Search NASA⌕ Search

SEARCH · Search NASA

Results for “TEMPERATURE INDICATOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Supersonic jet plume interaction with a flat plate

Supersonic jet plume interaction with a flat plate was studied using a model scaled test apparatus designed to simulate plume/aircraft structure interaction for the cruise configuration. The generic configuration consisted of a rectangular supersonic nozzle of aspect ratio 7, and a large flat plate located beneath the nozzle at various nozzle plate distances; the plate was instrumented to measure surface dynamic pressure and mean wall temperature, with provisions for measurements of acceleration and strain on coupon size panels that could be inserted in the plate. Phase-averaged schlieren measurements revealed the presence of high-intensity acoustic emission from the supersonic plume above the plate, directed upstream; this radiation could be associated with the shock noise generation. Narrow band spectra of surface dynamic pressure show spectral peaks with amplitude levels reaching 1 psi, related to the screech tones. Temperature measurements indicated elevated surface temperatures in regions of high turbulence intensity.

Seiner, John M.↗

On the correlation of indices of vegetation and surface temperature over south-eastern Australia

Relationships between radiant surface temperature and vegetation indices for scenes with equal areas of forest and agricultural land use were studied using a Landsat TM scene during spring and an NOAA AVHRR scene during summer. The relationships between T sub R and the normalized difference (ND) index of vegetation for agricultural land use were different from those for forests. At the same T sub R, the forest had lower near infrared reflectance. This caused the ND of forests to fall below the T sub R/ND relationships formed by agricultural land use. This difference between forest and agricultural land use did not exist when visible reflectance was used as the index of vegetation.

Smith, R. C. G.↗

Elevated temperature tensile and creep behavior of a SiC fiber-reinforced titanium metal matrix composite

In this research program, the tensile properties and creep behavior in air of (0)(sub 4), (0/90)(sub s) and (90)(sub 4) SCS-9/Beta 21S composite layups with 0.24 volume fraction fiber were evaluated. Monotonic tensile tests at 23, 482, 650 and 815 C yielded the temperature dependence of the elastic modulus, proportional limit, ultimate tensile strength and total strain at failure. At 650 C, the UTS of the (0)(sub 4) and (0/90)(sub s) layups decreases by almost 50 percent from the room temperature values, indicating that operating temperatures should be less than 650 C to take advantage of the specific tensile properties of these composites.

Thurston, Rita J.↗

Method and system to measure gas flow

A system for measuring gas flow generally including a passive acoustic wave generator disposed in a gas flow stream to passively generate an audio signal through vortex shedding, a sound capturing instrument disposed outside the gas stream to produce an electrical signal representative of the acoustic signal, a temperature sensor to obtain temperature measurements indicative of the temperature of the gas flow stream and a control system for determining the gas flow, such as velocity or flow rate, as a function of the acquired acoustic and temperature measurements. The acoustic wave generator includes a corrugated flow channel whose geometric design is so tuned to generate an acoustic emission whose frequency signature varies as a function of the gas flow velocity. The control system may acquires time-domain acoustic data, and process that data to obtain a frequency-domain representation from which gas velocity or gas flow rate can be determined.

Cetiner, Mustafa S.↗

Temperature of Suprathermal Electron Strahl at ACE as an Indicator of Solar Coronal Origin Temperature [Slides]

Determine the effectiveness of using electron strahl temperature to infer coronal source temperature. Suprathermal electron strahl temperature derived from measurements at 1 AU does retain information regarding the coronal source temperature from which it originates. This correlation is most strongly measured during the leading edges of coronal hole events but is generally also present in full event measurements. This correlation is also observed in CME events during a coronal hole.

