Search NASA⌕ Search

SEARCH · Search NASA

Results for “ablators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Incidence and Cause of Hypertension During Adrenal Radiofrequency Ablation

Purpose: To evaluate the incidence and cause of hypertension prospectively during adrenal radiofrequency ablation (RFA). Methods: For this study, approved by our institutional review board, written informed consent was obtained from all patients. Patients who received RFA for adrenal tumors (adrenal ablation) and other abdominal tumors (nonadrenal ablation) were included in this prospective study. Blood pressure was monitored during RFA. Serum adrenal hormone levels including epinephrine, norepinephrine, dopamine, and cortisol levels were measured before and during RFA. The respective incidences of procedural hypertension (systolic blood pressure >200 mmHg) of the two patient groups were compared. Factors correlating with procedural systolic blood pressure were evaluated by regression analysis.ResultsNine patients underwent adrenal RFA and another 9 patients liver (n = 5) and renal (n = 4) RFA. Asymptomatic procedural hypertension that returned to the baseline by injecting calcium blocker was found in 7 (38.9%) of 18 patients. The incidence of procedural hypertension was significantly higher in the adrenal ablation group (66.7%, 6/9) than in the nonadrenal ablation group (11.1%, 1/9, P < 0.0498). Procedural systolic blood pressure was significantly correlated with serum epinephrine (R{sup 2} = 0.68, P < 0.0001) and norepinephrine (R{sup 2} = 0.72, P < 0.0001) levels during RFA. The other adrenal hormones did not show correlation with procedural systolic blood pressure. Conclusion: Hypertension occurs frequently during adrenal RFA because of the release of catecholamine.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MR-guided Neurolytic Celiac Plexus Ablation: An Evaluation of Effect and Injection Spread Pattern in Cancer Patients with Celiac Tumor Infiltration

ObjectiveThe purpose of this study was to evaluate the feasibility, the initial accuracy, and the effects of the MR-guided neurolytic celiac plexus ablation as a method to treat cancer-induced chronic abdominal pain. Thirteen celiac plexus ablations were performed for 12 patients. A 0.23-T open MRI scanner with optical navigation was used for procedural guidance. As an adjunct to the MR-guided needle positioning, the needle location was confirmed with saline injection and consequent MR imaging (STIR sequence). The spread of the ablative injection material (alcohol-lidocaine mix) was observed by repeating this sequence after the therapeutic injection. Pain scores from seven patients (eight ablations) were used to assess the therapy effect. MR guidance allowed adequate needle positioning and visualization of injection material in all cases. The rest pain scores significantly decreased from 4 (median) at baseline to 1 (median) at 2 weeks (p < 0.05). Average and worst pain experienced during the past week were significantly lower at the 2-week time point compared with the baseline (p < 0.05). However, the intervention did not result in reduction of opioid use at 2 weeks.MR guidance is an accurate and safe method for celiac plexus ablation with positive therapeutic effect.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MR-Guided High-Intensity Focused Ultrasound Ablation of Breast Cancer with a Dedicated Breast Platform

Optimizing the treatment of breast cancer remains a major topic of interest. In current clinical practice, breast-conserving therapy is the standard of care for patients with localized breast cancer. Technological developments have fueled interest in less invasive breast cancer treatment. Magnetic resonance-guided high-intensity focused ultrasound (MR-HIFU) is a completely noninvasive ablation technique. Focused beams of ultrasound are used for ablation of the target lesion without disrupting the skin and subcutaneous tissues in the beam path. MRI is an excellent imaging method for tumor targeting, treatment monitoring, and evaluation of treatment results. The combination of HIFU and MR imaging offers an opportunity for image-guided ablation of breast cancer. Previous studies of MR-HIFU in breast cancer patients reported a limited efficacy, which hampered the clinical translation of this technique. These prior studies were performed without an MR-HIFU system specifically developed for breast cancer treatment. In this article, a novel and dedicated MR-HIFU breast platform is presented. This system has been designed for safe and effective MR-HIFU ablation of breast cancer. Furthermore, both clinical and technical challenges are discussed, which have to be solved before MR-HIFU ablation of breast cancer can be implemented in routine clinical practice.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Haemorrhagic Complications and Symptomatic Venous Thromboembolism in Interventional Tumour Ablations: The Impact of Peri-interventional Thrombosis Prophylaxis

