SEARCH · Search NASA
Results for “acquisition validation”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Bioluminescence Tomography–Guided Radiation Therapy for Preclinical Research
Purpose: In preclinical radiation research, it is challenging to localize soft tissue targets based on cone beam computed tomography (CBCT) guidance. As a more effective method to localize soft tissue targets, we developed an online bioluminescence tomography (BLT) system for small-animal radiation research platform (SARRP). We demonstrated BLT-guided radiation therapy and validated targeting accuracy based on a newly developed reconstruction algorithm. Methods and Materials: The BLT system was designed to dock with the SARRP for image acquisition and to be detached before radiation delivery. A 3-mirror system was devised to reflect the bioluminescence emitted from the subject to a stationary charge-coupled device (CCD) camera. Multispectral BLT and the incomplete variables truncated conjugate gradient method with a permissible region shrinking strategy were used as the optimization scheme to reconstruct bioluminescent source distributions. To validate BLT targeting accuracy, a small cylindrical light source with high CBCT contrast was placed in a phantom and also in the abdomen of a mouse carcass. The center of mass (CoM) of the source was recovered from BLT and used to guide radiation delivery. The accuracy of the BLT-guided targeting was validated with films and compared with the CBCT-guided delivery. In vivo experiments were conducted to demonstrate BLT localization capability for various source geometries. Results: Online BLT was able to recover the CoM of the embedded light source with an average accuracy of 1 mm compared to that with CBCT localization. Differences between BLT- and CBCT-guided irradiation shown on the films were consistent with the source localization revealed in the BLT and CBCT images. In vivo results demonstrated that our BLT system could potentially be applied for multiple targets and tumors. Conclusions: The online BLT/CBCT/SARRP system provides an effective solution for soft tissue targeting, particularly for small, nonpalpable, or orthotopic tumor models.
A novel digital pulse processing architecture for nuclear instrumentation
The field of nuclear instrumentation covers a wide range of applications, including counting, spectrometry, pulse shape discrimination and multi-channel coincidence. These applications are the topic of many researches, new algorithms and implementations are constantly proposed thanks to advances in digital signal processing. However, these improvements are not yet implemented in instrumentation devices. This is especially true for neutron-gamma discrimination applications which traditionally use charge comparison method while literature proposes other algorithms based on frequency domain or wavelet theory which show better performances. Another example is pileups which are generally rejected while pileup correction algorithms also exist. These processes are traditionally performed offline due to two issues. The first is the Poissonian characteristic of the signal, composed of random arrival pulses which requires to current architectures to work in data flow. The second is the real-time requirement, which implies losing pulses when the pulse rate is too high. Despite the possibility of treating the pulses independently from each other, current architectures paralyze the acquisition of the signal during the processing of a pulse. This loss is called dead-time. These two issues have led current architectures to use dedicated solutions based on re-configurable components like Field Programmable Gate Arrays (FPGAs) to overcome the need of performance necessary to deal with dead-time. However, dedicated hardware algorithm implementations on re-configurable technologies are complex and time-consuming. For all these reasons, a programmable Digital pulse Processing (DPP) architecture in a high level language such as Cor C++ which can reduce dead-time would be worthwhile for nuclear instrumentation. This would reduce prototyping and test duration by reducing the level of hardware expertise to implement new algorithms. However, today's programmable solutions do not meet the need of performance to operate online and not allow scaling with the increase in the number of measurement channel. That is why an innovative DPP architecture is proposed in this paper. This architecture is able to overcome dead-time while being programmable and is flexible with the number of measurement channel. Proposed architecture is based on an innovative execution model for pulse processing applications which can be summarized as follow. The signal is not composed of pulses only, consequently, pulses processing does not have to operate on the entire signal. Therefore, the first step of our proposal is pulse extraction by the use of dedicated components named pulse extractors. The triggering step can be achieved after the analog-to-digital conversion without any signal shaping or filtering stages. Pileup detection and accurate pulse time stamping are done at this stage. Any application downstream this step can work on adaptive variable-sized array of samples simplifying pulse processing methods. Then, once the data flow is broken, it is possible to distribute pulses on Functional Units (FUs) which perform processing. As the date of each pulse is known, they can be processed individually out-of-order to provide the results. To manage the pulses distribution, a scheduler and an interconnection network are used. pulses are distributed on the first FU which is not busy without congesting the interconnection network. For this reason, the process duration does not result anymore in dead-time if there are enough FUs. FUs are designed to be standalone and to comprises at least a programmable general purpose processor (ARM, Microblaze) allowing the implementation of complex algorithms without any modification of the hardware. An acquisition chain is composed of a succession of algorithms which lead to organize our FUs as a software macro-pipeline, A simple approach consists in assigning one algorithm per FU. Consequently, the global latency