Search NASA⌕ Search

SEARCH · Search NASA

Results for “atrophy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Three Hierarchies in Skeletal Muscle Fibre Classification Allotype, Isotype and Phenotype

Immunocytochemical analyses using specific anti-myosin antibodies of mammalian muscle fibers during regeneration, development, and after denervation have revealed two distinct myogenic components determining fiber phenotype. The jaw-closing muscles of the cat contain superfast fibers which express a unique myosin not found in limb muscles. When superfast muscle is transplanted into a limb muscle bed, regenerating myotubes synthesize superfast myosin independent of innervation. Reinnervation by the nerve to a fast muscle leads to the expression of superfast and not fast myosin, while reinnervation by the nerve to a slow muscle leads to the expression of a slow myosin. When limb muscle is transplanted into the jaw muscle bed, only limb myosins are synthesized. Thus jaw and limb muscles belong to distinct allotypes, each with a unique range of phenotype options, the expressions of which may be modulated by the nerve. Primary and secondary myotubes in developing jaw and limb muscles are observed to belong to different categories characterized by different patterns of myosin gene expression. By taking into consideration the pattern of myosins synthesized and the changes in fiber size after denervation, 3 types of primary (fast, slow, and intermediate) fibers can be distinguished in rat fast limb muscles. All primaries synthesize slow myosin soon after their formation, but this is withdrawn in fast and intermediate primaries at different times. After neonatal denervation, slow and intermediate primaries express slow primaries hypertrophy with other fibers atrophy. In the mature rat, the number of slow fibers in the EDL is less than the number of slow primaries. Upon denervation, hypertrophic slow fibers matching the number and topographic distribution of slow primaries appear, suggesting that a subpopulation of the slow primaries acquire the fast phenotype during adult life, but reveal their original identity as slow primaries in response to denervation by hypertrophying and synthesizing slow myosin. It is proposed that within each muscle allotype, the various isotypes of primary and secondary fibers are myogenically determined, and are derived from different lineage of myoblasts.

Hoh, Joseph F. Y.↗

Spacelab Life Sciences 1 - Dedicated life sciences mission

The Spacelab Life Sciences 1 (SLS-1) mission is discussed, and an overview of the SLS-1 Spacelab configuration is shown. Twenty interdisciplinary experiments, planned for this mission, are intended to explore the early stages of human and animal physiological adaptation to space flight conditions. Biomedical and gravitational biology experiments include cardiovascular and cardiopulmonary deconditioning, altered vestibular functions, altered metabolic functions (including altered fluid-electrolyte regulation), muscle atrophy, bone demineralization, decreased red blood cell mass, and altered immunologic responses.

Womack, W. D.↗

Effects Of Exercise During Prolonged Bed Rest

Report describes experiment to investigate effects of isotonic and isokinetic leg exercises in counteracting effects of bed rest upon physical and mental conditions of subjects. Data taken on capacity for work, endurance and strength, tolerance to sitting up, equilibrium, posture, gait, atrophy, mineralization and density of bones, endocrine analyses concerning vasoactivity and fluid and electrolyte balances, intermediary metabolism of muscles, mood, and performance.

Arnaud, S.↗

Exercise/recreation facility for a Lunar or Mars analog

Discussed here is a project to design an exercise/recreation station for an earth based simulator of a lunar or Martian habitat. Specifically, researchers designed a stationary bicycle that will help people keep fit and prevent muscular atrophy while stationed in space. To help with motivation and provide an element of recreation during the workout, the bicycle is enhanced by a virtual reality system. The system will simulate various riding situations and the choice of mountain bike or road bike. The bike employs a magnetic brake that provides continuously changing tension to simulate actual riding conditions. This braking system will be interfaced directly with the virtual reality system. Also integrated into the virtual reality system will be a monitoring system that regulates heart rate, work rate, and other functions during the course of the session.

