Search NASA⌕ Search

SEARCH · Search NASA

Results for “array detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

The Cosmology Large Angular Scale Surveyor (CLASS): 38 GHz Detector Array of Bolometric Polarimeters

The Cosmology Large Angular Scale Surveyor (CLASS) experiment aims to map the polarization of the Cosmic Microwave Background (CMB) at angular scales larger than a few degrees. Operating from Cerro Toco in the Atacama Desert of Chile, it will observe over 65% of the sky at 38, 93, 148, and 217 GHz. In this paper we discuss the design, construction, and characterization of the CLASS 38 GHz detector focal plane, the first ever Q-band bolometric polarimeter array.

CMB↗

Development of a Silicon Drift Detector Array: An X-ray Fluorescence Spectrometer for Remote Surface Mapping

Over the past three years NASA Marshall Space Flight Center has been collaborating with Brookhaven National Laboratory to develop a modular Silicon Drift Detector (SDD) X-Ray Spectrometer (XRS) intended for fine surface mapping of the light elements of the moon. The value of fluorescence spectrometry for surface element mapping is underlined by the fact that the technique has recently been employed by three lunar orbiter missions; Kaguya, Chandrayaan-1, and Chang'e. The SDD-XRS instrument we have been developing can operate at a low energy threshold (i.e. is capable of detecting Carbon), comparable energy resolution to Kaguya (<150 eV at 5.9 keV) and an order of magnitude lower power requirement, making much higher sensitivities possible. Furthermore, the intrinsic radiation resistance of the SDD makes it useful even in radiation-harsh environments such as that of Jupiter and its surrounding moons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a Silicon Drift Detector Array: An X-Ray Fluorescence Spectrometer for Remote Surface Mapping

Over the past three years NASA Marshall Space Flight Center has been collaborating with Brookhaven National Laboratory to develop a modular Silicon Drift Detector (SDD) X-Ray Spectrometer (XRS) intended for fine surface mapping of the light elements of the moon. The value of fluorescence spectrometry for surface element mapping is underlined by the fact that the technique has recently been employed by three lunar orbiter missions; Kaguya, Chandrayaan-1, and Chang e. The SDD-XRS instrument we have been developing can operate at a low energy threshold (i.e. is capable of detecting Carbon), comparable energy resolution to Kaguya (<150 eV at 5.9 keV) and an order of magnitude lower power requirement, making much higher sensitivities possible. Furthermore, the intrinsic radiation resistance of the SDD makes it useful even in radiation-harsh environments such as that of Jupiter and its surrounding moons.

Gaskin, Jessica A.↗

Bolometric Array Detectors for Space-Borne Astronomy

Funding from the NASA Innovative Research Grant was used to develop bolometric detectors. As described in the proposal, silicon nitride micromesh ('spider-web') absorbers had been demonstrated at U.C. Berkeley but not developed to be flight-worthy devices. We proceeded to first fabricate bolometers with Neutron Transmutation Doped (NTD) Ge thermistors that demonstrated high optical coupling (Church et al. 1996) and were developed for a ground-based millimeter-wave receiver (Mauskopf et al. 1997). The next generation of devices used In bump-bonded thermistors to achieve devices with performance product NEP*sqrt(tau) = 3e - 18 j at 300 mK, demonstrating a full order of magnitude improvement over pervious devices. These devices achieved an NEP = 1e-18 W/rtHz (Murray et al. 1996) as promised in the proposal. Sensitivities as good as 1e - 19 W/rtHz appear achievable with the silicon nitride architecture (Bock et al. 1997). Finally, arrays of micromesh bolometers were shown to be feasible in the last year of the program by etching a large number of devices on a single silicon wafer (75 mm). Full arrays were subsequently demonstrated for selection on the ESA/NASA Far-Infrared Space Telescope (FIRST) in competition with detectors provided by CEA in France and GSFC in the US Micromesh bolometer arrays are now baselined for both the ESA/NASA Planck and FIRST missions.

