Search NASA⌕ Search

SEARCH · Search NASA

Results for “capillary”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Gravimetric capillary method for kinematic viscosity measurements

A novel version of the capillary method for viscosity measurements of liquids is presented. Viscosity data can be deduced in a straightforward way from mass transfer data obtained by differential weighing during the gravity-induced flow of the liquid between two cylindrical chambers. Tests of this technique with water, carbon tetrachloride, and ethanol suggest that this arrangement provides an accuracy of about +/- 1 percent. The technique facilitates operation under sealed, isothermal conditions and, thus can readily be applied to reactive and/or high vapor pressure liquids.

Rosenberger, Franz↗

Modelling of capillary optics as a focussing hard X-ray concentrator

The development of glass microcapillary arrays by Kumakhov and co-workers in the Soviet Union suggests that it is possible to construct novel devices for concentrating and focussing X-ray beams. Hypothetical focussing concentrators made up of capillary arrays have been configured to operate over a broad range of X-ray energy and its characteristics have been studied with a Monte Carlo ray tracing code. These modeling results indicate that the concentrators would have significant effective area up to 100 keV while their dimensions are similar to conventional grazing incidence telescopes that operate in the soft X-ray band.

Gorenstein, P.↗

Evaluation of capillary electrophoresis for in-flight ionic contaminant monitoring of SSF potable water

Until 1989, ion chromatography (IC) was the baseline technology selected for the Specific Ion Analyzer, an in-flight inorganic water quality monitor being designed for Space Station Freedom. Recent developments in capillary electrophoresis (CE) may offer significant savings of consumables, power consumption, and weight/volume allocation, relative to IC technology. A thorough evaluation of CE's analytical capability, however, is necessary before one of the two techniques is chosen. Unfortunately, analytical methods currently available for inorganic CE are unproven for NASA's target list of anions and cations. Thus, CE electrolyte chemistry and methods to measure the target contaminants must be first identified and optimized. This paper reports the status of a study to evaluate CE's capability with regard to inorganic and carboxylate anions, alkali and alkaline earth cations, and transition metal cations. Preliminary results indicate that CE has an impressive selectivity and trace sensitivity, although considerable methods development remains to be performed.

Mudgett, Paul D.↗

Design and development of a two-phase reservoir for the Capillary Pumped Loop (CAPL) Flight Experiment

The Capillary Pumped Loop (CAPL) Flight Experiment has undergone numerous design modifications to reflect recent changes in the thermal control system baselined for Earth Observation System (EOS) spacecraft. The experiment redesign has also allowed technological advances in two-phase fluid loop components to be incorporated. The experiment's reservoir is one of the components targeted for redesign. The design and development of a new reservoir for the CAPL Flight Experiment is discussed in this paper. A prototype reservoir is described, and a hydrodynamic analysis of its wick structure is included. Testing of the prototype reservoir is also discussed.

Wolf, David A.↗

Role of a microbore capillary column in the development of a portable gas chromatograph-mass spectrometer

An approach to the development of a high-performance, field portable gas chromatograph-mass spectrometer is presented which is based on a combination of a short microbore capillary column and a miniaturized, light-weight focal plane mass spectrograph. Performance results of the short microbore column for the mixture separation of the major pollutants and data on time-resolved mass spectral measurements of overlapped gas chromatograph peaks are reported.

Sinha, Mahadeva P.↗

Experimental and theoretical studies of capillary-pumped loop heat pipes

An experimental investigation of capillary-pumped loop (CPL) head pipes with single and multiple evaporators designed to develop and validate a computer model to predict the performance of CPL heat pipes over a wide range of conditions is discussed. The results of a literature search and review and a numerical study to determine the effects of geometric design parameters on the CPL heat pipe pressure drop and heat transfer characteristics are described. Vapor groove geometry and the use of circular versus rectangular evaporators were studied.

