Search NASA⌕ Search

SEARCH · Search NASA

Results for “adaptive power control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Residential photovoltaic power conditioning technology for grid connected applications

Major advances in photovoltaic (PV) Power Conditioning (PC) with respect to performance and low-cost potential have been made. Solutions have been obtained to interface and control problems related to adapting available inverter designs to the grid-connected, residential photovoltaic experiments. A description is presented to contributing research and development activities. Attention is given to aspects of residential systems experience, conceptual design studies, questions of optimum topology development, and promising advanced designs for residential PV provided by development efforts of the private sector.

Key, T. S.↗

XML in an Adaptive Framework for Instrument Control

NASA Goddard Space Flight Center is developing an extensible framework for instrument command and control, known as Instrument Remote Control (IRC), that combines the platform independent processing capabilities of Java with the power of the Extensible Markup Language (XML). A key aspect of the architecture is software that is driven by an instrument description, written using the Instrument Markup Language (IML). IML is an XML dialect used to describe interfaces to control and monitor the instrument, command sets and command formats, data streams, communication mechanisms, and data processing algorithms.

Ames, Troy J.↗

Improved Control Strategy of Grid-Forming Inverters for Fault Ride-Through in a Microgrid System

This paper develops an improved control strategy of grid-forming (GFM) inverters with fault ride-through capabilities to guarantee the stable operation of microgrids under fault conditions, especially islanded microgrids and asymmetrical faults. The proposed control strategy includes the dual control of positive-sequence and negative-sequence control as well as the adaptive virtual impedance (VI) control. Unlike existing works, the proposed strategy applies the VI control for only the d component of the positive-sequence control and leaves the q component of the positive-sequence control and the dq component of the negative-sequence control as zero, thus achieving improved stability and balanced three-phase voltages under asymmetrical faults. The adaptive feature of the VI control guarantees the stability of the GFM inverter under severe faults, which could cause the saturation of the inner current loop and instability if the VI is not adaptive. Simulation results of various unbalanced faults with high- and low-fault impedances show that the proposed control strategy improves the stability of the GFM inverter and achieves stable and balanced output voltages in islanded microgrids. And the algorithm also improves the stability of GFM inverters under balanced faults with high- and low-fault impedances.

adaptive virtual impedance control↗

Design analysis and computer-aided performance evaluation of shuttle orbiter electrical power system. Volume 1: Summary

Studies were conducted to develop appropriate space shuttle electrical power distribution and control (EPDC) subsystem simulation models and to apply the computer simulations to systems analysis of the EPDC. A previously developed software program (SYSTID) was adapted for this purpose. The following objectives were attained: (1) significant enhancement of the SYSTID time domain simulation software, (2) generation of functionally useful shuttle EPDC element models, and (3) illustrative simulation results in the analysis of EPDC performance, under the conditions of fault, current pulse injection due to lightning, and circuit protection sizing and reaction times.

Source record↗

Improved Control Strategy of Grid-Forming Inverters for Fault Ride-Through in a Microgrid System

This paper develops an improved control strategy of grid-forming (GFM) inverters with fault ride-through (FRT) capabilities to guarantee the stable operation of microgrids under fault conditions, especially islanded microgrids and asymmetrical faults. The proposed control strategy includes the dual control of positive-sequence and negative-sequence control as well as the adaptive virtual impedance (VI) control. Unlike existing works, the proposed strategy applies the VI control for only the d component of the positive-sequence control and leaves the q component of the positive-sequence control and the dq component of the negative-sequence control as zero, thus achieving improved stability and balanced three-phase voltages under asymmetrical faults. The adaptive feature of the VI control guarantees the stability of the GFM inverter under severe faults, which could cause the saturation of the inner current loop, and the instability if the VI is not adaptive. Simulation results of various unbalanced faults with high and low fault impedances show that the proposed control strategy improves the stability of the GFM inverter and achieves stable and balanced output voltages in islanded microgrids. And the algorithm also improves the stability of GFM inverters under balanced faults with high and low fault impedances.

adaptive virtual impedance control↗

Energy management system, method of controlling one or more energy storage devices and control unit for one or more power storage units