Lange, Andrew E.↗

Large-format electrographic and array detectors for a space Schmidt imaging telescope

Possible optical designs of imaging detectors for the spaceborne Schmidt telescope proposed by Carruthers et al. (1990) are discussed, surveying the currently or potentially available technology. Consideration is given to FUV electrographic detectors of large format (e.g., 120 mm with 10-micron resolution) using CsI photocathodes, the possible extension of the same technology to the mid-UV using Cs2Te instead of CsI, large CCD arrays for the visible and NIR, electron-bombarded CCDs for the FUV and mid-UV, and the data handling and processing requirements of these detectors.

Carruthers, George R.↗

Multiplexed 256 element InGaAs detector arrays for 0.8-1.7-micron room-temperature operation

InGaAs photodetectors have been configured into linear arrays of 30 x 30 micron photodetectors spaced 50 microns apart. The devices have typical responsivities of 0.9 A/W (86-percent QE) at 1.3 microns and exhibit room temperature dark currents below 100 pA. A 256-element array has been mounted in a Reticon multiplexer and configured into a PAR optical multichannel analyzer to extend spectral response out to 1.7 microns. Individual InGaAs detectors have been fabricated for response out to 2.2 microns with dark current below 1 microA (-1V) and 50-percent QE at room temperature.

Olsen, G. H.↗

A report on laboratory performance of the spectroscopic detector arrays for SPIRE/HSO

We report the performance of the flight bolometer arrays for the Spectral and Photometric Imaging REceiver (SPIRE) instrument to be on board of the Herschel Space Observatory (HSO). We describe the test setup for the flight Bolometric Detector Assembly (BDA) that allows the characterization of its performance, both dark and optical, in one instrument’s cool down. We summarize the laboratory procedure to measure the basic bolometer parameters, optical response time, optical efficiency of bolometer and feedhorn, dark and optical noise, and the overall thermal conductance of the BDA unit. Finally, we present the test results obtained from the two flight units, Spectroscopic Long Wavelength (SLW) and Spectroscopic Short Wavelength (SSW).

Hargrave, P. C.↗

Cone-beam breast computed tomography with a displaced flat panel detector array

Purpose: In cone-beam computed tomography (CBCT), and in particular in cone-beam breast computed tomography (CBBCT), an important issue is the reduction of the image artifacts produced by photon scatter and the reduction of patient dose. In this work, the authors propose to apply the detector displacement technique (also known as asymmetric detector or ''extended view'' geometry) to approach this goal. Potentially, this type of geometry, and the accompanying use of a beam collimator to mask the unirradiated half-object in each projection, permits some reduction of radiation dose with respect to conventional CBBCT and a sizeable reduction of the overall amount of scatter in the object, for a fixed contrast-to-noise ratio (CNR). Methods: The authors consider a scan configuration in which the projection data are acquired from an asymmetrically positioned detector that covers only one half of the scan field of view. Monte Carlo simulations and measurements, with their CBBCT laboratory scanner, were performed using PMMA phantoms of cylindrical (70-mm diameter) and hemiellipsoidal (140-mm diameter) shape simulating the average pendant breast, at 80 kVp. Image quality was evaluated in terms of contrast, noise, CNR, contrast-to-noise ratio per unit of dose (CNRD), and spatial resolution as width of line spread function for high contrast details. Results: Reconstructed images with the asymmetric detector technique deviate less than 1% from reconstruction with a conventional symmetric detector (detector view) and indicate a reduction of the cupping artifact in CT slices. The maximum scatter-to-primary ratio at the center of the phantom decreases by about 50% for both small and large diameter phantoms (e.g., from 0.75 in detector view to 0.40 in extended view geometry at the central axis of the 140-mm diameter PMMA phantom). Less cupping produces an increase of the CT number accuracy and an improved image detail contrast, but the associated increase of noise observed may produce a decrease of detail CNR. By simulating the energy deposited inside the phantoms, the authors evaluated a maximum 50% reduction of the absorbed dose at the expense of a decrease of CNR, for the half beam irradiation of the object performed with the displaced detector technique with respect to full beam irradiation. The decrease in CNR, and in absorbed dose as well, translates into a detail CNRD showing values comparable to or higher than the ones obtained for a conventional symmetric detector technique, attributed to the effect of decreased scatter in particular at the axis of the irradiated object. An estimate is provided (about 12%) for the average dose reduction possible in CBBCT at constant CNR for the average uncompressed breast (14 cm diameter, 50% glandularity), in case of minimum image overlapping in extended view. Conclusions: Simulations and experiments show that CBCT reconstructions with the displaced detector technique and with a half beam collimator are less affected by scatter artifacts, which could lead to some decrease of the radiation dose to the irradiated object with respect to a conventional reconstruction. This dose reduction is associated with increase of noise, decrease of CNR, but equal or improved CNRD values. The use of a small area detector would allow also to reduce the apparatus cost and to improve the data transfer speed with a corresponding increment of frame rate.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development of Short Wavelength Infrared Array Detectors for Space Astronomy Application

