Search NASA⌕ Search

SEARCH · Search NASA

Results for “TIME DISCRIMINATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Molecularly engineering polymeric membranes for H 2 / CO 2 separation at 100–300 °C

Over the last two decades, polymers with superior H 2 /CO 2 separation properties at 100–300 °C have gathered significant interest for H 2 purification and CO 2 capture. This timely review presents various strategies adopted to molecularly engineer polymers for this application. We first elucidate the Robeson's upper bound at elevated temperatures for H 2 /CO 2 separation and the advantages of high-temperature operation (such as improved solubility selectivity and absence of CO 2 plasticization), compared with conventional membrane gas separations at ~35 °C. Second, we describe commercially relevant membranes for the separation and highlight materials with free volumes tuned to discriminate H 2 and CO 2 , including functional polymers (such as polybenzimidazole) and engineered polymers by cross-linking, blending, thermal treatment, thermal rearrangement, and carbonization. Third, we succinctly discuss mixed matrix materials containing size-sieving or H 2 -sorptive nanofillers with attractive H 2 /CO 2 separation properties.

42 ENGINEERING↗

Exhaled breath biomarkers of influenza infection and influenza vaccination

Respiratory viral infections are considered a major public health threat, and breath metabolomics can provide new ways to detect and understand how specific viruses affect the human pulmonary system. In this pilot study, we characterized the metabolic composition of human breath for an early diagnosis and differentiation of influenza viral infection, as well as other types of upper respiratory viral infections. We first studied the non-specific effects of planned seasonal influenza vaccines on breath metabolites in healthy subjects after receiving the immunization. We then investigated changes in breath content from hospitalized patients with flu-like symptoms and confirmed upper respiratory viral infection. The exhaled breath was sampled using a custom-made breath condenser, and exhaled breath condensate (EBC) samples were analysed using liquid chromatography coupled to quadruplole-time-of-flight mass spectrometer (LC-qTOF). All metabolomic data was analysed using both targeted and untargeted approaches to detect specific known biomarkers from inflammatory and oxidative stress biomarkers, as well as new molecules associated with specific infections. We were able to find clear differences between breath samples collected before and after flu vaccine administration, together with potential biomarkers that are related to inflammatory processes and oxidative stress. Moreover, we were also able to discriminate samples from patients with flu-related symptoms that were diagnosed with confirmatory respiratory viral panels (RVPs). RVP positive and negative differences were identified, as well as differences between specific viruses defined. These results provide very promising information for the further study of the effect of influenza A and other viruses in human systems by using a simple and non-invasive specimen like breath.

60 APPLIED LIFE SCIENCES↗

Characterization of 6 Li-loaded pulse-shape-discriminating plastic scintillators

Lithium-loaded organic plastic scintillators combine sensitivity to γ rays with the ability to detect both fast and slow neutrons, making them valuable for applications in nuclear security and in basic nuclear and particle physics. The goal of this work is to characterize the neutron response of two custom lithium-loaded organic plastic scintillators developed at Lawrence Livermore National Laboratory. Both are ternary polystyrene-based formulations containing 1.5 wt.% 6 Li salts of isobutyric acid, but they differ in their primary and secondary dye compositions: one uses m-terphenyl as the primary fluor and with Exalite 404 as the wavelength shifter, whereas the other uses 2,5-diphenyloxazole (PPO) and 9,10-diphenyl-anthracene, respectively. The temporal response of the scintillators was measured via time-correlated single photon counting for γ-ray and neutron events. The proton light yield was measured using the double time-of-flight technique from 1.3 to 15 MeV at the 88-Inch Cyclotron at Lawrence Berkeley National Laboratory. For the slow neutron response, an AmBe source moderated with polyethylene was used, and the light output from the 6 Li(n,α)t reaction was characterized. Differences in ionization quenching and temporal response were observed between the two materials with the PPO-containing scintillator exhibiting higher ionization quenching. These results provide performance benchmarks that can guide the design and optimization of future lithium-loaded plastic scintillators for use in basic science and applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Search for resonant and non-resonant Higgs boson pair production in the $b\overline{b}{\tau}^{+}{\tau}^{-}$ decay channel using 13 TeV $pp$ collision data from the ATLAS detector

