS for the ATCA ShM, using the ITER Fast Plant System Controller (FPSC) prototype environment. This prototype is fully compatible with the ITER CCS and uses the EPICS Channel Access (CA) protocol as the interface with the Plant Operation Network (PON). The implemented solution running in an EPICS Input / Output Controller (IOC) provides Process Variables (PV) to the PON network with the system information. These PVs can be used for control and monitoring by all CA clients, such as EPICS user interface clients and alarm systems. The results are presented, demonstrating the fully integration and the usability of this solution. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Integrating Condition Indicators and Usage Parameters for Improved Spiral Bevel Gear Health Monitoring

The objective of this study was to illustrate the importance of combining Health Usage Monitoring Systems (HUMS) data with usage monitoring system data when detecting rotorcraft transmission health. Six gear sets were tested in the NASA Glenn Spiral Bevel Gear Fatigue Rig. Damage was initiated and progressed on the gear and pinion teeth. Damage progression was measured by debris generation and documented with inspection photos at varying torque values. A contact fatigue analysis was applied to the gear design indicating the effect temperature, load and reliability had on gear life. Results of this study illustrated the benefits of combining HUMS data and actual usage data to indicate progression of damage for spiral bevel gears.

Dempsey, Paula J.↗

Integrating Condition Indicators and Usage Parameters for Improved Spiral Bevel Gear Health Monitoring

The objective of this study was to illustrate the importance of combining Health Usage Monitoring Systems (HUMS) data with usage monitoring system data when detecting rotorcraft transmission health. Three gear sets were tested in the NASA Glenn Spiral Bevel Gear Fatigue Rig. Damage was initiated and progressed on the gear and pinion teeth. Damage progression was measured by debris generation and documented with inspection photos at varying torque values. A contact fatigue analysis was applied to the gear design indicating the effect temperature, load and reliability had on gear life. Results of this study illustrated the benefits of combining HUMS data and actual usage data to indicate progression of damage for spiral bevel gears.

Dempsey, Paula J.↗

Improving Computational Efficiency of Prognostics Algorithms in Resource-Constrained Settings

The field of prognostics and health management provides quantitative methods for monitoring and predicting the health of physical systems. Prognostics algorithms are useful in that they can be employed to assess the current state of a system, propagate the system state throughout time, and predict potential anomalies or failures that may occur. However, effective prognosis can be challenging to achieve in resource-constrained settings due to computational limitations and high computational latency, leading to obsolete predictions. Thus, computationally efficient and accurate algorithms are necessary for some prognostics applications. In this work, we implement three new algorithmic approaches to prediction (sampling methods, variable prediction time step, variable prediction sample size) with the goal of improving computational efficiency while minimizing decrease in model accuracy. To quantitatively analyze our results, we examine a use-case of degradation of a Lithium-ion battery. Notably, through this work it was found that none of the sampling approaches had a significant impact on computational efficiency or model accuracy in predicting EOD of the battery. However, our results show that prediction accuracy is highly dependent on the time step used, and that an appropriate time step can optimize both model accuracy and simulation efficiency. Finally, implementing a variable sample size also affected prediction, and our results show that tuning both the magnitude and timing of the sample size adjustment in an application-specific manner may prove useful in some applications. Taken together, our findings highlight the challenge of performing prognostics in resource-constrained settings, and illustrate the potential of developing new prediction algorithms to improve computational efficiency of prognosis.

Prognostics↗

Runtime Monitoring with R2U2 for Aircraft Systems with Neural Networks

R2U2 (Realizable, Responsive, Unobtrusive Unit) is a hardware-supported tool and framework for real-time system monitoring and software health management of cyber-physical systems. During system operation, R2U2 continuously monitors properties about safety, performance, and security of the vehicle and its vital components and can perform diagnostic reasoning. Efficient observers for past-time and future-time Metric Temporal Logic, fast reasoners for Bayesian Networks, and model-based prognostics algorithms are key components of R2U2 and designed for minimal computational footprint. R2U2 has been implemented in software supporting ROS, NASA's cFS/cFE, and Simulink and as an FPGA configuration. The synergistic combination of monitors and observers in R2U2 makes it possible to design powerful models for system runtime monitoring, diagnostics, software health management, prognostics, and security monitoring. In this presentation, I will give a detailed overview of the R2U2 architecture and its features and will discuss the application of R2U2 for safety-monitoring of a neural-network based autonomous centerline tracking system (ACT) for autonomous aircraft.

Runtime Monitoring↗

Smart Sensor Systems for Human Health and Environmental Applications

Sensors and sensor systems are central to providing improved awareness of an individual's health state and surroundings. This presentation describes efforts to develop Smart Sensor Systems for a range of health and safety applications moving towards distributed intelligence. This includes efforts to develop a human health breath monitoring system using this microsensor Smart Sensor System approach. The same core technology can be used for a range of applications related to improved human health and environmental monitoring. Other examples of human health relevant technology development will also be given.

Smart Sensors Health↗

Ability of Impedance-Based Health Monitoring To Detect Structural Damage of Propulsion System Components Assessed

Impedance-based structural-health-monitoring uses piezoelectric (PZT) patches that are bonded onto or embedded in a structure. Each individual patch behaves as both an actuator of the surrounding structural area as well as a sensor of the structural response. The size of the excited area varies with the geometry and material composition of the structure, and an active patch is driven by a sinusoidal voltage sweep. When a PZT patch is subjected to an electric field, it produces a mechanical strain; and when it is stressed, it produces an electric charge. Since the patch is bonded to the structure, driving a patch deforms and vibrates the structure. The structure then produces a localized dynamic response. This structural system response is transferred back to the PZT patch, which in turn produces an electrical response. The electromechanical impedance method is based on the principle of electromechanical coupling between the active sensor and the structure, which allows researchers to assess local structural dynamics directly by interrogating a distributed sensor array. Because of mechanical coupling between the sensor and the host structure, this mechanical effect is picked up by the sensor and, through electromechanical coupling inside the active element, is reflected in electrical impedance measured at the sensor s terminals.

Martin, Richard E.↗

Supervisory control and health monitoring framework for large-scale additive manufacturing systems. Final CRADA report

ORNL worked with National Instruments (NI) to develop a large-scale, complex additive manufacturing (AM) systems framework for remote health monitoring and supervisory control. We found the framework, based on the Lincoln Electric Metal AM system located at ORNL’s MDF, capable of controlling the process, leading to improved part quality and digital twin creation.

42 ENGINEERING↗

Utilizing Non-Contact Stress Measurement System (NSMS) as a Health Monitor

Continuously monitor all 156 blades throughout the entire operating envelope without adversely affecting tunnel conditions or compromise compressor shell integrity, Calculate dynamic response and identify the frequency/mode to determine individual blade deflection amplitudes, natural frequencies, phase, and damping (Q), Log static deflection to build a database of deflection values at certain compressor conditions to use as basis for real-time online Blade Stack monitor, Monitor for stall, surge, flutter, and blade damage, Operate with limited user input, low maintenance cost, safe illumination of probes, easy probe replacement, and require little or no access to compressor.

Hayes, Terry↗