At least 271 records · Page 15

Novel principal component analysis tool based on python for analysis of complex spectra of time-of-flight secondary ion mass spectrometry

Time-of-flight secondary ion mass spectrometry (ToF-SIMS) is a powerful surface analysis tool, which can simultaneously provide elemental, isotopic, and molecular information with part per million (ppm) sensitivity. However, each spectrum may be composed of hundreds of ion signals, which makes the spectra data complex. Principal component analysis (PCA) is a multivariate analysis technique that has been widely used to figure out the variances among samples in ToF-SIMS spectra data analysis and is showing great success in the explanation of complex ToF-SIMS spectra. So far, several software tools have been developed for PCA of ToF-SIMS spectra; however, none of them are freely available. Such a situation leads to some difficulties in extending applications of PCA to various research fields. More importantly, it has long been challenging for common researchers to understand PCA plots and extract chemical differences among samples. In this work, we developed a new and flexible software tool (named “advanced spectra pca toolbox”) based on python for PCA of complex ToF-SIMS spectra along with an easy-to-read manual. It can generate data analysis reports automatically to explain chemical differences among samples, allowing less experienced researchers to easily understand tricky PCA results. Moreover, it is expandable and compatible with artificial intelligence/machine learning functions. Pure goethite and different lignin adsorbed goethite samples were used as a model system to demonstrate our new software tool, proving that our software tool can be readily used in complex spectra data processing. Our new software tool is open-source, convenient, flexible, and expandable. We expect this open-source tool will benefit the ToF-SIMS community.

47 OTHER INSTRUMENTATION↗

Charging and ion ejection dynamics of large helium nanodroplets exposed to intense femtosecond soft xray pulses

Ion ejection from charged helium nanodroplets exposed to intense femtosecond soft X-ray pulses is studied by single-pulse ion time-of-flight (TOF) spectroscopy in coincidence with small-angle X-ray scattering. Scattering images encode the droplet size and absolute photon flux incident on each droplet, while ion TOF spectra are used to determine the maximum ion kinetic energy, Ekin, of He+ j fragments (j = 1-4). Measurements span HeN droplet sizes between N similar to 10(7) and similar to 10(10) (radii R-0 = 78-578 nm), and droplet charges between similar to 9x10(-5) and similar to 3x10(-3) e/atom. Conditions encompass a wide range of ionization and expansion regimes, from departure of all photoelectrons from the droplet, leading to pure Coulomb explosion, to substantial electron trapping by the electrostatic potential of the charged droplet, indicating the onset of hydrodynamic expansion. The unique combination of absolute Xray intensities, droplet sizes, and ion Ekin on an event-by-event basis reveals a detailed picture of the correlations between the ionization conditions and the ejection dynamics of the ionic fragments. The maximum E-kin of He+ is found to be governed by Coulomb repulsion from unscreened cations across all expansion regimes. The impact of ion-atom interactions resulting from the relatively low charge densities is increasingly relevant with less electron trapping. The findings are consistent with the emergence of a charged spherical shell around a quasineutral plasma core as the degree of ionization increases. The results demonstrate a complex relationship between measured ion E-kin and droplet ionization conditions that can only be disentangled through the use of coincident single-pulse TOF and scattering data.

Helium↗

Volatile Organic Compounds in Bankhead National Forest (AMF3). August to September, 2025

The formation of atmospheric aerosols through the transformation of volatile organic compounds (VOCs) is a fundamental process in aerosol-climate interactions, as these particles serve as cloud condensation nuclei and ultimately influence Earth’s radiative balance. However, there remains a critical need to quantify the effects of multiple coexisting VOC precursors on aerosol formation beyond the limitations of laboratory-scale studies. This research aims to advance the mechanistic understanding of secondary organic aerosol formation in the southeastern United States by investigating interactions among coexisting VOC precursors observed at the third ARM Mobile Facility located in the Bankhead National Forest. The dataset was generated from the deployment of Oak Ridge National Laboratory’s PTR-TOF 6000 X2 Proton Transfer Reaction Time-of-Flight Mass Spectrometer (PTR-ToF-MS) for the real-time, continuous monitoring of VOCs from August 21 to September 15, 2025. To minimize sampling artifacts and compound losses, the PTR-ToF-MS inlet was connected to the cabin flow line by replacing the existing Tygon tubing with 1/2-inch outer diameter perfluoroalkoxy (PFA) tubing. The instrument operated on an hourly measurement cycle consisting of 8 minutes of zero-air measurements followed by 52 minutes of ambient air sampling, with a temporal resolution of 10 seconds. The dataset includes concentrations, reported in ppb, of methanol, acetone, acetonitrile, isoprene, methyl vinyl ketone and methacrolein (MVK + MACR), monoterpenes, benzene, toluene, and catechol.

