Search NASA⌕ Search

SEARCH · Search NASA

Results for “air ducts”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

The Applicability of Jet-Shear-Layer Mixing and Effervescent Atomization for Low-NO(x) Combustors

An investigation has been conducted to develop appropriate technologies for a low-NO(x), liquid-fueled combustor. The combustor incorporates an effervescent atomizer used to inject fuel into a premixing duct. Only a fraction of the combustion air is used in the premixing process. This fuel-rich mixture is introduced into the remaining combustion air by a rapid jet-shear-layer mixing process involving radial fuel-air jets impinging on axial air jets in the primary combustion zone. Computational modeling was used as a tool to facilitate a parametric analysis appropriate to the design of an optimum low-NO(x) combustor. A number of combustor configurations were studied to assess the key combustor technologies and to validate the three-dimensional modeling code. The results from the experimental testing and computational analysis indicate a low-NO(x) potential for the jet-shear-layer combustor. Key features found to affect NOx emissions are the primary combustion zone fuel-air ratio, the number of axial and radial jets, the aspect ratio and radial location of the axial air jets, and the radial jet inlet hole diameter. Each of these key parameters exhibits a low-NO(x) point from which an optimized combustor was developed Also demonstrated was the feasibility of utilizing an effervescent atomizer for combustor application. Further developments in the jet-shear-layer mixing scheme and effervescent atomizer design promise even lower NO(x) with high combustion efficiency.

Colantonio, R. O.↗

Blended Wing Body Systems Studies: Boundary Layer Ingestion Inlets With Active Flow Control

A CFD analysis was performed on a Blended Wing Body (BWB) aircraft with advanced, turbofan engines analyzing various inlet configurations atop the aft end of the aircraft. The results are presented showing that the optimal design for best aircraft fuel efficiency would be a configuration with a partially buried engine, short offset diffuser using active flow control, and a D-shaped inlet duct that partially ingests the boundary layer air in flight. The CFD models showed that if active flow control technology can be satisfactorily developed, it might be able to control the inlet flow distortion to the engine fan face and reduce the powerplant performance losses to an acceptable level. The weight and surface area drag benefits of a partially submerged engine shows that it might offset the penalties of ingesting the low energy boundary layer air. The combined airplane performance of such a design might deliver approximately 5.5% better aircraft fuel efficiency over a conventionally designed, pod-mounted engine.

Geiselhart, Karl A.↗

Response of a Bifurcated Shock Train to Combustion Drive Force Dynamics

A bifurcated normal shock train in a Mach 2.2 constant area, rectangular duct is investigated in the combustion driven Air Force Research Lab RC-18 Sub-scale Direct Connect Supersonic Combustion Facility. High-speed shadowgraph images are captured simultaneously with high-speed wall static pressure measurements along the isolator and combustor walls. The establishment of the shock train following ignition is studied to better understand the flow pathways and fluid dynamical mechanisms that link combustor dynamics to the motions and stability of the isolator shock train. To that end, cross-spectral and wavelet analysis is leveraged to determine the spectral and temporal characteristics of upstream traveling disturbances on the isolator-combustor system in RC-18.

Shock Train↗

A Preliminary Study of the Prevention of Ice on Aircraft by the Use of Engine-exhaust Heat

An investigation was made in the N.A.C.A. ice tunnel at air temperatures from 20 degrees to 28 degrees Fahrenheit and at a velocity of 80 miles per hour to determine whether ice formations on a model wing could be prevented by the use of the heat from the engine-exhaust gas. Various spanwise duct systems were tested in a 6-foot-chord N.A.C.A. 23012 wing model. The formation of ice over the entire wing chord was prevented by the direct heating of the forward 10 percent of the wing by hot air, which was passed through leading-edge ducts. Under dry conditions, enough heat to maintain the temperature of the forward 10 percent of the wing at about 200 degrees Fahrenheit above that of the ambient air was required for the prevention of ice formation. The air temperature in the ducts that was necessary to produce these skin temperatures varied from 360 degrees to 834 degrees Fahrenheit; the corresponding air velocities in the duct were 152 and 45 feet per second. Ice formations at the leading edge were locally prevented by air that passed over the interior of the wing surface at a velocity of 30 feet per second and a temperature of 122 degrees Fahrenheit.

