Search NASA⌕ Search

SEARCH · Search NASA

Results for “Verification study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Uncertainty Propagation from Experiment Measurements to Modeling Approaches: A Case for SMR Steam Entrainment Testing

To license new and advanced reactor designs, regulators must be convinced that their unique safety cases—relative to existing large scale reactors—have been adequately addressed by the designed reactor protection systems. In water cooled small modular reactors (SMRs), droplet entrainment in steam flow has significant implications on the progression of accident scenarios due to its compact design features, which requires representative test data applicable to SMR designs. Computer code, modeling and simulation (M&S) tools and models require adequate verification, assessment, and qualification. This includes M&S results validation against scaled empirical data within allowable uncertainty bands to gain regulatory approvals during the various stages of reactor system design, demonstration, and commercialization. However, measurement uncertainty within the empirical datasets and test data applicability ranges requires careful consideration of M&S inputs (i.e., boundary conditions, and initial conditions), and verification and validation efforts. This study focuses on uncertainty quantification in designing scaled test facilities for SMR applications with appropriate measurements and a standard data-reduction method to estimate thermal hydraulics characteristics parameters that incorporate physics phenomena of interest. In addition, this study supports the evaluation model development and assessment process using M&S that interfaces with advanced computing tools and digital twin capabilities. This will allow synchronization between experiment and modeling approaches for droplet entrainment testing and analysis, improving diagnostics, prognostics, and decision-making to accelerate regulatory approval.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Convergent conductivity corrections to the Casimir force via exponential basis functions

A closed-form finite conductivity correction factor for the ideal Casimir force is proposed, based on exponential basis functions. Our method can facilitate experimental verifications of theories in the study of the Casimir force. A theoretical analysis is given to explain why our method is accurate at both large and small separation gaps. Numerical computations have been performed to confirm that our method is accurate in various experimental configurations. Our approach is widely applicable to various Casimir force interactions between metals and dielectrics. Our study can be extended to the study of the repulsive Casimir force as well.

36 MATERIALS SCIENCE↗

FY12 Quarter 3 Computing Utilization Report – LANL

DSW continues to dominate the capacity workload, with a focus in Q3 on common model baselining runs in preparation for the Annual Assessment Review (AAR) of the weapon systems. There remains unmet demand for higher fidelity simulations, and for increased throughput of simulations. Common model baselining activities would benefit from doubling the resolution of the models and running twice as many simulations. Capacity systems were also utilized during the quarter to prepare for upcoming Level 2 milestones. Other notable DSW activities include validation of new physics models and safety studies. The safety team used the capacity resources extensively for projects involving 3D computer simulations for the Furrow series of experiments at DARHT (a Level 2 milestone), fragment impact, surety theme, PANTEX assessments, and the 120-day study. With the more than tripling of classified capacity computing resources with the addition of the Luna system and the safety team's imminent access to the Cielo system, demand has been met for current needs. The safety team has performed successful scaling studies on Luna up to 16K PE size-jobs with linear scaling, running the large 3D simulations required for the analysis of Furrow. They will be investigating scaling studies on the Cielo system with the Lustre file system in Q4. Overall average capacity utilization was impacted by negative effects of the LANL Voluntary Separation Program (VSP) at the beginning of Q3, in which programmatic staffing was reduced by 6%, with further losses due to management backfills and attrition, resulting in about 10% fewer users. All classified systems were impacted in April by a planned 2 day red network outage. ASC capacity workload continues to focus on code development, regression testing, and verification and validation (V&V) studies. Significant capacity cycles were used in preparation for a JOWOG in May and several upcoming L2 milestones due in Q4. A network transition has been underway on the unclassified networks to increase access of all ASC users to the unclassified systems through the Yellow Turquoise Integration (YeTI) project. This will help to alleviate the longstanding shortage of resources for ASC unclassified code development and regression testing, and also make a broader palette of machines available to unclassified ASC users, including PSAAP Alliance users. The Moonlight system will be the first capacity resource to be made available through the YETI project, and will make available a significant increase in cycles, as well as GPGPU accelerator technology. The Turing and Lobo machines will be decommissioned in the next quarter. ASC projects running on Cielo as part of the CCC-3 include turbulence, hydrodynamics, burn, asteroids, polycrystals, capability and runtime performance improvements, and materials including carbon and silicone.

