Search NASA⌕ Search

SEARCH · Search NASA

Results for “Variance analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

A 492 GHz cooled Schottky receiver for radio-astronomy

We developed a 492 GHz cooled GaAs Schottky receiver driven by a solid state local oscillator with a DSB noise temperature of 550 K measured at the telescope. The receiver-bandwidth is approx. equal to 1.0 GHz. Quasi-optical mirrors focus the sky and local oscillator radiation into the mixer. Stability analysis via the Allan variance method shows that the total system including a 1 GHz bandwidth acousto-optical spectrometer built in Cologne allows integration times up to 100 sec per half switching cycle. We successfully used the receiver at the KOSMA 3 m telescope on Gornergrat (3150m) located in the central Swiss Alps near Zermatt during January-February 1992 for observations of the 492 GHz, (CI) (3)P1 to (3)P0 fine structure line in several galactic sources. These observations confirm that Gornergrat is an excellent winter submillimeter site in accordance with previous predictions based on the atmospheric opacity from KOSMA 345 GHz measurements.

Hernichel, J.↗

Vergence-dependent adaptation of the vestibulo-ocular reflex

The gain of the vestibulo-ocular reflex (VOR) normally depends on the distance between the subject and the visual target, but it remains uncertain whether vergence angle can be linked to changes in VOR gain through a process of context-dependent adaptation. In this study, we examined this question with an adaptation paradigm that modified the normal relationship between vergence angle and retinal image motion. Subjects were rotated sinusoidally while they viewed an optokinetic (OKN) stimulus through either diverging or converging prisms. In three subjects the diverging prisms were worn while the OKN stimulus moved out of phase with the head, and the converging prisms were worn when the OKN stimulus moved in-phase with the head. The relationship between the vergence angle and OKN stimulus was reversed in the fourth subject. After 2 h of training, the VOR gain at the two vergence angles changed significantly in all of the subjects, evidenced by the two different VOR gains that could be immediately accessed by switching between the diverged and converged conditions. The results demonstrate that subjects can learn to use vergence angle as the contextual cue that retrieves adaptive changes in the angular VOR.

NASA Discipline Developmental Biology↗

Flexor bias of joint position in humans during spaceflight

The ability to estimate ankle and elbow joint position was tested before, during, and after a 17-day spaceflight. Subjects estimated targeted joint angles during isovelocity (IsoV) joint movements with agonist muscle groups either active or relaxed. These movements included elbow extension (EE) and elbow flexion (EF), and plantarflexion (PF) and dorsiflexion (DF) of the ankle. Subjects also estimated these joint positions while moving the dynamometer at their chosen (variable) velocity (VarV) during EE and PF. For IsoV tests, no differences were observed between active and passive movements for either the ankle or elbow. Compared with those of pre-flight test days, estimates of targeted elbow joint angles were approximately 5 degrees to 15 degrees more flexed in-flight, and returned toward the pre-flight values during recovery. The spaceflight effects for the ankle were inconsistent and less prevalent than those for the elbow. The VarV PF test condition for the 120 degrees target angle at the ankle exhibited approximately 5 degrees to 7 degrees more DF target angle estimates in-flight compared with those pre- or post-flight. In contrast, during IsoV PF there was a tendency for ankle estimates to be approximately 2 degrees to 3 degrees more PF after 2-3 days exposure to spaceflight. These data indicate that during spaceflight the perception of elbow extension is greater than actuality, and are consistent with the interpretation that microgravity induced a flexor bias in the estimation of the actual elbow joint position. Moreover, these effects in joint proprioception during spaceflight were observed in individual isolated single-joint movements during tasks in which vestibular function in maintaining posture were minimal.

