Search NASA⌕ Search

SEARCH · Search NASA

Results for “Time resolved imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Transient vibration and product formation of photoexcited CS 2 measured by time-resolved x-ray scattering

Here, we have observed details of the internal motion and dissociation channels in photoexcited carbon disulfide (CS 2 ) using time-resolved x-ray scattering (TRXS). Photoexcitation of gas-phase CS 2 with a 200 nm laser pulse launches oscillatory bending and stretching motion, leading to dissociation of atomic sulfur in under a picosecond. During the first 300 fs following excitation, we observe significant changes in the vibrational frequency as well as some dissociation of the C–S bond, leading to atomic sulfur in the both 1 D and 3 P states. Beyond 1400 fs, the dissociation is consistent with primarily 3 P atomic sulfur dissociation. This channel-resolved measurement of the dissociation time is based on our analysis of the time-windowed dissociation radial velocity distribution, which is measured using the temporal Fourier transform of the TRXS data aided by a Hough transform that extracts the slopes of linear features in an image. The relative strength of the two dissociation channels reflects both their branching ratio and differences in the spread of their dissociation times. Measuring the time-resolved dissociation radial velocity distribution aids the resolution of discrepancies between models for dissociation proposed by prior photoelectron spectroscopy work.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Contribution of advanced fluorescence nano microscopy towards revealing mitotic chromosome structure

The organization of chromatin into higherorder structures and its condensation process represent one of the key challenges in structural biology. This is important for elucidating several disease states. To address this long-standing problem, development of advanced imaging methods has played an essential role in providing understanding into mitotic chromosome structure and compaction. Amongst these are two fast evolving fluorescence imaging technologies, specifically fluorescence lifetime imaging (FLIM) and superresolution microscopy (SRM). FLIM in particular has been lacking in the application of chromosome research while SRM has been successfully applied although not widely. Furthermore, both these techniques are capable of providing fluorescence imaging with nanometer information. SRM or "nanoscopy" is capable of generating images of DNA with less than 50 nm resolution while FLIM when coupled with energy transfer may provide less than 20 nm information. Here, we discuss the advantages and limitations of both methods followed by their contribution to mitotic chromosome studies. Furthermore, we highlight the future prospects of how advancements in new technologies can contribute in the field of chromosome science.

59 BASIC BIOLOGICAL SCIENCES↗

The SuperCam Instrument Suite on the Mars 2020 Rover: Science Objectives and Mast-Unit Description

On the NASA 2020 rover mission to Jezero crater, the remote determination of the texture, mineralogy and chemistry of rocks is essential to quickly and thoroughly characterize an area and to optimize the selection of samples for return to Earth. As part of the Perseverance payload, SuperCam is a suite of five techniques that provide critical and complementary observations via Laser-Induced Breakdown Spectroscopy (LIBS), Time-Resolved Raman and Luminescence (TRR/L), visible and near-infrared spectroscopy (VISIR), high-resolution color imaging (RMI), and acoustic recording (MIC). SuperCam operates at remote distances, primarily 2–7 m, while providing data at sub-mm to mm scales. We report on SuperCam’s science objectives in the context of the Mars 2020 mission goals and ways the different techniques can address these questions. The instrument is made up of three separate subsystems: the Mast Unit is designed and built in France; the Body Unit is provided by the United States; the calibration target holder is contributed by Spain, and the targets themselves by the entire science team. This publication focuses on the design, development, and tests of the Mast Unit; companion papers describe the other units. The goal of this work is to provide an understanding of the technical choices made, the constraints that were imposed, and ultimately the validated performance of the flight model as it leaves Earth, and it will serve as the foundation for Mars operations and future processing of the data.

