Search NASA⌕ Search

SEARCH · Search NASA

Results for “X ray”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Color–color diagrams as tools for assessment of the variable absorption in high mass X-ray binaries

High mass X-ray binaries hold the promise of allowing us to understand the structure of the winds of their supermassive companion stars by using the emission from the compact object as a backlight to evaluate the variable absorption in the structured stellar wind. The wind along the line of sight can change on timescales as short as minutes and below. However, such short timescales are not available for the direct measurement of absorption through X-ray spectroscopy with the current generation of X-ray telescopes. In this paper, we demonstrate the usability of color–color diagrams for assessing the variable absorption in wind accreting high mass X-ray binary systems. Furthermore, we employ partial covering models to describe the spectral shape of high mass X-ray binaries and assess the implication of different absorbers and their variability on the shape of color–color tracks. We show that in taking into account, the ionization of the absorber, and in particular accounting for the variation of ionization with absorption depth, is crucial to describe the observed behavior well.

79 ASTRONOMY AND ASTROPHYSICS↗

Accurate contrast determination for X-ray speckle visibility spectroscopy

X-ray speckle visibility spectroscopy using X-ray free-electron lasers has long been proposed as a probe of fast dynamics in noncrystalline materials. In this paper, numerical modeling is presented to show how the data interpretation of visibility spectroscopy can be impacted by the nonidealities of real-life X-ray detectors. Using simulated detector data, this work provides a detailed analysis of the systematic errors of several contrast extraction algorithms in the context of low-count-rate X-ray speckle visibility spectroscopy and their origins are discussed. Here, it was found that the finite detector charge cloud and pixel size lead to an unavoidable `degeneracy' in photon position determination, and that the contrasts extracted using different algorithms can all be corrected by a simple linear model. The results suggest that experimental calibration of the correction coefficient at the count rate of interest is possible and essential. This allows computationally lightweight algorithms to be implemented for on-the-fly analysis.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Serial Moire scanning phase contrast x-ray imaging

Method include emitting x-rays from an x-ray source, directing a first portion of the x-rays through an object grating situated adjacent to an object while the object is scanned relative to the object grating along a scan direction, directing a second portion of the x-rays through the object and subsequently through a detector grating without transmitting through the object grating, wherein the object grating and detector grating are adjacently arranged in a field of view of the x-rays sequentially with respect to each other in the scan direction, and receiving the first portion transmitted through the object and object grating with a first portion of a detector and receiving the second portion transmitted through the object and the detector grating with a second portion of the detector adjacent to the first portion of the detector. Systems are also disclosed, along with related techniques for beam hardening correction.

Miller, Erin A.↗

Two-dimensional correlation analysis for x-ray photoelectron spectroscopy

Abstract X-ray photoelectron spectroscopy (XPS) measures the binding energy of core-level electrons, which are well-localised to specific atomic sites in a molecular system, providing valuable information on the local chemical environment. The technique relies on measuring the photoelectron spectrum upon x-ray photoionisation, and the resolution is often limited by the bandwidth of the ionising x-ray pulse. This is particularly problematic for time-resolved XPS, where the desired time resolution enforces a fundamental lower limit on the bandwidth of the x-ray source. In this work, we report a novel correlation analysis which exploits the correlation between the x-ray and photoelectron spectra to improve the resolution of XPS measurements. We show that with this correlation-based spectral-domain ghost imaging method we can achieve sub-bandwidth resolution in XPS measurements. This analysis method enables XPS for sources with large bandwidth or spectral jitter, previously considered unfeasible for XPS measurements.

47 OTHER INSTRUMENTATION↗

MeVXRay-23A: We aim to increase the laser-driven MeV x-ray yield to ~ 4-6 Rads/shot (~2-3X increase) using novel target designs suitable for weapons radiography [Slides]

The purpose of this experiment is to evaluate enhanced laser-plasma coupling using near-critical foam padded tungsten cube targets and it’s effect on the laser-driven MeV x-ray dose. Compact MeV x-ray sources with <200µm source size in the several Rads/shot are needed for weapons radiography. The goal is to increase laser-driven MeV x-ray dose by ~2-3X.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

In-orbit operation of Resolve Filter Wheel and modulated X-ray source

The Resolve soft X-ray spectrometer is a high spectral resolution microcalorimeter spectrometer for the X-ray Imaging and Spectroscopy Mission. In the beam of Resolve, there is a filter wheel containing X-ray filters. In the beam, there is also an active calibration source, the modulated X-ray source (MXS), which can provide pulsed X-rays to facilitate gain calibration. The filter wheel consists of six filter positions. Two open positions, one 55 Fe source to aid in spectrometer characterization during the commissioning phase, and three transmission filters: a neutral density filter, an optical blocking filter, and a beryllium filter. The X-ray intensity, pulse period, and pulse separation of an MXS are highly configurable. Furthermore, the switch-on time is synchronized with the spacecraft’s internal clock to give accurate start and end times of the pulses. One of the issues raised during ground testing was the susceptibility of an MXS at high voltage to ambient light. Although measures were taken to mitigate the light leak, the efficacy of those measures must be verified in orbit. Along with an overview of issues raised during ground testing, we will discuss the calibration source and the filter performance in-flight and compare with the transmission curves present in the Resolve calibration database.

