Search NASA⌕ Search

SEARCH · Search NASA

Results for “Volatile analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

The Mars Crustal Magnetic Field Control of Plasma Boundary Locations and Atmospheric Loss: MHD Prediction and Comparison with MAVEN

We present results from a global Mars time-dependent MHD simulation under constant solar wind and solar radiation impact considering inherent magnetic field variations due to continuous planetary rotation. We calculate the 3-D shapes and locations of the bow shock (BS) and the induced magnetospheric boundary (IMB) and then examine their dynamic changes with time. We develop a physics-based, empirical algorithm to effectively summarize the multidimensional crustal field distribution. It is found that by organizing the model results using this new approach, the Mars crustal field shows a clear, significant influence on both the IMB and the BS. Specifically, quantitative relationships have been established between the field distribution and the mean boundary distances and the cross-section areas in the terminator plane for both of the boundaries. The model-predicted relationships are further verified by the observations from the NASA Mars Atmosphere and Volatile EvolutioN (MAVEN) mission. Our analysis shows that the boundaries are collectively affected by the global crustal field distribution, which, however, cannot be simply parameterized by a local parameter like the widely used subsolar longitude. Our calculations show that the variability of the intrinsic crustal field distribution in Mars-centered Solar Orbital itself may account for approx.60% of the variation in total atmospheric loss, when external drivers are static. It is found that the crustal field has not only a shielding effect for atmospheric loss but also an escape-fostering effect by positively affecting the transterminator ion flow cross-section area.

Global↗

Early Hydrodynamic Escape Limits Rocky Planets to Less Than or Equal to 1.6 Earth Radii

In the past decade thousands of exoplanet candidates and hundreds of confirmed exoplanets have been found. For sub-Neptune-sized planets, those less than approx. 10 Earth masses, we can separate planets into two broad categories: predominantly rocky planets, and gaseous planets with thick volatile sheaths. Observations and subsequent analysis of these planets show that rocky planets are only found with radii less than approx. 1.6 Earth radii. No rocky planet has yet been found that violates this limit. We propose that hydrodynamic escape of hydrogen rich protoatmospheres, accreted by forming planets, explains the limit in rocky planet size. Following the hydrodynamic escape model employed by Luger et al. (2015), we modelled the XUV driven escape from young planets (less than approx.100 Myr in age) around a Sun-like star. With a simple, first-order model we found that the rocky planet radii limit occurs consistently at approx. 1.6 Earth radii across a wide range of plausible parameter spaces. Our model shows that hydrodynamic escape can explain the observed cutoff between rocky and gaseous planets. Fig. 1 shows the results of our model for rocky planets between 0.5 and 10 Earth masses that accrete 3 wt. % H2/He during formation. The simulation was run for 100 Myr, after that time the XUV flux drops off exponentially and hydrodynamic escape drops with it. A cutoff between rocky planets and gaseous ones is clearly seen at approx. 1.5-1.6 Earth radii. We are only interested in the upper size limit for rocky planets. As such, we assumed pure hydrogen atmospheres and the highest possible isothermal atmospheric temperatures, which will produce an upper limit on the hydrodynamic loss rate. Previous work shows that a reasonable approximation for an upper temperature limit in a hydrogen rich protoatmosphere is 2000-3000 K, consistent with our assumptions. From these results, we propose that the observed dichotomy between mini-Neptunes and rocky worlds is simply explained by an early episode of thermally-driven hydrodynamic escape when host stars have saturated XUV fluxes.

