Search NASA⌕ Search

SEARCH · Search NASA

Results for “Temperature Gradient”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Collisionless kinetic-fluid simulation of zonal flows in non-circular tokamaks

Fluid simulation of linear zonal flow damping is done with a closure model based on the collisionless gyrokinetics [Sugama et al., Phys. Plasmas 14, 022502 (2007)]. Simulation results of residual zonal flow for low radial wavenumbers are compared with theoretical formulas for circular and non-circular tokamaks. The effects of the elongation and the triangularity are shown to be properly treated in the closure model. Effects of initial parallel flows on zonal flow evolution are also clarified. An appropriate choice of the initial parallel flow gives a much higher residual level than the conventional result with no initial parallel flow. Besides, the zonal flow simulations are done with the E Multiplication-Sign B nonlinearity as initial sources, which is evaluated from linear gyrokinetic microinstabilities such as ion temperature gradient modes, trapped electron modes, and electron temperature gradient modes, in order to estimate efficiency of zonal flow generation by the source instabilities.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

How does negative triangularity mitigate ITG turbulence and transport?

Improved confinement in negative triangularity (NT) experiments is attributed to reduced fluxes driven by micro-turbulence. The physical mechanism of why thermal confinement improves in NT relative to PT is unknown. This study employs gyrokinetic flux tube simulations using the GENE code with local Miller equilibrium to elucidate the physical mechanisms behind the beneficial effects of NT flux surface shapes. The focus is on collisionless ion temperature gradient (ITG) driven turbulence with adiabatic electrons. The kinetic profiles are held fixed across a scan of triangularity values, thus enabling comparisons on a level playing field. The reduced linear growth rates for NT is shown to be due to a reduced eigenmode averaged magnetic drift frequency and a wider, stronger negative local magnetic shear region about the outboard mid-plane. The nonlinear heat flux is lower for NT than that for PT, due to reduced radial correlation length and increased correlation time (τ c ) of fluctuations. These, in turn, are due to a comparatively higher level of self-generated zero-frequency E × B zonal shearing rate ω E in NT as compared to PT. Though the linear zonal potential residual is lower for NT, the nonlinearly generated E × B zonal shearing rate is higher for NT than for PT. This outcome is linked to the distinctive features of the radial wavenumber spectra of the zonal potential and the zonal shearing rate. The dimensionless parameter ω E τ c is suggested as a figure of merit. This is higher for NT than for PT. Thus, the reduced heat diffusivity for NT is linked to increased ω E τ c . Self-generated temperature corrugations (i.e. zonal temperature gradients) are much weaker than the background mean temperature gradient. Nevertheless, temperature corrugations are more pronounced in NT than in PT.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Climate Response to Stratospheric Aerosol Geoengineering Can Be Tailored Using Multiple Injection Locations

By injecting different amounts of SO 2 at multiple different latitudes, the spatial pattern of aerosol optical depth (AOD) can be partially controlled. This leads to the ability to influence the climate response to geoengineering with stratospheric aerosols, providing the potential for design. In this work, we use simulations from the fully coupled whole-atmosphere chemistry climate model CESM1(WACCM) to demonstrate that by appropriately combining injection at just four different locations, 30°S, 15°S, 15°N, and 30°N, then three spatial degrees of freedom of AOD can be achieved: an approximately spatially uniform AOD distribution, the relative difference in AOD between Northern and Southern Hemispheres, and the relative AOD in high versus low latitudes. For forcing levels that yield 1–2°C cooling, the AOD and surface temperature response are sufficiently linear in this model so that the response to different combinations of injection at different latitudes can be estimated from single-latitude injection simulations; nonlinearities associated with both aerosol growth and changes to stratospheric circulation will be increasingly important at higher forcing levels. Optimized injection at multiple locations is predicted to improve compensation of CO 2 -forced climate change relative to a case using only equatorial aerosol injection (which overcools the tropics relative to high latitudes). The additional degrees of freedom can be used, for example, to balance the interhemispheric temperature gradient and the equator to pole temperature gradient in addition to the global mean temperature. Further research is needed to better quantify the impacts of these strategies on changes to long-term temperature, precipitation, and other climate parameters.