The Smithsonian Astrophysical Observatory (SAO) and its team - the University of Arizona (UA), the University of Rochester (UR), Santa Barbara Research Center (SBRC), Ames Research Center (ARC), and Goddard Space Flight Center (GSFC) - are carrying out a research program with the goal of developing and optimizing infrared arrays in the 2-27 micron range for space infrared astronomy. This report summarizes research results for the entire grant period 1 January 1992 through 30 June 1996.

Fazio, Giovanni G.↗

Integrated treatment of detector arrays for source tracking.

Illicit radioactive sources can potentially appear in a wide range of public venues. One element in a plan for managing such sources involves searching for them in venues at risk and tracking them in real time when they are detected. A treatment of source tracking using multiple directional detectors in a probabilistic framework is given. The performance of a prototype directional detector based on these methods was characterized in the laboratory. Instances where the performance of a directional detector is not immune to the effects of shielding are identified.

07 ISOTOPE AND RADIATION SOURCES↗

Performance of multiplexed Ge:Ga detector arrays in the far infrared

The performance of two multi-element, multiplexed Ge:Ga linear arrays under low-background conditions was investigated. The on-focal switching is accomplished by MOSFET switches, and the integrated charge is made available through MOSFET source followers. The tests were conducted at 106 microns, and the radiation on the detectors was confined to a spectral window 1.25 microns wide using a stack of cold filters. At 4.2 K, the highest responsivity was 584 A/W, the noise equivalent power was 1.0 x 10(exp -16) W/square root of Hz, and the read noise was 6100 electrons/sample. A detailed description of the test setup and procedure is presented.

Farhoomand, Jam↗

Evaluation of a far infrared Ge:Ga multiplexed detector array

The performance of a multielement Ge:Ga linear array under low-background conditions is investigated. On-focal plane switching is accomplished by MOSFET switches and the integrated charge is made available through MOSFET source followers. The tests were conducted at 106 microns and the radiation on the detectors was confined to a spectral window 1.25 microns wide using a stack of cold filters. At 4.2 K, the responsivity was measured to be nominally 584 A/W, and the NEP was 1.0 x 10 exp -16 W/sq rt Hz. A detailed description of the test setup and the procedure is presented.

Farhoomand, Jam↗

Room temperature detector array technology for the terahertz to far-infrared.

Thermal detection has made extensive progress in the last 40 years, however, the speed and detectivity can still be improved. The advancement of silicon photonic microring resonators has made them intriguing for detection devices due to their small size and high quality factors. Implementing silicon photonic microring or microdisk resonators as a means of a thermal detector gives rise to higher speed and detectivity, as well as lower noise compared to conventional devices with electrical readouts. This LDRD effort explored the design and measurements of silicon photonic microdisk resonators used for thermal detection. The characteristic values, consisting of the thermal time constant ({tau} {approx} 2 ms) and noise equivalent power were measured and found to surpass the performance of the best microbolometers. Furthermore the detectivity was found to be D{sub {lambda}} = 2.47 x 10{sup 8} cm {center_dot} {radical}Hz/W at 10.6 {mu}m which is comparable to commercial detectors. Subsequent design modifications should increase the detectivity by another order of magnitude. Thermal detection in the terahertz (THz) remains underdeveloped, opening a door for new innovative technologies such as metamaterial enhanced detectors. This project also explored the use of metamaterials in conjunction with a cantilever design for detection in the THz region and demonstrated the use of metamaterials as custom thin film absorbers for thermal detection. While much work remains to integrate these technologies into a unified platform, the early stages of research show promising futures for use in thermal detection.

