Search NASA⌕ Search

SEARCH · Search NASA

Results for “building energy data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Characterization and Analysis of the Energy-Reporting Accuracy of Connected Devices

Emerging energy-efficient building systems increasingly exhibit greater functionality, often requiring multiple operating modes (e.g. white-tunability for lighting products and data traffic for devices with networked, integrated sensors). This increased functionality makes energy consumption estimates more complex. Given that these functions consume energy, the energy performance of such building systems is dependent on what operating modes they use and how much time they spend in each mode. Devices and systems that can report their own energy consumption mitigate this energy-performance uncertainty. This study explores the energy-reporting accuracy of market-available connected electrical outlets. The study considers two residential-market products (five units each, one outlet per unit) and three commercial-market products (two units each, 18 to 24 outlets per unit) with the ability to report power drawn and/or energy consumed by devices connected to their receptacles. The products were purchased through typical market channels. Pacific Northwest National Laboratory (PNNL) conducted testing in December 2018 at its Connected Lighting Test Bed (CLTB), using a custom-developed test setup and method adapted from industry standards. The setup collected energy-consumption data reported by the outlet devices under test (DUTs) at one-minute intervals and compared that data with measurements taken by a reference meter over a range of test conditions. The residential products reported power draw but not interval or cumulative energy consumption. The commercial products reported both power draw and cumulative energy consumption. Relative reporting error (RRE) was calculated for all measurements, and analysis of the results revealed variations across devices and test conditions. The total number of measurements (50 for each residential product, 60 for each commercial product) offers an appreciable comparison of performance at the make/model level. The average RRE of the residential products derived from reported power draw was -0.02% and -1.20%. The average RRE for two of the three the commercial products derived from reported power draw was worse than those of the residential products (-2.40%, -2.72%, -0.36%). The internal integration of power over time, used to calculate cumulative energy consumption, typically occurs at current and voltage sampling rates much higher than once per minute. This suggests that the average commercial-product RRE derived from reported energy consumption should be very consistent and better than performance based on reported power draw. However, the RRE derived from reported energy consumption varied significantly across the three makes of commercial-market products and was uniformly less accurate than performance based on reported power draw. Subsequent analysis identified a number of root causes for this decrease in performance, most of which were related to reporting resolution. The goals of this study are to generate awareness of building systems capable of reporting their own energy consumption, further interest in the value of energy data for a variety of uses, draw attention to how the accuracy of reported metrics can be characterized, and quantify the performance variation found in marketavailable products. The results of this study and subsequent related work may be relevant to stakeholders in industry-specification and standards-development organizations. The methods this study employs could inform test and measurement procedures and performance classifications for connected outlets, lighting products, and other building systems capable of reporting their own energy consumption. The study concludes with stakeholder recommendations, including the following: • Energy-reporting device and system manufacturers developing products that report energy consumption should characterize the accuracy of reported metrics using a reference meter calibrated by an independent laboratory that was accredited by an ILAC MRA signatory (and whose scope of accreditation explicitly covers energy measurement), and should include this information on product data sheets. • Standards and specification development organizations should develop application-specific performance classifications that end users can understand and relate to their energy-data use needs (e.g., 2% accuracy class for utility streetlight energy billing needs, or 10% accuracy class for ESCO performance verification needs). • Current or potential owners, operators, and specifiers of energy-reporting building systems should rigorously analyze the dependency of current and planned energy-data use cases on accuracy, noting in particular the dependence (or lack thereof) on relative vs. absolute accuracy, and on trueness vs. precision (i.e., repeatability), and should communicate use-case needs to industry standards and specification organizations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Characterization and Analysis of the Energy-Reporting Accuracy of Connected Devices