Systems, methods and apparatuses are provided for reducing peak energy demand and to smooth intermittent energy profiles from onsite variable energy sources and loads. Some embodiments use system level and device level analysis and optimization to adaptively adjust the operation of a behind the meter energy storage (BMES) to smooth out energy generation variabilities and follow a reference load signal, including at short time resolutions.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Technoeconomic Design Optimization for Fast Reactors. Part II: Impact of Technoeconomic Constraints on Optimal Design

There is a current drive toward optimizing reactors, particularly small/micro reactors to minimize cost and maximize performance. Previous work has investigated the development of technoeconomic workflows for the design optimization of pool-type fast reactors that aim to deploy into district energy grids. Initial scoping studies verified that the workflow was capable of capturing design trends throughout a variety of design configurations and problem formulations while remaining sufficiently flexible. In this paper, this methodology is applied to understand how cost functions and technoeconomic constraints can drive optimal reactor design. Specifically, the UPu10Zr-fueled fast reactor model from Part I is adapted to include changes in the fissile content limits, control rod worth limits, control rod drive cost, and assumed fuel form. In the case of constraint relaxation at fixed power (fissile content and control rod worth limits), cost sensitivities of 5% to 10% were uncovered. Multi-objective optimization at varying reactor power levels with individualized control rod drives for each assembly (as opposed to one operational and one safety drive) increased cost by $\$10$ to $\$25$ million and substantially altered the optimal core geometry, favoring geometries with substantially fewer control rod placements relative to baseline optimization. Finally, a multi-objective optimization was performed at varying power levels with the fuel form overhauled to metallic, high-assay low-enriched uranium–based U10Zr with more refined fuel cost models. In the case of uranium fueling, the costs increased by at least $50 million relative to the baseline case. Furthermore, economic fuel zoning and lower reactivity swing cores were recovered. Each case serves to demonstrate the value of applying technoeconomic workflows to initial reactor design scoping studies to better understand the trade-off for a proposed concept between different design options.

Argonne Reactor Computation (ARC) codes↗

Secondary Frequency Control for Reconfigurable Interconnecting Microgrids

Microgrids and microgrid technologies offer an operations and control framework for realizing the needed aggregation of a growing share of distributed energy resources. As the number of microgrids increases, so will the incentive to interconnect them, leading to a combinatorial growth of potential operating states. At the same time, their growing complexity nudges interconnected microgrids conceptually closer to balancing authorities in the bulk power system. This paper focuses on secondary frequency control and leverages the conceptual similarity between balancing authorities and interconnected microgrids to adopt an automatic generation control design with some adaptations. Frequency control and restoration is demonstrated via several use-cases with switching and reconfiguration events.

Schweitzer, Eran↗

Synchronizing Data-Bus Messages

Adapter allows communications among as many as 30 data processors without central bus controller. Adapter improves reliability of multiprocessor system by eliminating point of failure that causes entire system to fail. Scheme prevents data collisions and eliminates nonessential polling, thereby reducing power consumption.

Harris, L. H.↗

Evolving fuzzy rules in a learning classifier system

The fuzzy classifier system (FCS) combines the ideas of fuzzy logic controllers (FLC's) and learning classifier systems (LCS's). It brings together the expressive powers of fuzzy logic as it has been applied in fuzzy controllers to express relations between continuous variables, and the ability of LCS's to evolve co-adapted sets of rules. The goal of the FCS is to develop a rule-based system capable of learning in a reinforcement regime, and that can potentially be used for process control.