Source record↗

Skeletal muscle responses to unweighting in humans

An overview of earth-based studies is presented emphasizing the data on muscular strength and size derived from experiments under simulated microgravity. The studies involve the elimination of weight-bearing responsibility of lower-limb human musculature to simulate the unweighting effects of space travel in the absence of exercise. Reference is given to bedrest and unilateral lower-limb suspension, both of which provide data that demonstrate the decreased strength of the knee extensors of 20-25 percent. The response is related to the decrease in cross-sectional area of the knee extensors which is a direct indication of muscle-fiber atrophy. Most of the effects of unweighting are associated with extensor muscles in the lower limbs and not with postural muscles. Unweighting is concluded to cause significant adaptations in the human neuromuscular system that require further investigation.

Dudley, Gary A.↗

Countermeasures against space flight related bone loss

A general review is presented of data on bone loss with references to countermeasures for use during spaceflight and bedrest. The two primary countermeasures against skeletal atrophy are skeletal loading such as centrifugation and exercise and/or the administration of drugs designed to alter the rate of bone remodeling. Bone loss is argued to be unavoidable in long-duration spaceflight in spite of countermeasures utilized, but a combination of exercise, biochemical treatments, and post-flight therapy is considered the optimal solution.

Leblanc, Adrian↗

Muscle sarcomere lesions and thrombosis after spaceflight and suspension unloading

Data obtained during Cosmos 2044 bisatellite mission are reviewed and found to be consistent with the results of previous rodent spaceflight experiments. Investigation was carried out of hindlimb muscles from flight rats killed as close to land as possible so that changes induced by spaceflight and early readaptation to weight bearing could be distinguished from the changes that resulted from the two-day postflight period during Cosmos 1887. Results presented pertain to muscle atrophy and fiber type changes, eccentric contraction-like lesions, microcirculatory changes and interstitial edema, and tissue damage.

Riley, D. A.↗

Cardiac morphology after conditions of microgravity during Cosmos 2044

Light- and electron-microscopic studies were performed on cardiac muscle from rats flown on Cosmos 2044 and from four control groups. Average cross-sectional area of myofibers was measured by video analysis of the light-microscopic images of papillary and ventricular muscle samples from all animals. This cross-sectional area was significantly decreased in flight rats (P = 0.03) compared with synchronous controls. Additional findings at the electron microscopic level consistent with this atrophy were obtained by stereological analysis and optical diffraction analysis of papillary muscle samples. Slightly higher mitochondrial volume density values and mitochondria-to-myofibril ratios as well as normal A-band spacings (d1,0) and Z-band spacings of myofibrils were observed in the tail-suspension and flight groups. General morphological features similar to those in ventricular samples from the previous Cosmos 1887 flight were observed.

Goldstein, Margaret A.↗

Exercise during long term exposure to space: Value of exercise during space exploration

There appear to be two general physiological reasons why exercise will be beneficial to space travelers who will experience a weightless and isolated environment for many months or a few years: (1) to alleviate or prevent tissue atrophy (principally bone and muscle), to maintain cardiovascular function, and to prevent deleterious changes in extracellular and cellular fluid volumes and plasma constituents, especially electrolytes; and (2) to maintain whole organism functional physical and physiological status with special reference to neuromuscular coordination (physical skill) and physical fitness (muscle strength and power, flexibility, and aerobic endurance). The latter reason also relates well to the ability of the crew members to resist both general and local fatigue and thus ensure consistent physical performance. Various forms of exercise, performed regularly, could help alleviate boredom and assist the travelers in coping with stress, anxiety, and depression. The type, frequency, duration and intensity of exercise and ways of ensuring that crew members engage in it are discussed.

Source record↗

Design of a resistive exercise device for use on the Space Shuttle

The National Aeronautics and Space Administration in conjunction with the Universities Space Research Association sponsored the design of a Resistive Exercise Device (RED) for use on the Space Shuttle. The device must enable the astronauts to perform a number of exercises to prevent skeletal muscle atrophy and neuromuscular deconditioning in microgravity environments. The RED must fit the requirements for limited volume and weight and must provide a means of restraint during exercise. The design team divided the functions of the device into three major groups: methods of supplying force, methods of adjusting force, and methods of transmitting the force to the user. After analyzing the three main functions of the RED and developing alternatives for each, the design team used a comparative decision process to choose the most feasible components for the overall design. The design team selected the constant force spring alternative for further embodiment. The device consists of an array of different sized constant force springs which can be pinned in different combinations to produce the required output forces. The force is transmitted by means of a shaft and gear system. The final report is divided into four sections. An introduction section discusses the sponsor background, problem background and requirements of the device. The second section covers the alternative designs for each of the main functions. The design solution and pertinent calculations comprises the third section. The final section contains design conclusions and recommendations including topics of future work.

