Search NASA⌕ Search

SEARCH · Search NASA

Results for “active load control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Performance Evaluation of Three RTU Energy Efficiency Technologies

This project was part of an effort by CLEAResult and ComEd to evaluate the energy saving potential of emerging technologies in the Chicago area. This project focused on evaluating emerging technologies related to rooftop units (RTUs). An RTU with a single-stage compressor and a constant-speed fan with an induction motor was selected as the baseline for technology comparison. Three retrofit strategies were investigated. The first two involved replacing the single-stage compressor of an RTU by either a two-stage or variable-speed compressor and adding a variable frequency drive (VFD) to the constant speed fan. The use of a multi-/variable-stage compressor improves the part-load efficiency of the compressor which will ultimately result in annual energy savings as well as peak demand shaving in some cases where the design capacity of the RTU is larger than the maximum cooling load of the building space that it is serving. The third technology was the use of a high rotor pole switched reluctance motor (SRM) as a replacement for the constant-speed supply fan. The SRM was applied in single-speed, two-stage and variable-speed compressor RTUs. SRM motors run via reluctance torque. Their stator poles are driven by direct current (DC) power and require an inverter as well as active control when using alternating current (AC) power. This inherent property results in high efficiency over a range of operating conditions. It also exhibits higher efficiency compared to variable frequency drives (VFDs) since its switching frequency is much slower (SCE, 2018).The three technologies investigated are summarized below: 1) Replacing the single-speed compressor with a two-stage compressor and adding a VFD to the supply fan. 2)Replacing the single-speed compressor with a variable-speed compressor and adding a VFD to the supply fan. 3) Replacing the constant-speed induction motor of the supply fan with a high rotor pole SRM. DOE’s building simulation platform EnergyPlus and its graphical user interface OpenStudio were used to evaluate the energy-saving potential of upgrading RTUs, by leveraging experimental data from previous research.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Seasonal Cost-Benefit Analysis of Automated Distribution Feeder Upgrades with Advanced Mitigation Technologies

The increasing deployment of distributed solar photovoltaics (DPV) to meet clean energy goals can trigger adverse grid operation issues, such as voltage excursions and the violation of thermal loading constraints of the power delivery elements (e.g., lines and transformers) on the evolving electricity infrastructure. Such integration issues would require distribution upgrades with associated costs to mitigate them and to maintain reliable and resilient grid operating conditions. Traditional distribution network upgrade approaches use a specific single snapshot analysis that is overly conservative. This study considers a multi-time point analysis to capture both moderate (probable bounds) and extreme grid operating conditions using time points such as minimum load with minimum photovoltaics (PV), maximum load with maximum PV, maximum load with minimum PV, and minimum load with maximum PV. Further, this study investigates seasonal variation impacts and associated distribution upgrade costs for a spring season case (March, representing a low load and high PV scenario) and a summer case (July, representing a high load and high PV scenario). Such seasonal analysis will allow system operators to characterize upgrade requirements and associated costs across various periods. Because the spatial distribution of DPV can impact upgrade and associated costs, this study investigates three common DPV deployment scenarios - randomly deployed, close to the substation, and far from the substation - at different penetration levels. Apart from spatial distribution impacts, this project evaluates the techno-economic impacts of the nodal photovoltaic penetration factor (NPPF) for generating the various DPV deployment scenarios at increasing penetration levels. This project investigates the impact of varying nodal PV-to-load ratios using conservative and extreme NPPF values of 3 and 10, respectively. This study investigates the deployment of traditional infrastructure upgrade strategies, such as installing new voltage regulating equipment, transformers and lines replacements, and the activation of advanced inverter functionality (e.g., autonomous volt/VAR) in expanding PV hosting capacity. Existing DPV systems are assumed to operate with the legacy unity power factor, and we considered the possibility of retrofitting such systems with the activation of volt/VAR control as integration standards and regulations continue to evolve to allow such functions. The cost-benefit analysis metrics used in study include distribution upgrade costs, average cost per watt of the upgrade cost, average marginal cost per watt of the upgrade cost, and power losses.