AimThe aim of this study was to assess the rates of haemorrhagic and thrombotic complications in patients undergoing interventional tumour ablation with and without peri-interventional low-molecular-weight heparin (LMWH) thrombosis prophylaxis.MethodsPatients presented with primary and secondary neoplastic lesions in the liver, lung, kidney, lymph nodes and other locations. A total of 781 tumour ablations (radiofrequency ablation, n = 112; interstitial brachytherapy, n = 669) were performed in 446 patients over 22 months; 260 were conducted under peri-interventional thrombosis prophylaxis with LMWH (H-group;) and 521 without this (NH-group, in 143 of these, LMWH was given post-interventionally).ResultsSixty-three bleeding events occurred. There were significantly more bleedings in the H-group than in the NH-group (all interventions, 11.66 and 6.26 %, p = 0.0127; liver ablations, 12.73 and 7.1 %, p = 0.0416). The rate of bleeding events Grade ≥ III in all procedures was greater by a factor of >2.6 in the H-group than in the NH-group (4.64 and 1.73 %, p = 0.0243). In liver tumour ablations, the corresponding factor was about 3.3 (5.23 and 1.54 %, p = 0.028). In uni- and multivariate analyses including covariates, the only factor constantly and significantly associated with the rate of haemorrhage events was peri-interventional LMWH prophylaxis. Only one symptomatic lung embolism occurred in the entire cohort (NH-group). The 30- and 90-day mortalities were significantly greater in the H-group than in the NH-group.ConclusionsPeri-interventional LMWH thrombosis prophylaxis should be considered with caution. The rate of clinically relevant thrombotic events was extremely low.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Laser Guidance in C-Arm Cone-Beam CT-Guided Radiofrequency Ablation of Osteoid Osteoma Reduces Fluoroscopy Time

PurposeTo assess whether laser guidance can reduce fluoroscopy and procedure time of cone-beam computed tomography (CBCT)-guided radiofrequency (RF) ablations of osteoid osteoma compared to freehand CBCT guidance.Materials and Methods32 RF ablations were retrospectively analyzed, 17 laser-guided and 15 procedures using the freehand technique. Subgroup selection of 18 ablations in the hip–pelvic region with a similar degree of difficulty was used for a direct comparison. Data are presented as median (ranges).ResultsComparison of all 32 ablations resulted in fluoroscopy times of 365 s (193–878 s) for freehand and 186 s (75–587 s) for laser-guided procedures (p = 0.004). Corresponding procedure times were 56 min (35–97 min) and 52 min (30–85 min) (p = 0.355). The subgroup showed comparable target sizes, needle path lengths, and number of scans between groups. Fluoroscopy times were lower for laser-guided procedures, 215 s (75–413 s), compared to 384 s (193–878 s) for freehand (p = 0.012). Procedure times were comparable between groups, 51 min (30–72 min) for laser guidance and 58 min (35–79 min) for freehand (p = 0.172).ConclusionAdding laser guidance to CBCT-guided osteoid osteoma RF ablations significantly reduced fluoroscopy time without increasing procedure time.Level of EvidenceLevel 4, case series.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Hydrodissection of the Gallbladder Bed: A Technique for Ablations Located Close to the Gallbladder

Objective: To report the technique of hydrodissection of the gallbladder bed, in order to separate the gallbladder wall from the liver surface during microwave ablation of liver malignancies located in segment V. Materials and Methods: Between January 2018 and March 2018, percutaneous hydrodissection of the gallbladder fossa was performed during four microwave ablation procedures in three patients (One patient was treated twice for the same lesion, making a total of four procedures for three lesions.) All treated lesions were located in segment V and abutting the gallbladder. Number of hydrodissection needles, volume of hydrodissection, repartition of hydrodissection, separation of tumour from the gallbladder post-hydrodissection, technical success of hydrodissection/ablation, and complications were recorded and evaluated. Results: Hydrodissection of the gallbladder fossa was technically feasible in all four procedures, and microwave ablation was performed at maximum power without any early interruption. Time to perform hydrodissection was 11.3 min on average (range 7–18 min). Minimal distance between the ablation area and the GB increased from virtual to 10 mm on average (range 6–13), with a mean volume of dissection of 65 ml (range 40–100). Technical success was 75%. There was no complication related to the hydrodissection itself, and no acute or delayed gallbladder complication. Conclusion: Hydrodissection of the gallbladder bed is a feasible technique to separate the gallbladder from the liver surface. This could potentially decrease the risk of thermal injuries to the gallbladder wall when ablating tumours located in segment V.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of Internal Energy Distributions of Ions Created by Electrospray Ionization and Laser Ablation-Liquid Vortex Capture-Electrospray Ionization