43 PARTICLE ACCELERATORS↗

EXAMINING THE ROLE AND RESEARCH CHALLENGES OF SOCIAL MEDIA AS A TOOL FOR NONPROLIFERATION AND ARMS CONTROL TREATY VERIFICATION

Traditional arms control treaty verification activities typically involve a combination of technical measurements via physical and chemical sensors, state declarations, political agreements, and on-site inspections involving international subject matter experts. However, the ubiquity of the internet, and the electronic sharing of data that it enables, has made available a wealth of open source information with the potential to benefit verification efforts. Open source information is already being used by organizations such as the International Atomic Energy Agency to support the verification of state-declared information, prepare inspectors for in-field activities, and to maintain situational awareness . The recent explosion in social media use has opened new doors to exploring the attitudes, moods, and activities around a given topic. Social media platforms, such as Twitter, Facebook, and YouTube, offer an opportunity for individuals, as well as institutions, to participate in a global conversation at minimal cost. Social media data can also provide a more data-rich environment, with text data being augmented with images, videos, and location data. The research described in this paper investigates the utility of applying social media signatures as potential arms control and nonproliferation treaty verification tools and technologies, as determined through a series of case studies. The treaty relevant events that these case studies touch upon include detection of undeclared facilities or activities, determination of unknown events recorded by the International Monitoring System (IMS), and the global media response to the occurrence of an Indian missile launch. The case studies examine how social media can be used to fill an information gap and provide additional confidence to a verification activity. The case studies represent, either directly or through a proxy, instances where social media information may be available that could potentially augment the evaluation of an event. The goal of this paper is to instigate a discussion within the verification community as to where and how social media can be effectively utilized to complement and enhance traditional treaty verification efforts. In addition, this paper seeks to identify areas of future research and development necessary to adapt social media analytic tools and techniques, and to form the seed for social media analytics to aid and inform arms control and nonproliferation policymakers and analysts. While social media analysis (as well as open source analysis as a whole) will not ever be able to replace traditional arms control verification measures, they do supply unique signatures that can augment existing analysis.

nonproliferation, arms control, social media↗

Sci-Sat AM: Radiation Dosimetry and Practical Therapy Solutions - 04: On 3D Fabrication of Phantoms and Experimental Verification of Patient Dose Computation Algorithms

Purpose: Transport based dose calculation algorithm Acuros XB (AXB) has been shown to accurately account for heterogeneities mostly through comparisons with Monte Carlo simulations. This study aims at providing additional experimental verification for AXB for flattened and unflattened clinical energies in low density phantoms of the same material. Materials and Methods: Polystyrene slabs were created using a bench-top 3D printer. Six slabs were printed at varying densities from 0.23 g/cm{sup 3} to 0.68 g/cm{sup 3}, corresponding to different density humanoid tissues. The slabs were used to form different single and multilayer geometries. Dose was calculated with AXB 11.0.31 for 6MV, 15MV flattened and 6FFF (flattening filter free) energies for field sizes of 2×2 cm{sup 2} and 5×5 cm{sup 2}. The phantoms containing radiochromic EBT3 films were irradiated. Absolute dose profiles and 2D gamma analyses were performed for 96 dose planes. Results: For all single slab, multislab configurations and energies, absolute dose differences between the AXB calculation and film measurements remained <3% for both fields, with slightly poor disagreement in penumbra. The gamma index at 2% / 2mm averaged 98% in all combinations of fields, phantoms and photon energies. Conclusions: The transport based dose algorithm AXB is in good agreement with the experimental measurements for small field sizes using 6MV, 6FFF and 15MV beams adjacent to low density heterogeneous media. This work provides sufficient experimental ground to support the use of AXB for heterogeneous dose calculation purposes.