Lehmer, O. R.↗

Headspace analysis of foams and fixatives

In the process of decontaminating and decommissioning (D&D) older nuclear facilities, special precautions must be taken with removable or airborne contamination. One possible strategy utilizes foams and fixatives to affix these loose contaminants. Many foams and fixatives are already commercially available, either generically or sold specifically for D&D. However, due to a lack of revelant testing in a radioactive environment, additional verification is needed to confirm that these products not only affix contamination to their surfaces, but also will function in a D&D environment. Several significant safety factors, including flammability and worker safety, can be analyzed through the process of headspace analysis, a technique that analyzes the off gas formed before or during the curing process of the foam/fixative, usually using gas chromatography-mass spectrometry (GC-MS). This process focuses on the volatile components of a chemical, which move freely between the solid/liquid form within the sample and the gaseous form in the area above the sample (the headspace). Between possibly hot conditions in a D&D situation and heat created in a foaming reaction, the volatility of many chemicals can change, and thus different gasses can be released at different times throughout the reaction. This project focused on analysis of volatile chemicals involved in the process of using foams and fixatives to identify any potential hazardous or flammable compounds.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Novel method for cleaning a vacuum chamber from hydrocarbon contamination

A novel method for cleaning a high vacuum chamber is presented. This method is based on concurrent in situ high-energetic UV light activation of contaminants located in the residual gas and at the vacuum chamber surfaces as well as the in situ generation of highly reactive ozone. Ozone oxidizes the contaminants to volatile species. Investigations by energy-dispersive x-ray analysis of residual gas depositions and mass-spectroscopy measurements of the residual gas in the vacuum chamber identify the contaminant species as hydrocarbons. After a cleaning period of 8 h, a decrease in measured chamber contamination by about 90% could be achieved according to atomic force microscope analysis. Mass spectroscopy measurements using a residual gas analyzer indicate the creation of volatile, carbonaceous species during the cleaning process.

36 MATERIALS SCIENCE↗

Why do Ladybugs Smell Bad? In-vivo Quantification of Odorous Insect Kairomones with SPME and Multidimensional GC-MS-Olfactometry

Winemakers, small fruit growers, and homeowners are concerned with noxious compounds released by multicolored Asian ladybird beetles (Harmonia axyridis, Coleoptera: Coccinellidae). New method based on headspace solid phase microextraction (HS-SPME) coupled with multidimensional gas chromatography mass spectrometry--olfactometry (MDGC-MS-O) system was developed for extraction, isolation and simultaneous identification of compounds responsible for the characteristic odor of live H. axyridis. Four methoxypyrazines (MPs) were identified in headspace volatiles of live H. axyridis as those responsible for the characteristic odor: 2, 5-dimethy1-3-methoxypyrazine (DMMP), 2-isopropy1-3-methoxypyrazine (IPMP), 2-sec-buty1-3-methoxypyrazine (SBMP), and 2-isobuty1-3-methoxypyrazine (IBMP). To the best of our knowledge this is the first report of H. axyridis releasing DMMP and the first report of this compound being a component of the H. axyridis characteristic odor. Quantification of three MPs (IPMP, SBMP and IBMP) emitted from live H. axyridis were performed using external calibration with HS-SPME and direct injections. A linear relationship (R{sup 2}>0.9958 for all 3 MPs) between MS response and concentration of standard was observed over a concentration range from 0.1 ng L{sup -1} to 0.05 {mu}g L{sup -1} for HS-SPME-GC-MS. The method detection limits (MDL) based on multidimensional GC-MS approach for three MPs were estimated to be between 0.020 ng L{sup -1}. to 0.022 ng L{sup -1}. This methodology is applicable for in vivo determination of odor-causing chemicals associated with emissions of volatiles from insects.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Role of Technical Guidance and Analysis Tools in Remedy Decisions, Implementation, and Closure - 18307