Recently a number of techniques have combined laser ablation with liquid capture for mass spectrometry spot sampling and imaging applications. The newly developed non-contact liquid-vortex capture probe has been used to efficiently collect 355 nm UV laser ablated material in a continuous flow solvent stream in which the captured material dissolves and then undergoes electrospray ionization. This sampling and ionization approach has produced what appear to be classic electrospray ionization spectra; however, the softness of this sampling/ionization process versus simple electrospray ionization has not been definitely determined. A series of benzlypyridinium salts, known as thermometer ions, were used to compare internal energy distributions between electrospray ionization and the UV laser ablation liquid-vortex capture probe electrospray combination. Measured internal energy distributions were identical between the two techniques, even with differences in laser fluence (0.7-3.1 J cm-2) and when using UV-absorbing or non-UV-absorbing sample substrates. This data indicates ions formed directly by UV laser ablation, if any, are likely an extremely small constituent of the total ion signal observed. Instead, neutral molecules, clusters or particulates ejected from the surface during laser ablation, subsequently captured and dissolved in the flowing solvent stream then electrosprayed are the predominant source of ion signal observed. The electrospray ionization process used controls the softness of the technique.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Simple Method for Improving the Spatial Resolution in Infrared Laser Ablation Mass Spectrometry Imaging

In mass spectrometry imaging of tissues, the size of structures that can be distinguished is determined by the spatial resolution of the imaging technique. Here, the spatial resolution of IR laser ablation is markedly improved by increasing the distance between the laser and the focusing lens. As the distance between the laser and the lens is increased from 1 to 18 m, the ablation spot size decreases from 440 to 44 μm. This way, only the collimated center of the divergent laser beam is directed on the focusing lens, which results in better focusing of the beam. Part of the laser energy is lost at longer distance, but this is compensated by focusing of the radiation to a smaller area on the sample surface. The long distance can also be achieved by a set of mirrors, between which the radiation travels before it is directed to the focusing lens and the sample. This method for improving the spatial resolution can be utilized in mass spectrometry imaging of tissues by techniques that utilize IR laser ablation, such as laser ablation electrospray ionization, laser ablation atmospheric pressure photoionization, and matrix-assisted laser desorption electrospray ionization. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Interfacial engineering via laser ablation for high-performing PEM water electrolysis

A rationalized interfacial design strategy was applied to tailor the porous transport layer (PTL)-catalyst layer (CL) contact and the PTL bulk-phase architecture. Particularly, at the PTL-CL interface, our results reveal that laser ablated sintered titanium power-based PTLs improve electrolyzer performance at both the H2NEW Consortium baseline catalyst loading of 0.4 mgIr cm -2 as well as at the ultra-low catalyst loading of 0.055 mgIr cm -2 . Under ultra-low catalyst loadings, the laser ablated PTL demonstrates maximum reduction of 230 mV compared to the commercial PTL at 4 A cm -2 , and reduces by 68 mV at 3.2 A cm -2 under H2NEW baseline loading. Laser ablation alters the titanium phase at the interface, so it forms more uniform structure like a microporous layer or a backing layer, leading to an increase in the surface area in contact with the catalyst layer while preventing the membrane from deforming into the PTL. Moreover, we reveal that bulk-phase architecture modification of the PTL by ablating patterned pores at the flow field-PTL interface improves mass transport without sacrificing contact at the CL-PTL interface. Overall, laser ablation of the PTL is an effective method to customize interfacial design to enhance proton exchange membrane electrolyzer performance.

08 HYDROGEN↗

Comparison of ablators for the polar direct drive exploding pusher platform

In this work, we examine the performance of pure boron, boron carbide, high density carbon, and boron nitride ablators in the polar direct drive exploding pusher (PDXP) platform. The platform uses the polar direct drive configuration at the National Ignition Facility to drive high ion temperatures in a room temperature capsule and has potential applications for plasma physics studies and as a neutron source. The higher tensile strength of these materials compared to plastic enables a thinner ablator to support higher gas pressures, which could help optimize its performance for plasma physics experiments, while ablators containing boron enable the possibility of collecting additional data to constrain models of the platform. Applying recently developed and experimentally validated equation of state models for the boron materials, we examine the performance of these materials as ablators in 2D simulations, with particular focus on changes to the ablator and gas areal density, as well as the predicted symmetry of the inherently 2D implosion.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nanostructured Al{sub 2}O{sub 3}-TiO{sub 2} coatings for high-temperature protection of titanium alloy during ablation