A search for Higgs boson pair production in events with two $b$-jets and two $τ$-leptons is presented, using a proton–proton collision dataset with an integrated luminosity of 139 fb -1 collected at $\sqrt{s}$ = 13 TeV by the ATLAS experiment at the LHC. Higgs boson pairs produced non-resonantly or in the decay of a narrow scalar resonance in the mass range from 251 to 1600 GeV are targeted. Events in which at least one $τ$-lepton decays hadronically are considered, and multivariate discriminants are used to reject the backgrounds. No significant excess of events above the expected background is observed in the non-resonant search. The largest excess in the resonant search is observed at a resonance mass of 1 TeV, with a local (global) significance of 3.1$σ$ (2.0$σ$). Observed (expected) 95% confidence-level upper limits are set on the non-resonant Higgs boson pair-production cross-section at 4.7 (3.9) times the Standard Model prediction, assuming Standard Model kinematics, and on the resonant Higgs boson pair-production cross-section at between 21 and 900 fb (12 and 840 fb), depending on the mass of the narrow scalar resonance.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Novel imaging technique for thermal neutrons using a fast optical camera

A novel imaging technique for thermal neutrons using a fast optical camera is presented. Thermal neutrons are reacted with 6 Lithium to produce a pair of 2.73 MeV tritium and 2.05 MeV alpha particles, which in turn interact in a thin layer of LYSO crystal scintillator to produce a localized flash of light. These photons are directed by a pair of lenses to a micro-channel plate intensifier, and its output is connected to the optical camera, TPX3CAM. The results from the camera are reconstructed through a custom algorithm. Various cutting parameters were found through data analysis to eliminate the background, and they were shown effective in matching the simulated rate of the neutron source. The system is fast with 40 ns decay time and allows free-space light collection, both vastly enhances flexibility of neutron detection.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Black hole–neutron star mergers: The first mass gap and kilonovae

Observations of X-ray binaries indicate a dearth of compact objects in the mass range from ~2 –5 M ⊙ . The existence of this (first mass) gap has been used to discriminate between proposed engines behind core-collapse supernovae. From LIGO/Virgo observations of binary compact remnant masses, several candidate first mass gap objects, either neutron stars (NSs) or black holes (BHs), were identified during the O3 science run. Motivated by these new observations, we study the formation of BH-NS mergers in the framework of isolated classical binary evolution, using population synthesis methods to evolve large populations of binary stars (Population I and II) across cosmic time. We present results on the NS to BH mass ratios (q = M NS /M BH ) in merging systems, showing that although systems with a mass ratio as low as q = 0.02 can exist, typically BH-NS systems form with moderate mass ratios q = 0.1 –0.2. If we adopt a delayed supernova engine, we conclude that ~30% of BH-NS mergers may host at least one compact object in the first mass gap (FMG). Even allowing for uncertainties in the processes behind compact object formation, we expect the fraction of BH-NS systems ejecting mass during the merger to be small (from ~0.6 –9%). In our reference model, we assume: (i) the formation of compact objects within the FMG, (ii) natal NS/BH kicks decreased by fallback, (iii) low BH spins due to Tayler-Spruit angular momentum transport in massive stars. We find that ≲1% of BH-NS mergers will have any mass ejection and about the same percentage will produce kilonova bright enough to have a chance of being detected with a large (Subaru-class) 8 m telescope. Interestingly, all these mergers will have both a BH and an NS in the FMG.

79 ASTRONOMY AND ASTROPHYSICS↗

Optimization of X-ray event screening using ground and in-orbit data for the Resolve instrument onboard the XRISM satellite

The X-Ray Imaging and Spectroscopy Mission (XRISM) satellite was successfully launched and put into a low-Earth orbit on September 6, 2023 (UT). The Resolve instrument onboard XRISM hosts an X-ray microcalorimeter detector, which was designed to achieve a high-resolution ( ≤ 7 eV FWHM at 6 keV), high-throughput, and non-dispersive spectroscopy over a wide energy range. It also excels in a low background with a requirement of < 2 × 10 -3 s -1 keV -1 (0.3 to 12.0 keV), which is equivalent to only one background event per spectral bin per 100-ks exposure. Event screening to discriminate X-ray events from background is a key to meeting the requirement. We present the result of the Resolve event screening using data sets recorded on the ground and in orbit based on the heritage of the preceding X-ray microcalorimeter missions, in particular, the Soft X-ray Spectrometer onboard ASTRO-H. We optimize and evaluate 19 screening items of three types based on (1) the event pulse shape, (2) relative arrival times among multiple events, and (3) good time intervals. We show that the initial screening, which is applied for science data products in the performance verification phase, reduces the background rate to 1.8 × 10 -3 s -1 keV -1 meeting the requirement. We further evaluate the additional screening utilizing the correlation among some pulse shape properties of X-ray events and show that it further reduces the background rate, particularly in the < 2 keV band. Over 0.3 to 12 keV, the background rate becomes 1.0 × 10 -3 s -1 keV -1 .