14 SOLAR ENERGY↗

Development of Property Composition Models For RPP-WTP LAW Glasses (Final Report)

This report describes the development of property-composition models for low-activity waste (LAW) glasses for the River Protection Project Waste Treatment Plant (RPP-WTP) at the Hanford site. The RPP-WTP will separate Hanford tank wastes into LAW and high-level waste (HLW) streams and each stream will be vitrified separately. The development of LAW and HLW glass formulations for the RPP-WTP has been reported previously and is an ongoing activity. Acceptable formulations must meet a variety of processability, product quality, and waste loading requirements that are dictated either by the RPP-WTP contract or by the characteristics of the particular treatment processes that have been selected. These requirements amount to constraints on the acceptable ranges of certain glass properties. These properties are determined first and foremost by the composition of the glass or glass melt. Thus, while there is no direct way of controlling the glass properties of interest during production, there are simple and extremely effective methods of achieving the same result by instead controlling the glass composition. This basic principle is no different from that used to produce enormous volumes of commercial glass to meet exacting product specifications. An essential difference in waste vitrification, however, is that one of the raw materials (the waste itself) can be subject to considerable compositional uncertainty and variability. Thus, waste vitrification facilities and associated process control systems (of which, the operating envelope in glass formulation space is a key part) must, of course, be designed to be robust with respect to such variations. The determination of quantitative relationships between the glass properties that must be controlled and the glass composition can play an important role in the development of such facilities.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Correlation Between Microscopic Current Fluctuations Observed at Ultra-Microelectrodes and Macroscopic Bulk Electrolysis Performance in Redox-Active Microemulsions

Microemulsions (μEs) have been proposed as redox flow battery (RFB) electrolytes that maximize ionic conductivity and charge capacity by synergizing two immiscible phases. However, charge transfer during electrolysis in μEs is poorly understood. Here, we show that ultramicroelectrode electrolysis of ferrocene-loaded μEs –20%, 60%, and 90% water - reveals stochastic current fluctuations. These are differentiated in the scanning electrochemical microscopy (SECM) geometry, where power spectral density analysis showed distinct changes in the frequency contributions. SECM in the substrate generation-tip collection mode showed that fluctuations arise under mass-transfer control. Significant differences in the diffusion coefficient of ferrocene species were deducted from SECM approach curves, suggesting phase transfer behavior. Using bulk electrolysis, we calculated the charge accessibility and cycling behavior in the μEs. A decrease in the stochastic behavior of the μEs seems to correlate to a higher accessibility and cycling performance, with the 90% water μE displaying the best reversibility and the 60% the lowest. Altogether, these results suggest that Marangoni-type convection driven by concentration gradients and/or μE restructuring during charge transfer play a role in the electrochemical performance of μEs. This presents opportunities for screening and diagnosing the performance of these emerging RFB electrolytes.

25 ENERGY STORAGE↗

Network Constraints Consideration for Grid-Edge Energy Management System

Increased deployment of distributed energy resources (DER) in distribution system is bringing need for enhanced grid intelligence, control, and flexibility. This is significant at the edge of the grid where DERs, loads or microgrids are located. Integrated DERs in a distribution system need to follow grid codes to avoid violations that results in DER disconnection. To comply with grid code requirements (e.g. IEEE 1547-2018) at the grid edge level, network constrained grid edge energy management system (GEEMS) is proposed in this paper. The objective of GEEMS is to provide economic solution for active and reactive power dispatch set-points at each interval and ensure voltage regulation to support secure interconnection of the grid edge segment to the distribution system. To evaluate the proposed GEEMS framework, four DERs are included into IEEE 13 bus system. GEEMS outperforms the existing economic dispatch-based energy management system by reducing the voltage violation.

Electric vehicle depot charging station↗

Using AI for Management of Field Emission in SRF Linacs

Field emission control, mitigation, and reduction is critical for reliable operation of high gradient superconducting radio-frequency (SRF) accelerators. With the SRF cavities at high gradients, the field emission of electrons from cavity walls can occur and will impact the operational gradient, radiological environment via activated components, and reliability of CEBAF’s two linacs. A new effort has started to minimize field emission in the CEBAF linacs by re-distributing cavity gradients. To measure radiation levels, newly designed neutron and gamma radiation dose rate monitors have been installed in both linacs. Artificial intelligence (AI) techniques will be used to identify cavities with high levels of field emission based on control system data such as radiation levels, cryogenic readbacks, and vacuum loads. The gradients on the most offending cavities will be reduced and compensated for by increasing the gradients on least offensive cavities. Training data will be collected during this year’s operational program and initial implementation of AI models will be deployed. Preliminary results and future plans are presented.