Rodert, Lewis A↗

Investigation Flow Uniformity in a Supersonic Duct with High Enthalpy Flows

Flow uniformity in a high enthalpy facility is investigated. The scramjet research facility is composed of a rectangular combustor duct connected to a 100 MW electric arc air heater. The Mach 3.3 flow is accelerated through a two-dimensional contoured nozzle. Instream measurements were made with water-cooled Pitot probes and stagnation point heat flux gages at stream enthalpy levels ranging from 4 to 7 Mj/kg. Flow surveys were made on the flow centerline and off centerline in order to measure the three dimensional uniformity of the flow in the rectangular duct. Measurements indicated that although the flow in the aspect ratio 6:1 duct was relatively uniform on the centerline, three dimensional viscous effects were apparent near the corners. Flow through the nozzle and constant area duct was modeled computationally using a two dimensional, Navier-Stokes, reacting gas code. The computations predict that the flow in the test section is in vibrational equilibrium. The computed and measured Pitot pressure and heat flux profiles are in reasonable agreement with the experimental data.

Balboni, John↗

Low-cost orbiting grinder for cutting ducts

Low-cost, portable machine cuts ducts made from heat-treated alloys. An abrasive wheel, powered by a high-speed air motor mounted on an expandible plug against the inner wall of the duct, gives precise cutting.

Lang, E. J.↗

Energy Savings With Acceptable Indoor Air Quality Through Improved Airflow Control in Residential Retrofits

The Partnership for Advanced Residential Retrofit (PARR) has been a U.S. Department of Energy (DOE) Building America team since 2009, with a primary focus on upgrading the performance of existing buildings to reduce energy loads. In this project, PARR’s work explored the integration of airflow-focused measures in residential retrofit homes with the goal to maximize energy savings while ensuring acceptable indoor air quality (IAQ) using a systems approach to controlling four contributing air streams: • Building air leakage (natural, uncontrolled infiltration), • Forced-air distribution system static pressure and airflow rate, • Distribution system duct leakage, and • Mechanical ventilation. This project addressed airflows in houses, their combined impact on energy use and IAQ, and the comparative effects of typical insulation and air sealing practices versus integrated system-level retrofits. Additionally, practical considerations for contractors taking either approach were addressed. Finally, the effects of supply ventilation and exhaust ventilation on IAQ were compared in occupied homes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Mole fraction imaging of transverse injection in a ducted supersonic flow

Laser-induced iodine fluorescence has been used to generate two-dimensional images of the mixing characteristics of air injected transversely as underexpanded jets behind a rearward-facing step into a ducted Mach 2 freestream; the images thus obtained were processed digitally in order to yield planar-injectant mole fraction distributions. The resulting planar images represent a three-dimensional data base of the injectant mole fraction distribution throughout the flowfield which is then used to reconstruct images exhibiting mole-fraction distributions normal to the duct. These images furnish a direct representation of the evolution of supersonic mixing along the duct, and facilitate the development of one-dimensional mixing schedules on the basis of the three-dimensional data base.

Abbitt, John D. Iii↗

Hydrogen disposal investigation for the Space Shuttle launch complex at Vandenberg Air Force Base

The concern of an overpressure condition on the aft end of the Space Shuttle caused by ignition of unburned hydrogen being trapped in the Space Shuttle Main Engine exhaust duct at the Vandenberg AFB launch complex has been investigated for fifteen months. Approximately twenty-five concepts have been reviewed, with four concepts being thoroughly investigated. The four concepts investigated were hydrogen burnoff ignitors (ignitors located throughout the exhaust duct to continuously ignite any unburned hydrogen), jet mixing (utilizing large volumes of high pressure air to ensure complete combustion of the hydrogen), steam inert (utilizing flashing hot water to inert the duct with steam) and open duct concept (design an open duct or above grade J-deflector to avoid trapping hydrogen gas). Extensive studies, analyses and testing were performed at six test sites with technical support from twenty-two major organizations. In December 1986, the Air Force selected the steam inert concept to be utilized at the Vandenberg launch complex and authorized the design effort.

