Search NASA⌕ Search

SEARCH · Search NASA

Results for “border”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Onset of chaos in a single-phase power electronic inverter

Supported by experiments on a power electronic DC/AC converter, this paper considers an unusual transition from the domain of stable periodic dynamics (corresponding to the desired mode of operation) to chaotic dynamics. The behavior of the converter is studied by means of a 1D stroboscopic map derived from a non-autonomous ordinary differential equation with discontinuous right-hand side. By construction, this stroboscopic map has a high number of border points. It is shown that the onset of chaos occurs stepwise, via irregular cascades of different border collisions, some of which lead to bifurcations while others do not.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Multi-frequency inversion-charge pumping for charge separation and mobility analysis in high-k/InGaAs metal-oxide-semiconductor field-effect transistors

An alternative multi-frequency inversion-charge pumping (MFICP) technique was developed to directly separate the inversion charge density (N{sub inv}) from the trapped charge density in high-k/InGaAs metal-oxide-semiconductor field-effect transistors (MOSFETs). This approach relies on the fitting of the frequency response of border traps, obtained from inversion-charge pumping measurements performed over a wide range of frequencies at room temperature on a single MOSFET, using a modified charge trapping model. The obtained model yielded the capture time constant and density of border traps located at energy levels aligned with the InGaAs conduction band. Moreover, the combination of MFICP and pulsed I{sub d}-V{sub g} measurements enabled an accurate effective mobility vs N{sub inv} extraction and analysis. The data obtained using the MFICP approach are consistent with the most recent reports on high-k/InGaAs.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Interplay between Superconductivity and Magnetism in Fe1-xPdxTe

The love/hate relationship between superconductivity and magnetic ordering has fascinated the condensed matter physics community for a century. In the early days, magnetic impurities doped into a superconductor were found to quickly suppress superconductivity. Later, a variety of systems, such as cuprates, heavy fermions and Fe pnictides, show superconductivity in a narrow region near the border to antiferromagnetism (AFM) as a function of pressure or doping. On the other hand, the coexistence of superconductivity and ferromagnetic (FM) or AFM ordering is found in a few compounds (RRh4B4 (R = Nd, Sm, Tm, Er), R'Mo6X8 (R' = Tb, Dy, Er, Ho, and X = S, Se), UMGe (M = Ge, Rh, Co), CeCoIn5, EuFe2(As1-xPx)2 etc.), providing evidence for their compatibility. Here, we present a third situation, where superconductivity coexists with FM and near the border of AFM in Fe1-xPdxTe. The doping of Pd for Fe gradually suppresses the first-order AFM ordering at temperature TN/S, and turns into short-range (SR) AFM correlation with a characteristic peak in magnetic susceptibility at T'N. Superconductivity sets in when T'N reaches zero. However, there is a gigantic ferromagnetic dome imposed in the superconducting-AFM (SR) crossover regime. Such a system is ideal for studying the interplay between superconductivity and two types of magnetic interactions (FM and AFM).

Karki, A B↗

TWIST, WRITHE, AND HELICITY IN THE INNER PENUMBRA OF A SUNSPOT

The aim of this work is the determination of the twist, writhe, and self-magnetic helicity of penumbral filaments located in an inner sunspot penumbra. For this purpose, we inverted data taken with the spectropolarimeter on board Hinode with the SIR (Stokes Inversion based on Response function) code. For the construction of a three-dimensional geometrical model we applied a genetic algorithm minimizing the divergence of B-vector and the net magnetohydrodynamic force, consequently a force-free solution would be reached if possible. We estimated two proxies to the magnetic helicity frequently used in literature: the force-free parameter {alpha}{sub z} and the current helicity term h{sub c{sub z}}. We show that both proxies are only qualitative indicators of the local twist as the magnetic field in the area under study significantly departs from a force-free configuration. The local twist shows significant values only at the borders of bright penumbral filaments with opposite signs on each side. These locations are precisely correlated to large electric currents. The average twist (and writhe) of penumbral structures is very small. The spines (dark filaments in the background) show a nearly zero writhe. The writhe per unit length of the intraspines diminishes with increasing length of the tube axes. Thus, the axes of tubes related to intraspines are less wrung when the tubes are more horizontal. As the writhe of the spines is very small, we can conclude that the writhe reaches only significant values when the tube includes the border of an intraspine.