47 OTHER INSTRUMENTATION↗

When and Where Lithium Plating Occurs, Its Correlation with Microstructure Heterogeneity, and the Mechanisms That Initiate and Self-Regulate Electrochemical Heterogeneity (A02-0444)

A microstructure scale electrochemical LIB model was used to investigate lithium plating onset, material non-uniform utilization, and in-plane heterogeneities for an NMC-graphite full cell. Model predicts active material particle surface roughness and size distribution (respectively, non-uniform curvature within and between particles) initiate in-plane heterogeneity, and that particle size heterogeneity at the separator interface controls the lithium plating preferential deposition ("Where"). These in-plane heterogeneities are then exacerbated by through-plane heterogeneities induced at fast charge as electrolyte depletion occurs and concentrates intercalation reaction near the anode-separator interface. Also, magnitude and occurrence of lithium plating is controlled by effective, or macroscale, microstructure parameters ("When"). As local states of charge start to diverge between nearby active material regions, overpotential differences induced by OCP difference kick in and contribute to reduce these SOC local heterogeneities. However, for staged materials such as graphite, with OCP profile alternating between plateaus and varying regions, this balancing mechanism is, respectively, inactive and active. This leads to a dynamic, non-monotonic, in-plane heterogeneity time evolution for state of charge and Faraday current density, for which their respective in-plane heterogeneity magnitude alternates. Such behavior has been modeled both for the whole electrode at the microstructure scale and at the particle scale. In-plane heterogeneities are usually considered to be detrimental, as they result in material non-uniform utilization (i.e., under and over stressed regions) and earlier degradations. However, this work provides a more granular approach as it discriminates between a harmful in-plane heterogeneity (non-uniform curvature) that triggers SOC in-plane heterogeneity, and a beneficial in-plane heterogeneity (Faraday current density) that contributes to reduce SOC in-plane heterogeneity. This work comprehensively explains the mechanisms that initiate, exacerbate, and regulate heterogeneity at the microstructure scale, while providing some design suggestions to reduce both in-plane and through-plane heterogeneities, as summarized in the graphical abstract.

ADVANCED PROPULSION SYSTEMS↗

Exploring the Interaction of Amphiphilic Mycobacterial Lipoarabinomannan with Lipoproteins: Implications for Blood Based Diagnosis

Currently, over one-third of the global population is infected with tuberculosis (TB), one of the world’s most deadly infectious diseases. The current gold standard for TB diagnosis is microbiological culture, which can take up to 6-8 weeks, which is not conducive to timely treatment. There are no reliable diagnostics for TB. Disease manifestation and outcome of diagnostic tests for TB is influenced by co-morbidities such as HIV co-infection, further complicating diagnostics development. Thus, there is a need for reliable diagnostics for TB. This is especially true in pediatric populations where the differential disease presentation further complicates outcomes. This dissertation describes the development and evaluation of new tailored methods-lipoprotein capture and membrane insertion- for the discriminative detection of an amphiphilic mycobacterial biomarker, lipoarabinomannan (LAM), for diagnosis of TB in adult and pediatric populations. LAM is released by Mycobacterium tuberculosis during active infection and associates with serum lipoproteins such as high and low density lipoproteins (HDL/LDL) in the human host. The guiding hypothesis of this work is that the vi sequestration of LAM in immune complexes and by lipoprotein carriers in the host contributes to difficulty in detection of the amphiphilic antigen in blood. To this end, we have evaluated the use of tailored amphiphile detection assays to process and measure sequestered LAM in host blood, and examined the application of this methodology in adults and children with TB disease. In addition, we have developed and studied an in vitro cell model to further extrapolate the impact of association of LAM with host carriers on its ability to induce innate immune processes, in order to better refine and design strategies for its direct detection. Overall, our conclusions indicate that the amphiphilic biochemistry of LAM and its interaction with lipoproteins is a feature which should be taken into account for the effective development of diagnostics.