Carpenter, Adam↗

Using AI for Management of Field Emission in SRF Linacs

Field emission control, mitigation, and reduction is critical for reliable operation of high gradient superconducting radio-frequency (SRF) accelerators. With the SRF cavities at high gradients, the field emission of electrons from cavity walls can occur and will impact the operational gradient, radiological environment via activated components, and reliability of CEBAF’s two linacs. A new effort has started to minimize field emission in the CEBAF linacs by re-distributing cavity gradients. To measure radiation levels, newly designed neutron and gamma radiation dose rate monitors have been installed in both linacs. Artificial intelligence (AI) techniques will be used to identify cavities with high levels of field emission based on control system data such as radiation levels, cryogenic readbacks, and vacuum loads. The gradients on the most offending cavities will be reduced and compensated for by increasing the gradients on least offensive cavities. Training data will be collected during this year’s operational program and initial implementation of AI models will be deployed. Preliminary results and future plans are presented.

Carpenter, Adam↗

Core Design of the Holos-Quad Microreactor

The Holos-Quad micro-reactor concept, developed by HolosGen LLC, is equipped with a 22 MWt (Mega-Watt thermal) core and an integral power conversion system converting the core thermal energy into approximately 10 MWe (Mega-Watt electric). This design can be configured to support a wide range of applications. It is a very innovative high-temperature gas-cooled reactor concept using TRI-structural ISOtropic particle fuel (TRISO) distributed in graphite hexagonal blocks, cooled with helium in a direct Brayton cycle independently executed by four Subcritical Power Modules (SPMs) fitted into a hardened 40-foot container whose dimensions are in compliance with ISO shipping containers requirements. In FY2019 HolosGen LLC was awarded by the Department of Energy Advanced Research Project Agency-Energy (DOE ARPA-E) under the MEITNER funding program. As part of the MEITNER award, the Argonne National Laboratory (ANL) contributed expertise through two specialized teams: The “Design Team” and the “Resource Team”. The Design Team was dedicated to validate feasibility of the Holos-Quad core and to optimize its core design through neutronics analyses. The Resource Team was dedicated to feasibility verification via high-fidelity codes of Holos-Quad thermal-hydraulic, heat transfer, shielding, and structural aspects. This report summarizes the activities conducted by ANL Design Team. A rigorous design approach based on multi-criteria optimization and code-to-code comparison involving stochastic and high-fidelity deterministic solutions was developed and employed at several evolutionary stages of the Holos-Quad design. Several generations of the Holos-Quad core were designed within this project before converging to the current full-scale Gen 2+ design that is detailed in this report. Figure EA-1 illustrates a cross-sectional view of Gen 2+ Holos-Quad core configuration, and Figure EA-2 provides a simplified perspective view of 1-of-4 SPMs. The Holos-Quad uses four thermal-hydraulically independent SPMs locked into stationary positions during power operation, surrounded by BeO reflector and structural component fully comprised within the dimensional constraints represented by traditional ISO containers. One of the benefits of this approach is to enable transportation of each SPM promptly after irradiation in shielded containers. The core is designed to operate for approximately 8 full-power years while the reactivity controls and power conversion system enable load-following operations. The reactivity controls are represented by independent, diversified, and redundant reactivity control systems based on control drums and redundant sets of shutdown rods. The high-fidelity simulation tools were used to assess detailed power and flux distributions of the three-dimensional full-core or quarter-core of the Gen 2+ configuration. Single-physics and multi-physics simulations of the neutronics code PROTEUS and the thermal-hydraulic code System Analysis Module (SAM) were performed to analyze the Holos design configurations with detailed high-fidelity solutions. The design work performed confirmed feasibility of the Holos-Quad concept, provided realistic design description for detailed design of the operational system, and identified several core design improvements to be further considered for future reactor development activities.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Communications Reliability for Vehicle Grid Integration

Electric Vehicles (EVs) adoption rate has been steadily increasing in the US leading to a growing number of charging stations including faster DC (Direct Current) chargers and slower Level 1 and Level 2 AC (Alternating Current) chargers. This increase in demand for electricity is further exacerbated by recent developments in Artificial Intelligence (AI) technology, advanced manufacturing, and digitization. These factors will require electric utilities to upgrade their infrastructure to keep up with the increasing electrical demand (especially during peak hours). An easy way to counteract the need for these upgrades is to shift a major chunk of active charge sessions (durations where there is energy transfer from charger to EV's propulsion battery) to off-peak hours thereby flattening the load curve and making the infrastructure more resilient. This concept is known as Smart Charge Management (SCM). EV owners also benefit from SCM since it lowers their charging costs and consequently their transportation costs by prioritizing charging during off-peak hours. SCM takes advantage of EV's capability to act as a controllable load or DER (Distributed Energy Resource). This report summarizes the reliability analysis performed on the communication required for two of these SCM use-cases. This analysis only focuses on SCM strategies for unidirectional charging (energy transfer from EVSE to EV or V1G) and not bidirectional charging.