54 ENVIRONMENTAL SCIENCES↗

Proposed Drill Sites

Proposed drill sites for intermediate depth temperature gradient holes and/or deep resource confirmation wells. Temperature gradient contours based on shallow TG program and faults interpreted from seismic reflection survey are shown, as are two faults interpreted by seismic contractor Optim but not by Oski Energy, LLC.

15 GEOTHERMAL ENERGY↗

Phenotypic plasticity of fungal traits in response to moisture and temperature

Phenotypic plasticity of traits is commonly measured in plants to improve understanding of organismal and ecosystem responses to climate change but is far less studied for microbes. Specifically, decomposer fungi are thought to display high levels of phenotypic plasticity and their functions have important implications for ecosystem dynamics. Assessing the phenotypic plasticity of fungal traits may therefore be important for predicting fungal community response to climate change. Here, we assess the phenotypic plasticity of 15 fungal isolates (12 species) from a Southern California grassland. Fungi were incubated on litter at five moisture levels (ranging from 4–50% water holding capacity) and at five temperatures (ranging from 4–36 °C). After incubation, fungal biomass and activities of four extracellular enzymes (cellobiohydrolase (CBH), β -glucosidase (BG), β -xylosidase (BX), and N-acetyl- β - D -glucosaminidase (NAG)) were measured. We used response surface methodology to determine how fungal phenotypic plasticity differs across the moisture-temperature gradient. We hypothesized that fungal biomass and extracellular enzyme activities would vary with moisture and temperature and that the shape of the response surface would vary between fungal isolates. We further hypothesized that more closely related fungi would show more similar response surfaces across the moisture-temperature gradient. In support of our hypotheses, we found that plasticity differed between fungi along the temperature gradient for fungal biomass and for all the extracellular enzyme activities. Plasticity also differed between fungi along the moisture gradient for BG activity. These differences appear to be caused by variation mainly at the moisture and temperature extremes. We also found that more closely related fungi had more similar extracellular enzymes activities at the highest temperature. Altogether, this evidence suggests that with global warming, fungal biodiversity may become increasingly important as functional traits tend to diverge along phylogenetic lines at higher temperatures.

59 BASIC BIOLOGICAL SCIENCES↗

Thermal transport dynamics in the quasi-single helicity state

A dynamical model describing oscillations between multiple and single helicity configurations in the quasi-single helicity (QSH) state of the reversed field pinch [P. W. Terry and G. G. Whelan, Plasma Phys. Controlled Fusion 56, 094003 (2014)] is extended to include electron temperature profile dynamics. It is shown that QSH dynamics is linked to the electron temperature profile because the suppression of mode coupling between tearing modes proposed to underlie QSH also suppresses magnetic-fluctuation-induced thermal transport. Above the threshold of dominant-mode shear that marks the transition to QSH, the model produces temperature-gradient steepening in the strong shear region. Oscillations of the dominant and secondary mode amplitudes give rise to oscillations of the temperature gradient. The phasing and amplitude of temperature gradient oscillations relative to those of the dominant mode are in agreement with experiment. This provides further evidence that the model, while heuristic, captures key physical aspects of the QSH state.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Numerical Investigation of the characteristics of pressurized biomass-oxy-combustion

As a second generation of oxy-fuel combustion technologies, pressurized oxy-combustion has a potential to improve the process efficiency and economy. With the modern decarbonization needs, biomass combustion is considered to be nearly CO2 neutral, and thus co-firing biomass with coal in an oxy-combustion process can achieve a negative CO2 balance. The size of the biomass fuel particles is a key parameter in an entrained flow combustor because large biomass particles, exceeding some threshold size, may only partially be burnt due to the restrictions on the heat transport, thereby diminishing the combustion efficiency. While such a threshold particle size has been scrutinized at an atmospheric pressure, the present study extends the analysis to elevated pressures. Specifically, two scenarios were set up, for experimental-scale and full-scale pressurized oxy-combustors, with the threshold sizes of biomass particles appearing 0.5 mm and 5 mm, respectively, without temperature gradient in biomass particles. With temperature gradient, the parametric study included the particles in the range from 0.15 mm to 5 mm. It is shown that the thermal-thin model is applicable to spherical biomass particles not exceeding 0.15 mm. The impact of the heating rate on biomass particle devolatilization was also investigated and the biomass devolatilization could happen in less than 1 second; the same amount of heat energy could induce different volatile release rates.