47 OTHER INSTRUMENTATION↗

Effect of a collapsing gas bubble on the shock-to-detonation transition in liquid nitromethane

We studied the shock-induced collapse of butane gas bubbles in the homogeneous explosive nitromethane (NM) to investigate the effects of hot spot formation on the detonation process. A butane bubble was injected into a sample of NM, and a shock wave from a flat plate impactor compressed the bubble, creating a localized hot spot. We measured shock and detonation wave speeds with optical velocimetry, and we used a high-speed camera to image the shock propagation and bubble collapse processes. A multiband optical fiber pyrometer measured the time-resolved thermal radiance, and we used the results and emissivity values extracted from spectral fits to estimate temperatures. We measured the characteristics of the shock-to-detonation transition in NM with and without a bubble. All experiments were performed at shock pressures near 8 GPa, where neat NM can detonate. A single bubble in this system was shown to sensitize NM, leading to a reduced run-to-detonation time. We used hydrodynamic modeling to predict shock wave propagation, the extent of chemical reaction, and subsequent temperature rise from the collapsing bubble. We used a temperature-dependent Arrhenius burn model for simulations, and it yielded much better results than reactive burn models that depend only on pressure and density.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Single-shot imaging with randomized structured illumination at a free electron laser

Stroboscopic nanoscale imaging with free electron laser light is revolutionizing our understanding of fast dynamics in heterogeneous systems. The short wavelength of X-ray and extreme ultraviolet radiation makes it possible to achieve nanoscale resolution, while resonance with atomic transitions gives access to electronic and magnetic degrees of freedom. Here, we report on our implementation of a recently developed imaging method, randomized probe imaging, at a free electron laser. The advantage of randomized probe imaging over existing methods is its compatibility with extended and strongly scattering samples. Our implementation delivers robust single-shot reconstructions at up to a full-pitch resolution of 400 nm over a field of view with a 40 µm diameter. We also demonstrate single-shot imaging of magnetic domain structures using circular dichroism at resonance, paving the way to future time-resolved studies of magnetic dynamics, shock physics, and the dynamics of collective electronic phases.

47 OTHER INSTRUMENTATION↗

Bragg edge imaging (BEI) of B12W and M8N socket sections of the Arecibo telescope

From neutron user principal investigator: We kindly request the public release of three neutron imaging datasets through ONCat. All datasets were collected from two forensic specimens, B12W and M8N, sectioned from zinc-filled steel-wire sockets recovered from the collapsed Arecibo Telescope. The dataset titled “Neutron radiographs of B12W and M8N socket sections of the Arecibo telescope” contains normalized two-dimensional (2D) neutron radiographs of the specimens, showing the geometry and spatial distribution of the steel wires embedded within the zinc matrix, as well as internal features such as voids and cracks. The dataset titled “Neutron computed tomography of B12W and M8N socket sections of the Arecibo telescope” contains normalized 2D neutron projection images acquired over a range of specimen rotation angles for one selected region of each specimen. These projection images were used to reconstruct three-dimensional (3D) tomographic volumes that reveal the embedded-wire geometry and internal defects. The dataset titled “Bragg edge imaging (BEI) of B12W and M8N socket sections of the Arecibo telescope” contains six time-of-flight (TOF) neutron imaging datasets, three from each specimen, acquired at regions of interest selected based on the radiographs. The spatially resolved 2D TOF images show the zinc matrix and embedded steel wires, and the wavelength-dependent neutron transmission data were used to characterize crystallographic texture within the zinc. All components and their condition are in the public domain as they are the property of the National Science Foundation (NSF). The neutron imaging data, part geometries, and detailed forensic information have been widely published in the Arecibo Telescope Collapse Forensic Report by Thornton Tomasetti Engineers and others (NASA report and NASEM report).