Emerging energy-efficient building systems increasingly exhibit greater functionality, often requiring multiple operating modes (e.g. white-tunability for lighting products and data traffic for devices with networked, integrated sensors). This increased functionality makes energy consumption estimates more complex. Given that these functions consume energy, the energy performance of such building systems is dependent on what operating modes they use and how much time they spend in each mode. Devices and systems that can report their own energy consumption mitigate this energy-performance uncertainty. This study explores the energy-reporting accuracy of market-available connected electrical outlets. The study considers two residential-market products (five units each, one outlet per unit) and three commercial-market products (two units each, 18 to 24 outlets per unit) with the ability to report power drawn and/or energy consumed by devices connected to their receptacles. The products were purchased through typical market channels. Pacific Northwest National Laboratory (PNNL) conducted testing in December 2018 at its Connected Lighting Test Bed (CLTB), using a custom-developed test setup and method adapted from industry standards. The setup collected energy-consumption data reported by the outlet devices under test (DUTs) at one-minute intervals and compared that data with measurements taken by a reference meter over a range of test conditions. The residential products reported power draw but not interval or cumulative energy consumption. The commercial products reported both power draw and cumulative energy consumption. Relative reporting error (RRE) was calculated for all measurements, and analysis of the results revealed variations across devices and test conditions. The total number of measurements (50 for each residential product, 60 for each commercial product) offers an appreciable comparison of performance at the make/model level. The average RRE of the residential products derived from reported power draw was -0.02% and -1.20%. The average RRE for two of the three the commercial products derived from reported power draw was worse than those of the residential products (-2.40%, -2.72%, -0.36%). The internal integration of power over time, used to calculate cumulative energy consumption, typically occurs at current and voltage sampling rates much higher than once per minute. This suggests that the average commercial-product RRE derived from reported energy consumption should be very consistent and better than performance based on reported power draw. However, the RRE derived from reported energy consumption varied significantly across the three makes of commercial-market products and was uniformly less accurate than performance based on reported power draw. Subsequent analysis identified a number of root causes for this decrease in performance, most of which were related to reporting resolution. The goals of this study are to generate awareness of building systems capable of reporting their own energy consumption, further interest in the value of energy data for a variety of uses, draw attention to how the accuracy of reported metrics can be characterized, and quantify the performance variation found in marketavailable products. The results of this study and subsequent related work may be relevant to stakeholders in industry-specification and standards-development organizations. The methods this study employs could inform test and measurement procedures and performance classifications for connected outlets, lighting products, and other building systems capable of reporting their own energy consumption. The study concludes with stakeholder recommendations, including the following: • Energy-reporting device and system manufacturers developing products that report energy consumption should characterize the accuracy of reported metrics using a reference meter calibrated by an independent laboratory that was accredited by an ILAC MRA signatory (and whose scope of accreditation explicitly covers energy measurement), and should include this information on product data sheets. • Standards and specification development organizations should develop application-specific performance classifications that end users can understand and relate to their energy-data use needs (e.g., 2% accuracy class for utility streetlight energy billing needs, or 10% accuracy class for ESCO performance verification needs). • Current or potential owners, operators, and specifiers of energy-reporting building systems should rigorously analyze the dependency of current and planned energy-data use cases on accuracy, noting in particular the dependence (or lack thereof) on relative vs. absolute accuracy, and on trueness vs. precision (i.e., repeatability), and should communicate use-case needs to industry standards and specification organizations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Miscellaneous Electric Loads: Characterization and Energy Savings Potential

Over time, miscellaneous electric loads (MELs) are expected to increase both in magnitude and share of residential and commercial building energy consumption. This trend is most apparent in North America, but it is also occurring in Japan and Europe. However, the contribution of MELs to building energy use is not currently well understood, both because the products in this category are transforming rapidly and the definition and classification of MELs is ambiguous. This study estimated the national energy consumption of 36 MELs using best-available data and found them to comprise 12% of delivered electricity to the U.S. residential and commercial building sectors. If 26 of these MELs were replaced with the most energy-efficient product models available on the market, their energy consumption could be halved to 6% of delivered electricity. National energy models will better account for building energy consumption by incorporating the MELs data collected and analyzed for this study, leading to improved policy decisions.

