Search NASA⌕ Search

SEARCH · Search NASA

Results for “calibration source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Radiometric calibrations of portable sources in the vacuum ultraviolet

The primary UV radiometric calibration standards of the Atomic and Plasma Radiation Division of the NBS are the hydrogen arc and the blackbody line arc. The secondary standards are the argon mini- and maxiarcs, and the deuterium arc lamp. Calibration methods involving both spectral radiance and irradiance, as well as the evaluation of their uncertainties, are discussed. Attention is given to the establishment of an irradiance scale, and the absolute spectral irradiance, measured as a function of wavelength, at a 50-cm distance from the field aperture for five different continuum sources.

Klose, Jules Z.↗

The DECADE cosmic shear project II: photometric redshift calibration of the source galaxy sample

We present the photometric redshift characterization and calibration for the Dark Energy Camera All Data Everywhere (DECADE) weak lensing dataset: a catalog of 107 million galaxies observed by the Dark Energy Camera (DECam) in the northern Galactic cap. The redshifts are estimated from a combination of wide-field photometry, deep-field photometry with associated redshift estimates, and a transfer function between the wide field and deep field that is estimated using a source injection catalog. We construct four tomographic bins for the galaxy catalog, and estimate the redshift distribution, $n(z)$, within each one using the Self-organizing Map Photo-Z (SOMPZ) methodology. Our estimates include the contributions from sample variance, zeropoint calibration uncertainties, and redshift biases, as quantified for the deep-field dataset. The total uncertainties on the mean redshifts are $σ_{\langle}$$_z$$_{\rangle} ≈ 0.01$. The SOMPZ estimates are then compared to those from the clustering redshift method, obtained by cross-correlating our source galaxies with galaxies in spectroscopic surveys, and are shown to be consistent with each other.

Anbajagane, D. [Univ. of Chicago, IL (United State↗

Absolute flux density calibrations of radio sources: 2.3 GHz

A detailed description of a NASA/JPL Deep Space Network program to improve S-band gain calibrations of large aperture antennas is reported. The program is considered unique in at least three ways; first, absolute gain calibrations of high quality suppressed-sidelobe dual mode horns first provide a high accuracy foundation to the foundation to the program. Second, a very careful transfer calibration technique using an artificial far-field coherent-wave source was used to accurately obtain the gain of one large (26 m) aperture. Third, using the calibrated large aperture directly, the absolute flux density of five selected galactic and extragalactic natural radio sources was determined with an absolute accuracy better than 2 percent, now quoted at the familiar 1 sigma confidence level. The follow-on considerations to apply these results to an operational network of ground antennas are discussed. It is concluded that absolute gain accuracies within + or - 0.30 to 0.40 db are possible, depending primarily on the repeatability (scatter) in the field data from Deep Space Network user stations.

Freiley, A. J.↗

The Use of Transfer Radiometers in Validating the Visible through Shortwave Infrared Calibrations of Radiance Sources Used by Instruments in NASA's Earth Observing System

The detection and study of climate change over a time frame of decades requires successive generations of satellite, airborne, and ground-based instrumentation carefully calibrated against a common radiance scale. In NASA s Earth Observing System (EOS) program, the pre-launch radiometric calibration of these instruments in the wavelength region from 400 nm to 2500 nm is accomplished using internally illuminated integrating spheres and diffuse reflectance panels illuminated by irradiance standard lamps. Since 1995, the EOS Calibration Program operating within the EOS Project Science Office (PSO) has enlisted the expertise of national standards laboratories and government and university metrology laboratories in an effort to validate the radiance scales assigned to sphere and panel radiance sources by EOS instrument calibration facilities. This state-of-the-art program has been accomplished using ultra-stable transfer radiometers independently calibrated by the above participating institutions. In ten comparisons since February 1995, the agreement between the radiance measurements of the transfer radiometers is plus or minus 1.80% at 411 nm, plus or minus 1.31% at 552.5 nm, plus or minus 1.32% at 868.0 nm, plus or minus 2.54% at 1622nm, and plus or minus 2.81% at 2200nm (sigma =1).