24 POWER TRANSMISSION AND DISTRIBUTION↗

OPET Hardware (Open PV Electrical Tool Hardware) [SWR-25-42]

OPET (Open-source Photovoltaic Electrical Tool) is used for performance measurements of solar photovoltaic (PV) devices in the field under natural sunlight or in the lab under artificial light. Its primary use is in research and development of solar cells and modules, specifically in reliability and durability research of PV devices. Some features and functions include: -IV curve measurements with linear or cosine distributed measurement points -PV device active loading at open circuit voltage (Voc), short circuit current (Isc) and maximum power point (Pmp) -Bias power supply to overcome series resistance in contact wires for Isc measurements and loading -PV voltage input in five ranges from 1V to 100V -PV current input ranges -Low current version, six current ranges from 1.1mA to 340mA -High current version, six current ranges from 50mA to 15A -IO ports for I2C and SPI temperature sensor Arduino extension boards -Integrated fan control This repository contains everything relating to the hardware of the OPET device. If you are looking for the firmware or software repositories, links are below: https://github.com/NREL/opet-firmware https://github.com/NREL/opet-control

McDanold, Byron [National Renewable Energy Laborat↗

Active Reconditioning of Retired Lithium-ion Battery Packs from Electric Vehicles for Second Life Applications

Utilizing the remaining capacity in retired lithium-ion (Li-ion) batteries from electric vehicles (EVs) for second-life applications has shown economic and environmental benefits. However, achieving homogeneity among the capacities of cells before their second life is critical to exploit the benefits. This article proposes a new active reconditioning approach with the potential to make short-term reconditioning of batteries before second life feasible. A control objective map determines each cell's state-of-charge (SOC) operating window based on its capacity relative to other cells. The SOC reference translates into distinct differential currents through the cells, wherein the higher-capacity cells undergo more frequent and deep charge and discharge cycles than their lower-capacity counterparts. The proposed solution achieves capacity homogeneity within the battery pack with low reconditioning time and minimal fade in the overall pack capacity. The feasibility of the reconditioning approach under varying load and environmental conditions is assessed through simulations, encompassing factors such as the number of cycles per day, depth-of-discharge, battery pack temperature, and cell resting time at different SOCs. Furthermore, the simulation model employs a battery pack with sixteen series-connected 75 Ah Kokam lithium nickel manganese cobalt oxide (NMC) cells with a 3.6% initial capacity imbalance. A reconditioning time of 1.3 months is achieved with a final capacity imbalance of 0.1% and an overall capacity fade of 0.005%, thereby confirming the viability of the reconditioning process. Moreover, experimental validation using eight retired battery cells from a Nissan Leaf demonstrates a substantial decrease in the capacity imbalance of cells from 9.4% to 2.15% within 78 days, effectively affirming the efficacy of the proposed reconditioning scheme.