Breit, Terry J.↗

Flow friction in a wide rectangular duct with a beveled inlet: Informal Notes of Fundamental Fluid Physics Studies

Fundamental streamwise pressure distributions were measured at Idaho State University to address a primary objective of obtaining insight into the apparent evolution of air flow regimes at moderate Reynolds numbers in thin, wide rectangular ducts with converging inlets. Ducts of 3.030 and 4.077 mm spacings s (called three and four mm), having non-dimensional lengths of (L/s) ≈ 500.8 and 372.2 and widths (W/s) ≈ 114.6 and 83.2, respectively, were compared. Flow rates ranged from Reynolds numbers based on hydraulic diameter (Re Dh ) of about 980 to 10,000 and corresponding non-dimensional downstream pressure gradient parameters (-K p ) covered the range 0.038 to 0.0061, respectively.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Performance of a multiple venturi fuel-air preparation system

Spatial fuel-air distributions, degree of vaporization, and pressure drop were measured 16.5 cm downstream of the fuel injection plane of a multiple Venturi tube fuel injector. Tests were performed in a 12 cm tubular duct. Test conditions were: a pressure of 0.3 MPa, inlet air temperature from 400 to 800K, air velocities of 10 and 20 m/s, and fuel-air ratios of 0.010 and 0.020. The fuel was Diesel #2. Spatial fuel-air distributions were within + or - 20 percent of the mean at inlet air temperatures above 450K. At an inlet air temperature of 400K, the fuel-air distribution was measured when a 50 percent blockage plate was placed 9.2 cm upstream of the fuel injection plane to distort the inlet air velocity fuel injection plane to distort the inlet air velocity profile. Vaporization of the fuel was 50 percent complete at an inlet air temperature of 400K and the percentage increased linearly with temperature to complete vaporization at 600K. The pressure drop was 3 percent at the design point which was three times greater than the designed value and the single tube experiment value. No autoignition or flashback was observed at the conditions tested.

Tacina, R. R.↗

Bypass Duct Acoustic Liner Design With and Without Bifurcation Effects

The growth in air traffic and the commitment to sustainable aviation continue to provide new challenges to reducing aircraft noise levels. Acoustic liner design methodologies must therefore provide the capability to efficiently predict the acoustic benefits of novel liner configurations within complex aircraft nacelle geometries. With these observations in mind, a broadband acoustic liner optimization process has been developed and assessed through a series of design and experimental studies at increasing technology readiness levels. This work applies the design process to the aft-fan noise component and explores the effects of bypass duct bifurcations (e.g., the pylon and lower bifurcation). In addition to this new application, the design study is expanded to include the use of a commercially available duct propagation code. Despite the different general workflow for the two propagation codes, consistent optimized impedance spectra and in-duct attenuation predictions were obtained for several acoustic treatment options. The preliminary results are promising, and this work increases confidence in the enhanced broadband liner design methodology and lays the groundwork for complimentary use of the codes in future studies. The potential benefits of acoustic treatment on the upper and lower bifurcations are also demonstrated. The knowledge gained through this preliminary stage of the liner design process will be used to guide the identification of candidate liner designs for a proposed static engine test within the next year.