Bilheux, Hassina↗

Path-Integrated X-Ray Images for Multi-Surface Digital Image Correlation (PI-DIC)

X-ray imaging offers unique possibilities for Digital Image Correlation (DIC), opening the door for full-field deformation measurements of a test article in complex environments where optical DIC suffers severe biases or is impossible. While X-ray DIC has been performed in the past with standard DIC codes designed for optical images, the path-integrated nature of X-ray images places constraints on the experimental setup, predominantly that only a single surface of interest moves/deforms. These requirements are difficult to realize for many practical situations and limit the amount of information that can be garnered in a single test. Other X-ray based diagnostics such as Digital Volume Correlation (DVC) and Projection DVC (P-DVC) overcome these obstacles, but DVC is limited to quasi-static tests, and both DVC and P-DVC necessitate high-resolution computed tomography (CT) scan(s) and often require a potentially invasive pattern throughout the volume of the specimen. Here this work presents a novel approach to measure time-resolved displacements and strains on multiple surfaces from a single series of 2D, path-integrated (PI) X-ray images, called PI-DIC. The principle of optical flow or conservation of intensity—the foundation of DIC—was reframed for path-integrated images, for an exemplar setup comprised of two plates moving and deforming independently. Synthetic images were generated for rigid translations, rigid rotations, and uniform stretches, where each plate underwent a unique motion/deformation. Experimental specimens were fabricated (either an aluminum plate with tantalum features or a plastic plate with steel features) and the two specimens were independently translated. PI-DIC was successfully demonstrated with the synthetic images and validated with the experimental images. Prescribed displacements were recovered for each plate from the single set of path-integrated, deformed images. Errors were approximately 0.02 px for the synthetic images with 1.5% image noise, and 0.05 px for the experimental images. These results provide the foundation for PI-DIC to measure motion and deformation of multiple, independent surfaces with subpixel accuracy from a single series of path-integrated X-ray images.

47 OTHER INSTRUMENTATION↗

Degradation Dynamics of Perovskite Solar Cells Under Fixed Reverse-Current Injection

Previous studies of reverse-bias stability in perovskite solar cells have focused primarily on voltage-controlled tests. Here we instead investigate perovskite solar cell degradation under well-defined, constant reverse-current stress. We show that the choice of hole-transport layer dictates the dominant degradation pathway: cells using thick poly(triphenylamine) (PTAA) layers can tolerate high reverse bias but quickly undergo catastrophic breakdown under fixed reverse current near their one-sun maximum power-point. In contrast, cells modified with phosphonic-acid interface layer MeO-2PACz, with poorer indium-doped tin oxide (ITO) coverage compared to PTAA, exhibit gradual and recoverable degradation under certain stress and recovery conditions. For MeO-2PACz devices, degradation increases with both current magnitude and duration. Importantly, when normalized by injected charge (current times duration), lower currents applied over longer times cause more degradation than higher currents over shorter periods. Here, combining electrical measurements with spatially resolved photoluminescence imaging, our observations support an ion- and charge-mediated interfacial electrochemical degradation mode.

Degradation↗

Slide Test FY 2019 Report

At Los Alamos, the Slide Test was developed in 2019 to investigate whether the mass of a main charge of explosive sliding on a gritty surface, in the absence of impact, is sufficient to heat grit to ignition temperatures in PBX 9501. This is a practical test to address frictional ignition during assembly/disassembly operations at the Pantex Plant. Twenty-seven Slide Tests were performed in total, testing PBX 9501 at various slide velocities, grit diameters, grit patterns, and charge masses. Time-resolved velocimetry of the slide event (from PDV) and spot area of the explosive charge (obtained from image analysis) is reported. High-speed videography is used to diagnose explosive reaction. Eighteen of these tests were performed with a charge mass of 30 lbs at velocities ≤ 4 m s-1 and grit diameters between 75 and 1000 µm. Nine Slide Tests were performed with a 15 lb charge mass at similar parameters. No ignition was observed in any of the tests. These data provide evidence that the mass of a main charge, caused to slide on a surface at the low velocities achievable during routine handling, is insufficient stimulus to heat grit to ignition temperatures. These findings are relevant to risk assessment for explosive handling operations and provide evidence that PBX 9501 is safe within the constraints that were tested. However, because ignitions were not observed in any of the tests, we cannot determine which variables (mass or velocity) dominate the explosive response and to what extent. The absence of observed ignition also precludes the determination of a safety margin. To identify this safety margin, further research would be necessary to define the velocity and/or mass threshold at which ignition occurs.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Advancements in Heat Transfer and Fluid Mechanics (Fundamentals and Applications)