25 ENERGY STORAGE↗

Design of the cryogenic moderator system for the second target station

The Second Target Station (STS) at Oak Ridge National Laboratory will be a 700 kW pulsed spallation neutron source designed to provide the world's highest brightness cold neutron beams. In order to produce the required neutron performance, two compact liquid hydrogen moderators are located adjacent to the tungsten spallation target and must be supplied with less than 20 K hydrogen and a para hydrogen fraction of 99.8% or greater. The Cryogenic Moderator System (CMS) will consist of a single hydrogen loop feeding the two moderators in series cooled by a helium refrigerator with a cooling capacity of 2.5 kW at 17 K. The hydrogen loop consists of a hydrogen circulator, hydrogen helium heat exchanger, ortho-para converter, accumulator, transfer lines and heater. The design of the hydrogen loop is based on the CMS design of the First Target Station at the Spallation Neutron Source and some of the component designs may be reused. General hydrogen temperature control is provided by controlling the flowrate of helium to the heat exchanger. The hydrogen loop will have a constant flowrate of 0.5 L/s and remove a nuclear heat load of about 850 W from the two moderators, which is deposited both directly in the hydrogen and the adjacent hydrogen containing structures. Because the nuclear heat load is accelerator driven, the hydrogen system must remain stable when the heat load is removed instantaneously during beam trips. System stability is maintained passively with the accumulator and actively with the heater. Ionizing radiation which interacts with the liquid hydrogen drives backconversion of the hydrogen from parahydrogen to orthohydrogen. The STS moderator performance is very sensitive to small fractions of orthohydrogen requiring an ortho-para converter to maintain the hydrogen supplied to the moderators at near equilibrium parahydrogen concentration. STS CMS is in the early stage of preliminary design and current focus is evaluating component sizing and system stability during beam transients.

Janney, Jim↗

Grid-Connected Modular Soft-Switching Solid State Transformers (M-S4T)

The objective of this project is to develop and verify the concept of a flexible and modular soft-switching solid-state transformer (M-S4T) for direct grid-connected applications. The ability to directly connect power electronics converters to the medium voltage grid (4 kV – 13 kV), and to potentially replace the passive and bulky, but ubiquitous 60 hertz service transformer in the 25 kVA to 100 kVA range, with a more flexible and controllable device, has been regarded as the ‘holy grail’ in grid control. However, this has proven to be extremely difficult. This project has developed the solutions to several key challenges of the direct grid-connected power electronics and realized a 7.2 kV M-S4T prototype. First, a protection method to protect the M-S4T from the high voltages (110 kV for the 13 kV system) that occur on the grid due to transients and lightning strikes have been developed and experimentally verified. Second, the realization and the operation of the M-S4T based on high-voltage SiC devices (>3.3 kV) and a medium-frequency medium-voltage low-leakage transformer in a single-stage solid-state transformer with zero-voltage switching, low dv/dt, and low electromagnetic interference has been successfully demonstrated up to 7.5 kV peak. Third, an oil-cooling system and stable communication and distributed control system for converter module voltage sharing have been developed and experimentally verified. The developed M-S4T has realized a modular universal high-performance power conversion system. This conversion system is scalable to different voltage and power levels and adaptable to four-quadrant bidirectional operation. Moreover, the use of passive cooling techniques meets the equipment life requirements, and the lightning protection scheme fulfills the basic insulation level specifications for direct grid connection. Such power conversion system opens up near-term opportunities, including energy storage, solar PV, or electric vehicle charging with significant cost and footprint savings. In the longer term, the possibility of replacing the utility distribution transformer with an M-S4T will be transformative for future distribution grids with a compact footprint and full controllability to enable high renewable energy and storage penetration. In addition to the main project, this report expands on the Plus-Up projected including as part of the main award. This project developed and demonstrated the technology for autonomous collaborative inverters that can be connected in an ad hoc manner to the grid. The aim of the project was to: (1) evaluate the existing techniques for grid-connected inverters and find their limitations; (2) develop detailed requirements for grid-connected inverters in the modern grid with millions of active nodes; (3) design a unified control strategy that brings more autonomy and intelligence to grid-connected inverters, and addresses parts of the issues with the existing techniques. The proposed technique, called UniCon, enables inverters to 1) connect/disconnect to/from the grid in an ad hoc manner; (2) work based on local sensing. Slow communication could be used for a more optimized behavior; (3) work automatically in both grid-forming/grid-following mode; (4) handle large disturbances, e.g., big load step and fault, in an oscillation-free manner; (5) work collaboratively with other inverters in steady-state and during transients. UniCon can be implemented in the middle-level control; hence it is agnostic to the vendor and to the implementation of the inner voltage/current and protection loops. Furthermore, a new synchronization scheme, based on deep learning, was developed that can extract the grid voltage phase and amplitude in a stable manner. The method is cheap to implement can improve the dynamic performance of the grid-connected inverters during fast transients, e.g., fault. The proposed control scheme was validated by (1) MATLAB/Simulink; (2) hardware-in-the-loop results, and; (3) experimental results using three inverters that form a microgrid in a down-scaled feeder. Lastly, both the M-S4T and UniCon have achieved promising tangible paths to markets. In the case of the M-S4T, the underlying technology — the Soft Switching Solid State Transformer (S4T) developed at the Georgia Tech Center for Distributed Energy (GT-CDE) has been licensed by GridBlock from the Georgia Tech Research Corporation, and GridBlock has been working with manufacturing partner Jabil (one of the largest US-based contract manufacturers) and system integrator Power Secure (largest deployer of microgrids in the US with 4.7 GW under management), to meet the strong initial demand. Similarly, GridBlock has an exclusive license to the UniCon technology, developed under this award by GT-CDE. The UniCon provides an intermediate control layer that enables the implementation of the higher-level ‘transactive’ control commands for the system. The architecture of the system - slow communications with the cloud for system optimization and setpoints, and the use of locally measured quantities for real-time control, provide a very robust and secure way of implementing a real-time must-run grid that is also secure and stable. This is a brand-new functionality that is critical for the future grid and key to GridBlock’s business model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Densification and microstructure features of lithium hydride fabrication