Miscellaneous electric loads, Plug loads, Taxonomy↗

Seminar 44, Innovative and New Ideas: BAS Best Practices for O&M Success Coaching Operators for Effective Use of Data

Regardless of a building’s inherent energy efficiency, changes in building operator behavior reduces building energy consumption by 14% on average. Giving operators readily available and easily digestible data regarding the performance of their HVAC systems increases the likelihood of energy saving actions. Many Building Automations Systems do not excel at creating user-friendly time series trend charts. This presentation presents examples of a solution to this issue developed under an award by the Department of Energy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

TPSAS-NF1676L-27534-DND

This presentation describes the preparation, validation and provision of MERRA-2 data products to the building industry for use in energy efficient designs, building codes and monitoring energy efficiency. It highlights efforts to use MERRA-2 surface meteorological data products for the derivation of quantities relevant to the energy and building industry such as heating and cooling degree days and building climate zones on a global basis for the past 30 years. A difference of the zones from the first 15 years and last 30 years shows that warming zones are creeping northward. The talk also presents work provide similar parameters for building energy performance assessment requiring data products closer to real time.

Paul W Stackhouse, Jr↗

Updated U.S. Low-Temperature Heating and Cooling Demand by County and Sector

This dataset includes U.S. low-temperature heating and cooling demand at the county level in major end-use sectors: residential, commercial, manufacturing, agricultural, and data centers. Census division-level end-use energy consumption, expenditure, and commissioned power database were dis-aggregated to the county level. The county-level database was incorporated with climate zone, numbers of housing units and farms, farm size, and coefficient of performance (COP) for heating and cooling demand analysis. This dataset also includes a paper containing a full explanation of the methodologies used and maps. Residential data were updated from the latest Residential Energy Consumption Survey (RECS) dataset (2015) using 2020 census data. Commercial data were baselined off the latest Commercial Building Energy Consumption Survey (CBECS) dataset (2012). Manufacturing data were baselined off the latest Manufacturing Energy Consumption Survey (MECS) dataset (2021).

15 GEOTHERMAL ENERGY↗

AlphaBuilding - Synthetic Buildings Operation Dataset

This is a synthetic building operation dataset which includes HVAC, lighting, miscellaneous electric loads (MELs) system operating conditions, occupant counts, environmental parameters, end-use and whole-building energy consumptions at 10-minute intervals. The data is created with 1395 annual simulations using the U.S. DOE detailed medium-sized reference office building, and 30 years' historical weather data in three typical climates including Miami, San Francisco, and Chicago. Three energy efficiency levels of the building and systems are considered. Assumptions regarding occupant movements, occupants' diverse temperature preferences, lighting, and MELs are adopted to reflect realistic building operations. A semantic building metadata schema - BRICK, is used to store the building metadata. The dataset is saved in a 1.2 TB of compressed HDF5 file. This dataset can be used in various applications, including building energy and load shape benchmarking, energy model calibration, evaluation of occupant and weather variability and their influences on building performance, algorithm development and testing for thermal and energy load prediction, model predictive control, policy development for reinforcement learning based building controls.

AlphaBuilding↗

Spatial Impacts of Electric Vehicle Charging on Power Grid Stability: A Downtown Atlanta Case Study

The rapid increase in electric vehicle (EV) charging demand poses a potential risk to power grid stability, particularly as the spatial distribution of this demand remains underexplored. Existing research often focuses on technical optimization models while overlooking the geographic and human dynamics that affect energy consumption. This study addresses this gap by incorporating mobility data to estimate both building energy use and EV charging demand while also considering geographic factors for a better understanding of grid load. Using agent-based simulations and the Open-Source Distribution System Simulator, the study evaluates the effect of various EV penetration scenarios on grid voltage and unbalance. The results show that, although voltage remains within acceptable limits at lower EV penetration rates, significant voltage drop and unbalance occur as EV penetration exceeds 40%, particularly in residential areas with high charging demand. This study offers a framework for integrating spatial analysis and mobility data in power network simulations, providing insights for future EV infrastructure planning.