Carlson, Dennis L.↗

Exercise/recreation facility for a lunar or Mars analog

The University of Idaho, NASA/USRA project for the 1990-91 school year is an exercise/recreation station for an Earth-based simulator of a lunar or martian habitat. Specifically, a stationary bicycle that will help people keep fit and prevent muscular atrophy while stationed in space was designed. To help with motivation and provide an element of recreation during the workout, the bicycle is to be enhanced by a virtual reality system. The system simulates various riding situations, including the choice of a mountain bike or a road bike. The bike employs a magnetic brake that provides continuously changing tension to simulate actual riding conditions. This braking system is interfaced directly with the virtual reality system. Also, integrated into the virtual reality display will be a monitoring system that regulates heart rate, work rate, and other functions during the course of the session.

Source record↗

Regional changes in muscle mass following 17 weeks of bed rest

This work reports on the muscle loss and recovery after 17 wk of continuous bed rest and 8 wk of reambulation in eight normal male volunteers. Muscle changes were assessed by urinary levels of 3-methylhistidine (3-MeH), nitrogen balance, dual-photon absorptiometry (DPA), magnetic resonance imaging (MRI), and isokinetic muscle performance. The total body lean tissue loss during bed rest calculated from nitrogen balance was 3.9 +/- 2.1 kg. Although the total loss is minimal, DPA scans showed that nearly all of the lean tissue loss occurred in the lower limbs. Similarly, MRI muscle volume measurements showed greater percent loss in the limbs relative to the back muscles. MRI, DPA, and nitrogen balance suggest that muscle atrophy continued throughout bed rest with rapid recovery after reambulaton. Isokinetic muscle strength decreased significantly in the thigh and calf with no loss in the arms and with rapid recovery during reambulation.

Leblanc, Adrian D.↗

Muscle glucose uptake in the rat after suspension with single hindlimb weight bearing

An examination is conducted of the effect of nonweight-bearing conditions, and the systemic influences of simulated microgravity on rat hindlimb muscles. The results obtained suggest that the increases in hindlimb muscle glucose uptake and extracellular space associated with simulated microgravity persist with hindlimb weightbearing, despite the prevention of muscle atrophy. The mechanism (or mechanisms) responsible for these effects are currently unknown.

Stump, Craig S.↗

Endocrine and metabolic changes in payload specialist (L-1)

The endocrine system plays an important role in the adaptation to unusual environments by secreting hormones to control metabolism. Since human beings have long evolved on the surface of the Earth under a gravity environment, the weightless environment must be quite unusual for them. The purpose of this experiment is to study the mechanisms of human adaptation to a weightless environment from endocrine and metabolic changes. Our study plan is focused on four major physiological changes which were reported during past space flights or which may be expected to occur under that condition: (1) hormone and metabolic changes associated with fluid shift; (2) bone demineralization and muscle atrophy; (3) altered circadian rhythm; and (4) stress reaction during space flight.

Matsui, Nobuo↗

Design of a recumbent seating system

Future space shuttle missions presented by NASA might require the shuttle to rendezvous with the Russian space station Mir for the purpose of transporting astronauts back to earth. Due to the atrophied state of these astronauts, a special seating system must be designed for their transportation. The main functions of this seating system are to support and restrain the astronauts during normal reentry flight and to dampen some of the loading that might occur in a crash situation. Through research, the design team developed many concept variants for these functional requirements. By evaluating each variant, the concepts were eliminated until the four most attractive designs remained. The team used a decision matrix to determine the best concept to carry through embodiment. This concept involved using struts for support during reentry flight and a spring damper/shock absorber system to dampen crash landing loads. The embodiment design process consisted of defining the layout of each of the main functional components, specifically, the seat structure and the strut structure. Through the use of MCS/pal two, the design was refined until it could handle all required loads and dampen to the forces specified. The auxiliary function carriers were then considered. Following the design of these components, the complete final layout could be determined. It is concluded that the final design meets all specifications outlined in the conceptual design. The main advantages of this design are its low weight, simplicity, and large amount of function sharing between different components. The disassembly of this design could potentially present a problem because of time and size constraints involved. Overall, this design meets or exceeds all functional requirements.