Li, Lei↗

Modeling fuel assembly distortion in light water reactors using BISON

Individual fuel rods in a light water reactor fuel assembly (FA) often have different power profiles that result in a spatial temperature gradient in the FA. This temperature gradient causes some rods to elongate more than others which could in turn distort the entire FA. Such FA distortion has been known to cause operational difficulties with refueling and with the insertion of control rods [1]. Numerical modeling of FA distortion due to differential elongation of fuel rods requires: (i) modeling the thermal elongation as well as the creep and irradiation induced elongation of the fuel rods, and (ii) modeling the bending response of the FA due to the differential elongation of the fuel rods. Past studies on this topic have been focused on the mechanical deformation of the FA with simplistic modeling of fuel rod elongation. In this paper, a simulation approach is presented that directly couples 2D axisymmetric fuel performance models of the individual fuel rods in a FA with structural beam models of the fuel rods in a FA using the Bison code [2]. This allows all of the mechanisms internal to the fuel rod leading to cladding elongation to be accounted for in the FA distortion model. To demonstrate this capability, the bowing of a simplified and idealized 6x6 FA (Fig. 1a), modeled using beam elements, is analyzed under different spatially varying power profiles. For this study, the guide tubes are rigidly connected to the spacer grid. Also, the fuel rods are rigidly connected to the spacer grid in all directions except the vertical direction (Y) along which slipping can occur between the fuel rods and spacer grids, depending on the friction coefficient between them. Coupling the thermo-mechanical response of individual fuel rods to the global mechanical behavior of the FA can shed light on the mechanisms that cause distortion of the FA and potential solutions to address this issue.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Linear multispecies gyrokinetic flux tube benchmarks in shaped tokamak plasmas

Verification is the fundamental step that any turbulence simulation code has to be submitted in order to assess the proper implementation of the underlying equations. We have carried out a cross comparison of three flux tube gyrokinetic codes, GENE [F. Jenko et al., Phys. Plasmas 7, 1904 (2000)], GKW [A. G. Peeters et al., Comput. Phys. Commun. 180, 2650 (2009)], and GS2 [W. Dorland et al., Phys. Rev. Lett. 85, 5579 (2000)], focusing our attention on the effect of realistic geometries described by a series of MHD equilibria with increasing shaping complexity. To simplify the effort, the benchmark has been limited to the electrostatic collisionless linear behaviour of the system. A fully gyrokinetic model has been used to describe the dynamics of both ions and electrons. Several tests have been carried out looking at linear stability at ion and electron scales, where for the assumed profiles Ion Temperature Gradient (ITG)/Trapped Electron Modes and Electron Temperature Gradient modes are unstable. The capability of the codes to handle a non-zero ballooning angle has been successfully benchmarked in the ITG regime. Finally, the standard Rosenbluth-Hinton test has been successfully carried out looking at the effect of shaping on Zonal Flows (ZFs) and Geodesic Acoustic Modes (GAMs). Inter-code comparison as well as validation of simulation results against analytical estimates has been accomplished. All the performed tests confirm that plasma elongation strongly stabilizes plasma instabilities as well as leads to a strong increase in ZF residual and GAM damping.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The role of ETG modes in JET–ILW pedestals with varying levels of power and fuelling

Abstract We present the results of GENE gyrokinetic calculations based on a series of JET–ITER-like-wall (ILW) type I ELMy H-mode discharges operating with similar experimental inputs but at different levels of power and gas fuelling. We show that turbulence due to electron-temperature-gradient (ETGs) modes produces a significant amount of heat flux in four JET–ILW discharges, and, when combined with neoclassical simulations, is able to reproduce the experimental heat flux for the two low gas pulses. The simulations plausibly reproduce the high-gas heat fluxes as well, although power balance analysis is complicated by short ELM cycles. By independently varying the normalised temperature gradients ( ω T e ) and normalised density gradients ( ω n e ) around their experimental values, we demonstrate that it is the ratio of these two quantities η e = ω T e / ω n e that determines the location of the peak in the ETG growth rate and heat flux spectra. The heat flux increases rapidly as η e increases above the experimental point, suggesting that ETGs limit the temperature gradient in these pulses. When quantities are normalised using the minor radius, only increases in ω T e produce appreciable increases in the ETG growth rates, as well as the largest increases in turbulent heat flux which follow scalings similar to that of critical balance theory. However, when the heat flux is normalised to the electron gyro-Bohm heat flux using the temperature gradient scale length L T e , it follows a linear trend in correspondence with previous work by different authors.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