becomes the worst latency of algorithms execution on FU. Moreover, as algorithms are executed locally - i.e. on a FU - this approach limits shared memory requirement. To handle multichannel, we propose FUs sharing, this approach maximize the chance to find a non-busy FU to process an incoming pulse. This is possible since each channel receive random event independently, the pulse extractors associated to them do not necessarily need to access simultaneously to all Computing resources at the same time to distribute their pulses. The major contribution of this paper is the proposition of an execution model and its associated hardware programmable architecture for digital pulse processing that can handle multiple acquisition channels while maintaining the scalability thanks to the use of shared resources. This execution model and associated architecture are validated by simulation of a cycle accurate architecture SystemC model. Proposed architecture shows promising results in terms of scalability while maintaining zero dead-time. This work also permit the sizing of hardware resources requirement required for a predefined set of applications. Future work will focus on the interconnection network and a scheduling policy that can exploit the variable-length of pulses. Then, the hardware implementation of this architecture will be performed and tested for a representative set of application.
Intelligent Computer Vision System for Automated Classification
In this paper we investigate an Intelligent Computer Vision System applied for recognition and classification of commercially available cork tiles. The system is capable of acquiring and processing gray images using several feature generation and analysis techniques. Its functionality includes image acquisition, feature extraction and preprocessing, and feature classification with neural networks (NN). We also discuss system test and validation results from the recognition and classification tasks. The system investigation also includes statistical feature processing (features number and dimensionality reduction techniques) and classifier design (NN architecture, target coding, learning complexity and performance, and training with our own metaheuristic optimization method). The NNs trained with our genetic low-discrepancy search method (GLPtauS) for global optimisation demonstrated very good generalisation abilities. In our view, the reported testing success rate of up to 95% is due to several factors: combination of feature generation techniques; application of Analysis of Variance (ANOVA) and Principal Component Analysis (PCA), which appeared to be very efficient for preprocessing the data; and use of suitable NN design and learning method.
Superheterodyne configuration for two-wavelength interferometry applied to absolute distance measurement
We present a new superheterodyne technique for long-distance measurements by two-wavelength interferometry (TWI). While conventional systems use two acousto-optic modulators to generate two different heterodyne frequencies, here the two frequencies result from synchronized sweeps of optical and radio frequencies. A distributed feedback laser source is injected in an intensity modulator that is driven at the half-wave voltage mode. A radio-frequency signal is applied to this intensity modulator to generate two optical sidebands around the optical carrier. This applied radio frequency consists of a digital ramp between 13 and 15 GHz, with 1 ms duration and with an accuracy of better than 1 ppm. Simultaneously, the laser source is frequency modulated by a current modulation that is synchronized on the radio-frequency ramp as well as on a triangle waveform. These two frequency-swept optical signals at the output of the modulator illuminate a Michelson interferometer and create two distinct distance-dependent heterodyne frequencies on the photodetector. The superheterodyne signal is then detected and bandpass filtered to retrieve the absolute distance measurement. Experiments between 1 and 15 m confirm the validity of this new concept, leading to a distance accuracy of {+-} 50 {mu}m for a 1 ms acquisition time.
New Ways of Facilitating Improved Data Discovery and Access for NASA's Suborbital Earth Science Observations
NASA conducts field research in various Earth Science disciplines utilizing airborne and other non-satellite platforms to acquire in situ and remotely sensed observations indicative of physical processes across a range of scales. Field efforts are key in the development and validation of instruments and satellite algorithm refinements. The heterogeneous data, with a range of file formats, scales, and acquisition methods, support research in several science areas. NASA’s archive process assigns data products to discipline-oriented Distributed Active Archive Centers (DAACs) for stewardship. Over time, individual DAACs have developed tools for data browsing and serving disparate user bases. As science becomes more interdisciplinary, researchers need to incorporate observations from multiple campaigns, and multiple DAACs, into their work. Motivated in part by this shifting paradigm of needs, the Catalog of Archived Suborbital Earth Science Investigations (CASEI) was created. CASEI provides a single starting point to browse, search, and discover airborne and field data. Contextual metadata are organized and inter-linked allowing intuitive, integrated exploration across all NASA DAACs. Campaign science objectives, platform and instrument configurations, geographical details, geophysical concepts, and more are tracked in CASEI’s database, facilitating multi-parameter search, browse, and discovery of relevant data products. Researchers are able to directly access associated data products, via DOI links, regardless of the DAAC where they reside. Significant events, key time periods of high science interest within the longer-duration campaign effort, are also indicated and allow for a more efficient identification of critical data subsets. This presentation describes CASEI’s development, intensive metadata curation process, and demonstrates the web interface experience. Initial content metrics and plans for continued maintenance will also be discussed.