Atmospheric concentration of volatile organic comp↗

An LC-IMS-MS Platform Providing Increased Dynamic Range for High-Throughput Proteomic Studies

A high-throughput approach and platform using 15 minute reversed-phase capillary liquid chromatography (RPLC) separations in conjunction with ion mobility spectrometry-mass spectrometry (IMS-MS) measurements was evaluated for the rapid analysis of complex proteomics samples. To test the separation quality of the short LC gradient, a sample was prepared by spiking twenty reference peptides at varying concentrations from 1 ng/mL to 10 µg/mL into a tryptic digest of mouse blood plasma and analyzed with both a LC-Linear Ion Trap Fourier Transform (FT) MS and LC-IMS-TOF MS. The LC-FT MS detected thirteen out of the twenty spiked peptides that had concentrations ≥100 ng/mL. In contrast, the drift time selected mass spectra from the LC-IMS-TOF MS analyses yielded identifications for nineteen of the twenty peptides with all spiking level present. The greater dynamic range of the LC-IMS-TOF MS system could be attributed to two factors. First, the LC-IMS-TOF MS system enabled drift time separation of the low concentration spiked peptides from the high concentration mouse peptide matrix components, reducing signal interference and background, and allowing species to be resolved that would otherwise be obscured by other components. Second, the automatic gain control (AGC) in the linear ion trap of the hybrid FT MS instrument limits the number of ions that are accumulated to reduce space charge effects, but in turn limits the achievable dynamic range compared to the TOF detector.

biomarker discovery↗

CF Neutron Time of Flight Transmission for Material Identification for weapons Trainers

The neutron transmission, elastic scattering, and non-elastic reactions can be used to distinguish various isotopes. Neutron transmission as a function of energy can be used in some cases to identify materials in unknown objects. A time tagged californium source that provides a fission spectrum of neutrons is a useful source for neutron time-of-flight (TOF) transmission measurements. Many nuclear weapons trainer units for a particular weapons system (no fissile, but of same weight and center of gravity) in shipping containers were returned to the National Nuclear Security Administration Y-12 National Security Complex in the mid 1990s. Nuclear Materials Identification System (NMIS) measurements with a time tagged californium neutron source were used to verify that these trainers did not contain fissile material. In these blind tests, the time distributions of neutrons through the containers were measured as a function of position to locate the approximate center of the trainer in the container. Measurements were also performed with an empty container. TOF template matching measurements were then performed at this location for a large number of units. In these measurements, the californium source was located on one end of the container and a proton recoil scintillator was located on the other end. The variations in the TOF transmission for times corresponding to 1 to 5 MeV were significantly larger than statistical. Further examination of the time distribution or the energy dependence revealed that these variations corresponded to the variations in the neutron cross section of aluminum averaged over the energy resolution of the californium TOF measurement with a flight path of about 90 cm. Measurements using different thicknesses of aluminum were also performed with the source and detector separated the same distance as for the trainer measurements. These comparison measurements confirmed that the material in the trainers was aluminum, and the total thickness of aluminum through the trainers was determined. This is an example of how californium transmission TOF measurements can be used to identify materials.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Secondary Ion Mass Spectrometry (SIMS) for Chemical Characterization of Metal Halide Perovskites

Metal halide perovskite (MHP) solar cells have attracted much attention due to the rapidly growing power conversion efficiency that has reached 25.2% in a decade, comparable to established commercial photovoltaic modules. Compositional engineering is one of the most effective methods to boost the performance of MHP solar cells. Further improving the efficiency and the stability of MHP solar cells necessitates good understanding of the chemical–efficiency correlation and the chemical evolution during the degradation of MHP solar cells. In this regard, time-of-flight secondary ion mass spectrometry (ToF-SIMS) is a powerful tool to investigate the chemical aspect of MHPs and has played an important role in advancing the development of MHP optoelectronics. However, up to date, a review that can guide future utilization of ToF-SIMS in the MHP development is missing. In this paper, the capabilities of ToF-SIMS in MHP investigations are summarized and analyzed from simple material synthesis and chemical distribution to more complicated device operation mechanism and stability. The strength of ToF-SIMS in resolving important issues in this field, such as interface composition, ion migration, and degradation in MHP is highlighted. Finally, an outlook with an emphasis on making the utmost of ToF-SIMS in developing MHP devices is provided.