Butler, James J.↗

Advanced Energy Scale Correction Techniques for the X-ray Transition Edge Sensors of the Athena mission

The X-ray Integral Field Unit (X-IFU) onboard the future European X-ray telescope Athena will be the first space instrument carrying an array of more than a thousand transition edge sensors. One of the key challenges of the X-IFU is the measurement of narrow X-ray atomic lines to determine velocity shifts at an unprecedented level of accuracy. For this reason, the energy scale of the instrument needs to be known with extreme accuracy, of 0.4 eV (1σ) up to 7 keV. The energy scale will be measured on the ground through a dedicated calibration campaign using fiducial X-ray sources. Though calibrated, the energy scale is extremely sensitive to the environmental conditions around the TES array, and drifts in the readout chain electronics. Uncorrected, the energy scale can naturally drift up to hundreds of eVs. Changes of the TES gain will be monitored via onboard X-ray calibration sources, and the energy scale will be corrected either per pixel, or within a small groups of pixels. Although simulations show that a 0.4 eV level can be achieved, the very high accuracy required by the X-IFU calls for experimental validation. A dedicated measurement campaign has been performed by NASA Goddard Space Flight Center to characterize the energy scale of a prototype kilo-pixel array of X-IFU-representative TESs. The analysis of the data demonstrated the ability to correct for various drifts using two fiducial lines to track the temporal gain variation. In this paper, we propose to extend this study on the same data set by investigating multi-parameter correction techniques based on both the pulse-height of the fiducial line and the prepulse baseline level, using the knowledge of the TES energy scale at reference temperature/magnetic field set points acquired on the ground. Investigations on the co-adding of pixels to perform a joint correction over pools of pixels is also explored.

79 ASTRONOMY AND ASTROPHYSICS↗

A radio telescope for the calibration of radio sources at 32 gigahertz

A 1.5-m-diameter radio telescope has been designed, developed, and assembled to directly measure the flux density of radio sources in the 32-GHz (Ka-band) frequency band. The main goal of the design and development was to provide a system that could yield the greatest absolute accuracy yet possible with such a system. The accuracy of the measurements have a heritage that is traceable to the National Institute of Standards and Technology. At the present time, the absolute accuracy of flux density measurements provided by this telescope system, during Venus observations at nearly closest approach to Earth, is plus or minus 5 percent, with an associated precision of plus or minus 2 percent. Combining a cooled high-electron mobility transistor low-noise amplifier, twin-beam Dicke switching antenna, and accurate positioning system resulted in a state-of-the-art system at 32 GHz. This article describes the design and performance of the system as it was delivered to the Owens Valley Radio Observatory to support direct calibrations of the strongest radio sources at Ka-band.

Gatti, M. S.↗

Vacuum-Ultraviolet Intensity-Calibration Standard

Portable light source enables calibration of spectrometers. Vacuum Ultraviolet Light (40 to 200 nm) produced in electron-impact emission chamber by leading beam of gas across electron beam. Photons observed at right angles to electron-beam axis. Previously, there were blackbody standards in visible and near ultraviolet, but no intensity-calibration standards in VUV.

Ajello, J. M.↗

Helium metastable density determination in the COST reference source by absolutely calibrated optical emission spectroscopy

Helium metastable densities in the COST Reference Microplasma Jet are estimated for a variety of He/N2 admixtures and dissipated powers by applying a collisional-radiative model to absolutely calibrated optical emission spectroscopy measurements. This is accomplished by delineating the excitation mechanisms that result in the N2(C–B) and N2+(B–X) emission bands, the latter of which is strongly coupled to the presence of helium metastables. A number of other plasma parameters are established and discussed for each operating condition including the electron energy distribution function, reduced electric field, rate constants, and electron density. With these parameters, the reaction rates for the primary ionization pathways are also calculated, emphasizing the importance of helium metastables for discharge sustainment. Good agreement with the existing literature is found for most plasma parameters and for helium metastable densities, in particular. A clear [N2]−1 relationship between the nitrogen concentration and density of helium metastables is demonstrated, as has been identified in previous studies in analogous atmospheric pressure plasma jets. This validates the efficacy of this optical technique for determining helium metastable densities and establishes it as a viable, and in many cases, more accessible alternative to other means of quantifying helium metastables in low-temperature plasmas.