STS-78 Shuttle Project↗

Effects of the oral contraceptive pill cycle on physiological responses to hypoxic exercise

To test whether the oral contraceptive pill cycle affects endocrine and metabolic responses to hypoxic (fraction of inspired oxygen = 13%, P(IO2): 95 mmHg; H) versus normoxic (P(IO2):153 mmHg; N) exercise, we examined eight women (28 +/- 1.2 yr) during the third (PILL) and placebo (PLA) weeks of their monthly oral contraceptive pill cycle. Cardiopulmonary, metabolic, and neuroendocrine measurements were taken before, during, and after three 5-min consecutive workloads at 30%, 45%, and 60% of normoxic V(O2peak) in H and N trials. Heart rate response to exercise was greater in H versus N, but was not different between PILL and PLA. Lactate levels were significantly greater during exercise, and both lactate and glucose levels were significantly greater for 30 min after exercise in H versus N (p < 0.0001). When expressed relative to baseline, lactate levels were lower in PILL versus PLA, but glucose was greater in PILL versus PLA (p < 0.001). Cortisol levels were also significantly greater in PILL versus PLA (p < 0.001). Norepinephrine levels were significantly increased during exercise (p < 0.0001) and in H versus N (p < 0.0001). However, epinephrine levels were not different over time or with trial. Thus, the presence of circulating estradiol and progesterone during the PILL phase reduces glucose and lactate responses to hypoxic exercise.

Non-NASA Center↗

Bimanual cross-talk during reaching movements is primarily related to response selection, not the specification of motor parameters

Simultaneous reaching movements made with the two hands can show a considerable increase in reaction time (RT) when they differ in terms of direction or extent, compared to when the movements involve the same direction and extent. This cost has been attributed to cross-talk in the specification of the motor parameters for the two hands. However, a recent study [Diedrichsen, Hazeltine, Kennerley, & Ivry, (2001). Psychological Science, 12, 493-498] indicates that when reaching movements are cued by the onset of the target endpoint, no compatibility effects are observed. To determine why directly cued movements are immune from interference, we varied the stimulus onset asynchrony for the two movements and used different combinations of directly cued and symbolically cued movements. In two experiments, compatibility effects were only observed when both movements were symbolically cued. No difference was found between compatible and incompatible movements when both movements were directly cued or when one was directly cued and the other was symbolically cued. These results indicate that interference is not related to the specification of movement parameters but instead emerges from processes associated with response selection. Moreover, the data suggest that cross-talk, when present, primarily shortens the RT of the second movement on compatible trials rather than lengthening this RT on incompatible trials.

Randomized Controlled Trial↗

Effect of dietary sodium on fluid/electrolyte regulation during bed rest

BACKGROUND: A negative fluid balance during bed rest (BR) is accompanied by decreased plasma volume (PV) which contributes to cardiovascular deconditioning. HYPOTHESIS: We hypothesized that increasing dietary sodium while controlling fluid intake would increase plasma osmolality (POSM), stimulate fluid conserving hormones, and reduce fluid/electrolyte (F/E) losses during BR; conversely, decreasing dietary sodium would decrease POSM, suppress fluid conserving hormones, and increase F/E losses. METHODS: We controlled fluid intake (30 ml x kg(-1) x d(-1)) in 17 men who consumed either a 4.0 +/- 0.06 g x d(-1) (174 mmol x d(-1)) (CONT; n = 6), 1.0 +/- 0.02 g x d(-1) (43 mmol x d(-1)) (LS; n = 6), or 10.0 +/- 0.04 g x d(-1) (430 mmol x d(-1)) (HS; n = 5) sodium diet before, during, and after 21 d of 6 degrees head-down BR. PV, total body water, urine volume and osmolality, POSM, and F/E controlling hormone concentrations were measured. RESULTS: In HS subjects, plasma renin activity (-92%), plasma/urinary aldosterone (-59%; -64%), and PV (-15.0%; 6.0 ml x kg(-1); p < 0.05) decreased while plasma atrial natriuretic peptide (+34%) and urine antidiuretic hormone (+24%) increased during BR (p < 0.05) compared with CONT. In LS, plasma renin activity (+166%), plasma aldosterone (+167%), plasma antidiuretic hormone (+19%), and urinary aldosterone (+335%) increased with no change in PV compared with CONT (p < 0.05). Total body water did not change in any of the subjects. CONCLUSIONS: Contrary to our hypothesis, increasing dietary sodium while controlling fluid intake during BR resulted in a greater loss of PV compared with the CONT subjects. Reducing dietary sodium while controlling fluid intake did not alter the PV response during BR compared with CONT subjects.