36 MATERIALS SCIENCE↗

Elemental analysis of air-sensitive frozen molten salt samples using an inert transfer chamber for LIBS/LA-ICP-TOF-MS analysis

A novel inert sample transfer system was developed and employed to enable, for the first time, the analysis of air-sensitive salt samples in a two-volume ablation cell using simultaneous laser-induced breakdown spectroscopy (LIBS) and laser ablation (LA)-inductively coupled plasma (ICP)-time-of-flight (TOF)-mass spectrometry (MS) analysis. Molten salts are of growing interest as a medium for advanced nuclear reactors and nuclear fuel reprocessing technologies continue to be developed around their use. However, compositional analysis of molten salt samples can be challenging because of their air-sensitive nature and varying solubilities leading to inaccurate measurements when digested. LA-based analysis provides an alternate method to digestion and can provide rapid elemental information with little sample preparation. In this study, LIBS and LA-ICP-TOF-MS were used to analyze the Ce content in frozen salt samples taken from a series of electrochemical experiments. Calibrations were built for each technique, and the resulting limits of detection for Ce were estimated to be 107 and 58 µg g −1 for LIBS and LA-ICP-TOF-MS, respectively. Test samples from the electrochemical experiments were analyzed using these calibrations. The results matched bulk digestion-based ICP-optical emission spectroscopy values, and daily trends in Ce concentration changes were identified. Additionally, the LIBS and LA-ICP-TOF-MS analysis was demonstrated for identifying microgram per gram levels of components and detecting trace contaminants. The impurities detected by LIBS included Al, Mg, Ca, and Na. The impurities detected by LA-ICP-TOF-MS included W, Ag, Al, Fe, Ni, Mo, Nd, Sm, Th, and U.

Andrews, Hunter B. [Oak Ridge National Laboratory ↗

The roles of the binodal curve and the spinodal curve in expansions from the supercritical state with flashing

Data extracted from time-of-flight (TOF) measurements made on steady-state He free jets at Göttingen already in 1986 and for pulsed Ne free jets investigated recently at Tel Aviv have been added to an earlier plot of terminal condensed-phase mass fraction x{sub 2∞} as a function of the dimensionless scaling parameter Γ. Γ characterizes the source (fluid species, temperature, pressure and throat diameter); values of x{sub 2∞} are extracted from TOF measurements using conservation of energy in the free-jet expansion. For nozzles consisting of an orifice in a thin plate; the extracted data yield 22 data points which are correlated satisfactorily by a single curve. The Ne free jets were expanded from a conical nozzle with a 20° half angle; the three extracted data points stand together but apart from the aforementioned curve, indicating that the presence of the conical wall influences significantly the expansion and hence the condensation. The 22 data points for the expansions via an orifice consist of 15 measurements with expansions from the gas-phase side of the binodal curve which crossed the binodal curve downstream from the sonic point and 7 measurements with expansions of the gas-phase product of the flashing which occurred after an expansion from the liquid-phase side of the binodal curve crossed the binodal curve upstream from the sonic point. The association of these 22 points with a single curve supports the alternating-phase model for flows with flashing upstream from the sonic point proposed earlier. In order to assess the role of the spinodal curve in such expansions, the spinodal curves for He and Ne were computed using general multi-parameter Helmholtz-free-energy equation-of-state formulations. Then, for the several sets of source-chamber conditions used in the free-jet measurements, thermodynamic states at key locations in the free-jet expansions (binodal curve, sonic point and spinodal curve) were evaluated, with the expansion presumed to be metastable from the binodal curve to the spinodal curve. TOF distributions with more than two peaks (interpreted earlier as superimposed alternating-state TOF distributions) indicated flashing of the metastable flow downstream from the binodal curve but upstream from the sonic point. This relatively early flashing is due apparently to destabilizing interactions with the walls of the source. If the expansion crosses the binodal curve downstream from the nozzle, the metastable fluid does not interact with surfaces and flashing might be delayed until the expansion reaches the spinodal curve. It is concluded that, if the expansion crosses the binodal curve before reaching the sonic point, the resulting metastable fluid downstream from the binodal curve interacts with the adjacent surfaces and flashes into liquid and vapor phases which expand alternately through the nozzle; the two associated alternating TOF distributions are superposed by the chopping process so that the result has the appearance of a single distribution with three peaks.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

