Search NASA⌕ Search

SEARCH · Search NASA

Results for “absolute”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

First measurements of the absolute branching fraction of Λ c ( 2625 ) + → Λ c + π + π − and upper limit on Λ c ( 2595 ) + → Λ c + π + π −

The absolute branching fraction of the decay Λ c ( 2625 ) + → Λ c + π + π − is measured for the first time to be ( 50.2 ± 5.7 stat ± 3.5 syst ) % with 368.48 pb − 1 of e + e − collision data collected by the BESIII detector at the center-of-mass energies of s = 4.918 and 4.950 GeV. Although the central value of the result is lower than the theoretical prediction of 67%, obtained from isospin symmetry, they are consistent taking the uncertainties into account. This is the first absolute branching fraction measurement for Λ c ( 2625 ) + since it was found. This measurement is necessary to obtain the coupling constants for the transitions between s -wave and p -wave charmed baryons in heavy hadron chiral perturbation theory. In addition, we search for the decay Λ c ( 2595 ) + → Λ c + π + π − . No significant signal is observed, and the upper limit on its branching fraction is determined to be 85.0% at the 90% confidence level. Published by the American Physical Society 2024

Astronomy & Astrophysics↗

Absolute branching fraction measurements for exclusive D{sub s} semileptonic decays

We measure the absolute branching fractions of D{sub s} semileptonic decays where the hadron in the final state is one of {phi}, {eta}, {eta}{sup '}, K{sub S}{sup 0}, K*{sup 0}, and f{sub 0}, using 2.8x10{sup 5} e{sup +}e{sup -}{yields}D{sub s}D{sub s}* decays collected in the CLEO-c detector at a center-of-mass energy close to 4170 MeV. We obtain B(D{sub s}{sup +}{yields}{phi}e{sup +}{nu}{sub e})=(2.29{+-}0.37{+-}0.11)%, B(D{sub s}{sup +}{yields}{eta}e{sup +}{nu}{sub e})=(2.48{+-}0.29{+-}0.13)%, B(D{sub s}{sup +}{yields}{eta}{sup '}e{sup +}{nu}{sub e})=(0.91{+-}0.33{+-}0.05)%, where the first uncertainties are statistical and the second are systematic. We also obtain B(D{sub s}{sup +}{yields}K{sup 0}e{sup +}{nu}{sub e})=(0.37{+-}0.10{+-}0.02)%, and B(D{sub s}{sup +}{yields}K*{sup 0}e{sup +}{nu}{sub e})=(0.18{+-}0.07{+-}0.01)%, which are the first measurements of Cabibbo suppressed exclusive D{sub s} semileptonic decays, and, B(D{sub s}{sup +}{yields}f{sub 0}e{sup +}{nu}{sub e})xB(f{sub 0}{yields}{pi}{sup +}{pi}{sup -})=(0.13{+-}0.04{+-}0.01)%. This is the first absolute product branching fraction determination for a semileptonic decay including a scalar meson in the final state.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Exploring the Saturation Levels of Stimulated Raman Scattering in the Absolute Regime

This Letter reports new experimental results that evidence the transition between the absolute and convective growth of stimulated Raman scattering (SRS). Significant reflectivities were observed only when the instability grows in the absolute regime. In this case, saturation processes efficiently limit the SRS reflectivity that is shown to scale linearly with the laser intensity, and the electron density and temperature. Such a scaling agrees with the one established by T. Kolber et al.[Phys. Fluids B 5, 138 (1993)] and B Bezzerides et al.[Phys. Rev. Lett. 70, 2569 (1993)], from numerical simulations where the Raman saturation is due to the coupling of electron plasma waves with ion waves dynamics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Absolute Magnetometry with He3

We report development of a highly accurate (parts per billion) absolute magnetometer based on 3He NMR. Optical pumping polarizes the spins, long coherence times provide high sensitivity, and the 3He electron shell effectively isolates the nuclear spin providing accuracy limited only by corrections including materials, sample shape, and magnetization. Our magnetometer was used to confirm calibration, to 32 ppb, of the magnetic-field sensors used in recent measurements of the muon magnetic moment anomaly g-2, which differs from the standard model by 2.4 ppm. With independent determination of the magnetic moment of 3He, this work will lead the way to a new absolute magnetometry standard.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First measurements of the absolute neutron spectrum using the Magnetic Recoil Spectrometer (MRS) at OMEGA