79 ASTRONOMY AND ASTROPHYSICS↗

VERITAS OBSERVATIONS OF SIX BRIGHT, HARD-SPECTRUM FERMI-LAT BLAZARS

We report on VERITAS very high energy (VHE; E {>=} 100 GeV) observations of six blazars selected from the Fermi Large Area Telescope First Source Catalog (1FGL). The gamma-ray emission from 1FGL sources was extrapolated up to the VHE band, taking gamma-ray absorption by the extragalactic background light into account. This allowed the selection of six bright, hard-spectrum blazars that were good candidate TeV emitters. Spectroscopic redshift measurements were attempted with the Keck Telescope for the targets without Sloan Digital Sky Survey spectroscopic data. No VHE emission is detected during the observations of the six sources described here. Corresponding TeV upper limits are presented, along with contemporaneous Fermi observations and non-concurrent Swift UVOT and X-Ray Telescope data. The blazar broadband spectral energy distributions (SEDs) are assembled and modeled with a single-zone synchrotron self-Compton model. The SED built for each of the six blazars shows a synchrotron peak bordering between the intermediate- and high-spectrum-peak classifications, with four of the six resulting in particle-dominated emission regions.

79 ASTRONOMY AND ASTROPHYSICS↗

SPECTROSCOPIC OBSERVATIONS OF SN 2012fr: A LUMINOUS, NORMAL TYPE Ia SUPERNOVA WITH EARLY HIGH-VELOCITY FEATURES AND A LATE VELOCITY PLATEAU

We present 65 optical spectra of the Type Ia SN 2012fr, 33 of which were obtained before maximum light. At early times, SN 2012fr shows clear evidence of a high-velocity feature (HVF) in the Si II {lambda}6355 line that can be cleanly decoupled from the lower velocity ''photospheric'' component. This Si II {lambda}6355 HVF fades by phase -5; subsequently, the photospheric component exhibits a very narrow velocity width and remains at a nearly constant velocity of {approx}12,000 km s{sup -1} until at least five weeks after maximum brightness. The Ca II infrared triplet exhibits similar evidence for both a photospheric component at v Almost-Equal-To 12,000 km s{sup -1} with narrow line width and long velocity plateau, as well as an HVF beginning at v Almost-Equal-To 31,000 km s{sup -1} two weeks before maximum. SN 2012fr resides on the border between the ''shallow silicon'' and ''core-normal'' subclasses in the Branch et al. classification scheme, and on the border between normal and high-velocity Type Ia supernovae (SNe Ia) in the Wang et al. system. Though it is a clear member of the ''low velocity gradient'' group of SNe Ia and exhibits a very slow light-curve decline, it shows key dissimilarities with the overluminous SN 1991T or SN 1999aa subclasses of SNe Ia. SN 2012fr represents a well-observed SN Ia at the luminous end of the normal SN Ia distribution and a key transitional event between nominal spectroscopic subclasses of SNe Ia.

79 ASTRONOMY AND ASTROPHYSICS↗

Λ effect in the cosmological expansion of void

We investigate the dynamical effect of the cosmological constant Λ on a single spherical vacuum void evolving in the universe within a global solution of Newton-Friedmann models. As a result, the main characteristic is that the void expands with a huge initial burst up to match asymptotically the Hubble flow. The size of voids increases with Ω{sub o} and with Λ, which is interpreted as respectively by the gravitational attraction of borders from outside regions and by the gravitational repulsion of vacuum from the inner region. The Λ-effect on the kinematics intervenes significantly by amplifying the expansion rate at redshift z ∼ 1.7 for a background density parameter Ω{sub o} ∼ 0.3. For a class of parameters values, which corresponds in GR to spatially closed Friedmann models, it is interesting to note that a test particle in the inner region moves toward the border. Such a peculiar feature shows that the empty regions are swept out; which stands as a stability criterion.