Selection, design, and implementation of environmental remedies are conducted under regulatory frameworks that define the activities, communication, and documentation requirements for the remediation process. However, there are site situations that are not well described in the basic regulatory frameworks, and technical guidance and analysis tools can help facilitate remedy decisions and actions. An example where technical guidance and analysis tools are helpful is in the transition from pump-and-treat (P and T) remediation to monitored natural attenuation (MNA). Standard MNA regulatory guidance does not account for a plume initially controlled by P and T hydraulic conditions rather than natural-gradient conditions. For instance, MNA guidance discusses demonstrating plume stability as a means to evaluate the suitability of MNA. However, plume stability under long-term natural gradient conditions cannot be directly demonstrated while the plume is being contained by a P and T system. Thus, additional guidance is needed to describe other measures that can be used to support transition from P and T to MNA. As an additional example, standard MNA regulatory guidance is not written to provide suitable information for application to vadose-zone contamination; discussion and examples in the regulatory guidance are predominantly for groundwater. Use of contaminant transport assessments is an important component of vadose-zone remedy decisions where technical guidance and analysis tools can facilitate these decisions. For volatile compounds, the assessment may need to also consider flux to the surface and constraints associated with vapor intrusion. Recent technical guidance and associated analysis tools provide sites with approaches to support remedy decisions for the above conditions. In particular, these recent approaches target developing and implementing P and T and soil vapor extraction remediation exit strategies and facilitating assessment and implementation of remedies for coupled vadose-zone/groundwater contamination. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Sinus Viscositatis: Implications of Young, KREEPy Mare Eruptions for Lunar Volatile Abundances and Origins

Volatiles such as H 2 O and OH have been conclusively shown to exist across the Moon following over a decade of detailed sample analysis and remote sensing. Several mechanisms deliver volatiles to the lunar surface, including exogenous sources such as asteroid or comet bombardment (i.e., H 2 O, CO 2 , CH 4 , NH 3 , S), solar wind (i.e., H, He, Ne, Ar, Na, C, O), and galactic cosmic rays (i.e., noble gases like Xe), or endogenous sources such as outgassing from igneous lithologies (i.e., H 2 O, OH, CO 2 , S, Ar, Cl, F). Processes such as impact gardening and temperature-driven adsorption/desorption have likely supported further transport of species across the lunar surface, thus a mixture of sources is thought to be preserved. Nonetheless, volatile origins, abundances, and cycling on the Moon are not well understood and require further investigation.

A. J. Gawronska↗

First Detection of Non-Chlorinated Organic Molecules Indigenous to a Martian Sample

The Sample Analysis at Mars (SAM) instrument onboard Curiosity can perform pyrolysis of martian solid samples, and analyze the volatiles by direct mass spectrometry in evolved gas analysis (EGA) mode, or separate the components in the GCMS mode (coupling the gas chromatograph and the mass spectrometer instruments). In addition, SAM has a wet chemistry laboratory designed for the extraction and identification of complex and refractory organic molecules in the solid samples. The chemical derivatization agent used, N-methyl-N-tert-butyldimethylsilyl- trifluoroacetamide (MTBSTFA), was sealed inside seven Inconel metal cups present in SAM. Although none of these foil-capped derivatization cups have been punctured on Mars for a full wet chemistry experiment, an MTBSTFA leak was detected and the resultant MTBSTFA vapor inside the instrument has been used for a multi-sol MTBSTFA derivatization (MD) procedure instead of direct exposure to MTBSTFA liquid by dropping a solid sample directly into a punctured wet chemistry cup. Pyr-EGA, Pyr-GCMS and Der-GCMS experiments each led to the detection and identification of a variety of organic molecules in diverse formations of Gale Crater.

Freissinet, C.↗

The Tribological Properties of Several Silahydrocarbons for Use in Space Mechanisms