On the applicability of probabilistic analyses to assess the structural reliability of materials and components for solid-oxide fuel cells

The applicability of probabilistic analyses to assess the structural reliability of materials and components for solid-oxide fuel cells (SOFC) is investigated by measuring the failure rate of Ni-YSZ when subjected to a temperature gradient and comparing it with that predicted using the Ceramics Analysis and Reliability Evaluation of Structures (CARES) code. The use of a temperature gradient to induce stresses was chosen because temperature gradients resulting from gas flow patterns generate stresses during SOFC operation that are the likely to control the structural reliability of cell components The magnitude of the predicted failure rate was found to be comparable to that determined experimentally, which suggests that such probabilistic analyses are appropriate for predicting the structural reliability of materials and components for SOFCs. Considerations for performing more comprehensive studies are discussed.

Lara-Curzio, Edgar↗

The Effect of Bismuth on the Structural Perfection and the Luminescent Properties of Thin-Film Elastically Stressed Al{sub x}In{sub y}Ga{sub 1–x–y}Bi{sub z}Sb{sub 1–z}/GaSb Heterostructures

The effect of bismuth on the structural perfection and the luminescent properties of Al{sub x}In{sub y}Ga{sub 1–x–y}Bi{sub z}Sb{sub 1–z}/GaSb heterostructures has been studied. The optimal parameters of the process of zone recrystallization with temperature gradient at which epitaxial AlInGaBiSb layers have the minimum roughness and high structural perfection have been revealed: temperature gradient 1 ≤ G ≤ 30 K/cm, the liquid zone thickness 60 ≤ l ≤ 100 μm, the temperature range 773 K ≤ T ≤ 873 K, and bismuth concentration 0.3–0.4 mol fraction.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

West Flank Coso FORGE: 3D Temperature Model

x,y,z data of the 3D temperature model for the West Flank Coso FORGE site. Model grid spacing is 250m. The temperature model for the Coso geothermal field used over 100 geothermal production sized wells and intermediate-depth temperature holes. At the near surface of this model, two boundary temperatures were assumed: (1) areas with surface manifestations, including fumaroles along the northeast striking normal faults and northwest striking dextral faults with the hydrothermal field, a temperature of ~104 deg C was applied to datum at +1066 meters above sea level elevation, and (2) a near-surface temperature at about 10 meters depth, of 20 deg C was applied below the diurnal and annual conductive temperature perturbations. These assumptions were based on heat flow studies conducted at the CVF and for the Mojave Desert. On the edges of the hydrothermal system, a 73 deg C/km temperature gradient contour was established using conductive gradient data from shallow and intermediate-depth temperature holes. This contour was continued to all elevation datums between the 20 deg C surface and -1520 meters below mean sea level. Because the West Flank is outside of the geothermal field footprint, during Phase 1, the three wells inside the FORGE site were incorporated into the preexisting temperature model. To ensure a complete model was built based on all the available data sets, measured bottom-hole temperature gradients in certain wells were downward extrapolated to the next deepest elevation datum (or a maximum of about 25% of the well depth where conductive gradients are evident in the lower portions of the wells). After assuring that the margins of the geothermal field were going to be adequately modelled, the data was contoured using the Kriging method algorithm. Although the extrapolated temperatures and boundary conditions are not rigorous, the calculated temperatures are anticipated to be within ~6 deg C (20 deg F), or one contour interval, of the observed data within the Coso geothermal field. Based on a lack of temperature data west of 74-2TCH, the edges of this model still seem to have an effect on West Flank modeled temperatures.