A new type of neutron spectrometer, called a Magnetic Recoil Spectrometer (MRS), has been built and implemented at the OMEGA laser facility [T. R. Boehly. D. L. Brown, R. S. Craxton et al., Opt. Commun. 133, 495 (1997)] for absolute measurements of the neutron spectrum in the range 6 to 30 MeV, from which fuel areal density ({rho}R), ion temperature (T{sub i}) and yield (Y{sub n}) can be determined. The results from the first MRS measurements of the absolute neutron spectrum are presented. In addition, measuring {rho}R at the National Ignition Facility (NIF) [G.H. Miller, E.I. Moses and C.R. Wuest, Nucl. Fusion 44, S228 (2004)] will be essential for assessing implosion performance during all stages of development from surrogate implosions to cryogenic fizzles and ignited implosions. To accomplish this, we are also developing an MRS for the NIF. As much of the R&D and instrument optimization of the MRS at OMEGA is directly applicable to the MRS at the NIF, a description of the MRS design on the NIF is discussed as well.

42 ENGINEERING↗

Absolute measurement of vacuum ultraviolet photon flux in an inductively coupled plasma using a Au thin film

A new method for absolute measurement of the vacuum ultraviolet (VUV) photon flux at the edge of a plasma is described. The light produced by the plasma was allowed to strike a negatively biased, gold-coated copper substrate remote from the plasma. The resulting photoelectron emission current was measured, and the absolute photon flux was then found from the known photoelectron yield of Au. The method was used to quantify the amount of VUV light produced by an Ar/He inductively coupled plasma (ICP). Strong emissions at 104.82 and 106.67 nm, corresponding to the 1s 2 and 1s 4 resonant states of Ar, were observed. The maximum, integrated VUV photon flux measured at the remote location was 3.2 × 10 13 photons/cm 2 s. This was estimated to correspond to a flux of 5 × 10 15 photons/cm 2 s at the edge of the ICP, in the range of reported values under similar conditions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Absolute and relative dose measurements with Gafchromic trade mark sign EBT film for high energy electron beams with different doses per pulse

The authors have evaluated the accuracy, in absolute and relative dose measurements, of the Gafchromic trade mark sign EBT film in pulsed high-energy electron beams. Typically, the electron beams used in radiotherapy have a dose-per-pulse value of less than 0.1 mGy/pulse. However, very high dose-per-pulse electron beams are employed in certain linear accelerators dedicated to intraoperatory radiation therapy (IORT). In this study, the absorbed dose measurements with Gafchromic trade mark sign EBT in both low (less than 0.3 mGy per pulse) and high (30 and 70 mGy per pulse) dose-per-pulse electron beams were compared with ferrous sulfate chemical Fricke dosimetry (operated by the Italian Primary Standard Dosimetry Laboratory), a method independent of the dose per pulse. A summary of Gafchromic trade mark sign EBT in relative and absolute beam output determination is reported. This study demonstrates the independence of Gafchromic trade mark sign EBT absorption as a function of dose per pulse at different dose levels. A good agreement (within 3%) was found with Fricke dosimeters for plane-base IORT applicators. Comparison with a diode detector is presented for relative dose measurements, showing acceptable agreement both in the steep dose falloff zone and in the homogeneous dose region. This work also provides experimental values for recombination correction factor (K{sub sat}) of a Roos (plane parallel) ionization chamber calculated on the basis of theoretical models for charge recombination.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-85: Leave-One-Out Perturbation (LOOP) Fitting Algorithm for Absolute Dose Film Calibration

Purpose: To introduce an outliers-recognition fitting routine for film dosimetry. It cannot only be flexible with any linear and non-linear regression but also can provide information for the minimal number of sampling points, critical sampling distributions and evaluating analytical functions for absolute film-dose calibration. Methods: The technique, leave-one-out (LOO) cross validation, is often used for statistical analyses on model performance. We used LOO analyses with perturbed bootstrap fitting called leave-one-out perturbation (LOOP) for film-dose calibration . Given a threshold, the LOO process detects unfit points (“outliers”) compared to other cohorts, and a bootstrap fitting process follows to seek any possibilities of using perturbations for further improvement. After that outliers were reconfirmed by a traditional t-test statistics and eliminated, then another LOOP feedback resulted in the final. An over-sampled film-dose- calibration dataset was collected as a reference (dose range: 0-800cGy), and various simulated conditions for outliers and sampling distributions were derived from the reference. Comparisons over the various conditions were made, and the performance of fitting functions, polynomial and rational functions, were evaluated. Results: (1) LOOP can prove its sensitive outlier-recognition by its statistical correlation to an exceptional better goodness-of-fit as outliers being left-out. (2) With sufficient statistical information, the LOOP can correct outliers under some low-sampling conditions that other “robust fits”, e.g. Least Absolute Residuals, cannot. (3) Complete cross-validated analyses of LOOP indicate that the function of rational type demonstrates a much superior performance compared to the polynomial. Even with 5 data points including one outlier, using LOOP with rational function can restore more than a 95% value back to its reference values, while the polynomial fitting completely failed under the same conditions. Conclusion: LOOP can cooperate with any fitting routine functioning as a “robust fit”. In addition, it can be set as a benchmark for film-dose calibration fitting performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sci—Fri PM: Dosimetry — 03: Delta4 diode absolute dose response for large and small target volume IMRT QA