Silahydrocarbons are members of a relatively new class of liquid lubricants with great potential for use in space mechanisms. They are unimolecular species consisting of silicon, carbon, and hydrogen. They possess unique wear, viscosity, and volatility properties while retaining the ability to solubilize conventional additives. The tribological properties of several members of this class, including tri, tetra- and penta-compounds, are presented. These properties include: viscosity-temperature (ASTM D446), viscosity-pressure coefficient, vapor pressure, volatility, lubricant lifetimes, traction, reciprocating and four ball wear rates and bearing performance. Lubricant lifetimes were determined using a vacuum ball bearing simulator, the spiral orbit tribometer (SOT). Wear was measured using a Cameron Plint reciprocating tribometer and wear rates with a vacuum four ball tribometer. Conventional viscometry was used for viscosity-temperature measurements and a Knudsen cell for vapor pressure. Vacuum Thermogravimetric Analysis (TGA) was also used for volatility measurements. Pressure viscosity coefficients (a values) were estimated from EHL (elastohydrodynamic lubrication) film thickness measurements. Traction coefficients were measured with a twin disk traction rig. Bearing tests were performed in a vacuum bearing test facility. These properties are compared to existing state-of-the-art space lubricants.

Jones, W. R., Jr.↗

Chemical studies of H chondrites. 6: Antarctic/non-Antarctic compositional differences revisited

We report data for the trace elements Au, Co, Sb, Ga, Rb, Ag, Se, Cs, Te, Zn, Cd, Bi, T1, and In (ordered by putative volatility during nebular condensation and accretion) determined by radiochemical neutron activation analysis of 14 additional H5 and H6 chondrite falls. Data for the 10 most volatile elements (Rb to In) treated by the multivariate techniques of linear discriminant analysis and logistic regression in these and 44 other falls are compared with those of 59 H4-6 chondrites from Antarctica. Various populations are tested by the multivariate techniques, using the previously developed method of randomization-simulation to assess significance levels. An earlier conclusion, based on fewer examples, that H4-6 chondrite falls are compositionally distinguishable from the Antarctic suite is verified by the additional data. This distinctiveness is highly significant because of the presence of samples from Victoria Land in the Antarctic population, which differ compositionally from falls beyond any reasonable doubt. However, it cannot be proven unequivocally that falls and Antarctic samples from Queen Maud Land are compositionally distinguishable. Trivial causes (e.g., analyst bias, weathering) cannot explain the Victoria Land (Antarctic)/non-Antarctic compositional difference for paradigmatic H4-6 chondrites. This seems to reflect a time-dependent variation of near-Earth meteoroid source regions differing in average thermal history.

Wolf, Stephen F.↗

Etch Products of Copper Atomic Layer Etching by Oxidation and Formic Acid Vapor

Atomic layer etching (ALE) of metals offers a path to greater control of selectivity, etch rate, and etch profile. However, tailoring a process to meet these demands requires an understanding of the volatile etch product, which is challenging to detect due to low product concentrations and the paramagnetism of many metalorganic products. Here, in this work, several complementary analysis techniques were used to determine the volatile etch product and residual surface species of a Cu ALE process based on plasma oxidation and formic acid vapor etching of the oxidized layer. It was shown that the volatile product was copper formate with a Cu 2+ paramagnetic center, in concordance with prior density functional theory (DFT) calculations. While copper formate tetrahydrate was formed, it was determined that the tetrahydrate product was confined to the surface, with anhydrous copper formate being the volatile etch product.

Smith, Taylor G. [Univ. of California, Los Angeles↗

Technical basis for the reduction of the maximum temperature TGA-MS analysis of oxide samples from the 3013 destructive examination program

Thermogravimetric analysis with mass spectroscopy of the evolved gas (TGA-MS) is used to quantify the moisture content of materials in the 3013 destructive examination (3013 DE) surveillance program. Salts frequently present in the 3013 DE materials volatilize in the TGA and condense in the gas lines just outside the TGA furnace. The buildup of condensate can restrict the flow of purge gas and affect both the TGA operations and the mass spectrometer calibration. Removal of the condensed salts requires frequent maintenance and subsequent calibration runs to keep the moisture measurements by mass spectroscopy within acceptable limits, creating delays in processing samples. In this report, the feasibility of determining the total moisture from TGA-MS measurements at a lower temperature is investigated. A temperature of the TGA-MS analysis which reduces the complications caused by the condensation of volatile materials is determined. Analysis shows that an excellent prediction of the presently measured total moisture value can be made using only the data generated up to 700 °C and there is a sound physical basis for this estimate. It is recommended that the maximum temperature of the TGA-MS determination of total moisture for the 3013 DE program be reduced from 1000 °C to 700 °C. It is also suggested that cumulative moisture measurements at 550 °C and 700°C be substituted for the measured value of total moisture in the 3013 DE database. Using these raw values, any of predictions of the total moisture discussed in this report can be made.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hypervolatiles in a Jupiter-Family Comet: Observations of 45P/Honda-Mrkos-Pajdusakova Using iSHELL at the NASA-IRTF