Plasma-sprayed nanostructured Al{sub 2}O{sub 3}-13 wt.%TiO{sub 2} coatings were successfully fabricated on titanium alloys (Ti-6Al-4V) using as-prepared feedstock. Ablation experiments for the titanium alloy samples with or without a coating were carried out using a Metco 9MB plasma gun. The microstructure, phase constituents and mechanical properties of the titanium alloys before and after ablation were investigated by scanning electron microscope (SEM), X-ray diffractometer (XRD) and Vickers hardness tester. The surface morphologies, cross-sectional microstructure and hardness of titanium alloys with coatings are similar before and after ablation. In contrast, the microstructure and mechanical properties of the titanium alloy without coating are significantly changed after ablation. The surface coating is found to serve as a protective coating during ablation.

36 MATERIALS SCIENCE↗

Unraveling Spatio-Temporal Chemistry Evolution in Laser Ablation Plumes and Its Relation to Initial Plasma Conditions

The chemistry evolution in a laser ablation plume depends strongly on its initial physical conditions. In this article, we investigate the impact of plasma generation conditions on the interrelated phenomena of expansion dynamics, plasma chemistry, and physical conditions. Plasmas are produced from a uranium metal target in air using nanosecond, femtosecond, and femtosecond filament-assisted laser ablation. Time-resolved two-dimensional spectral imaging was performed for evaluating the spatio-temporal evolu-tion of atoms, diatoms, polyatomic molecules, and nanoparticles in situ. Emission spectral features reveal that molecular formation occurs at early times in both femtosecond and filament ablation plumes, although with different temporal decay. In contrast, mo-lecular formation is found to occur at much later times in nanosecond plasma evolution. Spectral modeling is used to infer tem-poral behavior of plasma excitation temperature, and results highlighted that nanosecond plume temperatures decay rapidly while plumes generated by filament ablation show slowest decay. In this work, we find U atoms and UO molecules co-exist in ultrafast laser produced plasmas even at early times after plasma onset owing to favorable temperatures for molecular formation. Regardless of irradiation conditions, plume emission features showed presence of higher oxides (i.e. UxOy), although with different temporal histories. Our study provides insight into the impact of plasma generation conditions on chemistry evolution in plasmas produced from traditional focused femtosecond, nanosecond, and filament-assisted laser ablation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effects of the absorption coefficient on resonant infrared laser ablation of poly(ethylene glycol)

We describe experiments on resonant infrared laser ablation of poly(ethylene glycol) (PEG) at two different resonant excitation wavelengths and for different molecular weights of PEG. The two resonant wavelengths correspond to different stretching vibrations of the polymer and have absorption coefficients that differ by roughly an order of magnitude. Ablation via excitation of the O-H terminal group stretching mode at 2.94 {mu}m, the weaker of the two absorptions, is delayed in time by several microseconds with respect to ablation at 3.47 {mu}m, the more strongly absorbing C-H stretching mode of the polymer. Time-resolved plume shadowgraphs along with ablation rate measurements for the two modes reveal that the absorption coefficient strongly affects the physical characteristics of the ejecta and plume, as well as the time scale for material removal. Temperature-rise calculations demonstrate that phase explosion is likely the operative mechanism in ablation at the C-H mode, while normal boiling may play a role in material removal at the O-H mode.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Modifying Wire Array Z-pinch Ablation Structure and Implosion Dynamics Using Coiled Arrays

Coiled arrays, a cylindrical array in which each wire is formed into a helix, suppress the modulation of ablation at the fundamental wavelength. Outside the vicinity of the wire cores, ablation flow from coiled arrays is modulated at the coil wavelength and has a 2-stream structure in the r,{theta} plane. Within the vicinity of the helical wires, ablation is concentrated at positions with the greatest azimuthal displacement and plasma is axially transported from these positions such that the streams become aligned with sections of the coil furthest from the array axis. The GORGON MHD code accurately reproduces this observed ablation structure, which can be understood in terms of JxB forces that result from the interaction of the global magnetic field with a helical current path as well as additional current paths suggested by the simulations. With this ability to control where ablation streamers occur, large wavelength coils were constructed such that the breaks that form in the wires had sufficient axial separation to prevent perturbations in the implosion sheath from merging. This produces a new mode of implosion in which the global instability can be controlled and perturbations correlated between all wires in an array. For large wavelength 8-wire coiled arrays, this produced a dramatic increase in x-ray power, equalling that of a 32-wire straight array. These experiments were carried out on the MAGPIE generator (1 MA, 240 ns) at Imperial College, and the COBRA generator (1 MA, 100 ns) at Cornell University.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Transrectal Array Configurations Optimized For Prostate HIFU Ablation