79 ASTRONOMY AND ASTROPHYSICS↗

Characterization and correction of charge-induced pixel shifts in DECam

Interaction of charges in CCDs with the already accumulated charge distribution causes both a flux dependence of the point-spread function (an increase of observed size with flux, also known as the brighter/fatter effect) and pixel-to-pixel correlations of the Poissonian noise in flat fields. We describe these effects in the Dark Energy Camera (DECam) with charge dependent shifts of effective pixel borders, i.e. the Antilogus et al. (2014) model, which we fit to measurements of flat-field Poissonian noise correlations. The latter fall off approximately as a power-law r -2.5 with pixel separation r, are isotropic except for an asymmetry in the direct neighbors along rows and columns, are stable in time, and are weakly dependent on wavelength. They show variations from chip to chip at the 20% level that correlate with the silicon resistivity. The charge shifts predicted by the model cause biased shape measurements, primarily due to their effect on bright stars, at levels exceeding weak lensing science requirements. We measure the flux dependence of star images and show that the effect can be mitigated by applying the reverse charge shifts at the pixel level during image processing. Differences in stellar size, however, remain significant due to residuals at larger distance from the centroid.

79 ASTRONOMY AND ASTROPHYSICS↗

New detector for use in fast neutron radiography

We have developed and tested a new type detector for use in the fast neutron (FN) imaging radiography applications. FN radiography is generally used for nondestructive material testing, medical and biology applications, border patrol, transportation and cargo screening tasks. It is complementary to other types of radiography, providing additional information on light element content of the material samples. Distinct from other FN imagers presently known, our device implements a neutron-sensitive scintillator attached to a position-sensitive photomultiplier tube (PSPMT), and operates in an event-by-event readout mode, acquiring energy, timing, and pulse shape information for all detected radiation events. The information is used to help separate events of FN interactions in the scintillator from the background events caused by the electronics noise and by the other types of background radiation. Selection of pure fast neutron events in the final image allows us to achieve ultimate image contrast and resolution, as compared with other types of FN imaging devices operating most commonly in an integration mode, in which the detector?s dark noise and radiation background dilute the images. The detector performance for FN imaging application was tested using D-D neutron generator, designed and manufactured by Adelphi Technology, Inc. This essentially point-like neutron source operates in continuous mode producing up to 109 of 2.5 MeV neutrons per second. Samples made of metals plastic and other material were used to measure the detector resolution, efficiency and uniformity. Results of these tests are presented and discussed. Fig. 1 shows one of the test FN radiographic images obtained using the sample made of 11 styrene plastic strips. All strips are squares 4.8 x 4.8 mm2 with six different lengths 10 to 60 mm with 10 mm increment. [A] [B] [C] Fig. 1. [A]-layout of the test sample; [B]-raw FN shadow image of the sample; [C]-map of the plastic strips as they appear on the image, with measured FN absorption factor shown in percent. Both X and Y position resolution of the FN imaging detector are estimated to be less than 0.5 mm (sigma) based on the analysis of the edges of the strip shadows in the plot. Because this detector shows the fraction-of-a-millimeter resolution desirable for most of FN applications, and is built using radiation hard materials, we believe it could be a good alternative to other FN imaging systems based on CCD or solid state detectors. In addition, having a sub-nanosecond timing resolution, it is suitable for the time-of-flight energy-resolved FN imaging.

Popov, V.↗

Biodiversity and Global Health: Intersection of Health, Security, and the Environment

One of the biggest consequences of large-scale environmental change is the loss of biodiversity. Recent studies predict a loss of 1 million species in the near future. Biodiversity loss and land use change through anthropogenic disturbance are known to affect disease exposure, disease severity, and disease impacts. It is becoming increasingly clear that biodiversity loss will lead to an increase in infectious diseases in certain regions. Changes in biodiversity may contain important signatures for prediction of infectious diseases and outbreaks. Here, we argue that areas of high or rapid biodiversity loss will be critical to monitor under the umbrella of global health security. Global Health Security consists of the actions and activities required to reduce the impact of public health events in populations living in different geographic regions and across international borders. Like infectious diseases, climate change and other causes of environmental changes do not respect international borders and are becoming more widespread in all parts of the world. Here, the relationships among biodiversity, climate and environmental changes, and pathogen prevalence are dynamic, context dependent, and complex. Accounting for this complexity requires the inclusion of the environment sector, presently missing, when evaluating the potential of global health security actions for mitigating disease risks.