Clinical Trial↗

Balance in a rotating artificial gravity environment

When subjects stand at the center of a fully enclosed room that is rotating at constant velocity, their natural postural sway generates Coriolis forces that destabilize their center of mass and head. We quantitatively assessed how exposure to constant velocity rotation at 10 rpm affected postural control. Twelve subjects stood in a heel-to-toe stance in the rotating room. Each test session involved three phases: (1) pre-rotation, (2) per-rotation, and (3) post-rotation. In each phase, subjects were tested in both eyes open and eyes closed conditions. Four measures were used to characterize center of mass movement and head movement: mean sway amplitude, total power, mean power frequency, and frequency of maximum power. Each measure was computed for anterior-posterior and medial-lateral sway. Both anterior-posterior and medial-lateral head and center of mass sway during rotation had significantly greater mean sway amplitude and total power compared with pre- and post-rotation values. Mean power frequency and frequency of maximum power were little affected. Eyes open conditions were significantly more stable in all test phases than eyes-closed, but vision did not completely suppress the effects of rotation. The greatest effect of rotation was in the eyes-closed condition with mean sway amplitude and total power increasing more than twofold. Inverted pendulum sway was maintained in all phases of both test conditions. No aftereffects of rotation were present after the four 25-s exposures each subject received. We expect that with longer exposure periods and with active generation of body sway subjects would both adapt to rotation and exhibit post-rotary aftereffects.

NASA Discipline Neuroscience↗

A quasi-static method for determining the characteristics of a motion capture camera system in a "split-volume" configuration

The purpose of this study was to determine the accuracy, repeatability and resolution of a six-camera Motion Analysis system in a vertical split-volume configuration using a unique quasi-static methodology. The position of a reflective marker was recorded while it was moved quasi-statically over a range of 2.54 mm (0.100 inches) via a linearly-translating table. The table was placed at five different heights to cover both sub-volumes and the overlapping region. Data analysis showed that accuracy, repeatability and resolution values were consistent across all regions of the split-volume, including the overlapping section.

NASA Center JSC↗

Physiological changes, sleep, and morning mood in an isolated environment

BACKGROUND: Previous isolation studies have shown increased 24-h urine volumes and body weight gains in subjects. This project examined those and other physiological variables in relationship to sleep motor activity, subjective sleep quality, mood, and complaints during confinement. METHODS: Six male and two female subjects lived for 7 d in the National Space Development Agency of Japan's isolation chamber, which simulates the interior of the Japanese Experiment Module. Each 24-h period included 6 h of sleep, 3 meals, and 20 min of exercise. Each morning, subjects completed Sleep Sensation and Complaint Index questionnaires. Catecholamine and creatinine excretion, urine volume, and body weight were measured on the 2 d before and 2 d after confinement, and sleep motor activity was measured during confinement. RESULTS: Confinement produced no significant change in body weight, urine volume, or questionnaire results. In contrast, epinephrine, norepinephrine, and sleep motor activity exhibited significant differences during confinement (p < 0.05). Higher nocturnal norepinephrine excretion correlated with higher sleep motor activity. CONCLUSION: The 24-h epinephrine values were slightly higher than normal throughout the experiment, but lower than for subjects working under time-stress. High sympathetic activity (as indicated by norepinephrine) may have interfered with sleep.

NASA Discipline Space Human Factors↗

Do vestibular otolith organs participate in human orthostatic blood pressure control?