15 GEOTHERMAL ENERGY↗

SU-E-J-273: Skin Temperature Recovery Rate as a Potential Predictor for Radiation-Induced Skin Reactions

Purpose: To assess the potential of dynamic infrared imaging to evaluate early skin reactions during radiation therapy in cancer patients. Methods: Thermal images were captured by our home-built system consisting of two flash lamps and an infrared (IR) camera. The surface temperature of the skin was first raised by ∼ 6 °C from ∼1 ms short flashes; the camera then captured a series of IR images for 10 seconds. For each image series, a basal temperature was recorded for 0.5 seconds before flash was triggered. The temperature gradients (ε) were calculated between a reference point (immediately after the flash) and at a time point of 2sec, 4sec and 9sec after that. A 1.0 cm region of interest (ROI) on the skin was drawn; the mean and standard deviations of the ROIs were calculated. The standard ε values for normal human skins were evaluated by imaging 3 healthy subjects with different skin colors. All of them were imaged on 3 separate days for consistency checks. Results: The temperature gradient, which is the temperature recovery rate, depends on the thermal properties of underlying tissue, i.e. thermal conductivity. The average ε for three volunteers averaged over 3 measurements were 0.64±0.1, 0.72±0.2 and 0.80±0.3 at 2sec, 4sec and 9sec respectively. The standard deviations were within 1.5%–3.2%. One of the volunteers had a prior small skin burn on the left wrist and the ε values for the burned site were around 9% (at 4sec) and 13% (at 9sec) lower than that from the nearby normal skin. Conclusion: The temperature gradients from the healthy subjects were reproducible within 1.5%–3.2 % and that from a burned skin showed a significant difference (9%–13%) from the normal skin. We have an IRB approved protocol to image head and neck patients scheduled for radiation therapy.

60 APPLIED LIFE SCIENCES↗

Reducing turbulent transport in toroidal configurations via shaping

Recent progress in reducing turbulent transport in stellarators and tokamaks by 3D shaping using a stellarator optimization code in conjunction with a gyrokinetic code is presented. The original applications of the method focused on ion temperature gradient transport in a quasi-axisymmetric stellarator design. Here, an examination both of other turbulence channels and other starting configurations is initiated. It is found that the designs evolved for transport from ion temperature gradient turbulence also display reduced transport from other transport channels whose modes are also stabilized by improved curvature, such as electron temperature gradient and ballooning modes. The optimizer is also applied to evolving from a tokamak, finding appreciable turbulence reduction for these devices as well. From these studies, improved understanding is obtained of why the deformations found by the optimizer are beneficial, and these deformations are related to earlier theoretical work in both stellarators and tokamaks.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Inward particle transport at high collisionality in the Experimental Advanced Superconducting Tokamak

We have made the first drift wave study of particle transport in the Experimental Advanced Superconducting Tokamak (Wan et al., Nucl. Fusion 49, 104011 (2009)). The results reveal that collisions make the particle flux more inward in the high collisionality regime. This can be traced back to effects that are quadratic in the collision frequency. The particle pinch is due to electron trapping which is not very efficient in the high collisionality regime so the approach to equilibrium is slow. We have included also the electron temperature gradient (ETG) mode to give the right electron temperature gradient, since the Trapped Electron Mode (TE mode) is weak in this regime. However, at the ETG mode number ions are Boltzmann distributed so the ETG mode does not give particle transport.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Thermal Response of a Packed Bed Thermal Energy Storage System upon Saturated Steam Injection Using Distributed Temperature Sensing

The effectiveness of a thermal energy storage (TES) system is typically characterized with the help of thermal stratification or temperature gradients along the direction of heat injection, which is typically the flow direction of heat transfer fluid. The steepness of temperature gradients are a direct indicator of the effectiveness or efficiency of the heat storage or dispatch process. The temperature gradient evolution along the packed bed of ceramic particles upon saturated steam injection is presented in this work. Distributed temperature sensing based on optical frequency domain reflectometry was deployed in a packed bed of ceramic particles to capture the thermal front evolution in the axial direction. The physical processes accompanying steam injection in packed beds are complex due to phase change, transitioning two-phase flow, and changes in condensate accumulation. Therefore, the variation of thermal response of the TES system for various steam injection flow rates was experimentally studied using a high-resolution distributed temperature sensing system in a chemically inert alumina particle-packed bed. Distinct zones of different heat transfer modes were observed during the steam injection experiments. A distinct conduction zone, evident from diffuse thermal fronts, was observed at low flow rates, and these thermal gradients became sharper as the flow rate increased. The diffuse thermal fronts in the heat storage media suggest a low exergy efficiency of the TES system, as energy losses started initiating before a significant fraction of the bed was saturated with steam.

25 ENERGY STORAGE↗