60 APPLIED LIFE SCIENCES↗

Long-term Prediction of Emissivity of Structural materials for High Temperature Reactor Systems

The purpose of this research was to extend the recent short-term studies of emissivity of reactor materials performed independently at the University of Missouri and University of Wisconsin to tests aimed at longerterm predictions of emissivity. The University of Missouri measured hemispherical emissivity, which provides an integrated measurement, while the University of Wisconsin measured spectral emissivity (2 to 10 μm wavelength) from which the integrated quantity can be obtained. Hemispherical emissivity is needed for MELCOR, RELAP and FLUENT type heat transfer code calculations, while spectral emissivity is needed for a detailed Monte Carlo Transport theory computation of heat transfer and fundamental modeling verification. The objectives of the study were: Objective 1: Defining materials for long-term emissivity in cross-cutting reactor applications - procurement, preparation, and analyses of materials. Objective 2: High temperature materials testing in various environments and post-test surface analysis Objective 3: Independent hemispherical and spectral emissivity testing. Objective 4: Development of models to gain a predictive capability for long-term emissivity and application and validation in current RCCS research programs. The research has been performed at two universities over a four-year term with the participation of students, scientific staff, and faculty. The report describes progress in realizing the objectives, and the accomplishments at the two universities. There was considerable progress with respect to Objectives 1-3. The model development was redirected towards modeling of interrelationships between the spectra and hemispherical emissivities and uncertainty analysis of total hemispherical emissivity measurements.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Enhancing the physical modeling capability of open-source MFIX-DEM software for handling particle size polydispersity: Implementation and validation

Multiphase flows are ubiquitous in many industrial processes. The inherent coupling of different phases poses many unique challenges in predicting and effectively controlling these processes. Hence, computational modeling and simulation offers a viable approach to overcome these challenges. Here in this study, we present recent development efforts for enhancing the physical modeling capabilities of an open-source computational modeling tool for real life industrial multiphase processes by enabling particle-size polydispersity and demonstrating with an associated validation study. The proposed implementation was performed in MFIX open-source framework due to its unique feature of tightly integrated computational fluid dynamics and discrete element method solvers for simulating coupled continuum fluid and granular flows. We have implemented the polydispersity feature in a minimally invasive way and provided means to allow easy specification of an arbitrary particle size distribution function, which also enables the user to easily handle an arbitrary number of solid phases, each possessing a distinct arbitrary particle-size distribution. To establish the credibility of improvements, we have carried out a preliminary verification and validation (V&V) study for the polydispersity feature by employing a hopper bin discharge problem, which is frequently encountered in industrial applications. Specifically, two types of micro-glass beads with distinct size distributions are used to fill the hopper in two possible packing arrangements, i.e., well-mixed and layered configurations, with varying mass (particle number) ratios. The experimentally obtained discharge dynamics (e.g., normalized discharge mass fraction for one of the phases versus the overall discharge mass fraction) for different systems is found to be in excellent agreement with the corresponding simulation results.

42 ENGINEERING↗

Capturing the variable reactivity of goethites in surface complexation modeling by correlating model parameters with specific surface area

The development of predictive tools capable of simulating adsorption behavior on goethite (α-FeOOH) surfaces has evolved over the past several decades. Recent research has focused on capturing the variation of surface reactivity and adsorption behavior for different preparations of synthetic goethites. Here in this research, an approach to estimate modeling parameters based on the specific surface area (SSA) of goethites was established and combined with a Charge Distribution – Multi-site Complexation (CD-MUSIC) surface complexation model. It was assumed that differences in crystal face contributions (CFC), inner-Helmholtz capacitances (C 1 ), and protonation constants of surface oxygens (pK a ’s) among different preparations of goethite contribute to the variation of surface reactivity. Thus, correlations of these modeling parameters with the SSA of a range of goethites were identified by comprehensively combining microscopic, macroscopic, and modeling data reported in literature along with adsorption data collected from macroscopic experiments conducted as part of this study. A CD-MUSIC model shown to be capable of accurately predicting adsorption for several metal ions and oxyanion selenite on a 62.9 m 2 /g SSA goethite served as the basis for the development of the adsorption modeling approach described in this paper. The predictive capability of the newly developed modeling approach was verified by comparing predictions of protons, SeO 3 2- , and Cd 2+ adsorption with experimental data from goethites with SSAs ranging between 21.3 and 105 m 2 /g; in total, 40 adsorption data sets from 13 different goethites were used for model verification. The results from this study indicate that the variation of surface reactivity of goethites can be successfully simulated by changing CFC, C 1 , and pK 2,singly (i.e. second protonation constant of singly-coordinated oxygens on the goethite surface) based on the SSA, which implies that self-consistent adsorption parameters can be applied to predict adsorption behavior over a range of goethite preparations.