59 BASIC BIOLOGICAL SCIENCES↗

Two-tooth bosonic quantum comb for temporal-correlation sensing

We introduce a two-tooth bosonic quantum comb that captures the sequential interactions between a thermal absorber and a long-lived coherent probe. The comb provides a causal, multi-time description of coherence transport, tracking how the probe records both instantaneous fluctuations and their temporal correlations. Using a process-tensor formulation, we derive closed form expressions showing that interference between the two interaction windows generates a non-monotonic memory response that reflects a fundamental competition between the absorbers thermal population and its dynamical correlations. By sweeping the temporal separation between the interaction windows, the probe directly samples the absorbers population correlator, enabling bosonic noise spectroscopy that discriminates Markovian temperature noise from slow or spectrally structured fluctuations. The approach is readily compatible with circuit-QED platforms and offers a general method for probing fluctuating bosonic environments.

Zhu, Shaojiang [Fermilab]↗

Load Profile Inpainting for Missing Load Data Restoration and Baseline Estimation

This paper introduces a Generative Adversarial Nets (GAN) based, Load Profile Inpainting Network (Load-PIN) for restoring missing load data segments and estimating the baseline for a demand response event. The inputs are time series load data before and after the inpainting period together with explanatory variables (e.g., weather data). Here, we propose a Generator structure consisting of a coarse network and a fine-tuning network. The coarse network provides an initial estimation of the data segment in the inpainting period. The fine-tuning network consists of self-attention blocks and gated convolution layers for adjusting the initial estimations. Loss functions are specially designed for the fine-tuning and the discriminator networks to enhance both the point-to-point accuracy and realisticness of the results. We test the Load-PIN on three real-world data sets for two applications: patching missing data and deriving baselines of conservation voltage reduction (CVR) events. We benchmark the performance of Load-PIN with five existing deep-learning methods. Our simulation results show that, compared with the state-of-the-art methods, Load-PIN can handle varying-length missing data events and achieve 15-30% accuracy improvement.

14 SOLAR ENERGY↗

Conformation-specific synthetic intrabodies modulate mTOR signaling with subcellular spatial resolution

Subcellular compartmentalization is integral to the spatial regulation of mechanistic target of rapamycin (mTOR) signaling. However, the biological outputs associated with location-specific mTOR signaling events are poorly understood and challenging to decouple. Here, we engineered synthetic intracellular antibodies (intrabodies) that are capable of modulating mTOR signaling with genetically programmable spatial resolution. Epitope-directed phage display was exploited to generate high affinity synthetic antibody fragments (Fabs) against the FKBP12–Rapamycin binding site of mTOR (mTOR FRB ). We determined high-resolution crystal structures of two unique Fabs that discriminate distinct conformational states of mTOR FRB through recognition of its substrate recruitment interface. By leveraging these conformation-specific binders as intracellular probes, we uncovered the structural basis for an allosteric mechanism governing mTOR complex 1 (mTORC1) stability mediated by subtle structural adjustments within mTOR FRB . Furthermore, our results demonstrated that synthetic binders emulate natural substrates by employing divergent yet complementary hydrophobic residues at defined positions, underscoring the broad molecular recognition capability of mTOR FRB . Intracellular signaling studies showed differential time-dependent inhibition of S6 kinase 1 and Akt phosphorylation by genetically encoded intrabodies, thus supporting a mechanism of inhibition analogous to the natural product rapamycin. Finally, we implemented a feasible approach to selectively modulate mTOR signaling in the nucleus through spatially programmed intrabody expression. These findings establish intrabodies as versatile tools for dissecting the conformational regulation of mTORC1 and should be useful to explore how location-specific mTOR signaling influences disease progression.

Science & Technology - Other Topics↗

Measuring the electron Yukawa coupling via resonant s-channel Higgs production at FCC-ee