The manufacturing of lithium hydride (LiH) utilizing uniaxial pressing, which offers fabrication with tailorable properties via microstructure control, can lead to the expansion in application of LiH while bypassing the challenges presented by historical casting manufacturing techniques. Through control of consolidation conditions such as pressure, temperature, dwell time and powder load, the presented work highlights the densification of LiH, with an emphasis on quantifying oxygen content, for applications requiring a specific density range necessary for optimized material performance. Karl Fischer Titration and X-ray Diffraction proved useful in determining oxygen and phase content while Computed Tomography and Scanning Electron Microscopy provided structural analysis. The temperature dependent densification of LiH fit with an Arrhenius term resulted in an activation energy of 21.2 kJ/mol. Images of fractured surfaces of LiH pressed at 500 °C revealed drastic grain coarsening, aided by the presence of oxygen impurities.

36 MATERIALS SCIENCE↗

Designing Porous Ion Emitters for Thermal Ionization Mass Spectrometry: Evaluating Metal-Organic Frameworks

In this work we describe the first exploration of metal-organic frameworks (MOFs) as ‘next generation’ ion emitters for thermal ionization mass spectrometry (TIMS). MOFs were identified as promising candidates for this application given the synthetic control over their desired structural properties. This tunability results in well-ordered, high surface area, high porosity frameworks with targeted sorption affinities. Here we explored an aluminum-based, bipyridine-containing MOF (MOF-253) with and without incorporating the high work function metal, rhenium (Re). After analysis of a Nd-bearing MOF, we hypothesized that the well-dispersed, sponge-like interconnected network of the degraded structure would enhance Nd ionization more than traditional TIMS loading activators (i.e., phosphoric acid). Compared to filaments loaded with phosphoric acid that require an additional benzene carburization step, the Nd ionization efficiencies (atoms detected relative to atoms loaded) for heated filaments loaded with MOF-253 were similar (~1%). Electron microscopy after TIMS analysis demonstrated that the MOF was retained on the filament and, as hypothesized, preserved sub-micron porosity post analysis. While these results are preliminary, they demonstrate that MOFs have potential to enhance ionization and exceed the performance of traditional loading techniques by forming nano-porous ion emitters (nano-PIEs). Thus, further experimentation is likely to exceed this performance through more specific selection of the base MOF structure and modifications to porosity and composition. This work represents a novel application of MOFs and a next step in the pursuit of advanced thermal ionization with potential to expand across the periodic table.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ionic-content-driven restructuring of spirobisindane ionene networks: implications for mechanics, self-healing, and gas transport

Polymers of intrinsic microporosity (PIMs) offer exceptional gas permeability but remain brittle and susceptible to physical aging, limiting their durability in separation applications. Here, we introduce a reconfigurable microporous polymer network that uniquely integrates permanent PIM microporosity with autonomous, intrinsic self-healing driven by imidazolium-based ionic motifs. Spirobisindane units generate the intrinsic free-volume architecture, while an imidazolium-containing polyamide ionene supplies dynamic ionic and hydrogen-bonding interactions that reorganize under mild activation. Incorporation of imidazolium-based ionic liquids further tunes cohesion, mobility, and densification, enabling the network to relax, re-associate, and retain microporosity without structural collapse. Through a comprehensive multiscale approach combining spectroscopy, scattering, thermal and mechanical characterization with all-atom molecular dynamics and density functional theory calculations, we elucidate how ionic content, as a single control parameter that reshapes free-volume distributions, modulates local coordination environments, and governs relaxation and healing kinetics. At intermediate ionic loadings, the networks achieve rapid, repeatable self-healing while maintaining CO$_2$ selectivity, demonstrating an optimal balance between segmental mobility and structural integrity. By establishing how hierarchical ionic interactions couple structure, dynamics, and transport in microporous ionene networks, this work provides generalizable design rules for adaptive soft-matter systems that require simultaneous mechanical resilience, reconfigurability, and selective gas transport.