59 BASIC BIOLOGICAL SCIENCES↗

Geometrical meaning of two-qubit entanglement and its symmetries

For pure and mixed two-qubit states we present an analysis based on symmetries of vectors and matrices associated to the density operator. These symmetries are revealed by doing reflection operations on the vectors and the matrices by Cartesian planes. Then we consider states whose 4x4 matrices belong to the D-7 manifold class and introduce a new set of parameters. This procedure allows us to establish the Peres-Horodecki separability criterion in terms of a squared distance having a Minkowski metric. Thereafter, defining a phase space in terms of those parameters, we identify two regions, a cone and elsewhere. Separable states are represented by points located within the cone or on its surface (the border), while elsewhere the points stand for the entangled states. For a system evolving in time, if its state is initially entangled, then depending on the values of its parameters and on the nature of the interactions with the environment, the trajectory in the phase space may cross the border at a finite time, going from the entangledlike to the separablelike region and vice-versa. As a particular feature, crossings in one direction stand for the phenomenon of sudden death of entanglement, while crossings in the opposite direction hint for the sudden birth of entanglement. Our method dispenses with operations on the density matrix; it is sufficient to write the expressions directly in terms of matrix entries. Some illustrative examples are worked out.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Towards Polymer-Free, Femto-Second Laser-Welded Glass/Glass Solar Modules

This project explores the use of femto-second (fs) lasers to form glass-to-glass welds for hermetically sealed, polymer-free solar modules. Low iron solar glass coupons were welded together without the use of glass filler using a fs laser with dedicated optics to elongate the focal plane parallel to the incident beam. The resulting welds were then stress tested to failure to reveal the critical stress intensity factor, KIc. These values were used in a structural mechanics model of a 1 m by 2 m glass/glass module under a simulated static load test. The results show that the fs laser welds are strong enough for a suitably framed module to pass the IEC 61215 static load test with a load of 5400 Pa. Key to this finding is that the module must be framed and braced, and the glass must be ribbed to allow pockets for the cells and welds inside the border of the module. The result is a module design that is completely polymer-free, hermetically sealed, has improved thermal properties, and is easily recycled.

femto-second laser welded↗

Time Series Evaluation of Portal Monitor Data

Radiation portal monitors screen cargo and personal vehicle traffic at international border crossings to detect and interdict illicit sources which may be present in the commerce stream. One difficulty faced by RPM systems is the prospect of false alarms, or undesired alarms due to background fluctuation, or Naturally-Occurring Radioactive Material (NORM) sources in the commerce stream. In general, NORM alarms represent a significant fraction of the nuisance alarms at international border crossings, particularly with Polyvinyl-Toluene (PVT) RPM detectors, which have only very weak spectral differentiation capability. With PVT detectors, the majority of detected photon events fall within the Compton continuum of the material, allowing for very little spectral information to be preserved [1]. Previous work has shown that these detectors can be used for limited spectroscopy, utilizing around 8 spectral bins to further differentiate some NORM and other nuisance sources [2]. NaI based systems achieve much more detailed spectral resolution from each measurement of a source, but still combine all measurements over a vehicle's occupancy in order to arrive at a spectrum to be analyzed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

An Exploratory Risk Perception Study of Attitudes Toward Homeland Security Systems