AMS Ground Truth Measurements: Calibrations and Test Lines
Airborne gamma spectrometry is one of the primary techniques used to define the extent of ground contamination after a radiological incident. Its usefulness was demonstrated extensively during the response to the Fukushima NPP accident in March-May 2011. To map ground contamination, a set of scintillation detectors is mounted on an airborne platform (airplane or helicopter) and flown over contaminated areas. The acquisition system collects spectral information together with the aircraft position and altitude every second. To provide useful information to decision makers, the count data, expressed in counts per second (cps), need to be converted to a terrestrial component of the exposure rate at 1 meter (m) above ground, or surface activity of the isotopes of concern. This is done using conversion coefficients derived from calibration flights. During a large-scale radiological event, multiple flights may be necessary and may require use of assets from different agencies. However, because production of a single, consistent map product depicting the ground contamination is the primary goal, it is critical to establish a common calibration line very early into the event. Such a line should be flown periodically in order to normalize data collected from different aerial acquisition systems and that are potentially flown at different flight altitudes and speeds. In order to verify and validate individual aerial systems, the calibration line needs to be characterized in terms of ground truth measurements This is especially important if the contamination is due to short-lived radionuclides. The process of establishing such a line, as well as necessary ground truth measurements, is described in this document.
Using deep RNA sequencing for the structural annotation of the laccaria bicolor mycorrhizal transcriptome.
Accurate structural annotation is important for prediction of function and required for in vitro approaches to characterize or validate the gene expression products. Despite significant efforts in the field, determination of the gene structure from genomic data alone is a challenging and inaccurate process. The ease of acquisition of transcriptomic sequence provides a direct route to identify expressed sequences and determine the correct gene structure. We developed methods to utilize RNA-seq data to correct errors in the structural annotation and extend the boundaries of current gene models using assembly approaches. The methods were validated with a transcriptomic data set derived from the fungus Laccaria bicolor, which develops a mycorrhizal symbiotic association with the roots of many tree species. Our analysis focused on the subset of 1501 gene models that are differentially expressed in the free living vs. mycorrhizal transcriptome and are expected to be important elements related to carbon metabolism, membrane permeability and transport, and intracellular signaling. Of the set of 1501 gene models, 1439 (96%) successfully generated modified gene models in which all error flags were successfully resolved and the sequences aligned to the genomic sequence. The remaining 4% (62 gene models) either had deviations from transcriptomic data that could not be spanned or generated sequence that did not align to genomic sequence. The outcome of this process is a set of high confidence gene models that can be reliably used for experimental characterization of protein function. 69% of expressed mycorrhizal JGI 'best' gene models deviated from the transcript sequence derived by this method. The transcriptomic sequence enabled correction of a majority of the structural inconsistencies and resulted in a set of validated models for 96% of the mycorrhizal genes. The method described here can be applied to improve gene structural annotation in other species, provided that there is a sequenced genome and a set of gene models.
BrachyView, a novel in-body imaging system for HDR prostate brachytherapy: Experimental evaluation
Purpose: This paper presents initial experimental results from a prototype of high dose rate (HDR) BrachyView, a novel in-body source tracking system for HDR brachytherapy based on a multipinhole tungsten collimator and a high resolution pixellated silicon detector array. The probe and its associated position estimation algorithms are validated and a comprehensive evaluation of the accuracy of its position estimation capabilities is presented. Methods: The HDR brachytherapy source is moved through a sequence of positions in a prostate phantom, for various displacements in x, y, and z. For each position, multiple image acquisitions are performed, and source positions are reconstructed. Error estimates in each dimension are calculated at each source position and combined to calculate overall positioning errors. Gafchromic film is used to validate the accuracy of source placement within the phantom. Results: More than 90% of evaluated source positions were estimated with an error of less than one millimeter, with the worst-case error being 1.3 mm. Experimental results were in close agreement with previously published Monte Carlo simulation results. Conclusions: The prototype of HDR BrachyView demonstrates a satisfactory level of accuracy in its source position estimation, and additional improvements are achievable with further refinement of HDR BrachyView’s image processing algorithms.