Acoustic Liner Design↗

Bypass Duct Acoustic Liner Design with and without Bifurcation Effects

The growth in air traffic and the commitment to sustainable aviation continue to provide new challenges to reducing aircraft noise levels. Acoustic liner design methodologies must therefore provide the capability to efficiently predict the acoustic benefits of novel liner configurations within complex aircraft nacelle geometries. With these observations in mind, a broadband acoustic liner optimization process has been developed and assessed through a series of design and experimental studies at increasing technology readiness levels. This work applies the design process to the aft-fan noise component and explores the effects of bypass duct bifurcations (e.g., the pylon and lower bifurcation). In addition to this new application, the design study is expanded to include the use of a commercially available duct propagation code. Despite the different general workflow for the two propagation codes, consistent optimized impedance spectra and in-duct attenuation predictions were obtained for several acoustic treatment options. The preliminary results are promising, and this work increases confidence in the enhanced broadband liner design methodology and lays the groundwork for complimentary use of the codes in future studies. The potential benefits of acoustic treatment on the upper and lower bifurcations are also demonstrated. The knowledge gained through this preliminary stage of the liner design process will be used to guide the identification of candidate liner designs for a proposed static engine test within the next year.

Acoustic Liner Design↗

Experimental aerodynamic evaluation of the SSME two-duct, hot gas manifold

An investigation was performed on an improved Space Shuttle Main Engine (SSME) hot gas manifold (HGM) design using a full scale HGM model in cold-flow, air-blowdown tests. The new HGM design replaces the current three transfer ducts with two enlarged elliptical transfer ducts, faired duct inlets, and enlarged fuel bowl. Extensive experimental results have been obtained to verify previous results showing that the two-duct design improved the HGM internal flow path by eliminating separated flow regions, reducing high local velocities, and providing more uniform flow.

Kim, B. Y.↗

Combined Devices for Turbulent-Drag Reduction

Aircraft skin-friction drag reduced as much as 15 percent. One effective drag-reduction technique involves use of riblets. Riblets are longitudinal striations or grooves machined on originally smooth surface. Grooves alined with flow. Grooves have depths and spacings on order of turbulent wallstreak and burst dimensions and designed to change near-wall structure of turbulent boundary layer. Another approach, using large-eddy-breakup (LEBU) devices, or turbulence manipulators or ribbons also demonstrated reductions in local skin friction and net drag in air. LEBU device consists of thin, ribbonlike strips or airfoils suspended parallel to test surface and positioned within turbulent boundary layer. Technique potentially reduce net skin-friction drag by at least 15 percent on turbulent boundary layer of aircraft, representing possible annual savings in fuel costs of $300 to $400 million for U.S. commercial fleet. Also applicable to frictionloss reduction inside pipes and ducts, contributing to increased efficiency of pumps, heat exchangers, air conditioners, and other devices involving fluid flow.

Walsh, M. J.↗

Evaluation of a Brayton cycle recuperator after 21,000 hours of ground testing

A metallographic examination was conducted on a Brayton cycle recuperator and associated ducting after 21,000 hours of ground testing in air. At the hot (turbine) end, the recuperator operated at a nominal temperature of 675 C. The type 347 stainless-steel recuperator performed satisfactorily in the ground test even though the primary working fluid leaked to the atmosphere periodically. The leakage path was located at plate-bar braze joints which cracked as a result of thermal stresses. The welded type 347 stainless steel ducting a type 347/Hastelloy X bellows survived the ground test with no apparent loss of ductility or integrity. Some apparent aging embrittlement was observed in the Hastelloy X ducting but the serviceability was not affected.

Moore, T. J.↗

ResStock Measure Documentation: Residential Two-Stage Geothermal Heat Pump (4.0 COP, 20.5 EER) With Light Envelope Improvements

This report is part of series describing a variety of different ResStock(TM) measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "Residential Two-Stage Geothermal Heat Pump (4.0 COP, 20.5 EER) With Light Envelope Improvements" measure upgrade methodology and briefly discusses key results. All results can be accessed on the ResStock Open Energy Data Initiative "End-Use Load Profiles for the U.S. Building Stock" data lake and on the data viewer at resstock.nlr.gov.

15 GEOTHERMAL ENERGY↗