The goal of this project was to quantify the over-response/under-response of the Delta4 diodes for Helical Tomotherapy plans on extreme target volume sizes. A custom Delta4 phantom quarter with a hole to insert an ionisation chamber (IC) close to the center of the phantom have been used to acquire simultaneous IC and diodes absolute dose measurements. Eight plans for different target volumes were created from 20cm to 1cm diameter. Diodes dose measurements in the target were compared with IC measurement, to quantify absolute dose accuracy. IC measurements show a good agreement with planned dose (±2%). Diode measurements demonstrate a good agreement with IC for regular target size of 5 and 10cm (0 to 1%). For larger targets, an over-response is observed for FW 25mm and 10mm (2 to 3%). for small target of 1cm diameter, a major under-response is observed for FW 25mm and 10mm (−8 and −36%). The over-response could to be due to the extra amount of scattered radiation and the opposite for under-response. Although this scatter hypothesis still has to be proven, early testing demonstrates an over-response of 40%/20% of the central diodes compare to IC when an open helical rotational beam is delivered 75mm/25mm away from the center of the phantom. These results are in agreement with the real patient Delta4 DQA results at our center.

60 APPLIED LIFE SCIENCES↗

Sci-Sat AM: Radiation Dosimetry and Practical Therapy Solutions - 03: Energy dependence of a clinical probe-format calorimeter and its pertinence to absolute photon and electron beam dosimetry

Purpose: To evaluate the intrinsic and absorbed-dose energy dependence of a small-scale graphite calorimeter probe (GPC) developed for use as a routine clinical dosimeter. The influence of charge deposition on the response of the GPC was also assessed by performing absolute dosimetry in clinical linac-based electron beams. Methods: Intrinsic energy dependence was determined by performing constant-temperature calorimetry dose measurements in a water-equivalent solid phantom, under otherwise reference conditions, in five high-energy photon (63.5 < %dd(10){sub X} < 76.3), and five electron (2.3 cm < R{sub 50} < 8.3 cm) beams. Reference dosimetry was performed for all beams in question using an Exradin A19 ion chamber with a calibration traceable to national standards. The absorbed-dose component of the overall energy dependence was calculated using the EGSnrc egs-chamber user code. Results: A total of 72 measurements were performed with the GPC, resulting in a standard error on the mean absorbed dose of better than 0.3 % for all ten beams. For both the photon and electron beams, no statistically-significant energy dependence was observed experimentally. Peak-to-peak, variations in the relative response of the GPC across all beam qualities of a given radiation type were on the order of 1 %. No effects, either transient or permanent, were attributable to the charge deposited by the electron beams. Conclusions: The GPC’s apparent energy-independence, combined with its well-established linearity and dose rate independence, make it a potentially useful dosimetry system capable measuring photon and electron doses in absolute terms at the clinical level.

61 RADIATION PROTECTION AND DOSIMETRY↗

Measurements of the reactor neutron power in absolute units

The neutron power of the reactor of the Yenisei space nuclear power plant is measured in absolute units using the modernized method of correlation analysis during the ground-based tests of the Yenisei prototypes. Results of the experiments are given. The desired result is obtained in a series of experiments carried out at the stage of the plant preparation for tests. The acceptability of experimental data is confirmed by the results of measuring the reactor neutron power in absolute units at the nominal level by the thermal balance during the life cycle tests of the ground prototypes.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Measurement of the absolute branching fraction of the inclusive decay $\Lambda _c^+ \rightarrow K_S^0X$: (BESIII Collaboration)