A micron resolution optical scanner for characterization of silicon detectors
The emergence of high position resolution (∼10 μm) silicon detectors in recent times have highlighted the urgent need for the development of new automated optical scanners of micron level resolution suited for characterizing microscopic features of these detectors. More specifically, for the newly developed silicon photo-multipliers (SiPM) that are compact, possessing excellent photon detection efficiency with gain comparable to photo-multiplier tube. In a short time, since their invention the SiPMs are already being widely used in several high-energy physics and astrophysics experiments as the photon readout element. The SiPM is a high quantum efficiency, multi-pixel photon counting detector with fast timing and high gain. The presence of a wide variety of photo sensitive silicon detectors with high spatial resolution requires their performance evaluation to be carried out by photon beams of very compact spot size. We have designed a high resolution optical scanner that provides a monochromatic focused beam on a target plane. The transverse size of the beam was measured by the knife-edge method to be 1.7 μm at 1 − σ level. Since the beam size was an order of magnitude smaller than the typical feature size of silicon detectors, this optical scanner can be used for selective excitation of these detectors. The design and operational details of the optical scanner, high precision programmed movement of target plane (0.1 μm) integrated with general purpose data acquisition system developed for recording static and transient response photo sensitive silicon detector are reported in this paper. Entire functionality of scanner is validated by using it for selective excitation of individual pixels in a SiPM and identifying response of active and dead regions within SiPM. Results from these studies are presented in this paper.
Acquisition of a Biomedical Database of Acute Responses to Space Flight during Commercial Personal Suborbital Flights
There is currently too little reproducible data for a scientifically valid understanding of the initial responses of a diverse human population to weightlessness and other space flight factors. Astronauts on orbital space flights to date have been extremely healthy and fit, unlike the general human population. Data collection opportunities during the earliest phases of space flights to date, when the most dynamic responses may occur in response to abrupt transitions in acceleration loads, have been limited by operational restrictions on our ability to encumber the astronauts with even minimal monitoring instrumentation. The era of commercial personal suborbital space flights promises the availability of a large (perhaps hundreds per year), diverse population of potential participants with a vested interest in their own responses to space flight factors, and a number of flight providers interested in documenting and demonstrating the attractiveness and safety of the experience they are offering. Voluntary participation by even a fraction of the flying population in a uniform set of unobtrusive biomedical data collections would provide a database enabling statistical analyses of a variety of acute responses to a standardized space flight environment. This will benefit both the space life sciences discipline and the general state of human knowledge.
An intelligent data acquisition system for fluid mechanics research
This paper describes a novel data acquisition system for use with wind-tunnel probe-based measurements, which incorporates a degree of specific fluid dynamics knowledge into a simple expert system-like control program. The concept was developed with a rudimentary expert system coupled to a probe positioning mechanism operating in a small-scale research wind tunnel. The software consisted of two basic elements, a general-purpose data acquisition system and the rulebased control element to take and analyze data and supplying decisions as to where to measure, how many data points to take, and when to stop. The system was validated in an experiment involving a vortical flow field, showing that it was possible to increase the resolution of the experiment or, alternatively, reduce the total number of data points required, to achieve parity with the results of most conventional data acquisition approaches.