79 ASTRONOMY AND ASTROPHYSICS↗

Integrated Heat Exchanger-Phase Change Material Thermal Energy Storage System

The purpose of this study is to experimentally investigate the thermal performance of an innovative thermal energy storage (TES) system that combines the advantages of the phase-change material (PCM)/graphite foam latent heat TES medium developed at Argonne National Laboratory (Argonne) and the internally supported plate-fin (ISPE) cell architecture heat transfer fluid (HTF) flow channels developed at Brayton Energy (Brayton). Several essential tasks were accomplished: (1) Thermal property characterization. Thermal properties of the graphite foam were characterized, providing necessary data for experimental result analysis and numerical simulation. (2) Design and optimization of lab-scale test module. Based on Brayton’s full-scale heat exchanger (HX)-TES system, the experimental test module was designed, optimized, and fabricated. (3) Thermal performance testing and data analysis. Five cycle tests were successfully conducted—including one with approximately 3.5 psig of pressure applied to the diaphragms—to investigate the thermal performance of the experimental test module for charging and discharging. Temperature profiles were generated for each charging test and discharging test as a function of time. The temperature profiles clearly show three TES stages: sensible heat (temperature increase), latent heat (melting), and sensible heat (temperature increase) for the charging process. Similarly, the temperature profiles clearly show three thermal energy release stages: sensible heat (temperature decrease), latent heat (solidification), and sensible heat (temperature decrease). Melting and solidification of the PCM generally occurred in relatively narrow temperature ranges, indicated by the flattened temperature regions in the temperature profiles. These phase changes ranged approximately 3°C for melting and 3.5°C for solidification. The charging and discharging temperature profiles were similar for similar experimental parameter tests whether or not pressure was applied to the diaphragm to eliminate the gap between the HX surface and the TES subsystem. This indicates that the effect of a small gap between the HX surface and the TES subsystem is insignificant for charging and discharging. (4) Comparison of experimental data and simulation results. We compared the experimental data to the numerical simulation results. Numerical simulations were conducted by using the ANSYS FLUENT 2019 R3 commercial computational fluid dynamics software. The predicted phase-change times agreed reasonably well with those from the experimental data. In most cases, the estimated time differences between the relative phase changes were within 16%. The predicted start and end times for the charging process agreed well with those from the experimental data. However, the simulation results showed earlier start and end times than the experimental data for the discharging process. Overall, the experimental data and its comparison with the simulation predictions verified the technical viability of the integrated ISPF HX-PCM/graphite foam latent-heat TES system.

25 ENERGY STORAGE↗

Uncovering metallic glasses hidden vacancy-like motifs using machine learning

Vacancies are a ubiquitous type of defect in crystalline materials that can affect their properties and behavior, including atomic diffusivity, deformation processes, thermal conductivity, and electrical conductivity. While well-defined in crystals, it is challenging to identify such topological footprints in the amorphous structure of metallic glasses (MGs). Here, we uncover an unforeseen vacancy-like structural motif named Q7, which refers to an atomic Voronoi polyhedron with seven quadrangular faces, by investigating MG local atomic configurations with the help of machine learning. The Q7 motif exhibits characteristics similar to crystalline vacancies and plays a significant role in short-range structural disorder in MGs. The atoms at the center of the Q7 motif display larger local entropy, atomic volume, and local tension. Additionally, its concentration follows an Arrhenius-like relationship with temperature, accurately indicating the glass transition temperature, and is strongly correlated with the yield and failure of MGs during mechanical deformation. The discovery of the Q7 motif provides new insights into understanding the intricate relationship between local disorder and structural relaxation in MGs, offering a remarkable ability to predict their thermal and mechanical behavior. This potentially paves the way for enhancements in the design and manufacturing processes of MGs and other amorphous materials.

36 MATERIALS SCIENCE↗

Effect of surface roughness on phase transition timing in megaampere pulsed-power–driven exploding conductors

An understanding of material phase transitions in megaampere pulsed-power–driven exploding conductors is important for predicting the growth of hydrodynamic instabilities in magneto-inertial fusion concepts. Here, this study analyzes phase transitions in electrical conductor explosions using 1D Lagrangian and 2D arbitrary Lagrangian–Eulerian resistive magnetohydrodynamic simulations to show that micrometer-scale surface roughness can lead to the electrothermal instability (ETI), a feedback effect that concentrates resistive heating and leads to early melting and ablation. Simulations of the Mykonos electrothermal instability II (METI-II) experiment show melting begins 19% sooner for machined rods with micrometer-scale surface roughness than for rods without these features. The surface magnetic field is 41 T around the initial region of melt, representing a lower magnitude than both the 86 T from 1D simulations and the 85 T threshold reported elsewhere. In 2D simulations with micrometer-scale surface roughness, temperature measurements indicate the critical point temperature of aluminum is reached 17% faster in comparison with 1D simulations. Values from 2D simulations with surface roughness align with predictions from ETI theory, and the observed temperature redistribution further supports the ETI as an underlying mechanism. Simulation results are validated against experimental photonic Doppler velocimetry data. This study shows 1D simulations are adequate to model conductors with sub-micrometer-scale surface roughness in this high-energy-density regime; however, 2D or 3D simulations are required to capture the full range of physics for accurately describing phase transitions in conductors with micrometer-scale or larger surface roughness.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Performance of Windows in Walls With Continuous Insulation