58 GEOSCIENCES↗

An Investigation into Solution Verification for CFD-DEM

This report presents the study of the convergence behavior of the computational fluid dynamicsdiscrete element method (CFD-DEM) method, specifically National Energy Technology Laboratory’s (NETL) open source MFiX code (MFiX-DEM) with a diffusion based particle-tocontinuum filtering scheme. In particular, this study focused on determining if the numerical method had a solution in the high-resolution limit where the grid size is smaller than the particle size. To address this uncertainty, fixed particle beds of two primary configurations were studied: i) fictitious beds where the particles are seeded with a random particle generator, and ii) instantaneous snapshots from a transient simulation of an experimentally relevant problem. Both problems considered a uniform inlet boundary and a pressure outflow. The CFD grid was refined from a few particle diameters down to 1/6 th of a particle diameter. The pressure drop between two vertical elevations, averaged across the bed cross-section was considered as the system response quantity of interest. A least-squares regression method was used to extrapolate the grid-dependent results to an approximate “grid-free” solution in the limit of infinite resolution. The results show that the diffusion based scheme does yield a converging solution. However, the convergence is more complicated than encountered in simpler, single-phase flow problems showing strong oscillations and, at times, oscillations superimposed on top of globally non-monotonic behavior. The challenging convergence behavior highlights the importance of using at least four grid resolutions in solution verification problems so that (over-determined) regression-based extrapolation methods may be applied to approximate the grid-free solution. The grid-free solution is very important in solution verification and VVUQ exercise in general as the difference between it and the reference solution largely determines the numerical uncertainty. By testing different randomized particle configurations of the same general problem (for the fictitious case) or different instances of freezing a transient simulation, the numerical uncertainties appeared to be on the same order of magnitude as ensemble or time averaging uncertainties. By testing different drag laws, almost all cases studied show that model form uncertainty in this one, very important closure relation was larger than the numerical uncertainty, at least with a reasonable CFD grid, roughly five particle diameters. In this study, the diffusion width (filtering length scale) was mostly set at a constant of six particle diameters. A few exploratory tests were performed to show that similar convergence behavior was observed for diffusion widths greater than approximately two particle diameters. However, this subject was not investigated in great detail because determining an appropriate filter size is really a validation question which must be determined by comparison to experimental or highly accurate numerical data. Future studies are being considered targeting solution verification of transient simulations as well as validation of the filter size with direct numerical simulation data.

97 MATHEMATICS AND COMPUTING↗

SU-E-T-65: Characterization of a 2D Array for QA and Pretreatment Plan Verification

Purpose: The OCTAVIUS detector729 is a 2D array of 729 air vented cubic plane parallel ion chambers used for pretreatment verification and QA. In this study we investigated dosimetric characteristics of this system for clinical photon beam dosimetry. Methods: Detector performance evaluation included determination of the location of the effective point of measurement (EPM), sensitivity, linearity, and reproducibility of detector response, as well as output factor, dose rate, and source to surface distance (SSD) dependence. Finally, assessment of wedge modulated fields was carried out. All the evaluations were performed five times for low and high photon energies. For reference measurements, a 0.6 cc ionization chamber was used. Data analysis and comparison of the OCTAVIUS detector with reference ion chamber data was performed using the VeriSoft patient plan verification software. Results: The reproducibility and stability of the measurements are excellent, the detector showed same signal with a maximum deviation of less than 0.5% in short and long term. Results of sensitivity test showed same signal with a maximum deviation of approximately 0.1%. As the detector 729 response is linear with dose and dose rate, it can be used for the measurement at regions of high dose gradient effectively. The detector agrees with the ionization chamber measurement to within 1% for SSD range of 75 to 125 cm. Also, its measured wedge modulated profiles matched very well with ion chamber dose profiles acquired in a water tank. Conclusions: As the response of the detector 729 is linear with dose and dose rate, it can be used for the measurements in the areas of dose gradients effectively. Based on the measurements and comparisons performed, this system is a reliable and accurate dosimeter for QA and pretreatment plan verification in radiotherapy.