Superficial dosimetry imaging based on Čerenkov emission for external beam radiotherapy with megavoltage x-ray beam
Purpose: Čerenkov radiation emission occurs in all tissue, when charged particles (either primary or secondary) travel at velocity above the threshold for the Čerenkov effect (about 220 KeV in tissue for electrons). This study presents the first examination of optical Čerenkov emission as a surrogate for the absorbed superficial dose for MV x-ray beams.Methods: In this study, Monte Carlo simulations of flat and curved surfaces were studied to analyze the energy spectra of charged particles produced in different regions near the surfaces when irradiated by MV x-ray beams. Čerenkov emission intensity and radiation dose were directly simulated in voxelized flat and cylindrical phantoms. The sampling region of superficial dosimetry based on Čerenkov radiation was simulated in layered skin models. Angular distributions of optical emission from the surfaces were investigated. Tissue mimicking phantoms with flat and curved surfaces were imaged with a time domain gating system. The beam field sizes (50 × 50–200 × 200 mm{sup 2}), incident angles (0°–70°) and imaging regions were all varied.Results: The entrance or exit region of the tissue has nearly homogeneous energy spectra across the beam, such that their Čerenkov emission is proportional to dose. Directly simulated local intensity of Čerenkov and radiation dose in voxelized flat and cylindrical phantoms further validate that this signal is proportional to radiation dose with absolute average discrepancy within 2%, and the largest within 5% typically at the beam edges. The effective sampling depth could be tuned from near 0 up to 6 mm by spectral filtering. The angular profiles near the theoretical Lambertian emission distribution for a perfect diffusive medium, suggesting that angular correction of Čerenkov images may not be required even for curved surface. The acquisition speed and signal to noise ratio of the time domain gating system were investigated for different acquisition procedures, and the results show there is good potential for real-time superficial dose monitoring. Dose imaging under normal ambient room lighting was validated, using gated detection and a breast phantom.Conclusions: This study indicates that Čerenkov emission imaging might provide a valuable way to superficial dosimetry imaging in real time for external beam radiotherapy with megavoltage x-ray beams.
An Overview of the Integrated Crate Interrogation System (ICIS) for use at the Savannah River Site
The Integrated Crate Interrogation System (ICIS) was developed for use at the Savannah River Site to assay transuranic waste in large containers. The system comprises a Box Segmented Gamma Scanner (BSGS) providing high resolution gamma spectroscopy, and a Box Neutron Assay System (BNAS) providing passive neutron counting capability. The multi-modality approach is taken where the assay results from the gamma and neutron systems are combined to complement each other in satisfying Waste Isolation Pilot Plant (WIPP) criteria. This paper gives an overview of the system that has been built, factory calibrated, and delivered to the site. The BSGS is similar to a standard Canberra Segmented Gamma Box Counter, but with the addition of a transmission option for ascertaining density and rudimentary fill-height information. This supplements the Multi-Curve approach based on efficiency in energy and density. The BSGS has a moving trolley which travels on rails through a passive emission counting station using large BEGe detectors, and a transmission counting station using NaI detectors in conjunction with high- and low-beam transmission stages. The assay result provides information on the Pu, Am and/or U isotopic ratios using standard isotopic analysis codes, quantitative measurement of Pu and U for low and medium density matrices, and direct measurement of other gamma emitters in the waste that are not identified in the isotopic measurement. It also provides basic positional information to improve the accuracy of both the gamma and the neutron measurement. The BNAS is a passive neutron coincidence counter intended for use with multiplicity counting of items of various geometries. The counter utilizes 320 {sup 3}He filled proportional counters arranged in a 4 {pi} geometry about the assay cavity and divided into 80 counting channels. The assay result provides the {sup 240}Pu-effective mass with which the gamma isotopic measurement is combined to provide reliable reporting of Pu and other isotopes. It also provides the total alpha activity that must be reported as part of the characterization requirements for WIPP (or bounds on the alpha activity based on the chemical form of the alpha-emitter). The neutron assay also complements the gamma results where matrix effects, self shielding or self absorption effects, and the presence of high-Z material, severely limits accuracy. Matrix moderator corrections for the neutron assay are based on a multi-position Add-A-Source correction augmented by a Modified Hydrogen Correction. The data acquisition also incorporates a Local Coincidence Veto circuit. Following the calibration of the system at the factory, confirmatory measurements were performed to demonstrate the validity of the calibrations, and to verify that the measurement system meets the Waste Acceptance Criteria established by DOE/WIPP. (authors)
Experimental validation of a method characterizing bow tie filters in CT scanners using a real-time dose probe