Window openings in walls are a significant contributor to poor thermal performance because of thermal bridging through the framing members (e.g., studs, joists, plates, bracing) and because windows lack the thermal properties of insulation. Window installation guidance for walls with continuous insulation (CI) is critical for continued market growth of this energy efficiency technology. This research project offers window manufacturers a starting point and a potential path toward developing installation instructions for windows over CI. The objectives of the research include evaluating the common method for installing windows in walls with CI, as well as establishing acceptance criteria for evaluating the performance of windows installed in walls with and without CI. The research measures: 1. The performance characteristics (e.g., water management, structural integrity) of windows in walls without CI. 2. The performance of different thicknesses and types of CI used in walls. 3. The performance of different types of window assemblies (e.g., double-hung windows, mulled double-hung windows, mulled casement windows, and slider windows) installed over CI. 4. The performance of window flange types (e.g., rigid mounting and less robust flanges) installed over CI. 5. Installing windows over CI using baseline installation instructions versus window manufacturer installation instructions. The project’s sequential testing protocol consists of the following: • A water penetration resistance testing adapted from two ASTM standards: E331 (uniform static air pressure in four steps) and E547 (cyclic static air pressure) • A temperature cycling adapted from ASTM E2264 Method B (convective hot air) • A service condition wind loading test adapted from ASTM E330 • A six-month vertical displacement observation phase prior to the structural performance testing • A final water penetration resistance test after vertical displacement observation • A structural performance test adapted from ASTM E330. Key research findings include: • The criterion for passing a water penetration resistance test is that there is no water overflowing at the interior face of the studs. If there is any bubbling or slight pooling of water at the sill, then it must recede after the pressure is removed. Excessive leakage and/or water leaking to the interior face of the framing around the window constitutes a failure. • All single double-hung windows installed directly to lumber or over oriented strand board passed all test protocols. • For most wall specimens, the test results showed that the use of foam sheathing did not affect the performance of the window for water leakage. • All wall specimens underwent temperature cycling. The results indicated that temperature cycling had little to no effect on windows installed over foam sheathing. • For wall specimens that underwent six-month vertical displacement monitoring, the results showed that windows installed over foam sheathing do not sag over time. • The single-hung and double-hung windows installed using window manufacturer installation instructions passed the structural performance test, compared to failures observed in windows that were installed using generic installation instructions. The generic and manufacturer installation methods differed on the following construction details: type of fasteners, fastening patterns on the flanges, and window shimming details. • Additional testing is required to determine methods to improve structural pressure performance of slider windows. Potential solutions that would require additional testing may include fastener spacing, different types of fasteners, masonry window clips, construction adhesive, foam sealant, stronger window flange material, and/or straps.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Monitoring System for Crimean Congo Hemorrhagic Fever Epidemiology Studies in Afghanistan

In the last few years, tick-borne diseases have been reported as a resurging in the Middle East. Crimean-Congo hemorrhagic fever (CCHF) is endemic in the Middle East, including Turkey, Iran, Afghanistan and Pakistan. Recent studies have explored the causal link between environmental and disease incidence patterns by correlating remote sensing indicators (surface temperature, rainfall, and vegetation indices of plant photosynthetic activity) with spatially explicit epidemiological data. We combined the monitoring of environmental data at monthly temporal resolutions with available reports of confirmed CCHF cases to identify the environmental properties of endemic regions and quantify those properties to CCHF risk. We also conducted a sero-prevalence survey in a sample of households (human and animal specimens) in 9 villages in Engil district surrounding Herat province, in western Afghanistan. We present analysis results from our study villages and validate the associated environmental conditions as predictive for human disease occurrences. Risk prediction is critical for anticipating the type and potential impact of disease threats for timely response action.