We hypothesized that vestibular otolith organ stimulation contributes to human orthostatic responses. Twelve subjects underwent three 60 degrees upright tilts: (1) with the neck flexed from 0 degrees to 30 degrees relative to the body during 60 degrees tilt, such that the head moved from horizontal to 90 degrees above horizontal (0 to 1 Gz otolith stimulation); (2) with the head and body aligned, such that they tilted together to 60 degrees (0 to 0.87 Gz otolith stimulation); and (3) with the neck flexed 30 degrees relative to the body during supine conditions, and the neck then extended to -30 degrees during 60 degrees body tilting, such that the head remained at 30 degrees above horizontal throughout body tilting (constant 0.5 Gz otolith stimulation). All three tilt procedures increased thoracic impedance, sympathetic nerve activity (N = 8 of 12), arterial pressure, and heart rate relative to supine conditions (all P < 0.04). Within the first 20 s of tilt, arterial pressure increased most obviously in the 0 to 1 Gz otolith condition. Thoracic impedance tended to increase more in otolith-constant conditions, but no dependent variable differed significantly between tilt conditions, and no significant time x tilt interactions emerged. Otolith inputs may contribute to early transient adjustments to orthostasis. However, lack of significant main effects of tilt condition and time x tilt interactions suggests that potential otolith effects on the variables we studied are relatively subtle and ephemeral, or that other mechanisms compensate for a lack of change in otolith input with orthostasis.

Non-NASA Center↗

Context-specific adaptation of saccade gain

Previous studies established that vestibular reflexes can have two adapted states (e.g., gain) simultaneously, and that a context cue (e.g., vertical eye position) can switch between the two states. The present study examined this phenomenon of context-specific adaptationfor horizontal saccades, using a variety of contexts. Our overall goal was to assess the efficacy of different context cues in switching between adapted states. A standard double-step paradigm was used to adapt saccade gain. In each experiment, we asked for a simultaneous gain decrease in one context and gain increase in another context, and then determined if a change in the context would invoke switching between the adapted states. Horizontal eye position worked well as a context cue: saccades with the eyes deviated to the right could be made to have higher gains while saccades with the eyes deviated to the left could be made to have lower gains. Vertical eye position was less effective. This suggests that the more closely related a context cue is to the response being adapted, the more effective it is. Roll tilt of the head, and upright versus supine orientations, were somewhat effective in context switching; these paradigms contain orientation of gravity with respect to the head as part of the context.

NASA Discipline Neuroscience↗

Automated fault-management in a simulated spaceflight micro-world

BACKGROUND: As human spaceflight missions extend in duration and distance from Earth, a self-sufficient crew will bear far greater onboard responsibility and authority for mission success. This will increase the need for automated fault management (FM). Human factors issues in the use of such systems include maintenance of cognitive skill, situational awareness (SA), trust in automation, and workload. This study examine the human performance consequences of operator use of intelligent FM support in interaction with an autonomous, space-related, atmospheric control system. METHODS: An expert system representing a model-base reasoning agent supported operators at a low level of automation (LOA) by a computerized fault finding guide, at a medium LOA by an automated diagnosis and recovery advisory, and at a high LOA by automate diagnosis and recovery implementation, subject to operator approval or veto. Ten percent of the experimental trials involved complete failure of FM support. RESULTS: Benefits of automation were reflected in more accurate diagnoses, shorter fault identification time, and reduced subjective operator workload. Unexpectedly, fault identification times deteriorated more at the medium than at the high LOA during automation failure. Analyses of information sampling behavior showed that offloading operators from recovery implementation during reliable automation enabled operators at high LOA to engage in fault assessment activities CONCLUSIONS: The potential threat to SA imposed by high-level automation, in which decision advisories are automatically generated, need not inevitably be counteracted by choosing a lower LOA. Instead, freeing operator cognitive resources by automatic implementation of recover plans at a higher LOA can promote better fault comprehension, so long as the automation interface is designed to support efficient information sampling.