Valenzuela-Rendon, Manuel↗

Open-systems architecture of a standardized command interface chip-set for switching and control of a spacecraft power bus

The Jet Propulsion Laboratory (JPL) has developed a command interface chip-set that primarily consists of two mixed-signal ASICs'; the Command Interface ASIC (CIA) and Analog Interface ASIC (AIA). The Open-systems architecture employed during the design of this chip-set enables its use as both an intelligent gateway between the system's flight computer and the control, actuation, and activation of the spacecraft's loads, valves, and pyrotechnics respectfully as well as the regulator of the spacecraft power bus. Furthermore, the architecture is highly adaptable and employed fault-tolerant design methods enabling a host of other mission uses including reliable remote data collection. The objective of this design is to both provide a needed flight component that meets the stringent environmental requirements of current deep space missions and to add a new element to a growing library that can be used as a standard building block for future missions to the outer planets.

flight computers↗

Developing an Adaptable NextGen Interface for the UAS Ground Control Station

Presently a significant number of unmanned aircraft are not included in the existing National Airspace System surveillance system. This is due to many reasons including an inability to carry Automatic Dependent Surveillance Broadcast equipment for weight or power consumption deficiencies, legacy equipment usage, and the experimental nature of unmanned aircraft. In addition, pilots on the ground do not have the situation awareness to proximal aircraft pilots in the cockpit have. However, many unmanned aircraft utilize a link between the aircraft and ground control station that includes periodic updates to the aircraft position. Technologies have been developed to provide the existing national surveillance system with the location of the aircraft while at the same time providing the ground pilot a display with aircraft that are in the aircrafts proximity, thus expanding the national surveillance data as well as provide increased pilot situation awareness.

surveillance↗

Flexible Modem Interface (FMI) in Space - Extending Standardized Commercial Satellite Communications Services to Space Users

Recent innovations are producing a multitude of advanced commercial satellite communications (COMSATCOM) systems that could deliver massive amounts of SATCOM capacity at a fraction of current cost while also offering reliability and availability that is critical to achieving mission success for orbiting assets. Recognizing the alignment of commercial capabilities with the National Aeronautics and Space Administration's (NASA) diverse mission requirements, the agency is proactively engaging industry to formulate strategies leading towards a NASA communications architecture that includes advanced commercial capabilities. To fully leverage the expanded space resources, NASA must also address the integration of commercial waveforms into its space terminals. In pursuit of similar goals, the United States Department of Defense (DoD) is leading the standardization of the flexible modem interface (FMI) to address service integration for their tactical terminals in pursuit of a DoD Wideband SATCOM Enterprise.This paper describes how NASA is adapting this FMI standard to work with the Space Telecommunications Radio System (STRS) software-defined radio (SDR) framework to address the challenging size, weight, and power resource requirements for terminals in space. A full adaptation would include waveform compatibility with modular baseband processing, frequency compatibility with a wideband front end, and radiated beam control with an electronically steerable antenna to enable multi-provider commercial service capability in a feasible package for space terminals. Security is also a key aspect to be addressed for this integration since data will flow through commercial networks, commercial service providers have their own security mechanisms, and space terminals must be able to securely load proprietary software and firmware needed to access the commercial networks on demand. Success of this effort means commercial partners will be able to allow network-compliant implementations to be hosted on STRS-compliant SDRs in space for reliable and capable network access.

COMSATCOM↗

Grid-Connected Modular Soft-Switching Solid State Transformers (M-S4T)