An integrated time-of-flight versus residual energy subsystem for a compact dual ion composition experiment for space plasmas

We have developed a novel concept for a Compact Dual Ion Composition Experiment (CoDICE) that simultaneously provides high quality plasma and energetic ion composition measurements over 6 decades in ion energy in a wide variety of space plasma environments. CoDICE measures the two critical ion populations in space plasmas: (1) mass and ionic charge state composition and 3D velocity and angular distributions of ∼10 eV/q–40 keV/q plasma ions—CoDICE-Lo and (2) mass composition, energy spectra, and angular distributions of ∼30 keV–10 MeV energetic ions—CoDICE-Hi. CoDICE uses a common, integrated Time-of-Flight (TOF) versus residual energy (E) subsystem for measuring the two distinct ion populations. This paper describes the CoDICE design concept, and presents results of the laboratory tests of the TOF portion of the TOF vs. E subsystem, focusing specifically on (1) investigation of spill-over and contamination rates on the start and stop microchannel plate (MCP) anodes vs. secondary electron steering and focusing voltages, scanned around their corresponding model-optimized values, (2) TOF measurements and resolution and angular resolution, and (3) cross-contamination of the start and stop MCPs’ singles rates from CoDICE-Lo and -Hi, and (4) energy resolution of avalanche photodiodes near the lower end of the CoDICE-Lo energy range. We also discuss physical effects that could impact the performance of the TOF vs. E subsystem in a flight instrument. Finally, we discuss advantages of the CoDICE design concept by comparing with capabilities and resources of existing flight instruments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Diamond detectors for the TOTEM timing upgrade

This paper describes the design and the performance of the timing detector developed by the TOTEM Collaboration for the Roman Pots (RPs) to measure the Time-Of-Flight (TOF) of the protons produced in central diffractive interactions at the LHC . The measurement of the TOF of the protons allows the determination of the longitudinal position of the proton interaction vertex and its association with one of the vertices reconstructed by the CMS detectors. The TOF detector is based on single crystal Chemical Vapor Deposition (scCVD) diamond plates and is designed to measure the protons TOF with about 50 ps time precision. This upgrade to the TOTEM apparatus will be used in the LHC run 2 and will tag the central diffractive events up to an interaction pileup of about 1. A dedicated fast and low noise electronics for the signal amplification has been developed. The digitization of the diamond signal is performed by sampling the waveform. In conclusion, after introducing the physics studies that will most profit from the addition of these new detectors, we discuss in detail the optimization and the performance of the first TOF detector installed in the LHC in November 2015.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of the Tachyon Time-of-Flight PET Camera

We have constructed and characterized a time-of-flight Positron Emission Tomography (TOF PET) camera called the Tachyon. The Tachyon is a single-ring Lutetium Oxyorthosilicate (LSO) based camera designed to obtain significantly better timing resolution than the ~ 550 ps found in present commercial TOF cameras, in order to quantify the benefit of improved TOF resolution for clinically relevant tasks. The Tachyon's detector module is optimized for timing by coupling the 6.15 ×25 mm 2 side of 6.15 ×6.15 ×25 mm 3 LSO scintillator crystals onto a 1-inch diameter Hamamatsu R-9800 PMT with a super-bialkali photocathode. We characterized the camera according to the NEMA NU 2-2012 standard, measuring the energy resolution, timing resolution, spatial resolution, noise equivalent count rates and sensitivity. The Tachyon achieved a coincidence timing resolution of 314 ps +/- 20 ps FWHM over all crystal-crystal combinations. Experiments were performed with the NEMA body phantom to assess the imaging performance improvement over non-TOF PET. We find that the results show that at a matched contrast, incorporating 314 ps TOF reduces the standard deviation of the contrast by a factor of about 2.3.