We used the new high spectral resolution cross-dispersed facility spectrograph, iSHELL, at the NASA Infrared Telescope Facility on Maunakea, HI, to observe Jupiter-family comet (JFC) 45P/Honda-Mrkos-Pajdusakova. We report water production rates, as well as production rates and abundance ratios relative to H2O, for eight trace parent molecules (native ices), CO, CH4, H2CO, CH3OH, HCN, NH3, C2H2, and C2H6, on 2 days spanning UT 2017 January 6/7 and 7/8, shortly following perihelion. Trace species were measured simultaneously with H2O and/or OH prompt emission, a proxy for H2O production, thereby providing a robust and consistent means of establishing the native ice composition of 45P. Its favorable geocentric radial velocity (approximately minus 35 kilometers per second) permitted sensitive measures of the "hypervolatiles" CO and CH4, which are substantially undercharacterized in JFCs. Our results represent the most precise ground-based measures of CO and CH4 to date in a JFC, providing a foundation for building meaningful statistics regarding their abundances. The abundance ratio for CH4 in 45P (0.79 percent plus or minus 0.06 percent relative to H2O) was consistent with its median value as measured among Oort Cloud comets, whereas CO (0.60 percent plus or minus 0.04 percent) was strongly depleted. Compared with all measured comets, HCN (0.049 percent plus or minus 0.012 percent) was strongly depleted, CH3OH (3.6 percent plus or minus 0.3 percent) was enriched, and the remaining species were consistent with their respective median abundances. The volatile composition measured for 45P could indicate processing of ices prior to their incorporation into its nucleus. Spatial analysis of emissions suggests enhanced release of more volatile species into the sunward-facing hemisphere of the coma.