Obot, N. T.↗

Core-centering of compound drops in capillary oscillations: Observations on USML-1 experiments in space

AA Using the existing inviscid theories, an attempt is made to explain the centering of the oscillating liquid shell. Experiments on liquid shells and liquid-core compound drops were conducted using acoustic levitation, in a low-gravity environment during a Space Shuttle flight. It was observed that their inner and outer interfaces became concentric when excited into capillary oscillations. Using the existing inviscid theories, and attempt is made to explain the centering of the oscillating liquid shell. It is concluded that viscosity needs to be considered in order to provide a realistic description of the centering process.

Wang, Taylor G.↗

Capillary surfaces in a wedge: Differing contact angles

The possible zero-gravity equilibrium configurations of capillary surfaces u(x, y) in cylindrical containers whose sections are (wedge) domains with corners are investigated mathematically, for the case in which the contact angles on the two sides of the wedge may differ. In such a situation the behavior can depart in significant qualitative ways from that for which the contact angles on the two sides are the same. Conditions are described under which such qualitative changes must occur. Numerically computed surfaces are depicted to indicate the behavior.

Concus, Paul↗

Time-dependent collisional-radiative model for capillary discharge plasmas

A time-dependent, zero-dimensional collisional-radiative model has been developed to study capillary discharge plasmas in view of possibilities for obtaining population inversion leading to laser action in the extreme ultraviolet and soft x-ray spectral region, by amplifying the Balmer-alpha (H-alpha) line of different hydrogenlike ions with nuclear charges from Z = 3 to Z = 6. The model is described in detail, and results for the case of a carbon plasma are presented. Limitations of the model are discussed and comparison is made between our calculations and recent experimental results.

Pockl, M.↗

COMET service module capillary pumped loop thermal control system test results

The COMmercial Experiment Transporter (COMET) is a satellite that will be launched aboard the Conestoga rocket. The COMET Service Module is designed, integrated and tested by Defense Systems Incorporated for Westinghouse Commercial Space. The Capillary Pumped Loop (CPL) was integrated into the Service Module by OAO Corporation for Defense Systems Incorporated. The Service Module's primary function is to carry payloads to space, providing them with utilities such as tightly controlled thermal environment, electrical power, attitude control, data management, and communications while in orbit. This paper presents the results of functional and performance testings of the CPL Thermal Control System (TCS) for the COMET Service Module.

Yun, James Seokgeun↗

Flight testing of the Capillary Pumped Loop Flight Experiment

The Capillary Pumped Loop Flight Experiment (CAPL) employs a passive two-phase thermal control system that uses the latent heat of vaporization of ammonia to transfer heat over long distances. CAPL was designed as a prototype of the Earth Observing System (EOS) instrument thermal control systems. The purpose of the mission was to provide validation of the system performance in micro-gravity, prior to implementation on EOS. CAPL was flown on STS-60 in February, 1994, with some unexpected results related to gravitational effects on two-phase systems. Flight test results and post flight investigations will be addressed, along with a brief description of the experiment design.

Butler, Dan↗

Steady Capillary Driven Flow

A steady capillary driven flow is developed for a liquid index in a circular tube which is partially coated with a surface modifier to produce a discontinuous wetting condition from one side of the tube to the other. The bulk flow is novel in that it is truly steady, and controlled solely by the physics associated with dynamic wetting. The influence of gravity on the flow is minimized through the use of small diameter tubes approximately O(1 mm) tested horizontally in a laboratory and larger tubes approximately O(10 mm) tested in the low gravity environment of a drop tower. Average steady velocities are predicted and compared against a large experimental data set which includes the effects of tube dimensions and fluid properties. The sensitivity of the velocity to surface cleanliness is dramatic and the advantages of experimentation in a microgravity environment are discussed.