Understanding the issues surrounding public acceptance of homeland security systems is important for balancing security needs and potential civil liberties infringements. A psychometric survey was used to measure attitudes regarding homeland security systems. Psychometric rating data were obtained from 182 respondents on psychological attributes associated with 12 distinct types of homeland security systems. An inverse relationship was observed for the overall rating attributes of acceptability and risk of civil liberties infringement. Principal components analysis yielded a two factor solution, with the rating scale loading pattern suggesting factors of Perceived Effectiveness and Perceived Intrusiveness. These factors also showed an inverse relationship. The 12 different homeland security systems showed significantly different scores on the rating scales and PCA factors, which were used to rank the systems in terms of overall acceptability. Difference scores for the rating scales and PCA factors were used to compute a single acceptability value reflecting the relative weight of risks and benefits. Of the 12 systems studied, airport screening, canine detectors and radiation monitoring at borders were found to be relatively acceptable, i.e., the perceived benefits for homeland security outweighed the perceived risks to civil liberties. Students rated several systems as more effective than professionals, but the overall pattern of results for both types of subjects was similar. The data suggest that risk perception research and the psychometric paradigm are useful approaches for quantifying attitudes regarding homeland security systems and policies, and can be used to anticipate potentially significant public acceptance issues.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Enhanced epidermal dose caused by localized electron contamination from lead cutouts used in kilovoltage radiotherapy

Purpose: To investigate and quantify electron contamination from the lead cutouts used in kilovoltage x-ray radiotherapy. Methods: The lead cutouts were modeled with the Monte Carlo EGSnrc user codes DOSXYZnrc and DOSRZnrc for x-ray beams ranging from 50 to 300 kV{sub p}. The results from the model were confirmed with Gafchromic film measurements. The model and measurements investigated the dose distribution with and without gladwrap shielding under the lead, and dose distributions with round, square, and serrated edge cutouts. Results: Large dose enhancement near the edges of the lead was observed due to electron contamination. At the epidermal/dermal border, there is double the dose at the edge of the lead compared to the central dose due to electron contamination for a 150 kV{sub p} beam and three times the dose for a 300 kV{sub p} beam. gladwrap shielding effectively removes the contaminant dose enhancement using ten and four layers for 300 and 150 kV{sub p} beams, respectively. Conclusions: The contaminant dose enhancement is undesirable as it could cause unnecessary erythema and hyperpigmentation at the border of the treated and untreated skin and lead to a poorer cosmetic outcome. The contamination is easily removed by gladwrap shielding placed under or around the lead cutout.

60 APPLIED LIFE SCIENCES↗

The use of zeolites to generate PET phantoms for the validation of quantification strategies in oncology

Purpose: In recent years, segmentation algorithms and activity quantification methods have been proposed for oncological {sup 18}F-fluorodeoxyglucose (FDG) PET. A full assessment of these algorithms, necessary for a clinical transfer, requires a validation on data sets provided with a reliable ground truth as to the imaged activity distribution, which must be as realistic as possible. The aim of this work is to propose a strategy to simulate lesions of uniform uptake and irregular shape in an anthropomorphic phantom, with the possibility to easily obtain a ground truth as to lesion activity and borders. Methods: Lesions were simulated with samples of clinoptilolite, a family of natural zeolites of irregular shape, able to absorb aqueous solutions of {sup 18}F-FDG, available in a wide size range, and nontoxic. Zeolites were soaked in solutions of {sup 18}F-FDG for increasing times up to 120 min and their absorptive properties were characterized as function of soaking duration, solution concentration, and zeolite dry weight. Saturated zeolites were wrapped in Parafilm, positioned inside an Alderson thorax-abdomen phantom and imaged with a PET-CT scanner. The ground truth for the activity distribution of each zeolite was obtained by segmenting high-resolution finely aligned CT images, on the basis of independently obtained volume measurements. The fine alignment between CT and PET was validated by comparing the CT-derived ground truth to a set of zeolites' PET threshold segmentations in terms of Dice index and volume error. Results: The soaking time necessary to achieve saturation increases with zeolite dry weight, with a maximum of about 90 min for the largest sample. At saturation, a linear dependence of the uptake normalized to the solution concentration on zeolite dry weight (R{sup 2}= 0.988), as well as a uniform distribution of the activity over the entire zeolite volume from PET imaging were demonstrated. These findings indicate that the {sup 18}F-FDG solution is able to saturate the zeolite pores and that the concentration does not influence the distribution uniformity of both solution and solute, at least at the trace concentrations used for zeolite activation. An additional proof of uniformity of zeolite saturation was obtained observing a correspondence between uptake and adsorbed volume of solution, corresponding to about 27.8% of zeolite volume. As to the ground truth for zeolites positioned inside the phantom, the segmentation of finely aligned CT images provided reliable borders, as demonstrated by a mean absolute volume error of 2.8% with respect to the PET threshold segmentation corresponding to the maximum Dice. Conclusions: The proposed methodology allowed obtaining an experimental phantom data set that can be used as a feasible tool to test and validate quantification and segmentation algorithms for PET in oncology. The phantom is currently under consideration for being included in a benchmark designed by AAPM TG211, which will be available to the community to evaluate PET automatic segmentation methods.