DiSanti, Michael A.↗

INVESTIGATION OF THE TOTAL ORGANIC HALOGEN ANALYTICAL METHOD AT THE WASTE SAMPLING AND CHARACTERIZATION FACILITY

Total organic halogen (TOX) is used as a parameter to screen groundwater samples at the Hanford Site. Trending is done for each groundwater well, and changes in TOX and other screening parameters can lead to costly changes in the monitoring protocol. The Waste Sampling and Characterization Facility (WSCF) analyzes groundwater samples for TOX using the United States Environmental Protection Agency (EPA) SW-S46 method 9020B (EPA 1996a). Samples from the Soil and Groundwater Remediation Project (SGRP) are submitted to the WSCF for analysis without information regarding the source of the sample; each sample is in essence a ''blind'' sample to the laboratory. Feedback from the SGRP indicated that some of the WSCF-generated TOX data from groundwater wells had a number of outlier values based on the historical trends (Anastos 200Sa). Additionally, analysts at WSCF observed inconsistent TOX results among field sample replicates. Therefore, the WSCF lab performed an investigation of the TOX analysis to determine the cause of the outlier data points. Two causes were found that contributed to generating out-of-trend TOX data: (1) The presence of inorganic chloride in the groundwater samples: at inorganic chloride concentrations greater than about 10 parts per million (ppm), apparent TOX values increase with increasing chloride concentration. A parallel observation is the increase in apparent breakthrough of TOX from the first to the second activated-carbon adsorption tubes with increasing inorganic chloride concentration. (2) During the sample preparation step, excessive purging of the adsorption tubes with oxygen pressurization gas after sample loading may cause channeling in the activated carbon bed. This channeling leads to poor removal of inorganic chloride during the subsequent wash step with aqueous potassium nitrate. The presence of this residual inorganic chloride then produces erroneously high TOX values. Changes in sample preparation were studied to more effectively remove inorganic chloride from the activated-carbon adsorption tubes. With the TOX sample preparation equipment and TOX analyzers at WSCF, the nitrate wash recommended by EPA SW-846 method 9020B was found to be inadequate to remove inorganic chloride interference. Increasing the nitrate wash concentration from 10 grams per liter (g/L) to 100 giL potassium nitrate and increasing the nitrate wash volume from 3 milliliters (mL) to 10 mL effectively removed the inorganic chloride up to at least 100 ppm chloride in the sample matrix. Excessive purging of the adsorption tubes during sample preparation was eliminated. These changes in sample preparation have been incorporated in the analytical procedure. The results using the revised sample preparation procedure show better agreement of TOX values both for replicate analyses of single samples and for the analysis of replicate samples acquired from the same groundwater well. Furthermore, less apparent adsorption tube breakthrough now occurs with the revised procedure. One additional modification made to sample preparation was to discontinue the treatment of groundwater samples with sodium bisulfite. Sodium bisulfite is used to remove inorganic chlorine from the sample; inorganic chlorine is not expected to be a constituent in these groundwater samples. Several other factors were also investigated as possible sources of anomalous TOX results: (1) Instrument instability: examination of the history of results for TOX laboratory control samples and initial calibration verification standards indicate good long-term precision for the method and instrument. Determination of a method detection limit of 2.3 ppb in a deionized water matrix indicates the method and instrumentation have good stability and repeatability. (2) Non-linear instrument response: the instrument is shown to have good linear response from zero to 200 parts per billion (ppb) TOX. This concentration range encompasses the majority of samples received at WSCF for TOX analysis. Linear response was checked using both non-volatile TOX species (trichlorophenol) and volatile TOX species. Average recoveries of the volatile TOX species ranged between 50% and 75%. (3) Improper sample preservation: ion-chromatographic analysis of several samples with anomalous TOX results revealed that the samples were properly preserved with sulfuric acid and not hydrochloric acid.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Adsorption properties of carbonized polyacrylonitrile deposited on {gamma}-alumina and silica gel by precipitation polymerization

The precipitation polymerization method was used for the deposition of various contents of polyacrylonitrile on two oxide-type supports ({gamma}-alumina and silica gel). The synthesized materials were characterized by thermal analysis performed in inert and oxidizing atmospheres. The mechanism of polyacrylonitrile decomposition was proposed. In order to gain effective adsorbents of volatile organic compounds the polyacrylonitrile/support composites were carbonized at elevated temperatures. The texture and morphology of the calcined materials were examined by low-temperature sorption of N{sub 2} and scanning electron microscopy, respectively. An influence of thermal treatment conditions and carbonaceous species loading on adsorption capacity of methyl-ethyl ketone vapour was also determined. Attenuated total reflection Fourier transform infrared spectroscopy measurements revealed that the ladder-type polyacrylonitrile species formed above 250 {sup o}C and stable up to about 350-400 {sup o}C are the most effective sites for methyl-ethyl ketone sorption. The carbonaceous species dispersion was found to be an additional factor influencing the adsorption capacity of the carbonized polyacrylonitrile/support composites.