60 APPLIED LIFE SCIENCES↗

Verification of Gamma Knife extend system based fractionated treatment planning using EBT2 film

Purpose: This paper presents EBT2 film verification of fractionated treatment planning with the Gamma Knife (GK) extend system, a relocatable frame system for multiple-fraction or serial multiple-session radiosurgery.Methods: A human head shaped phantom simulated the verification process for fractionated Gamma Knife treatment. Phantom preparation for Extend Frame based treatment planning involved creating a dental impression, fitting the phantom to the frame system, and acquiring a stereotactic computed tomography (CT) scan. A CT scan (Siemens, Emotion 6) of the phantom was obtained with following parameters: Tube voltage—110 kV, tube current—280 mA, pixel size—0.5 × 0.5 and 1 mm slice thickness. A treatment plan with two 8 mm collimator shots and three sectors blocking in each shot was made. Dose prescription of 4 Gy at 100% was delivered for the first fraction out of the two fractions planned. Gafchromic EBT2 film (ISP Wayne, NJ) was used as 2D verification dosimeter in this process. Films were cut and placed inside the film insert of the phantom for treatment dose delivery. Meanwhile a set of films from the same batch were exposed from 0 to 12 Gy doses for calibration purposes. An EPSON (Expression 10000 XL) scanner was used for scanning the exposed films in transparency mode. Scanned films were analyzed with inhouse written MATLAB codes.Results: Gamma index analysis of film measurement in comparison with TPS calculated dose resulted in high pass rates >90% for tolerance criteria of 1%/1 mm. The isodose overlay and linear dose profiles of film measured and computed dose distribution on sagittal and coronal plane were in close agreement.Conclusions: Through this study, the authors propose treatment verification QA method for Extend frame based fractionated Gamma Knife radiosurgery using EBT2 film.

61 RADIATION PROTECTION AND DOSIMETRY↗

A Preliminary Study of In-House Monte Carlo Simulations: An Integrated Monte Carlo Verification System

Purpose: To develop an infrastructure for the integrated Monte Carlo verification system (MCVS) to verify the accuracy of conventional dose calculations, which often fail to accurately predict dose distributions, mainly due to inhomogeneities in the patient's anatomy, for example, in lung and bone. Methods and Materials: The MCVS consists of the graphical user interface (GUI) based on a computational environment for radiotherapy research (CERR) with MATLAB language. The MCVS GUI acts as an interface between the MCVS and a commercial treatment planning system to import the treatment plan, create MC input files, and analyze MC output dose files. The MCVS consists of the EGSnrc MC codes, which include EGSnrc/BEAMnrc to simulate the treatment head and EGSnrc/DOSXYZnrc to calculate the dose distributions in the patient/phantom. In order to improve computation time without approximations, an in-house cluster system was constructed. Results: The phase-space data of a 6-MV photon beam from a Varian Clinac unit was developed and used to establish several benchmarks under homogeneous conditions. The MC results agreed with the ionization chamber measurements to within 1%. The MCVS GUI could import and display the radiotherapy treatment plan created by the MC method and various treatment planning systems, such as RTOG and DICOM-RT formats. Dose distributions could be analyzed by using dose profiles and dose volume histograms and compared on the same platform. With the cluster system, calculation time was improved in line with the increase in the number of central processing units (CPUs) at a computation efficiency of more than 98%. Conclusions: Development of the MCVS was successful for performing MC simulations and analyzing dose distributions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MO-FG-303-05: A Feasibility Study of Using a Cherenkov Detector Material with the Prompt Gamma Range Verification Technique in Proton Therapy

Purpose: To simulate the feasibility of a Cherenkov glass material for the determination of the penetration depth of therapeutic proton beams in water. Methods: Proton pencil beams of various energies incident onto a water phantom with dimensions of 5 x 5 x 30 cm{sup 3} were used for simulation with the Geant4 toolkit. The model used standard electromagnetic packages, packages based on binary-cascade nuclear model, several decay modules (G4Decay, G4DecayPhysics, and G4RadioactiveDecayPhysics), and optical photon components (G4OpticalPhysics). A Cherenkov glass material was modeled as the detector medium (7.2 g of In2O3 + 90 g cladding, density of 2.82 g/cm{sup 3}, Zeff = 33.7, index of refraction n(600 nm) = 1.56, and energy threshold of production Eth = 156 keV ). The emitted secondary particles are analyzed characterizing their timing, energy, and angular distributions. A feasibility analysis was conducted for a simplistic detector system using this material to locate the position of the Bragg Peak. Results: The escaping neutrons have energies ranging from thermal to the incident proton energy and the escaping photons have energies >10 MeV. Photon peaks between 4 and 6 MeV were attributed to originate from direct proton interactions with {sup 12}C (∼ 4.4 MeV) and {sup 16}O (∼ 6 MeV), respectively. The escaping photons are emitted isotropically, while low (≤10 MeV) and high (>10 MeV) neutrons are isotropic and forward-directional, respectively. The emissions of photons are categorized into prompt (∼ns) and delayed (∼min) where the prompt photons include the 4.4 and 6 MeV. The Cherenkov material had on average <2% of neutron interactions while LYSO and BGO scintillators had a minimum of ∼50%. Our simplistic detector system was capable of discerning Bragg Peak locations using a timing discrimination of ∼50 ns. Conclusion: We investigate the viability of using the Cherenkov material for MeV photon detection medium for the prompt gamma technique.