60 APPLIED LIFE SCIENCES↗

SU-E-J-34: Clinical Evaluation of Targeting Accuracy and Tractogrphy Delineation of Radiosurgery

Purpose: Focal radiosurgery is a common treatment modality for trigeminal neuralgia (TN), a neuropathic facial pain condition. Assessment of treatment effectiveness is primarily clinical, given the paucity of investigational tools to assess trigeminal nerve changes. The efficiency of radiosurgery is related to its highly precise targeting. We assessed clinically the targeting accuracy of radiosurgery with Gamma knife. We hypothesized that trigeminal tractography provides more information than 2D-MR imaging, allowing detection of unique, focal changes in the target area after radiosurgery. Methods: Sixteen TN patients (2 females, 4 male, average age 65.3 years) treated with Gamma Knife radiosurgery, 40 Gy/50% isodose line underwent 1.5Tesla MR trigeminal nerve . Target accuracy was assessed from deviation of the coordinates of the target compared with the center of enhancement on post MRI. Radiation dose delivered at the borders of contrast enhancement was evaluated Results: The median deviation of the coordinates between the intended target and the center of contrast enhancement was within 1mm. The radiation doses fitting within the borders of the contrast enhancement the target ranged from 37.5 to 40 Gy. Trigeminal tractography accurately detected the radiosurgical target. Radiosurgery resulted in 47% drop in FA values at the target with no significant change in FA outside the target, suggesting that radiosurgery primarily affects myelin. Tractography was more sensitive, since FA changes were detected regardless of trigeminal nerve enhancement Conclusion: The median deviation found in clinical assessment of gamma knife treatment for TN Is low and compatible with its high rate of efficiency. DTI parameters accurately detect the effects of focal radiosurgery on the trigeminal nerve, serving as an in vivo imaging tool to study TN. This study is a proof of principle for further assessment of DTI parameters to understand the pathophysiology of TN and treatment effects.

60 APPLIED LIFE SCIENCES↗

SU-E-T-567: A Three-Field Mono-Isocentric Inverse Treatment Planning Method for the Patients with Larger Breasts

Purpose: The purpose of this study is to develop a three-field monoisocentric inverse breast treatment planning technique without the use of half-beam block. Methods: Conventional three-field breast treatment with supraclavicular half-beam blocked requires two isocenters when the breast is too large to be contained within half-beam. The inferior border of the supraclavicular field and superior borders of the breast fields are matched on patient's skin with the light field. This method causes a large dose variation in the matching region due to daily setup uncertainties and requires a longer treatment setup time. We developed a three-field mono-isocentric planning method for the treatment of larger breasts. The three fields share the same isocenter located in the breast. Beam matching is achieved by rotating collimator, couch and gantry. Furthermore, we employed a mixed open-IMRT inverse optimization method to improve dose uniformity and coverage. Results: Perfect geometric beam matching was achieved by rotating couch, collimator and gantry together. Treatment setup time was significantly reduced without light-field matching during treatment deliveries. Inverse mixed open-IMRT optimization method achieved better dose uniformity and PTV coverage while keeping sufficient air flash to compensate setup and breast shape changes in daily treatments. Conclusion: By eliminating light field matching, the three-field mono-isocentric treatment method can significantly reduce setup time and uncertainty for large breast patients. Plan quality is further improved by inverse IMRT planning.

60 APPLIED LIFE SCIENCES↗