Croyle, Scott↗

Specification list and function structure for a full-body dynamometer to be used aboard Space Station Freedom

NASA has a need for a machine which can be used as an exercise device and as an instrument to measure an astronaut's muscle performance. The purpose of the exercise device is to work various muscle groups of the astronaut to prevent muscle atrophy, the loss of muscle strength and mass from prolonged exposure to a microgravity environment. The measurement part of the machine will be used to collect data on the strength and power of the astronaut's muscle groups to be used in studies examining the effects of prolonged space inhabitation. The principle device used in this machine to both exercise and measure muscle performance is the dynamometer. The dynamometer converts electrical energy to mechanical energy and mechanical energy to electrical energy or signals. The task of the designer will be to incorporate a dynamometer into a device which can meet all of the needs discussed above. This memorandum has two sections which clarify the design task of producing a full-body dynamometer. The first section is a specification list. The specification list provides the requirements that the designer must meet in his/her design. The second part is a function structure. The function structure shows graphically the flow of material, energy, and information through the machine. These two items will be used by the designer in the design process for the full-body dynamometer.

Mcmahan, Robert↗

Orbital management and design considerations for NiCd satellite power systems

Several recently manufactured 50 and 60 ampere hour aerospace NiCd battery cell lots, produced by Gates Aerospace Batteries, are prone to premature on orbit performance degradation. The failure mechanism is cadmium migration, and the consequent development of soft shorts. A Martin Marietta Astronautics satellite program instituted an orbital management strategy for a set of these batteries that reduced the rate of degradation and brought the system to stable operation. This strategy involves: (1) minimizing the accumulated battery overcharge; (2) regular discharge exercises; and (3) periodic battery reconditioning. Because of changes in the NiCd cell manufacturing process, the actual performance of subsequent lots of NiCd cells is open to question. Future NiCd based power system designs should therefore allow for fine control of charge parameters, and an on orbit battery reconditioning capability. To minimize risk, it is much better to perform a full life test to qualify the cells before launch, rather than in parallel with orbital operations. If there are any changes in the manufacturing process of cells, it is extremely important to maintain very strong cognizance of secondary subcontractors, recognizing that the cell and battery manufacturing discipline is easily atrophied.

Tausch, Benjamin J., II↗

Leg muscle volume during 30-day 6-degree head-down bed rest with isotonic and isokinetic exercise training

Magnetic resonance imaging (MRI) was used to compare the effect of two modes of lower-extremity exercise training on the mass (volume) of posterior leg group (PLG) muscles (soleus, flexor hallucis longus, tibialis posterior, lateral and medial gastrocnemius, and flexor digitorum longus) on 19 men (ages 32-42 years) subjected to intense dynamic-isotonic (ITE, cycle ergometer, number of subjects (N) = 7), isokinetic (IKE, torque egrometer, N = 7), and no exercise (NOE, N = 5) training for 60 min/day during head-down bed rest (HDBR). Total volume of the PLG muscles decreased (p less than 0.05) similarly: ITE = 4.3 +/- SE 1.6%, IKE = 7.7 +/- 1.6%, and NOE = 6.3 +/- 0.8%; combined volume (N = 19) loss was 6.1 +/- 0.9%. Ranges of volume changes were 2.6% to -9.0% (ITE), -2.1% to -14.9% (IKE), and -3.4% to -8/1% (NOE). Correlation coefficients (r) of muscle volume versus thickness measured with ultrasonography were: ITE r + 0.79 (p less than 0.05), IKE r = 0.27 (not significant (NS)), and NOE r = 0.63 (NS). Leg-muscle volume and thickness were highly correlated (r = 0.79) when plasma volume was maintained during HDBR with ITE. Thus, neither intensive lower extremity ITE nor IKE training influence the normal non-exercised posterior leg muscle atrophy during HDBR. The relationship of muscle volume and thickness may depend on the mode of exercise training associated with the maintenance of plasma volume.