36 MATERIALS SCIENCE↗

WE-AB-BRB-09: Real Time In Vivo Scintillating Fiber Array Detector for Medical LINACS

Purpose: An in vivo transmission scintillation fiber detector was developed to monitor patient treatment in real time for the enhancement of patient safety and treatment accuracy. The detector system is capable of monitoring each pulse from a medical LINAC during treatment to determine the dose delivered as treatment progresses. Methods: The detector system consists of 60 parallel scintillating fibers coupled to fast data processing optoelectronics that can monitor the beam fluence in real time. Each 2.5mm{sup 2} square fiber is aligned with an MLC leaf pair and is long enough to capture a 40cm field. The fibers are embedded within a water equivalent polymer substrate that is secured in the LINAC accessory tray. The fibers are coupled to high speed photosensors and front end amplifiers that filter noise and pass each pulse to a high speed analog-to-digital converter. The system components are capable of detecting pulse repetition times shorter than what is delivered by a medical LINAC to ensure true real time data acquisition. Results: The system was able to capture and record the signal from each linac pulse and display the information in real time with no pulse pile up. It was found that the fiber array attenuates 2.65% of the beam which can easily be compensated for in treatment planning. The fibers responded linearly with dose, are independent of clinical beam energies, and are independent of dose rate. Calibration of the system was performed as a function of beam energy, beam size, dose rate, and monitor units to optimize beam fluence error detection. Conclusion: The detector system presented provides true real time in vivo beam monitoring to enhance patient safety and treatment delivery accuracy. Furthermore, the detector can be used for current patient specific QA.

60 APPLIED LIFE SCIENCES↗

Measurement of {nu}-bar{sub e}-e scattering cross section with CsI(Tl) detector array and the Beyond Standard Model constraints

A search of {nu}-bar{sub e}-e scattering cross section was carried out at the Kuo-Sheng nuclear power station. Based on 29882 and 7369 kg-days of reactor ON/OFF data, respectively, at an average reactor ON {nu}-bar{sub e} flux of 6.4x10{sup 12} cm{sup -2} s{sup -1}, the standard model (SM) electroweak interaction was probed at the squared 4-momentum transfer range of Q{sup 2}{approx}3x10{sup -6} GeV{sup 2}. The ratio of experimental to SM cross section was measured [1.08{+-}0.21(stat){+-}0.16(sys)]. We placed the constraints on the electroweak parameters (g{sub V},g{sub A}), corresponding to a weak mixing angle measurement of sin{sup 2}{theta}{sub W} = 0.251{+-}0.031(stat){+-}0.024(sys). A Point Contact Germanium Detector (PCGe) of mass 1 kg has been installed at a new underground laboratory 'China Jin-Ping Laboratory (CJPL)' in China.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Neutrinoless Double-Beta Decay Searches and Other Fundamental Physics Measurements with Ultra-Low Background Enriched-Germanium Detector Arrays

This award funded research on the MAJORANA DEMONSTRATOR neutrinoless double-beta decay search. The project encompassed three major goals and objectives. The first was construction and commissioning of the MAJORANA DEMONSTRATOR. My group members played a significant role in the project’s successful construction and commissioning. The second major objective was the MAJORANA DEMONSTRATOR data analysis and related activities, in which my group played a leading role in the collaboration. In addition to coordinating the entire analysis, my group was responsible for the development of several of the primary analysis parameters, as well as many lower-level components. This effort brought to fruition a number of important publications, including the release of the MAJORANA DEMONSTRATOR’s first limits on neutrinoless double beta decay and its measurements of its background levels. The third goal was to perform auxiliary background studies and future detector R&D with a local HPGe detector test stand. The test stand was constructed and operated, and is ready to be used for subsequent R&D under the purview of the MAJORANA DEMONSTRATOR’s follow-on experiment, LEGEND.

07 ISOTOPE AND RADIATION SOURCES↗