36 MATERIALS SCIENCE↗

Analysis of Hybrid Gas–Dust Outbursts Observed at 67P/Churyumov–Gerasimenko

Cometary outbursts offer a valuable window into the composition of comet nuclei with their forceful ejection of dust and volatiles in explosive events, revealing the interior components of the comet. Understanding how different types of outbursts influence the dust properties and volatile abundances, to better interpret what signatures can be attributed to primordial composition and what features are the result of processing, is an important task best undertaken with a multi-instrument approach. The European Space Agency Rosetta mission to 67P/Churyumov–Gerasimenko carried a suite of instruments capable of carrying out this task in the near-nucleus coma with unprecedented spatial and spectral resolution. In this work, we discuss two outbursts that occurred 2015 November 7 and were observed by three instruments on board: the Alice ultraviolet spectrograph, the Visual Infrared and Thermal Imaging Spectrometer, and the Optical, Spectroscopic, and Infrared Remote Imaging System. Together, the observations show that mixed gas and dust outbursts can have different spectral signatures representative of their initiating mechanisms, with the first outburst showing indicators of a cliff collapse origin and the second more representative of fresh volatiles being exposed via a deepening fracture. This analysis opens up the possibility of remote spectral classification of cometary outbursts with future work.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Oxidation of Volatile Organic Compounds as the Major Source of Formic Acid in a Mixed Forest Canopy

Formic acid (HCOOH) is among the most abundant carboxylic acids in the atmosphere, but its budget is poorly understood. We present eddy flux, vertical gradient, and soil chamber measurements from a mixed forest and apply the data to better constrain HCOOH source/sink pathways. While the cumulative above-canopy flux was downward, HCOOH exchange was bidirectional, with extended periods of net upward and downward flux. Net above-canopy fluxes were mostly upward during warmer/drier periods. The implied gross canopy HCOOH source corresponds to 3% and 38% of observed isoprene and monoterpene carbon emissions and is 15× underestimated in a state-of-science atmospheric model (GEOS-Chem). Gradient and soil chamber measurements identify the canopy layer as the controlling source of HCOOH or its precursors to the forest environment; below-canopy sources were minor. A correlation analysis using an ensemble of marker volatile organic compounds suggests that secondary formation, not direct emission, is the major source driving ambient HCOOH.

58 GEOSCIENCES↗

The Effect of Glass Chemistry on Caesium Volatility in Iron Phosphate Glass Systems - 19344

The UK currently has a stockpile of 99,000 m{sup 3} of intermediate level waste (ILW), with this figure expected to rise to 191,000 m{sup 3} by 2125. Current immobilisation options include cementation and thermal treatment, with cementation being the preferred candidate due to the simplicity of processing. However, thermal processing such as vitrification could offer significant volume reductions, up to 75 % for some waste-streams. In comparison, cementation is generally associated with a volume increase, with a typical waste package seeing a volume increase of 200 - 400 %. For vitrification to be accepted as the preferred treatment option of ILW in the UK, the issue of volatility during the vitrification process must be addressed. Volatile components of ILW such as Cs-137 and Sr-90 account for almost 50 % of the current total radioactivity produced by the UK's ILW stockpile. Therefore, the efficient retention of these elements into the glass immobilisation medium must be considered. Various approaches can be employed when trying to increase volatile retention, however this project has focussed on the influence of glass chemistry on volatility. A series of iron phosphate glasses containing 5 mol % of B{sub 2}O{sub 3}, MnO and ZnO have been produced, where additives have been substituted in place of Fe{sub 2}O{sub 3} in a standard 40Fe{sub 2}O{sub 3}-60P{sub 2}O{sub 5} system. All glass samples were characterised using Raman spectroscopy, SEM-EDX, thermal analysis, XRD and XRF. The glasses were then doped with caesium carbonate and re-melted in the system described below. A simple off-gas system has been developed and commissioned to capture and characterise volatiles released from the glass during melting. The off-gas system has been refined several times, with the most recent design comprising of a sealed stainless steel system, connected to two gas washing bottles containing 150 ml of 50 % nitric acid. Nitrogen gas is passed through the system for the duration of the experiment at a flow rate of ∼ 0.9 L/min to ensure efficient carryover of the volatiles released from the glass melt into the solutions in the gas washing bottles. The total retention of the volatiles can be measuring by analysing the contents of the gas washing bottles using ICP-MS and XRF of the final glass product. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