47 OTHER INSTRUMENTATION↗

Advanced Mass Spectrometry for Proteomics and Other Biological Applications

The purpose of the collaboration between Agilent Technologies and Battelle is to integrate Battelle’s unique electrospray ionization ion mobility spectrometry (ESI/IMS) technology with Agilent’s state-of-art time of flight mass spectrometry (TOF MS) to design and fabricate multiple ESI/IMS/TOF MS instrument platforms for large scale demonstration of proteomics analyses. The development is aimed at the firm foundation for a premium new IMS/MS product for Agilent and the dissemination of important analytical advances for the scientific community Three initial prototype systems are planned to be utilized as part of this effort. These are as follows: - Prototype 1: This prototype will based upon the integration of Battelle’s existing IMS Version 3 front-end with the latest version of Agilent’s TOF instrument (the SEIKO TOF) that will include an upgraded high-speed ADC. - Prototype 2: This prototype will be based on the integration of Battelle’s more advanced IMS Version 4 front-end with an existing Agilent TOF system already installed at PNNL. - Prototype 3: This prototype will be based on the integration of a modified IMS Version 4 front-end with Agilent’s most advanced TOF instruments. The collaboration consists of four tasks based on the prototypes and these are: - Task 1. Assembly and Testing of Prototype 1 - Task 2. Assembly and Testing of Prototype 2 - Task 3. Fabrication, Assembly, and Testing of Prototype 3 - Task 4. Final report

Baker, Erin Shammel↗

Trade Study for Neutron Transport at Low Earth Orbit: Adding Fidelity to DIORAMA

The Distributed Infrastructure Offering Real-Time Access to Modeling and Analysis (DIORAMA) software provides performance modeling capabilities of the United States Nuclear Detonation Detection System (USNDS) with a focus on the characterization of Space-Based Nuclear Detonation Detection (SNDD) instrument performance [1]. A case study was done to add the neutron propagation capabilities of DIORAMA to low earth orbit (LEO), and compare the back-calculated incident energy from the time-of- ight (TOF) spectrum with the scored incident energy spectrum. As the scoring altitude lowers, the time increase due to scattering takes up much more of the fraction of total TOF; whereas at geosynchronous earth orbit (GEO), the time increase due to scattering is a negligible fraction of the total TOF [2]. The scattering smears out the TOF enough to make the back-calculation of the initial energy spectrum from the TOF spectrum very convoluted.

79 ASTRONOMY AND ASTROPHYSICS↗

Integrated Spatial, Spectral, & Temporal Optical Reflectance System for Precision Occupancy & Location Sensing to Improve Building Energy Efficiency

Buildings consume approximately 35% of the electricity used in the U.S. and building owners can significantly reduce this energy use by providing services like heating, electrical power and lighting only when people are present. The ARPAe funded program titled “INTEGRATED SPATIAL, SPECTRAL, & TEMPORAL OPTICAL REFLECTANCE SYSTEM FOR PRECISION OCCUPANCY & LOCATION SENSING TO IMPROVE BUILDING ENERGY EFFICIENCY” demonstrates how a low cost sensor technology developed for measuring distances can be used to count and locate occupants with a high degree of precision with a very low error rates. This platform tells a building control system where occupants are located (but not who they are) so that energy consuming services can be provided only when the services are needed by building occupants. The original proof of concept involved using low cost, commercially available time-of-flight (TOF) sensors that measure distance, but the performance of these existing sensors was lacking, as they could not operate properly in the presence of sunlight, which blinded the simple TOF sensors and limited their utility in buildings. This project proposed a powerful new class of TOF sensors that used state-of-the-art integrated circuit (IC) fabrication processes that combined advanced photonics with conventional silicon chip circuitry for improved sensor performance. An equally important part of this project was to find ways to maximize occupant count and location accuracy while using the fewest number of sensors possible, in order to keep costs low. By using building blueprints to create digital twins of commercial building spaces, the team developed new algorithms to maximize occupant count and tracking accuracy by properly locating the minimum number of sensors at just the right spots in the building. This capability not only minimizes system costs but also simplified sensor installation and system commissioning. Our simulations of our sensor networks for a range of commercial floorplan designs demonstrated that our installed cost target of $0.08/sqft was attainable, though not fully demonstrated during the project. Finally, we noted that the TOF sensor concept could provide a valuable role in health and eldercare by tracking patients without the need for worn sensors and would be useful for fall detection and other patient safety metrics, including tracking healthcare/patient interactions. We feel that, when fully developed, this new class of sophisticated TOF sensors and support software will be a powerful new approach to improving building energy efficiency based on occupant centric control platforms and will also open new levels of patient safety in healthcare operations. To realize this potential, the team formed the Troy Sensor Company LLC to oversee licensing of the programs patents and continue to seek commercialization of this program’s activity sensing technologies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Position-Dependent Neutron Time-of-Flight Deviation at VULCAN Diffractometer