The Future Circular Collider (FCC-ee) offers the unique opportunity of studying the Higgs Yukawa coupling to the electron, \(y_\mathrm {e}\) , via resonant s -channel production, \(\mathrm {e^+e^-}\rightarrow \mathrm {H}\) , in a dedicated run at \(\sqrt{s} = m_\mathrm {H}\) . The signature for direct Higgs production is a small rise in the cross sections for particular final states, consistent with Higgs decays, over the expectations for their occurrence due to Standard Model (SM) background processes involving \(\mathrm {Z}^*\) , \(\gamma ^*\) , or t -channel exchanges alone. Performing such a measurement is remarkably challenging for four main reasons. First, the low value of the e \(^\pm \) mass leads to a tiny \(y_\mathrm {e}\) coupling and correspondingly small cross section: \(\sigma _\mathrm {ee\rightarrow H} \propto m_\mathrm {e}^2 = 0.57\) fb accounting for initial-state \(\gamma \) radiation. Second, the \(\mathrm {e^+e^-}\) beams must be monochromatized such that the spread of their centre-of-mass (c.m.) energy is commensurate with the narrow width of the SM Higgs boson, \(\varGamma _\mathrm {H} = 4.1\) MeV, while keeping large beam luminosities. Third, the Higgs mass must also be known beforehand with a few-MeV accuracy in order to operate the collider at the resonance peak, \(\sqrt{s} = m_\mathrm {H}\) . Last but not least, the cross sections of the background processes are many orders-of-magnitude larger than those of the Higgs decay signals. A preliminary generator-level study of 11 Higgs decay channels using a multivariate analysis, which exploits boosted decision trees to discriminate signal and background events, identifies two final states as the most promising ones in terms of statistical significance: \(\mathrm {H}\rightarrow gg\) and \(\mathrm {H}\rightarrow \mathrm {W}\mathrm {W}^*\!\rightarrow \ell \nu \) + 2 jets. For a benchmark monochromatization with 4.1-MeV c.m. energy spread (leading to \(\sigma _\mathrm {ee\rightarrow H} = 0.28\) fb) and 10 ab \(^{-1}\) of integrated luminosity, a \(1.3\sigma \) signal significance can be reached, corresponding to an upper limit on the e \(^\pm \) Yukawa coupling at 1.6 times the SM value: |y e | < 1.6|y e SM | at 95% confidence level, per FCC-ee interaction point per year. Directions for future improvements of the study are outlined.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

R “SHINY” GUI DEVELOPMENT FOR URANIUM ISOTOPIC ANALYSIS WITH MATRIX-ASSISTED IONIZATION MASS SPECTROMETRY

The international nuclear safeguards community continues to seek rapid, accurate, and precise characterization capabilities for the in-field measurement of uranium isotopic compositions in nuclear facilities. Mass spectrometry (MS) is considered the “gold standard” for analysis of relatively long-lived actinides such as uranium (U) and plutonium; however, conventional MS analysis often requires time consuming sample preparation and complex analytical methodologies that are difficult to perform in-field or in-facility. Matrix assisted ionization (MAI) is a novel ambient ionization MS technique (i.e., MAI-MS) that potentially addresses these challenges due to the relative simplicity of the ionization phenomenon and ruggedness of ambient MS instrumentation. Savannah River National Laboratory (SRNL, USA) has demonstrated this technique for nanogram-level 235U/238U isotope ratio measurements within seconds, with percent-level analytical uncertainties capable of discriminating depleted, natural, and low-enriched uranium. Current experimental work on developing MAI methods for uranium isotopic analysis has been enabled by parallel development of a comprehensive MAI-MS data analysis suite at SRNL. Development of this bespoke data analysis software was necessary because commercially available ambient MS software is poorly suited for uranium isotope ratio measurement. The effort leverages the power of R, a popular open-source programming language, and Shiny, an R package providing tools for graphical user interface (GUI) and web interface coding. This software allows researchers without any programming experience to harness and utilize R’s considerable data analysis/visualization power.

LaBone, Elizabeth D.↗

Multi-parameter distributed fiber optic sensing using double-Brillouin peak fiber in Brillouin optical time domain analysis

In this paper, we demonstrate a multi-parameter fiber sensing system based on stimulated Brillouin scattering in a double-Brillouin peak specialty fiber with enhanced Brillouin gain response. The amplitude level of the second Brillouin gain peak, which originated from the higher-order acoustic modes, has been improved with an approximately similar amplitude level to the first Brillouin gain peak from the fundamental acoustic mode. Compared to other multi-Brillouin peak fibers presented in the literature, the proposed fiber significantly reduces the measured Brillouin frequency shift error, thus improving strain and temperature accuracies. By utilizing the sensitivity values of the strain and temperature associated with each Brillouin gain spectrum (BGS) peak, a successful discriminative measurement of strain and temperature is performed with an accuracy of ±13 μɛ, and ±0.5 °C, respectively. The proposed double-Brillouin peak fiber appears to be a possible alternative to other multi-BGS peak fibers, for instance, large effective area fiber and dispersion compensating fibers, which are inherently accompanied by large measurement errors due to the weak Brillouin gain values originating from the higher-order acoustic modes. The demonstrated results show different strain and temperature coefficients of 47 kHz/µɛ, 1.15 MHz/°C for peak 1 and 51 kHz/µɛ, 1.37 MHz/°C for peak 2. Moreover, the enhanced BGS peak gains having nearly the same amplitude levels enable the discriminative measurement of strain and temperature. Such fibers in Brillouin interrogation eliminate the need for complex monitoring setups and reduce measurement errors. We recommend that for long-distance natural gas pipeline monitoring, where discriminative strain and temperature measurement is crucial, the proposed double-Brillouin peak fiber can be highly beneficial.