The objective of this project is to develop and verify the concept of a flexible and modular soft-switching solid-state transformer (M-S4T) for direct grid-connected applications. The ability to directly connect power electronics converters to the medium voltage grid (4 kV – 13 kV), and to potentially replace the passive and bulky, but ubiquitous 60 hertz service transformer in the 25 kVA to 100 kVA range, with a more flexible and controllable device, has been regarded as the ‘holy grail’ in grid control. However, this has proven to be extremely difficult. This project has developed the solutions to several key challenges of the direct grid-connected power electronics and realized a 7.2 kV M-S4T prototype. First, a protection method to protect the M-S4T from the high voltages (110 kV for the 13 kV system) that occur on the grid due to transients and lightning strikes have been developed and experimentally verified. Second, the realization and the operation of the M-S4T based on high-voltage SiC devices (>3.3 kV) and a medium-frequency medium-voltage low-leakage transformer in a single-stage solid-state transformer with zero-voltage switching, low dv/dt, and low electromagnetic interference has been successfully demonstrated up to 7.5 kV peak. Third, an oil-cooling system and stable communication and distributed control system for converter module voltage sharing have been developed and experimentally verified. The developed M-S4T has realized a modular universal high-performance power conversion system. This conversion system is scalable to different voltage and power levels and adaptable to four-quadrant bidirectional operation. Moreover, the use of passive cooling techniques meets the equipment life requirements, and the lightning protection scheme fulfills the basic insulation level specifications for direct grid connection. Such power conversion system opens up near-term opportunities, including energy storage, solar PV, or electric vehicle charging with significant cost and footprint savings. In the longer term, the possibility of replacing the utility distribution transformer with an M-S4T will be transformative for future distribution grids with a compact footprint and full controllability to enable high renewable energy and storage penetration. In addition to the main project, this report expands on the Plus-Up projected including as part of the main award. This project developed and demonstrated the technology for autonomous collaborative inverters that can be connected in an ad hoc manner to the grid. The aim of the project was to: (1) evaluate the existing techniques for grid-connected inverters and find their limitations; (2) develop detailed requirements for grid-connected inverters in the modern grid with millions of active nodes; (3) design a unified control strategy that brings more autonomy and intelligence to grid-connected inverters, and addresses parts of the issues with the existing techniques. The proposed technique, called UniCon, enables inverters to 1) connect/disconnect to/from the grid in an ad hoc manner; (2) work based on local sensing. Slow communication could be used for a more optimized behavior; (3) work automatically in both grid-forming/grid-following mode; (4) handle large disturbances, e.g., big load step and fault, in an oscillation-free manner; (5) work collaboratively with other inverters in steady-state and during transients. UniCon can be implemented in the middle-level control; hence it is agnostic to the vendor and to the implementation of the inner voltage/current and protection loops. Furthermore, a new synchronization scheme, based on deep learning, was developed that can extract the grid voltage phase and amplitude in a stable manner. The method is cheap to implement can improve the dynamic performance of the grid-connected inverters during fast transients, e.g., fault. The proposed control scheme was validated by (1) MATLAB/Simulink; (2) hardware-in-the-loop results, and; (3) experimental results using three inverters that form a microgrid in a down-scaled feeder. Lastly, both the M-S4T and UniCon have achieved promising tangible paths to markets. In the case of the M-S4T, the underlying technology — the Soft Switching Solid State Transformer (S4T) developed at the Georgia Tech Center for Distributed Energy (GT-CDE) has been licensed by GridBlock from the Georgia Tech Research Corporation, and GridBlock has been working with manufacturing partner Jabil (one of the largest US-based contract manufacturers) and system integrator Power Secure (largest deployer of microgrids in the US with 4.7 GW under management), to meet the strong initial demand. Similarly, GridBlock has an exclusive license to the UniCon technology, developed under this award by GT-CDE. The UniCon provides an intermediate control layer that enables the implementation of the higher-level ‘transactive’ control commands for the system. The architecture of the system - slow communications with the cloud for system optimization and setpoints, and the use of locally measured quantities for real-time control, provide a very robust and secure way of implementing a real-time must-run grid that is also secure and stable. This is a brand-new functionality that is critical for the future grid and key to GridBlock’s business model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The X-15 3-65 Accident: An Aircraft Systems and Flight Control Perspective

Despite the NASA X-15 program's outstanding success in developing and operating the first manned hypersonic research platform, the program suffered a fatal accident on November 15, 1967, when X-15-3, the only aircraft outfitted with advanced pilot displays and an adaptive flight control system, was lost after entering uncontrolled flight at an altitude of 230,000 feet and a velocity near Mach 5. The pilot, Major Michael J. Adams, was incapacitated by the aircraft accelerations and was killed either during the ensuing breakup or upon ground impact. In light of mitigating risk to current and emerging manned aerospace vehicles, a comprehensive systems level analysis of the accident is presented with a focus on the electrical power, flight control, and instrumentation failures that affected not only the vehicle dynamics but substantially impacted the pilot decisions that led to an inevitable loss of control. Insights based on reconstructed flight data as well as analysis and simulation of the X-15's unique adaptive control system, yield new conclusions about the reasons for the control systems anomalous behavior and the system-level interactions and human-machine interface design oversights that led to the accident.