We report the first measurement of the absolute branching fraction of the inclusive decay Λ c + → K S 0 X . The analysis is performed using an e + e - collision data sample corresponding to an integrated luminosity of 567 pb - 1 taken at s = 4.6 GeV with the BESIII detector. Using eleven Cabibbo-favored Λ ¯ c - decay modes and the double-tag technique, this absolute branching fraction is measured to be B ( Λ c + → K S 0 X ) = ( 9.9 ± 0.6 ± 0.4 ) % , where the first uncertainty is statistical and the second systematic. The relative deviation between the branching fractions for the inclusive decay and the observed exclusive decays is ( 18.7 ± 8.3 ) % , which indicates that there may be some unobserved decay modes with a neutron or excited baryons in the final state.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The absolute path command

The ap command traveres all symlinks in a given file, directory, or executable name to identify the final absolute path. It can print just the final path, each intermediate link along with the symlink chan, and the permissions and ownership of each directory component in the final path. It has functionality similar to "which", except that it shows the final path instead of the first path. It is also similar to "pwd", but it can provide the absolute path to a relative directory from the current working directory.

Moody, A.↗

Absolute phase-assisted three-dimensional data registration for a dual-camera structured light system

For a three-dimensional shape measurement system with a single projector and multiple cameras, registering patches from different cameras is crucial. Registration usually involves a complicated and time-consuming procedure. We propose a new method that can robustly match different patches via absolute phase without significantly increasing its cost. For y and z coordinates, the transformations from one camera to the other are approximated as third-order polynomial functions of the absolute phase. The x coordinates involve only translations and scalings. These functions are calibrated and only need to be determined once. Experiments demonstrated that the alignment error is within RMS 0.7 mm.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Absolute testing of the reference surface of a Fizeau interferometer through even/odd decompositions

Absolute testing of spherical surfaces is a technological necessity because of increased accuracy requirements. In a Fizeau setup, the main part of the interferometer deviations thereby comes from the reference surface. We demonstrate the validity of an absolute testing procedure for the reference surface that has been proposed earlier. The procedure relies on the decomposition of the surface deviations into odd and even parts and could be used in partially coherent illumination. The odd deviations are obtained from a basic and a 180 deg. -rotated position of an auxiliary sphere, and the even deviations can be measured with the help of a cat's eye position in double pass using an opaque half screen in the interferometer aperture.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Absolute Neutron Flux Measurements of a D-T Neutron Generator

Many applications in neutron experiments require the absolute determination of the neutron flux. For example, if the mass of special nuclear material (SNM) is to be determined accurately from a measurement then the number of neutron per sec per square centimeter may need to be known very well. This requires using a detector with a very well known efficiency over the neutron energy range of interest to measure this flux. In our case, to compare the Monte Carlo modeling predictions with actual measured data the absolute neutron generator emission rate must be determined. Below we discuss several techniques, their advantages and disadvantages.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Transportable absolute yields of underground nuclear explosions. Application to the North Korean nuclear tests

The method developed and presented here improves our nuclear explosion monitoring capability by providing a new independent and transportable method to determine the explosive yields of seismically recorded events associated with foreign weapons development. Here we report new independent absolute yield and depth of burial estimates of the North Korean nuclear tests which are commensurate with previously determined source parameters. The key advantage of this method over other methods which estimate absolute explosive yields is that this method does not require any a priori calibration, and can be immediately applied to any region of interest. This method uses the source information obtained from the spectral ratios of envelopes of measured seismic coda waves to invert for model-derived yield and depth of burial. The only requirements of this method are that the region of interest must contain several (> 3) seismic sources which have been well recorded (SNR > 2) by a set of shared stations. For regions with only a few events (~ 3) and/or extremely band-limited observations for which the depth of burial is unknown, an earthquake with a known magnitude may be required to obtain an accurate and robust yield estimate.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

The Absolute Color Calibration of the Dark Energy Survey: A Spectrophotometric Sample of DA White Dwarfs in the Southern Sky

The Dark Energy Survey (DES), which is nearing the completion of the analysis of its full data set, is an imaging survey of one-quarter of the Southern sky down to an apparent magnitude of $i\sim24.5$. The survey observations were conducted between 2013 and 2019 with a 3-square-degree wide-field CCD mosaic camera (the Dark Energy Camera, or DECam) on the Blanco 4-meter telescope at the Cerro Tololo Interamerican Observatory in the Chilean Andes. The primary scientific goal of the DES was to measure properties of Dark Energy. In order to achieve its science goals, the DES had tight requirements on both its relative and absolute photometric calibrations. In this poster, we describe the sample of pure-hydrogen-atmosphere (“DA”) white dwarfs which were instrumental in working to establish the requirement on the absolute color calibration -- i.e., the calibration across the filter bands -- of the DES.

79 ASTRONOMY AND ASTROPHYSICS↗