In neutron diffraction, it is critical to precisely measure the lattice spacing, as it is an indicator of a material’s physical characteristics, such as lattice strain, thermal expansion, and phase structures. In time-of-flight (TOF) measurements, the lattice spacing is determined by the recorded TOF from a well-calibrated instrument. However, changes in neutron time-of-flight are sensitive to many factors, such as the alignment of instrument optics, temperature, sample positions, sample dimensions, internal strains, and chemical or physical heterogeneities at the grain level. At VULCAN (SNS, ORNL), which is a high-flux engineering neutron diffractometer, we used a 1-mm-diameter diamond powder sample to scan for changes in TOF by measuring d-spacing values at different sample positions under several configurations. The 2D map of the TOF deviation or d-spacing deviation, in terms of lattice shift/lattice strain, is reported. The change in TOF is dependent on the scanned location in the beam as well as on detector locations. The results are informative for experimental planning, data interpretation, and future instrument design.

36 MATERIALS SCIENCE↗

A Comparative Study on Computation of Cumulative Distribution Function in Predicting Time of Failure of Engineering Systems

Estimating accurate Time-of-Failure (ToF) of a system is key in making the decisions that impact operational safety and optimize cost. In this context, it is interesting to note that different approaches have been explored to tackle the problem of estimating ToF. The difference is in part characterized by different definitions of the hazard zones. The conventional definition for the cumulative distribution function (CDF) calculation is assumed to have well-defined hazard zones, that is, hazard zones defined as a function of the system state trajectory. An alternate method suggests the use of hazard zones defined as a function of the system state at time , instead of hazard zones defined as a function of system state up to and including time k (Acuna and Orchard 2018, 2017). This paper explores these differences and their impact on ToF estimation. Results for the conventional CDF definition indicated that, (i) the cumulative distribution function is always an increasing function of time, even when realizations of the degradation process are not monotonic, (ii) the sum of all probabilities is always 1 and does not need to be normalized, and (iii) all probabilities are positive and less than or equal to 1. Similar results are not observed for CDF calculation with hazard zones defined as a function only of the system state at time . Results for ToF estimation using Acuna's definition differ, suggesting that there is an underlying assumption of independence in the hazard zone definition. Therefore, we present an alternate definition of hazard zone which guarantees the properties of a well-defined CDF with a more straightforward ToF definition.

Hazard Zone↗

Development of picoseconds Time of Flight systems in Meson Test Beam Facility at Fermilab

The goal of the work is to develop time of flight (TOF) system with about 10 picosecond time resolution in real beam line when start and stop counters separated by some distance. We name the distance as 'base' for the TOF. This 'real' TOF setup is different from another one when start and stop counters located next to each other. The real TOF is sensitive to beam momentum spread, beam divergence, etc. Anyway some preliminary measurements are useful with close placement of start and stop counter. We name it 'close geometry'. The work started about 2 years ago at Fermilab Meson Test Beam Facility (MTBF). The devices tested in 'close geometry' were Microchannel Plate Photomultipliers (MCP PMT) with Cherenkov radiators. TOF counters based on Silicon Photomultipliers (SiPms) with Cherenkov radiators also in 'close geometry' were tested. We report here new results obtained with the counters in the MTBF at Fermilab, including beam line data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of a double Time-Of-Flight detector system for accurate velocity measurement in a storage ring using laser beams

The Isochronous Mass Spectrometry (IMS) is a powerful tool for mass measurements of exotic nuclei with half-lives as short as several tens of micro-seconds in storage rings. In order to improve the mass resolving power while preserving the acceptance of the storage ring, the IMS with two Time-Of-Flight (TOF) detectors has been implemented at the storage ring CSRe in Lanzhou, China. Additional velocity information beside the revolution time in the ring can be obtained for each of the stored ions by using the double TOF detector system. In this paper, we introduced a new method of using a 658 nm laser range finder and a short-pulsed ultra-violet laser to directly measure the distance and time delay difference between the two TOF detectors which were installed inside the 10 -11 mbar vacuum chambers. Here, the results showed that the distance between the two ultra-thin carbon foils of the two TOF detectors was ranging from 18032.5 mm to 18035.0 mm over a measurable area of 20x20 mm 2 .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