Thermo-fluid science is a foundational discipline for numerous mechanical systems, particularly in energy production and building equipment, where thermal and mechanical energy transfer play critical roles. Advancements in heat transfer and fluid mechanics have significantly enhanced these systems, driving progress in associated market sectors. For instance, evaporator and condenser coils are essential for optimizing vapor compression cycles in building equipment. Heat pumps used for space and water heating constitute a major share of building systems, with microchannel heat exchanger technology at the forefront of these innovations. It is worth mentioning that advancements in heat transfer and fluid mechanics significantly alleviate the challenge of designing energy-efficient building equipment. The development of research techniques has contributed significantly to the advancement of science; for example, in the experimental field, non-intrusive measurement techniques such as Particle Image Velocimetry (PIV) are now capable of resolving flow behavior in a 3D format for different length and time scales.

42 ENGINEERING↗

Degradation Dynamics of Perovskite Solar Cells Under Fixed Reverse Current Injection

Previous studies of reverse-bias stability in perovskite solar cells have focused primarily on voltage controlled reverse-bias tests. Here we instead present an investigation of perovskite solar cell degradation under well-defined, constant reverse-current stress. We show that the choice of hole-transport layer dictates the dominant degradation pathway: cells using thick poly(triphenylamine) (PTAA) layers with better indium-doped tin oxide (ITO) coverage can tolerate high reverse bias but quickly undergo catastrophic breakdown under fixed reverse current near their one-sun maximum power-point. In contrast, cells modified with the phosphonic-acid interface layer MeO-2PACz, with poorer ITO coverage compared to PTAA, exhibit soft, gradual, and largely recoverable degradation, regardless of the shading conditions. For MeO-2PACz devices, degradation increases with both current magnitude and duration. Importantly, when normalized by injected charge (current times duration), lower currents applied over longer times cause more severe degradation than higher currents over shorter periods. Combining electrical measurements with spatially resolved photoluminescence imaging, we argue against shunt formation and instead support an ion- and charge-mediated interfacial electrochemical degradation mode.

Applied Physics (physics.app-ph)↗

Time-domain modelling and thermometry of the CH 4 v 1 Q-branch using hybrid femtosecond/picosecond coherent anti-Stokes Raman scattering

Here, we present time-domain measurements and modelling of the CH 4 v 1 vibrational Q-branch, as well as simultaneous temperature acquisition from the CH 4 and N 2 vibrational Q-branches using broadband hybrid femtosecond/picosecond coherent anti-Stokes Raman scattering (fs/ps CARS). Accurate measurements with fs/ps CARS require knowledge of the time-domain response of the probed molecule at different temperatures and pressures. In this work, a fs/ps CARS model was developed for theCH 4 v 1 Q-branch and validated using time-resolved probe delay scans at pressures between 70 and 600 Torr and temperatures between 295 and 1000 K. A simplified modified exponential energy gap model was used to determine the linewidths of the Raman transitions within the Q-branch. Total Q-branch linewidths for the entire explored parameter space were also determined from the probe delay scans. This enabled quantitative measurements of CH 4 with fs/ps CARS as well as the temperature through the hot bands of the CH 4 v 1 Q-branch. With a broadband fs laser pulse in a two-beam phase matching scheme, the N 2 Q-branch and CH 4 v 1 Q-branch were simultaneously measured in a heated cell, and the temperatures from each molecule's spectra was evaluated. Here, the fitted temperatures corresponded well with differences ranging from 4 to 17%. It was also shown that exchanging 90% of CH 4 for N 2 or Ar at 295 K and 500 Torr did not significantly impact the normalized time-domain signal prior to a 100 picosecond probe delay. Spatially resolved one-dimensional (1-D) thermometry using the CH 4 Q-branch was also demonstrated with an imaged spatial resolution of 40 µm. With the developed model, 1-D quantitative measurements of CH 4 concentration and temperature can be measured with time resolution of tens of picoseconds.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Tracking Dendritic Growth in Hydrogen-Based Hematite Reduction via Computer Vision