60 APPLIED LIFE SCIENCES↗

Maintaining Continuity of Knowledge on Nuclear Waste Destined for Geological Repositories. A Case Study of Plutonium Shipments to the Waste Isolation Pilot Plant (WIPP)

This study examines methods that can help maximize confidence in maintaining Continuity of Knowledge (CoK) on plutonium-bearing wastes, from a final safeguards-verification measurement through emplacement underground. The study identifies Containment and Surveillance (C/S) measures that can be applied during packaging of plutonium wastes at the Savannah River Site (SRS) in South Carolina, USA, through shipment to, and receipt and disposal at the Waste Isolation Pilot Plant (WIPP) near Carlsbad, New Mexico, USA. Results of this study could apply to countries with a Comprehensive Safeguards Agreement (CSA) that plan to dispose in a geological repository plutonium or other non-fuel nuclear materials that are under international safeguards.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Independent calculation-based verification of IMRT plans using a 3D dose-calculation engine

Independent monitor unit verification of intensity-modulated radiation therapy (IMRT) plans requires detailed 3-dimensional (3D) dose verification. The aim of this study was to investigate using a 3D dose engine in a second commercial treatment planning system (TPS) for this task, facilitated by in-house software. Our department has XiO and Pinnacle TPSs, both with IMRT planning capability and modeled for an Elekta-Synergy 6 MV photon beam. These systems allow the transfer of computed tomography (CT) data and RT structures between them but do not allow IMRT plans to be transferred. To provide this connectivity, an in-house computer programme was developed to convert radiation therapy prescription (RTP) files as generated by many planning systems into either XiO or Pinnacle IMRT file formats. Utilization of the technique and software was assessed by transferring 14 IMRT plans from XiO and Pinnacle onto the other system and performing 3D dose verification. The accuracy of the conversion process was checked by comparing the 3D dose matrices and dose volume histograms (DVHs) of structures for the recalculated plan on the same system. The developed software successfully transferred IMRT plans generated by 1 planning system into the other. Comparison of planning target volume (TV) DVHs for the original and recalculated plans showed good agreement; a maximum difference of 2% in mean dose, − 2.5% in D95, and 2.9% in V95 was observed. Similarly, a DVH comparison of organs at risk showed a maximum difference of +7.7% between the original and recalculated plans for structures in both high- and medium-dose regions. However, for structures in low-dose regions (less than 15% of prescription dose) a difference in mean dose up to +21.1% was observed between XiO and Pinnacle calculations. A dose matrix comparison of original and recalculated plans in XiO and Pinnacle TPSs was performed using gamma analysis with 3%/3 mm criteria. The mean and standard deviation of pixels passing gamma tolerance for XiO-generated IMRT plans was 96.1 ± 1.3, 96.6 ± 1.2, and 96.0 ± 1.5 in axial, coronal, and sagittal planes respectively. Corresponding results for Pinnacle-generated IMRT plans were 97.1 ± 1.5, 96.4 ± 1.2, and 96.5 ± 1.3 in axial, coronal, and sagittal planes respectively.

61 RADIATION PROTECTION AND DOSIMETRY↗

A simple backprojection algorithm for 3D in vivo EPID dosimetry of IMRT treatments