NASA Discipline Space Human Factors↗

Context-specific adaptation of the gain of the oculomotor response to lateral translation using roll and pitch head tilts as contexts

Previous studies established that vestibular and oculomotor behaviors can have two adapted states (e.g., gain) simultaneously, and that a context cue (e.g., vertical eye position) can switch between the two states. The present study examined this phenomenon of context-specific adaptation for the oculomotor response to interaural translation (which we term "linear vestibulo-ocular reflex" or LVOR even though it may have extravestibular components). Subjects sat upright on a linear sled and were translated at 0.7 Hz and 0.3 gpeak acceleration while a visual-vestibular mismatch paradigm was used to adaptively increase (x2) or decrease (x0) the gain of the LVOR. In each experimental session, gain increase was asked for in one context, and gain decrease in another context. Testing in darkness with steps and sines before and after adaptation, in each context, assessed the extent to which the context itself could recall the gain state that was imposed in that context during adaptation. Two different contexts were used: head pitch (26 degrees forward and backward) and head roll (26 degrees or 45 degrees, right and left). Head roll tilt worked well as a context cue: with the head rolled to the right the LVOR could be made to have a higher gain than with the head rolled to the left. Head pitch tilt was less effective as a context cue. This suggests that the more closely related a context cue is to the response being adapted, the more effective it is.

Non-NASA Center↗

Lower-body negative-pressure exercise and bed-rest-mediated orthostatic intolerance

PURPOSE: Supine, moderate exercise is ineffective in maintaining orthostatic tolerance after bed rest (BR). Our purpose was to test the hypothesis that adding an orthostatic stress during exercise would maintain orthostatic function after BR. METHODS: Seven healthy men completed duplicate 15-d 6 degrees head-down tilt BR using a crossover design. During one BR, subjects did not exercise (CON). During another BR, subjects exercised for 40 min.d(-1) on a supine treadmill against 50-60 mm Hg LBNP (EX). Exercise training consisted of an interval exercise protocol of 2- to 3-min intervals alternating between 41 and 65% (.)VO(2max). Before and after BR, an LBNP tolerance test was performed in which the LBNP chamber was decompressed in 10-mm Hg stages every 3 min until presyncope. RESULTS: LBNP tolerance, as assessed by the cumulative stress index (CSI) decreased after BR in both the CON (830 +/- 144, pre-BR vs 524 +/- 56 mm Hg.min, post-BR) and the EX (949 +/- 118 pre-BR vs 560 +/- 44 mm Hg.min, post-BR) conditions. However, subtolerance (0 to -50 mm Hg LBNP) heart rates were lower and systolic blood pressures were better maintained after BR in the EX condition compared with CON. CONCLUSION: Moderate exercise performed against LBNP simulating an upright 1-g environment failed to protect orthostatic tolerance after 15 d of BR.

NASA Center JSC↗

Speech motor control and acute mountain sickness

BACKGROUND: An objective method that accurately quantifies the severity of Acute Mountain Sickness (AMS) symptoms is needed to enable more reliable evaluation of altitude acclimatization and testing of potentially beneficial interventions. HYPOTHESIS: Changes in human articulation, as quantified by timed variations in acoustic waveforms of specific spoken words (voice onset time; VOT), are correlated with the severity of AMS. METHODS: Fifteen volunteers were exposed to a simulated altitude of 4300 m (446 mm Hg) in a hypobaric chamber for 48 h. Speech motor control was determined from digitally recorded and analyzed timing patterns of 30 different monosyllabic words characterized as voiced and unvoiced, and as labial, alveolar, or velar. The Environmental Symptoms Questionnaire (ESQ) was used to assess AMS. RESULTS: Significant AMS symptoms occurred after 4 h, peaked at 16 h, and returned toward baseline after 48 h. Labial VOTs were shorter after 4 and 39 h of exposure; velar VOTs were altered only after 4 h; and there were no changes in alveolar VOTs. The duration of vowel sounds was increased after 4 h of exposure and returned to normal thereafter. Only 1 of 15 subjects did not increase vowel time after 4 h of exposure. The 39-h labial (p = 0.009) and velar (p = 0.037) voiced-unvoiced timed separations consonants and the symptoms of AMS were significantly correlated. CONCLUSIONS: Two objective measures of speech production were affected by exposure to 4300 m altitude and correlated with AMS severity. Alterations in speech production may represent an objective measure of AMS and central vulnerability to hypoxia.