36 MATERIALS SCIENCE↗

Developing the Science Basis for Understanding Polymer Encapsulant Degradation Mechanisms: DuraMAT 2.0 Final Project Report

Polymeric encapsulants are essential materials in photovoltaic modules, protecting sensitive electronics from the environment while providing mechanical integrity to the multilayered assembly. However, these polymeric materials are susceptible to degradation processes driven by the ingress of environmental species, ultraviolet radiation, thermal stresses, and mechanical loading. In this study, we employ a combined atomistic simulation and accelerated aging experimental approach to study the molecular-scale mechanisms of encapsulant degradation. Classical molecular dynamics simulations quantify the diffusion of environmental and degradation species through the polymer matrix, producing composition-specific diffusion coefficients. Reactive simulations characterize activation energy barriers and reaction rate constants for key chemical pathways. In parallel, thermal-desorption analyses coupled with mass spectrometry monitor the emergence and concentration profiles of degradation products under controlled stressor conditions. By integrating simulation and experiment, we establish quantitative correlations between polymer composition, species diffusivity, and chemical reactivity. We anticipate that these relations and quantitative values could serve as high-fidelity inputs to reaction-diffusion models, enabling physics-informed lifetime predictions and guiding the design of more durable encapsulant materials for solar energy applications.

36 MATERIALS SCIENCE↗

Methanol Partial Oxidation on Cu(111) and PtCu(111) Single-Atom Alloy Surfaces: Effect of Surface Oxygen Coverage on Selectivity

The selective oxidation of methanol to formaldehyde on Cu surfaces is an important and well-studied reaction. However, a systematic analysis of product selectivity as a function of oxygen coverage on Cu(111) and Cu-based single-atom alloys (SAAs) has not been previously reported. In this work, we present a comprehensive investigation of deuterated methanol (CD 3 OH) partial oxidation on Cu(111) and 1% PtCu(111) SAA surfaces as a function of preadsorbed oxygen coverage. Temperature-programmed desorption (TPD) and X-ray photoelectron spectroscopy (XPS) reveal that isolated Pt atoms inhibit the initial surface oxidation of Cu(111) under low oxygen exposures. Despite this difference in oxidation kinetics, the product selectivity remains largely unaffected: on both Cu(111) and PtCu(111), formaldehyde (CD 2 O) is the predominant partial oxidation product over a broad range of oxygen coverages. The selectivity toward formaldehyde peaks at intermediate oxygen coverages (∼0.3 monolayers, ML), indicating the existence of an optimal oxygen loading for partial oxidation. Notably, the similar product selectivities on Cu(111) and PtCu(111) over a range of surface oxygen coverage indicate that Pt single atoms do not significantly alter the reaction pathway or shift the optimal oxygen coverage for formaldehyde formation. Control experiments confirm that Cu(111) is unreactive toward methanol in the absence of oxygen, while PtCu(111) surfaces produce a small amount of formaldehyde even when oxygen is not preadsorbed, indicating that isolated Pt atoms facilitate O−H activation at below 150 K, leading to H 2 desorption, followed by C−D activation at higher temperatures (∼350 K). Density functional theory (DFT)-based calculations show that Pt atoms increase the O 2 dissociation barrier relative to Cu(111), consistent with the observed inhibition of oxidation at low exposures. Overall, this work provides the first detailed selectivity map for methanol oxidation on oxidized Cu(111) and PtCu(111) SAA surfaces. By linking classical mechanistic insights such as methoxy- and formate-mediated pathways with single-atom alloy catalyst design, this work demonstrates that while Pt substitution modulates the oxidation kinetics and oxygen binding, the overall selectivity toward formaldehyde is governed primarily by oxygen coverage. These findings underscore the potential of isolated dopants to tune surface oxidation behavior without compromising the intrinsic partial oxidation selectivity of copper-based catalysts.

36 MATERIALS SCIENCE↗