Accident Investigation↗

Attention Enabled Multi-Agent DRL for Decentralized Volt-VAR Control of Active Distribution System Using PV Inverters and SVCs

This paper proposes attention enabled multi-agent deep reinforcement learning (MADRL) framework for active distribution network decentralized Volt-VAR control. Using the unsupervised clustering, the whole distribution system can be decomposed into several sub-networks according to the voltage and reactive power sensitivity relationships. Then, the distributed control problem of each sub-network is modeled as Markov games and solved by the improved MADRL algorithm, where each sub-network is modeled as an adaptive agent. An attention mechanism is developed to help each agent focus on specific information that is mostly related to the reward. All agents are centrally trained offline to learn the optimal coordinated Volt-VAR control strategy and executed in a decentralized manner to make online decisions with only local information. Compared with other distributed control approaches, the proposed method can effectively deal with uncertainties, achieve fast decision makings, and significantly reduce the communication requirements. Comparison results with model-based and other data-driven methods on IEEE 33-bus and 123-bus systems demonstrate the benefits of the proposed approach.

distribution network↗

Instrumentation and Control Needs for Reliable Operation of Lunar Base Surface Nuclear Power Systems

As one of the near-term goals of the President's Vision for Space Exploration, establishment of a multi-person lunar base will require high-endurance power systems which are independent of the sun, and can operate without replenishment for several years. These requirements may be obtained using nuclear power systems specifically designed for use on the lunar surface. While it is envisioned that such a system will generally be supervised by humans, some of the evolutions required maybe semi or fully autonomous. The entire base complement for near-term missions may be less than 10 individuals, most or all of which may not be qualified nuclear plant operators and may be off-base for extended periods thus, the need for power system autonomous operation. Startup, shutdown, and load following operations will require the application of advanced control and health management strategies with an emphasis on robust, supervisory, coordinated control of, for example, the nuclear heat source, energy conversion plant (e.g., Brayton Energy Conversion units), and power management system. Autonomous operation implies that, in addition to being capable of automatic response to disturbance input or load changes, the system is also capable of assessing the status of the integrated plant, determining the risk associated with the possible actions, and making a decision as to the action that optimizes system performance while minimizing risk to the mission. Adapting the control to deviations from design conditions and degradation due to component failures will be essential to ensure base inhabitant safety and mission success. Intelligent decisions will have to be made to choose the right set of sensors to provide the data needed to do condition monitoring and fault detection and isolation because of liftoff weight and space limitations, it will not be possible to have an extensive set of instruments as used for earth-based systems. Advanced instrumentation and control technologies will be needed to enable this critical functionality of autonomous operation. It will be imperative to consider instrumentation and control requirements in parallel to system configuration development so as to identify control-related, as well as integrated system-related, problem areas early to avoid potentially expensive work-arounds . This paper presents an overview of the enabling technologies necessary for the development of reliable, autonomous lunar base nuclear power systems with an emphasis on system architectures and off-the-shelf algorithms rather than hardware. Autonomy needs are presented in the context of a hypothetical lunar base nuclear power system. The scenarios and applications presented are hypothetical in nature, based on information from open-literature sources, and only intended to provoke thought and provide motivation for the use of autonomous, intelligent control and diagnostics.

Turso, James↗

Development of a reaction wheel attitude control system for sounding rocket experiments and small Shuttle-based free flyers

A three-axis reaction wheel control system is currently under development. Initial emphasis is on a magnetic field reference, although the system is easily adaptable to other positional references, e.g., the gyroscopic. The system is housed in a skin section 17.25 inches in diameter and approximately 10 inches long. Current weight estimate is 75 pounds. An orthogonal triad of dc motors forms the basis of the system. Power is provided by silver-zinc cells and controlled by an 8-bit microprocessor. The control law is presented and the dynamical equations derived. Simulation results show that a payload with a roll MOI of 4.1 sl/sq ft and a transverse MOI of 20.3 sl/sq ft can typically be reoriented 90 degrees in 20-35 seconds, depending upon the initial body rates.

Ward, P. R.↗