Pan, Melrose [ORNL] (ORCID:000000031627448X)↗

Optimizing Facility Operations by Applying Machine Learning to the Army Reserve Enterprise Building Control System (Final Report)

Thousands of U.S. Department of Defense (DoD) buildings have building automation systems (BASs) and/or advanced meters. Although these systems have a wealth of data, performance optimization requires time and expertise to review and act on that information. Machine learning (ML) can provide automated and actionable insights to controls operators. This demonstration implemented proven ML methods on the Army Reserve Enterprise Building Control System. ML refers to algorithms that “learn” from data and improve their performance on a given task over time. In the buildings domain these tasks range from predicting future energy consumption, to identifying operational issues before faults occur, to optimizing control decisions. To learn, ML requires input data, which – for buildings – typically consists of instrument data such as energy consumption data and subsystem controls information such as set-point temperatures, and context data consisting of information such as the physical location of the building, the area of the building, and the weather. ML models use the relationships learned from the input data to make predictions with new, previously unseen, data. The team was able to investigate and successfully implement the following ML use cases: labeling consumption data as anomalous or non-anomalous; baseline whole-building load prediction (unknown fault status); fault detection (validation not possible); and site prioritization for energy-related projects. Due to the constraints of the project, interventions were not able to be implemented during the demonstration; therefore, assessments of operational cost savings and maintenance avoided could not be performed. The project has been presented at two leading national building conferences and two additional publications to peer-reviewed journals are currently in preparation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Grid-Interactive Building Solutions: MelRok Energy IOT Touch Gateway

This fact sheet describes a grid-interactive efficient building technology that is undergoing field validation tests through DOE's National Labs. It summarizes the technology application (MelRok's Energy IOT Touch), the parameters of the demonstration, and the characteristics of the field validation site.

grid-interactive efficient buildings, GEB, technol↗

Grid-Interactive Building Solutions: Synapse from Kinetic Buildings

This fact sheet describes a grid-interactive efficient building technology that is undergoing field validation tests through DOE's National Labs. It summarizes the technology application (Synapse software from Kinetic Buildings) and the characteristics of the field validation site.

grid-interactive efficient buildings, GEB, technol↗

Data-Driven Co-optimization of Energy Efficiency and Indoor Environmental Quality in Commercial Buildings

In this paper, we use publicly available data of a highly instrumented building to estimate how zonal temperature and carbon dioxide (CO2) concentration are related to some key operational and environmental measurements. Subsequently, we have developed, simulated, and evaluated an optimization framework for minimizing the energy consumption of the central heating, ventilation and air conditioning (HVAC) unit while meeting zonal temperature and indoor air quality (IAQ) standards. Finally, we have evaluated the achievable energy savings for our proposed approach as compared to a baseline approach and reported significant savings potential.

Naqvi, Syed Ahsan Raza↗

Buildings Sector Scenarios: Demand-side data to support energy system planning in the United States

The US energy system is in a period of high uncertainty about load growth, its implications for the energy generation mix, and downstream impacts on customer energy costs. In this context, there is a need for comprehensive, credible, and readily-customized projections of energy demand to ensure that planning decisions account for end-use management opportunities to improve system reliability and affordability. Here we introduce the Buildings Sector Scenarios (BSS) dataset, which includes a benchmark suite of such projections for the buildings sector — a key source of energy consumption, peak electricity demand, and consumer energy expenditures. The dataset contains projections through 2050 covering the contiguous United States (CONUS) resolved down to the county, hourly level by sector and end use for electricity demand and to the state, annual level by sector and end use for non-electric fuels. We summarize the BSS analysis workflow and the tools and datasets that support it, document key BSS scenario inputs and modeling assumptions, and outline BSS scenario outputs. We assess the technical quality of the dataset against historical surveys and projected estimates of buildings sector demand. Finally, we provide guidance on how stakeholders can access, use, and reproduce the dataset, and/or create new scenarios to explore their own analysis questions.