47 OTHER INSTRUMENTATION↗

The electronic set-up for the scintillation light detection system of ICARUS-SBN at Fermilab

The ICARUS-T600 Liquid Argon (LAr) Time Projection Chamber (TPC) is presently used as the far detector of the Short Baseline Neutrino (SBN) program at Fermilab (USA) to search for a possible sterile neutrino signal with the Booster Neutrino Beam (BNB). We discuss a light detection system, based on 360 Hamamatsu R5912-MOD Photo-Multiplier Tubes (PMTs), which has been realized to detect vacuum ultraviolet (VUV) photons produced after the passage of ionizing particles in LAr. High performance electronics allows recording of the PMT signals and provides a fast discrimination for the exploitation of the scintillation light for trigger purposes. This system is fundamental for the TPC operation, contributing to the trigger system and for the 3D reconstruction of events.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thermal Characterization of Tl 2 LiYCl 6 :Ce (TLYC)

Tl 2 LiYCl 6 :Ce (TLYC) is a new dual-detection elpasolite scintillator that can detect and distinguish between gamma rays and neutrons using pulse shape discrimination (PSD). It has a higher density and Z -number than the more mature and well-known elpasolite Cs 2 LiYCl 6 :Ce (CLYC), causing it to have a significantly better gamma-ray stopping power. These properties make TLYC an attractive alternative to CLYC for resource-constrained applications where size and weight are important, such as space or national security applications. Such applications may be subjected to a wide range of temperatures, and therefore, TLYC's performance was characterized for the first time over a temperature range of -20 °C to +50 °C in 10 °C increments. TLYC's thermal response effects on light-output linearity with energy, gamma-ray photopeak energy resolution, detected neutron energy, pulse shapes, and figure of merit (FOM) is analyzed and reported. The light output of TLYC was found to be linear with energy over the tested temperature range and was observed to decrease with increasing temperature. The decay time of the scintillation light output was observed to decrease with decreasing temperature at short times, leading to a decreasing PSD FOM. The gamma-ray photopeak energy resolution was also observed to degrade with decreasing temperature, due to an asymmetric broadening of the photopeak at low temperatures.

36 MATERIALS SCIENCE↗

Prospects for detecting UF6 hydrolysis intermediates by mass spectrometry, resonance Raman, and NQR spectroscopy

Simulations are performed to consider several spectrometric and spectroscopic candidates for elucidating the mechanism of the hydrolysis of uranium hexafluoride (UF6). This study is among the first to benchmark the def-mTZVP basis sets for actinide-containing molecules, and it is shown to be a suitable basis set for surveying geometrical structures and vibrational spectra when used in conjunction with density functional theory. An experiment is proposed coupling mass spectrometric ion selection with vibrational spectroscopy, and supporting infrared and Raman spectral simulations demonstrate that ionization blue-shifts bands and can change their qualitative features. Ultraviolet resonance Raman is shown to have good prospects for discriminating U–O–U bridged intermediates, evidence for which was observed recently [L. E. McNamara et al., J. Phys. Chem. A 130, 775–786 (2026)]. As a more speculative approach, we also consider the prospect of addressing 233U or 235U nuclei by quadrupole resonance (NQR) spectroscopy for assigning early stage intermediate complexes. In doing so, we provide a first order-of-magnitude estimate for the collision-induced NQR signal for the UF6 dimer, which is of interest for the interpretation of a fast decoherence time observed in liquid-phase nuclear magnetic resonance. Having provided critical insights into the formation and stability of UF6 hydrolysis intermediates in previous studies, this computational spectroscopy survey is expected to help guide and expedite future laboratory campaigns.

Lutz, Jesse J. [Center for Computing Research, San↗