The reduction of hematite to metallic iron using hydrogen (H2) as a reducing agent presents a promising pathway for decarbonizing steel production. In this study, we employ a combination of in situ confocal scanning laser microscopy (CSLM) and advanced computer vision techniques to quantitatively analyze dendritic growth of ferrite during H2-based reduction of iron oxide at high temperatures. A workflow integrating Watershed Image Segmentation (WIS) and Lucas-Kanade Optical Flow (LKOF) is developed to extract both global and local kinetic information from time-resolved micrograph sequences. H2 reduction experiments conducted at 1400 degrees C and 1500 degrees C demonstrate a clear correlation between temperature and reduction rate, as evidenced by accuracy of fitted Johnson-Mehl-Avrami-Kolmogorov (JMAK) parameters. Optical flow analysis further elucidates the anisotropic and branched nature of dendritic growth, providing spatially resolved velocity fields that correlate well with global transformation kinetics. The proposed methodology demonstrates strong agreement with experimental measurements and literature values, offering a robust framework for automated image-based analysis to study kinetics through microstructural evolution in the reduction of iron ore, and likely other reaction-diffusion phenomena.

08 HYDROGEN↗

Planar shock-induced bubble collapse and jetting in water captured via X-ray phase contrast imaging

Shock wave–bubble interactions in water manifest rich dynamics driven by a combination of strong pressure and density mismatches. They have a wide variety of applications, including the injection of pharmaceuticals, and through scaling, enable the exploration of various aspects of high-energy-density systems such as inertial confinement fusion. In this work, the interaction between a micrometric nitrogen bubble and a planar shock wave, characterized by a Mach number of M = 1.24 and a peak pressure of p max = 0.57 , is experimentally recorded using ultra-high-speed x-ray phase contrast imaging. Highly resolved radiographs provide access to all phase discontinuities along the beam path, offering quantities such as the time-varying bubble size, the speed of a jet produced during the bubble collapse, and the time evolution of the shock wave front, which are critical benchmark data for numerical scheme validation. This study addresses the lack of well-characterized, repeatable, and high spatiotemporal resolution experiments at negative Atwood numbers by providing shock–bubble visualization and corresponding numerical simulation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

macroMS: Image-Guided Analysis of Random Objects by Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry

Mass spectrometry imaging is well-suited to characterizing sample surfaces for their chemical content in a spatially resolved manner. However, when the surface contains small objects with significant empty spaces between them, more efficient approaches to sample acquisition are possible. Image-guided mass spectrometry (MS) enables high-throughput analysis of a diverse range of sample types, such as microbial colonies, liquid microdroplets, and others, by recognizing and analyzing selected location targets in an image. Here, we describe an imaging protocol and macroMS, an online software suite that can be used to enhance MS measurements of macroscopic samples that are imaged by a camera or a flatbed scanner. Furthermore, the web-based tool enables users to find and filter targets from the optical images, correct optical distortion issues for improved spatial location of selected targets, input the custom geometry files into an MS device to acquire spectra at the selected locations, and finally, perform limited data analysis and use visualization tools to aid locating samples containing compounds of interest. Using the macroMS suite, an enzyme mutant library of Saccharomyces cerevisiae and nL droplet arrays of Escherichia coli and Pseudomonas fluorescens have been assayed at a rate of ~2 s/sample.