Langevin, Jared↗

Changes in Characteristics of Future Climate Across the U.S.: Time Series Analysis of Climate Model Data by NASA POWER

NASA’s Prediction of Worldwide Energy Resource (POWER) project facilitates the use of NASA Earth Science data holdings within the energy, agricultural, and building heating/cooling design industries. POWER packages solar and meteorological data at various temporal levels from several NASA projects in a user friendly GIS-enabled web services system (https://power.larc.nasa.gov). Data users can access these data either through an intuitive data viewer, image services fully integrable with GIS analysis, connections in the cloud through an Amazon Web Services S3 Bucket, or fully customizable access through an API. Data provided by POWER has been used to remotely monitor solar array fields and integrated in a sizing tool for off-grid solar and storage systems. POWER data has also been coupled with key building decision tools to support design and retrofitting of building energy systems for energy efficiency and reduction of greenhouse gases. POWER is now developing capabilities to provide time series of the projected future evolution of surface quantities important to future energy production and use, such as heating/cooling degree days, temperature, wind speed, and downwelling solar flux. We present here a range of possible future changes in these quantities at locations throughout the continental United States. We show how both average and extreme values of the quantities will evolve from present-day to future climate conditions. We plan to provide these projections for users in the energy and sustainable energy communities.

Bradley M. Hegyi↗

City and County Energy Profiles

The City and County Energy Profiles lookup table provides modeled electricity and natural gas consumption and expenditures, on-road vehicle fuel consumption, vehicle miles traveled, and associated emissions for each U.S. city and county. Please note this data is modeled and more precise data may be available from regional, state, or other sources. The modeling approach for electricity and natural gas is described in Sector-Specific Methodologies for Subnational Energy Modeling: https://www.nrel.gov/docs/fy19osti/72748.pdf. This data is part of a suite of state and local energy profile data available at the "State and Local Energy Profile Data Suite" link below and builds on Cities-LEAP energy modeling, available at the "EERE Cities-LEAP Page" link below. Examples of how to use the data to inform energy planning can be found at the "Example Uses" link below.

Array↗

City and County Vehicle Inventories

This light-duty vehicle inventory dataset provides information on vehicle registrations by vehicle type (car vs. truck), fuel type, and model year showing the changes in adoption trends over time and average fuel economies. This data is part of a suite of state and local energy profile data available at the "State and Local Energy Profile Data Suite" link below and builds on Cities-LEAP energy modeling, available at the "EERE Cities-LEAP Page" link below. Examples of how to use the data to inform energy planning can be found at the "Example Uses" link below.

Alternative Fuel↗

Refining seasonal performance metrics for room air-conditioning in emerging markets: Integrating building simulations with real-world equipment performance data

Buildings significantly impact worldwide energy consumption, emphasizing the need to reduce the cooling energy demand, especially in warm climates. Minimum energy performance standards (MEPS) and seasonal performance metrics such as the Cooling Seasonal Performance Factor (CSPF) are crucial for improving room air conditioning (RAC) efficiency. However, challenges remain, particularly in emerging markets like Brazil, where seasonal performance metrics have recently been introduced. This study assesses the factors influencing country-level seasonal efficiency metrics and proposes a framework to refine these calculations by considering local climates and expected RAC usage in real-world households via building simulations. Key considerations include outdoor air temperature binning for different climates, RAC usage patterns (i.e., daytime and nighttime usages), envelope thermal performance of households, and urban heat island (UHI) effects. The results reveal that CSPF values can vary significantly based on climate conditions, with observed CSPF ranging from 4.10 to 11.59 Wh/Wh across 577 Brazilian climates. The inclusion of UHI effects led to a reduction in CSPF values by up to 29% during nighttime operations in hot urban areas. Additionally, building envelope efficiency showed contrasting impacts on RAC performance, with CSPFs reaching up to 15.35 Wh/Wh under specific optimized conditions. These findings highlight the need for transparent policymaking in RAC performance databases, facilitating the application of approaches like those proposed in this study and supporting diverse stakeholders in decision-making.

Bavaresco, Mateus↗