The objectives of this study were to evaluate and compare steering and ablation rates from several types of transrectal arrays operated at different frequencies for whole prostate ablation. Three-dimensional acoustic and thermal modeling (Rayleigh-Sommerfield and Penne's BHTE) were performed. Treatment volumes up to 70cc and anterior-posterior distances up to 6 cm were considered. The maximum transducer dimensions were constrained to 5 cm (along rectum) and 2.5 cm (elevation), and the channel count was limited to 256. Planar array configurations for truncated-annular, 1/1.5D, and 2D random arrays were evaluated at 1, 2, and 4 MHz for capability to treat the entire prostate. The acoustic intensity at the surface was fixed at 10 W/cm{sup 2}. The maximum temperature was restricted to 80 deg. C. The volumetric ablation rate was computed to compare the treatment times amongst different configurations. The 1.5D Planar array at 1 MHz ablated the whole prostate in the shortest amount of time while maintaining adequate steering. The higher frequency arrays required smaller elevation apertures for a fixed channel count to maintain a single focal spot at the desired location. Consequently, these arrays resulted in slower heating rates with increased near-field heating. The 1 MHz 1.5D array would also be advantageous compared to single-element transducers since only one mechanical degree of motion is required. This study demonstrates the selection of an optimal array geometry and frequency for transrectal HIFU, resulting in faster ablation rates and reduced treatment times.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Laser ablation of aluminum from normal evaporation to phase explosion

A study of laser ablation of Aluminum sample by nanosecond laser pulses considering two simultaneous mechanisms of normal evaporation and phase explosion is theoretically carried out. The temperature distribution in the sample is calculated by a one dimensional heat conduction equation. Ablation depth due to the evaporation and explosion is calculated as a function of laser pulse energies. Variation in some effective sample parameters during the laser ablation and their effects on laser ablation mechanisms are taken into account. At low irradiance, ablation is mainly due to the evaporation, while after a threshold intensity, the phase explosion becomes the dominant mechanism. Theoretical results of transition from the normal evaporation to the phase explosion are in good agreement with the experimental results.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Charging and ExB rotation of ablation clouds surrounding refueling pellets in hot fusion plasmas

The finite resistivity magnetohydrodynamic code FRONTIER-MHD[R. Samulyak et al., Nucl. Fusion 47, 103 (2007)] is used to simulate the ablation rate of refueling pellets, including the novel effect of electrostatically induced ExB rotation of the ablation cloud about its symmetry axis parallel to the magnetic field. The key finding is that the centrifugal force of cloud rotation pushes the cloud density radially outwards, creating a more ''transparent'' ablation channel. With reduced shielding, the steady state ablation rate of a deuterium pellet significantly increases from {approx}35% to 100%, depending on the B-field strength. This new effect brings the ablation rate into better accord with a known theoretical scaling law, which agrees with most current experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Damage free laser ablation of SiO{sub 2} for local contact opening on silicon solar cells using an a-Si:H buffer layer

We have used a Q-switched Nd:YVO{sub 4}, diode pumped 532 nm laser with nanosecond pulses, and a spot diameter of 40 {mu}m to ablate a layer of plasma enhanced chemical vapor deposited (PECVD) SiO{sub 2} on n-type Cz silicon, with the aim of making local contact openings on back-junction silicon solar cells. Laser pulses within the ns range are usually believed to be incompatible with processing of high efficiency solar cells because such long pulses induce too much damage into the underlying silicon lattice. This is due to thermal dissipation. In this work, a PECVD layer of a-Si:H between the n-type silicon and the dielectric layer is shown to absorb much of the laser radiation and allows for ablation at laser fluences lower than the ablation threshold of crystalline silicon. In addition, the a-Si:H layer serves as an excellent surface passivation layer for the silicon substrate. We show that it is possible to ablate PECVD SiO{sub 2} in a damage free way with fluences five times lower than those needed to ablate crystalline Si. Our results are verified experimentally with high resolution transmission electron microscopy of the crystal structure in the laser irradiated areas, and quasi-steady-state photoconductance measurements of emitter saturation currents. In addition, we have simulated the energy transfer from a ns 532 nm Gaussian shaped laser beam to a SiO{sub 2} covered Si lattice with and without the a-Si:H buffer layer. A model that coincides very well with the experiments is found.

36 MATERIALS SCIENCE↗