NASA Discipline Space Human Factors↗

Controlled breaks as a fatigue countermeasure on the flight deck

BACKGROUND: A major challenge for flight crews is the need to maintain vigilance during long, highly automated nighttime flights. No system currently exists to assist in managing alertness, and countermeasure options are limited. Surveys reveal many pilots use breaks as an in-flight countermeasure, but there have been no controlled studies of their effectiveness. HYPOTHESIS: We hypothesized that brief, regular breaks could improve alertness and performance during an overnight flight. METHOD: A 6-h, uneventful, nighttime flight in a Boeing 747-400 flight simulator was flown by fourteen two-man crews. The 14 subjects in the treatment group received 5 short breaks spaced hourly during cruise; the 14 subjects in the control group received 1 break in the middle of cruise. Continuous EEG/EOG, subjective sleepiness, and psychomotor vigilance performance data were collected. RESULTS: During the latter part of the night, the treatment group showed significant reductions for 15 min post-break in slow eye movements, theta-band activity, and unintended sleep episodes compared with the control group. The treatment group reported significantly greater subjective alertness for up to 25 min post-break, with strongest effects near the time of the circadian trough. There was no evidence of objective vigilance performance improvement at 15-25 min post-break, with expected performance deterioration occurring due to elevated sleep drive and circadian time. CONCLUSIONS: The physiological and subjective data indicate the breaks reduced nighttime sleepiness for at least 15 min post-break and may have masked sleepiness for up to 25 min, suggesting the potential usefulness of short-duration breaks as an in-flight fatigue countermeasure.

Non-NASA Center↗

Perceived orientation in physical and virtual environments: changes in perceived orientation as a function of idiothetic information available

Two experiments examined perceived spatial orientation in a small environment as a function of experiencing that environment under three conditions: real-world, desktop-display (DD), and head-mounted display (HMD). Across the three conditions, participants acquired two targets located on a perimeter surrounding them, and attempted to remember the relative locations of the targets. Subsequently, participants were tested on how accurately and consistently they could point in the remembered direction of a previously seen target. Results showed that participants were significantly more consistent in the real-world and HMD conditions than in the DD condition. Further, it is shown that the advantages observed in the HMD and real-world conditions were not simply due to nonspatial response strategies. These results suggest that the additional idiothetic information afforded in the real-world and HMD conditions is useful for orientation purposes in our presented task domain. Our results are relevant to interface design issues concerning tasks that require spatial search, navigation, and visualization.

NASA Center ARC↗

Differential effects of catecholamines on in vitro growth of pathogenic bacteria

Supplementation of minimal medium inoculated with bacterial cultures with norepinephrine, epinephrine, dopamine, or isoproterenol resulted in marked increases in growth compared to controls. Norepinephrine and dopamine had the greatest enhancing effects on growth of cultures of Pseudomonas aeruginosa and Klebsiella pneumoniae, while epinephrine and isoproterenol also enhanced growth to a lesser extent. The growth of Escherichia coli in the presence of norepinephrine was greater than growth in the presence of the three other neurochemicals used in the study. Growth of Staphylococcus aureus was also enhanced in the presence of norepinephrine, but not to the same degree as was the growth of gram negative bacteria. Addition of culture supernatants from E. coli cultures that had been grown in the presence of norepinephrine was able to enhance the growth of K. pneumoniae. Addition of the culture supernatant fluid culture from E. coli cultures that had been grown in the presence of norepinephrine did not enhance growth of P. aeruginosa or S. aureus. Culture supernatant fluids from bacteria other than E. coli grown in the presence of norepinephrine were not able to enhance the growth of any bacteria tested. The results suggest that catecholamines can enhance growth of pathogenic bacteria, which may contribute to development of pathogenesis; however, there is no uniform effect of catecholamines on bacterial growth.

Non-NASA Center↗