Mustafa, M.↗

CROCUS Low Cost All-in-One Weather Station AMB-001 Data Argonne National Laboratory Prairie Site

The Ambient Weather WS-2902D (AMB) is a low cost weather station that has become very useful for filling data gaps in harder to deploy locations. These low cost weather stations collect 13 second data, which is averaged to a five minute data output available to users through an API key. The data files contain measurements for precipitation, temperature, wind chill/heat index, relative humidity, dew point, UV index, solar radiation, wind speed, wind direction, wind gust, and with an external particulate matter 2.5 (PM 2.5) sensor. Having all of these measurements in one condense system allows for fast deploying and dense network capabilities. Three of the AMB weather stations were deployed at the Argonne Testbed for Multiscale Observational Science (ATMOS), a 20-acre prairie site at Argonne National Laboratory in Lemont, Illinois. The instruments are denoted by their three digit identifier (CMS-AMB-xxx) format. The data is presented as daily NetCDF (.nc) files, each containing approximately 24 hours of observations. Files follow the naming convention of: the project (CROCUS), location (atmos), instrument name (CMS-AMB-001), data level (raw, a1), and date (year, month, day). The NetCDF format can be accessed using common scientific software such as Python using xarray, netCDF4 or ACT-DOE.

54 ENVIRONMENTAL SCIENCES↗

CROCUS Low Cost All-in-One Weather Station AMB-004 Data Argonne National Laboratory Prairie Site

The Ambient Weather WS-2902D (AMB) is a low cost weather station that has become very useful for filling data gaps in harder to deploy locations. These low cost weather stations collect 13 second data, which is averaged to a five minute data output available to users through an Application Programming Interface (API) key. The data files contain measurements for precipitation, temperature, wind chill/heat index, relative humidity, dew point, UV index, solar radiation, wind speed, wind direction, wind gust, and with an external particulate matter 2.5 (PM 2.5) sensor. Having all of these measurements in one condense system allows for fast deploying and dense network capabilities. Three of the AMB weather stations were deployed at the Argonne Testbed for Multiscale Observational Science (ATMOS), a 20-acre prairie site at Argonne National Laboratory in Lemont, Illinois. The instruments are denoted by their three digit identifier (CMS-AMB-xxx) format. The data is presented as daily NetCDF (.nc) files, each containing approximately 24 hours of observations. Files follow the naming convention of: the project (CROCUS), location (atmos), instrument name (CMS-AMB-004), data level (raw, a1), and date (year, month, day). The NetCDF format can be accessed using common scientific software such as Python using xarray, netCDF4 or ACT-DOE.

EARTH SCIENCE > ATMOSPHERE > AEROSOLS > PARTICULAT↗

Apparatus Would Measure Temperatures Of Ball Bearings

Rig for testing ball bearings under radial and axial loads and measuring surface temperatures undergoing development. Includes extensible thermocouples: by means of bellows as longitudinal positioners, thermocouples driven into contact with bearing balls to sense temperatures immediately after test run. Not necessary to disassemble rig or to section balls to obtain indirect indications of maximum temperatures reached. Thermocouple measurements indicate temperatures better than temperature-sensitive paints.

Gibson, John C.↗

The Sensitivity of PBX 9502 to Drilling Operations

Polymer-bonded explosive (PBX) 9502 (95% TATB, 5% Kel-F 800 by weight) is dry-drilled on a CNC milling machine and its thermomechanical response to varying feed rates, drilling speeds, and peck depths with 4 mm and 5 mm diameter drill bits is investigated. The tested samples are affixed to a force sensor that enables recording temporally resolved cutting forces and torques, and a drill-embedded thermocouple yields local temperature data. From the data, an empirical relationship between temperature changes and feed per revolution is developed, which reveals reduced temperatures in higher feed per revolution regimes for PBX 9502. The observed relationship allows extrapolating to temperatures for other hole diameters, indicating increased temperature for smaller diameter drilling across the board. Additional testing was performed with PBX 9501 (95% HMX, 2.5% Estane®, 2.5% BDNPA/BDNPF by weight), albeit over a reduced parameter space, which revealed the opposite behavior for the feed per revolution temperature dependence. It is concluded that both PBX 9502 and PBX 9501 can be dry-drilled efficiently beyond the limits of presently applicable US-DOE standards, where cutting interface temperatures remain far below material critical temperatures. Finally, data reveals that coolant usage in the drilling process for these materials provides a wide safety margin.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