Purpose: Beam-shaping or ''bow tie'' (BT) filters are used to spatially modulate the x-ray beam in a CT scanner, but the conventional method of step-and-shoot measurement to characterize a beam's profile is tedious and time-consuming. The theory for characterization of bow tie relative attenuation (COBRA) method, which relies on a real-time dosimeter to address the issues of conventional measurement techniques, was previously demonstrated using computer simulations. In this study, the feasibility of the COBRA theory is further validated experimentally through the employment of a prototype real-time radiation meter and a known BT filter. Methods: The COBRA method consisted of four basic steps: (1) The probe was placed at the edge of a scanner's field of view; (2) a real-time signal train was collected as the scanner's gantry rotated with the x-ray beam on; (3) the signal train, without a BT filter, was modeled using peak values measured in the signal train of step 2; and (4) the relative attenuation of the BT filter was estimated from filtered and unfiltered data sets. The prototype probe was first verified to have an isotropic and linear response to incident x-rays. The COBRA method was then tested on a dedicated breast CT scanner with a custom-designed BT filter and compared to the conventional step-and-shoot characterization of the BT filter. Using basis decomposition of dual energy signal data, the thickness of the filter was estimated and compared to the BT filter's manufacturing specifications. The COBRA method was also demonstrated with a clinical whole body CT scanner using the body BT filter. The relative attenuation was calculated at four discrete x-ray tube potentials and used to estimate the thickness of the BT filter. Results: The prototype probe was found to have a linear and isotropic response to x-rays. The relative attenuation produced from the COBRA method fell within the error of the relative attenuation measured with the step-and-shoot method. The BT filter thickness estimates resulting from the dual energy scans on the breast CT system were equivalent to the manufacturing specifications. The clinical CT evaluation produced data conceptually similar to previous computer simulations and plausible relative attenuation profiles were observed. Conclusions: The COBRA method is a fast and accurate method for BT filter characterization, which requires a simple experimental setup in a clinical environment. Because of the ease of data acquisition, multienergy scans can be acquired which allow characterization of the BT filter thickness.
Addendum to: Corrective Action Decision Document/Corrective Action Plan (CADD/CAP) for the Subsurface Corrective Action Unit 447 Shoal, Nevada, Site
This document is an addendum to the original CADD/CAP. It includes the summaries of the corrective action activities, numeral model validation results, enhancements made to the monitoring program and monitoring network as implemented through three short-term data acquisition plans and updates made to SCMs since CADD/CAP approval in 2006.The document begins at Section 5.6 as a continuation of the "Implementation of the Corrective Action Plan" of the CADD/CAP. Table and figure numbers are in a sequence with the CADD/CAP.
Machine Learning-Enabled Wearable Piezoelectric Acoustic Sensor for Real-Time Breast Abnormality Detection
In contemporary society, breast health has become a significant public health concern, particularly among women. According to statistics from the World Health Organization, both the incidence and mortality rates of breast tumors have steadily increased in recent years. Therefore, effective early-stage screening and postoperative monitoring are essential for maintaining breast health. However, conventional clinical diagnostic modalities are typically bulky, operationally complex, and unsuitable for continuous real-time monitoring, which limits their use in portable and everyday health management applications. To address these limitations, this study proposes a machine learning-integrated wearable piezoelectric sensing platform as an auxiliary tool for breast health assessment. The device consists of a PDMS matching layer embedded with flexible silver nanowires, a P(VDF-TrFE) piezoelectric layer, and a multi-channel low-noise signal acquisition circuit. It is capable of acquiring acoustic echo signals from tissue-mimicking environments and automatically evaluating signal validity using a convolutional neural network (CNN). By integrating piezoelectric sensing with deep learning-based signal analysis, the proposed system achieves a signal-to-noise ratio exceeding 70 dB and a real-time classification accuracy above 96% under controlled conditions. These results demonstrate that the platform provides a compact, portable, and intelligent approach for wearable sensing of mechanical heterogeneity and highlight its potential for future development in continuous biomedical monitoring technologies.
Lidar measurements of yawed-wind-turbine wakes: characterization and validation of analytical models
Abstract. Wake measurements of a scanning Doppler lidar mounted on the nacelle of a full-scale wind turbine during a wake-steering experiment were used for the characterization of the wake flow, the evaluation of the wake-steering set-up, and the validation of analytical wake models. Inflow-scanning Doppler lidars, a meteorological mast, and the supervisory control and data acquisition (SCADA) system of the wind turbine complemented the set-up. Results from the wake-scanning Doppler lidar showed an increase in the wake deflection with the yaw angle and that the wake deflection was not in all cases beneficial for the power output of a downstream turbine due to a bias of the inflow wind direction perceived by the yawed wind turbine and the wake-steering design implemented. Both observations could be reproduced with an analytical model that was initialized with the inflow measurements. Error propagation from the inflow measurements that were used as model input and the power coefficient of a waked wind turbine contributed significantly to the model uncertainty. Lastly, the span-wise cross section of the wake was strongly affected by wind veer, masking the effects of the yawed wind turbine on the wake cross sections.