Physics↗

Mapping and imaging ionizing radiation in two and three dimensions

A two-dimensional imaging system and a two-dimensional or three-dimensional optical tomographic mapping system, each employing gas scintillation induced by ionizing radiation, i.e., radioluminescence, and corresponding methods, are disclosed. The systems may employ one or more cameras and corresponding UV filters (potentially solar blind filters) for imaging a radioluminescent scene. For two-dimensional or three-dimensional mapping, the resultant UV images are spatially registered with one another and then reconstructed to form a three-dimensional tomographic map of the ionizing radiation. The two-dimensional map is a plane of the three-dimensional map. The UV images may be spatially registered by using a reference source, optionally, a calibrated reference source allowing dosimetry calculations for the ionizing radiation. Molecular nitrogen is the primary candidate for the radioluminescent gas, though a controlled ambient in a chamber of nitric oxide, argon, krypton, or xenon may be employed. The reconstruction process employs an algebraic reconstruction technique or an Abel inversion.

Bentz, Brian Z.↗

Intercalibration of Meteorological Satellite Imagers Using VIRS, ATSR-2 and MODIS

Global retrievals of surface, cloud and radiative properties from geostationary (GEO) and low-Earth-orbit (LEO) meteorological satellites require accurate calibration of their imagers. An accurate and consistent calibration increases the reliability and effectiveness of long-term monitoring of climate changes. More emphasis has been placed on calibrating the thermal infrared (IR) channel. The lack of on-board calibration in the visible (VIS) channel has prompted efforts to characterize the degradation of the VIS sensor using vicarious post-launch calibration techniques that measure bright stable desert targets from space and aircraft or using satellite-to-satellite normalizations. While such inter-calibrations are valuable and widely used, the lack of a well-characterized calibration reference source and the lengthy time delay between updates have minimized their effectiveness in climate monitoring. To address these shortcomings, this paper examines the use of research satellite imagers to provide stable calibration references for the visible (VIS, approximately 0.65 micrometers) channels and develops a method for rapid intercalibration of existing satellites. Calibration coefficients are determined for the Geostationary Operational Environmental Satellites (GOES-8 to GOES-10), Geostationary Meteorological Satellite (GMS-5), Meteosat-7, and the NOAA-14 Advanced Very High Resolution Radiometer (AVHRR). As a reference calibration source, this technique uses the self-calibrating sensors on the Tropical Rainfall Measuring Mission (TRMM) Visible Infrared Radiometers (VIRS) or the ERS-2 Along Track Scanning Radiometer (ATSR-2). GOES-8 is calibrated with VIRS and then its calibration is transferred to other GEO or LEO satellites. The absolute accuracy of this technique relies on the assumption that the on-board calibration is stable and well maintained. Minnis et al. assessed the VIRS calibration using comparisons with other self-calibrated satellite sensors including the broadband Clouds and Earth's Radiant Energy System (CERES) scanners, the ERS-2 Along Track Scanning Radiometer (ATSR-2), and the Terra Moderate-resolution Imaging Spectrometer (MODIS). Thus, the VIRS data can be confidently used as the initial reference source.

Nguyen, Louis↗

Evaluation of S190A radiometric exposure test data

The S190A preflight radiometric exposure test data generated as part of preflight and system test of KM-002 Sequence 29 on flight camera S/N 002 was analyzed. The analysis was to determine camera system transmission using available data which included: (1) films exposed to a calibrated light source subject; (2) filter transmission data; (3) calibrated light source data; (4) density vs. log10 exposure curves for the films; and (5) spectral sensitometric data for the films. The procedure used is outlined, and includes the data and a transmission matrix as a function of field position for nine measured points on each station-film-filter-aperture-shutter speed combination.

Lockwood, H. E.↗