X-ray Imaging and Spectroscopy Mission/Resolve↗

A machine learning photon detection algorithm for coherent x-ray ultrafast fluctuation analysis

X-ray free electron laser experiments have brought unique capabilities and opened new directions in research, such as creating new states of matter or directly measuring atomic motion. One such area is the ability to use finely spaced sets of coherent x-ray pulses to be compared after scattering from a dynamic system at different times. This enables the study of fluctuations in many-body quantum systems at the level of the ultrafast pulse durations, but this method has been limited to a select number of examples and required complex and advanced analytical tools. By applying a new methodology to this problem, we have made qualitative advances in three separate areas that will likely also find application to new fields. As compared to the “droplet-type” models, which typically are used to estimate the photon distributions on pixelated detectors to obtain the coherent x-ray speckle patterns, our algorithm achieves an order of magnitude speedup on CPU hardware and two orders of magnitude improvement on GPU hardware. We also find that it retains accuracy in low-contrast conditions, which is the typical regime for many experiments in structural dynamics. Finally, it can predict photon distributions in high average-intensity applications, a regime which up until now has not been accessible. Our artificial intelligence-assisted algorithm will enable a wider adoption of x-ray coherence spectroscopies, by both automating previously challenging analyses and enabling new experiments that were not otherwise feasible without the developments described in this work.

47 OTHER INSTRUMENTATION↗

Laue-DIALS: Open-source software for polychromatic x-ray diffraction data

Most x-ray sources are inherently polychromatic. Polychromatic (“pink”) x-rays provide an efficient way to conduct diffraction experiments as many more photons can be used and large regions of reciprocal space can be probed without sample rotation during exposure—ideal conditions for time-resolved applications. Analysis of such data is complicated, however, causing most x-ray facilities to discard >99% of x-ray photons to obtain monochromatic data. Key challenges in analyzing polychromatic diffraction data include lattice searching, indexing and wavelength assignment, correction of measured intensities for wavelength-dependent effects, and deconvolution of harmonics. We recently described an algorithm, Careless, that can perform harmonic deconvolution and correct measured intensities for variation in wavelength when presented with integrated diffraction intensities and assigned wavelengths. Here, we present Laue-DIALS, an open-source software pipeline that indexes and integrates polychromatic diffraction data. Laue-DIALS is based on the dxtbx toolbox, which supports the DIALS software commonly used to process monochromatic data. As such, Laue-DIALS provides many of the same advantages: an open-source, modular, and extensible architecture, providing a robust basis for future development. We present benchmark results showing that Laue-DIALS, together with Careless, provides a suitable approach to the analysis of polychromatic diffraction data, including for time-resolved applications.

97 MATHEMATICS AND COMPUTING↗

Two-Component Multireference Restricted Active Space Configuration Interaction for the Computation of L-Edge X-ray Absorption Spectra

X-ray absorption spectroscopy is a powerful probe of local electronic and nuclear structure, providing insights into chemical processes. The theoretical prediction and interpretation of metal L-edge X-ray absorption spectra is complicated by both relativistic effects, including spin-orbit coupling, and by the multiconfigurational nature of the states involved. This work details an exact two-component multireference restricted active space configuration interaction (X2C-MRRASCI) scheme that uses an exact two-component state average complete active space self-consistent-field method (X2C-SA-CASSCF), which includes the spin-orbit coupling in a variational manner, for the accurate description of the electronic structure before using a restricted active space configuration interaction method to describe the core excited states of the X-ray spectrum. Benchmark calculations are presented for a series of iron containing complexes, with results showing key features of the spectrum being reproduced, including ligand to metal charge transfer and shake-up excitations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Low-temperature nanoscale heat transport in a gadolinium iron garnet heterostructure probed by ultrafast x-ray diffraction

Time-resolved x-ray diffraction has been used to measure the low-temperature thermal transport properties of a Pt/Gd3Fe5O12//Gd3Ga5O12 metal/oxide heterostructure relevant to applications in spin caloritronics. A pulsed femtosecond optical signal produces a rapid temperature rise in the Pt layer, followed by heat transport into the Gd3Fe5O12 (GdIG) thin film and the Gd3Ga5O12 (GGG) substrate. The time dependence of x-ray diffraction from the GdIG layer was tracked using an accelerator-based femtosecond x-ray source. The ultrafast diffraction measurements probed the intensity of the GdIG (1 −1 2) x-ray reflection in a grazing-incidence x-ray diffraction geometry. The comparison of the variation of the diffracted x-ray intensity with a model including heat transport and the temperature dependence of the GdIG lattice parameter allows the thermal conductance of the Pt/GdIG and GdIG//GGG interfaces to be determined. Complementary synchrotron x-ray diffraction studies of the low-temperature thermal expansion properties of the GdIG layer provide a precise calibration of the temperature dependence of the GdIG lattice parameter. The interfacial thermal conductance of the Pt/GdIG and GdIG//GGG interfaces determined from the time-resolved diffraction study is of the same order of magnitude as previous reports for metal/oxide and epitaxial dielectric interfaces. The thermal parameters of the Pt/GdIG//GGG heterostructure will aid in the design and implementation of thermal transport devices and nanostructures.

36 MATERIALS SCIENCE↗