47 OTHER INSTRUMENTATION↗

Characterization of a Low-Temperature Plasma (LTP) Ambient Ionization Source Using Temporally Resolved Monochromatic Imaging Spectrometry

The low-temperature plasma (LTP) probe is a common plasma-based source used for ambient desorption–ionization mass spectrometry (MS). While the LTP probe has been characterized in detail with MS, relatively few studies have used optical spectroscopy. In this paper, two-dimensional (2D) imaging at selected wavelengths is used to visualize important species in the LTP plasma jet. First, 2D steady-state images of the LTP plume for N 2 + (391.2 nm), He I (706.5 nm), and N 2 (337.1 nm) emissions were recorded under selected plasma conditions. Second, time-resolved 2D emission maps of radiative species in the LTP plasma jet were recorded through the use of a 200 ns detection gate and varying gate delays with respect to the LTP trigger pulse. Emission from He I, N 2 + , and N 2 in the plasma jet region was found to show a transient behavior (often referred to as plasma bullets) lasting only a few microseconds. The N 2 + and He I maps were highly correlated in spatial and temporal structure. Further, emission from N 2 showed two maxima in time, one before and one after the maximum emission for N 2 + and He I, due to an initial electronic excitation wave and ion–electron recombination, respectively. Third, the interaction of the LTP probe with a sample substrate and an electrically grounded metallic needle was studied. Emission from a fluorophore on the sample substrate showed an initial photon-induced excitation from plasma-generated photons followed by electronic excitation by other plasma species. The presence of a grounded needle near the plasma jet significantly extended the plasma jet lifetime and also generated a long-lived corona discharge on the needle. The effect of LTP operating parameters on emission spectra was correlated with mass-spectral results including reagent-ion signals. Lastly, five movies provide a side-by-side comparison of the temporal behavior of emitting species and insights into the interactions of the emission clouds with a sample surface as well as an external needle. Temporally and spatially resolved imaging provided insights into important processes in the LTP plasma jet, which will help improve analyte ion sampling in LTP–MS.

Chan, George C. -Y.↗

The next-generation particle x-ray temporal diagnostic for simultaneous time-resolved measurements of nuclear-burn and x-ray emission histories in support of basic-science and inertial confinement fusion experiments at OMEGA

The next-generation Particle X-ray Temporal Diagnostic (PXTD) has been implemented for simultaneous measurements of x-ray, charged particle, and neutron emission histories from a wide range of inertial confinement fusion and high energy density plasma experiments, demonstrating excellent timing accuracy and greatly improved experimental flexibility. The key changes to the previously fielded system are a redesigned set of thin foil filters in front of the scintillators and individual neutral density filters for each region of the detector. The fully implemented PXTD system can provide unique information about the evolution of ion and electron temperatures in multi-ion and kinetic-physics experiments, proton radiography experiments, and DT experiments executed at the OMEGA facility. The system has 35 ps time resolution and negligible relative timing uncertainty between measured emission history signals. The first use of the upgraded four-channel PXTD system during a set of D 3 He-filled silica-glass implosions on OMEGA captured electron temperatures with a minimum uncertainty of 0.5 keV and resolved both the relative timings and widths of neutron, proton, and x-ray peaks within a single recorded image.

Evans, T. E. [Massachusetts Inst. of Technology (M↗

Selective Dynamical Imaging of Interferometric Data

Recent developments in very long baseline interferometry (VLBI) have made it possible for the Event Horizon Telescope (EHT) to resolve the innermost accretion flows of the largest supermassive black holes on the sky. The sparse nature of the EHT’s (u, v)-coverage presents a challenge when attempting to resolve highly time-variable sources. We demonstrate that the changing (u, v)-coverage of the EHT can contain regions of time over the course of a single observation that facilitate dynamical imaging. These optimal time regions typically have projected baseline distributions that are approximately angularly isotropic and radially homogeneous. We derive a metric of coverage quality based on baseline isotropy and density that is capable of ranking array configurations by their ability to produce accurate dynamical reconstructions. We compare this metric to existing metrics in the literature and investigate their utility by performing dynamical reconstructions on synthetic data from simulated EHT observations of sources with simple orbital variability. We then use these results to make recommendations for imaging the 2017 EHT Sgr A* data set.

79 ASTRONOMY AND ASTROPHYSICS↗