Treatment plans are usually designed, optimized, and evaluated based on the total 3D dose distribution, motivating a total 3D dose verification. The purpose of this study was to develop a 2D transmission-dosimetry method using an electronic portal imaging device (EPID) into a simple 3D method that provides 3D dose information. In the new method, the dose is reconstructed within the patient volume in multiple planes parallel to the EPID for each gantry angle. By summing the 3D dose grids of all beams, the 3D dose distribution for the total treatment fraction is obtained. The algorithm uses patient contours from the planning CT scan but does not include tissue inhomogeneity corrections. The 3D EPID dosimetry method was tested for IMRT fractions of a prostate, a rectum, and a head-and-neck cancer patient. Planned and in vivo-measured dose distributions were within 2% at the dose prescription point. Within the 50% isodose surface of the prescribed dose, at least 97% of points were in agreement, evaluated with a 3D {gamma} method with criteria of 3% of the prescribed dose and 0.3 cm. Full 3D dose reconstruction on a 0.1x0.1x0.1 cm{sup 3} grid and 3D {gamma} evaluation took less than 15 min for one fraction on a standard PC. The method allows in vivo determination of 3D dose-volume parameters that are common in clinical practice. The authors conclude that their EPID dosimetry method is an accurate and fast tool for in vivo dose verification of IMRT plans in 3D. Their approach is independent of the treatment planning system and provides a practical safety net for radiotherapy.

61 RADIATION PROTECTION AND DOSIMETRY↗

WE-DE-BRA-01: SCIENCE COUNCIL JUNIOR INVESTIGATOR COMPETITION WINNER: Acceleration of a Limited-Angle Intrafraction Verification (LIVE) System Using Adaptive Prior Knowledge Based Image Estimation

Purpose: To develop an adaptive prior knowledge based image estimation method to reduce the scan angle needed in the LIVE system to reconstruct 4D-CBCT for intrafraction verification. Methods: The LIVE system has been previously proposed to reconstructs 4D volumetric images on-the-fly during arc treatment for intrafraction target verification and dose calculation. This system uses limited-angle beam’s eye view (BEV) MV cine images acquired from the treatment beam together with the orthogonally acquired limited-angle kV projections to reconstruct 4D-CBCT images for target verification during treatment. In this study, we developed an adaptive constrained free-form deformation reconstruction technique in LIVE to further reduce the scanning angle needed to reconstruct the CBCT images. This technique uses free form deformation with energy minimization to deform prior images to estimate 4D-CBCT based on projections acquired in limited angle (orthogonal 6°) during the treatment. Note that the prior images are adaptively updated using the latest CBCT images reconstructed by LIVE during treatment to utilize the continuity of patient motion.The 4D digital extended-cardiac-torso (XCAT) phantom was used to evaluate the efficacy of this technique with LIVE system. A lung patient was simulated with different scenario, including baseline drifts, amplitude change and phase shift. Limited-angle orthogonal kV and beam’s eye view (BEV) MV projections were generated for each scenario. The CBCT reconstructed by these projections were compared with the ground-truth generated in XCAT.Volume-percentage-difference (VPD) and center-of-mass-shift (COMS) were calculated between the reconstructed and the ground-truth tumors to evaluate the reconstruction accuracy. Results: Using orthogonal-view of 6° kV and BEV- MV projections, the VPD/COMS values were 12.7±4.0%/0.7±0.5 mm, 13.0±5.1%/0.8±0.5 mm, and 11.4±5.4%/0.5±0.3 mm for the three scenarios, respectively. Conclusion: The technique enables LIVE to accurately reconstruct 4D-CBCT images using only orthogonal 6° angle, which greatly improves the efficiency and reduces dose of LIVE for intrafraction verification.

60 APPLIED LIFE SCIENCES↗

Verification and Performance Impact of the New Parallel MCNP6.3 Particle Track Output Capability for Subcritical Multiplication Simulations

The MCNP6® code, version 6.3, has several new features that are intended to ultimately replace legacy features that are now marked for deprecation. One of these features is the new particle track output (PTRAC) format and capability, where the legacy PTRAC capability still exists alongside the modern PTRAC capability in MCNP6.3. While the MCNP6.3 code has been extensively verified and validated for many applications, the PTRAC feature is not exercised in any of the typical verification and validation (V&V) applications studied during the course of a typical MCNP code release. The primary goal of this paper is to verify that the legacy and modern PTRAC feature produces equivalent results for subcritical multiplication benchmarks previously studied. In the process of verifying that the simulated benchmark results are equivalent, the computational performance is compared between the legacy and modern PTRAC uses. In addition to verification of the update, which is important to the community as a whole, this effort also supports advances in the simulation of recent subcritical neutron noise measurements that require higher computational effort per second of real-time measurement than that of systems typically measured.

97 MATHEMATICS AND COMPUTING↗