Weislogel, Mark M.↗

Water Surface Currents, Short Gravity-Capillary Waves and Radar Backscatter

Despite their importance for air-sea interaction and microwave remote sensing of the ocean surface, intrinsic properties of short gravity-capillary waves are not well established. This is largely due to water surface currents and their effects on the direct measurements of wave parameters conducted at a fixed point. Frequencies of small scale waves propagating on a surface which itself is in motion, are subject to Doppler shifts. Hence, the high frequency tail of the wave spectra obtained from such temporal observations is smeared. Conversion of this smeared measured-frequency spectra to intrinsic-frequency (or wavenumber) spectra requires corrections for the Doppler shifts. Such attempts in the past have not been very successful in particular when field data were used. This becomes evident if the amplitude modulation of short waves by underlying long waves is considered. Microwave radar studies show that the amplitude of a short wave component attains its maximum value near the crests and its minimum in the troughs of the long waves. Doppler-shifted wave data yield similar results but much larger in modulation magnitude, as expected. In general, Doppler shift corrections reduce the modulation magnitude. Overcorrection may result in a negligible modulation or even in a strong modulation with the maximum amplitude in the wave troughs. The latter situation is clearly contradictory to our visual observations as well as the radar results and imply that the advection by currents is overestimated. In this study, a differential-advection approach is used in which small scale waves are advected by the currents evaluated not at the free surface, but at a depth proportional to their wavelengths. Applicability of this approach is verified by the excellent agreement in phase and magnitude of short-wave modulation between results based on radar and on wave-gauge measurements conducted on a lake.

Atakturk, Serhad S.↗

Salt-Finger Convection in a Stratified Fluid Layer Induced by Thermal and Solutal Capillary Motion

Salt-finger convection in a double-diffusive system is a motion driven by the release of gravitational potential due to different diffusion rates. Normally, when the gravitational field is reduced, salt-finger convection together with other convective motions driven by buoyancy forces will be rapidly suppressed. However, because the destabilizing effect of the concentration gradient is amplified by the Lewis number, with values varying from 10(exp 2) for aqueous salt solutions to 10 (exp 4) for liquid metals, salt-finger convection may be generated at much reduced gravity levels. In the microgravity environment, the surface tension gradient assumes a dominant role in causing fluid motion. In this paper, we report on some experimental results showing the generation of salt-finger convection due to capillary motio on the surface of a stratified fluid layer. A numerical simulation is presented to show the cause of salt-finger convection.

Chen, Chuan F.↗

Influence of Thermocapillary Flow on Capillary Stability: Long Float-Zones in Low Gravity

A model problem is posed to study the influence of flow on the interfacial stability of a nearly cylindrical liquid bridge for lengths near its circumference (the Plateau-Rayleigh limit). The flow is generated by a shear stress imposed on the deformable interface. The symmetry of the imposed shear stress mimics the thermocapillary stress induced on a float-zone by a ring heater (i.e. a full zone). Principal assumptions are (1) zero gravity, (2) creeping flow, and (3) that the imposed coupling at the free surface between flow and temperature fields is the only such coupling. A numerical solution, complemented by a bifurcation analysis, shows that bridges substantially longer than the Plateau-Rayleigh limit are possible. An interaction of the first two capillary instabilities through the stress-induced flow is responsible. Time-periodic standing waves are also predicted in certain parameter ranges. Motivation comes from extra-long float-zones observed in MEPHISTO space lab experiments (June 1994).

Chen, Yi-Ju↗

Capillary Flow in an Interior Corner

The design of fluids management processes in the low-gravity environment of space requires an accurate model and description of capillarity-controlled flow in containers of irregular geometry. Here we consider the capillary rise of a fluid along an interior corner of a container following a rapid reduction in gravity. The analytical portion of the work presents an asymptotic formulation in the limit of a slender fluid column, slight surface curvature along the corner, small inertia, and low gravity. New similarity solutions are found and a list of closed form expressions is provided for flow rate and column length. In particular, it is found that the flow is proportional to t(exp 1/2) for a constant height boundary condition, t(exp 2/5) for a spreading drop, and t(exp 3/5) for constant flow. In the experimental portion of the work, measurements from a 2.2s drop tower are reported. An extensive data set, collected over a previously unexplored range of flow parameters, includes estimates of repeatability and accuracy, the role of inertia and column slenderness, and the effects of corner angle, container geometry, and fluid properties. Comprehensive comparisons are made which illustrate the applicability of the analytic results to low-g fluid systems design.

Weislogel, Mark Milton↗

Stability of Capillary Surfaces in Rectangular Containers: The Right Square Cylinder

The linearized governing equations for an ideal fluid are presented for numerical analysis for the stability of free capillary surfaces in rectangular containers against unfavorable disturbances (accelerations,i.e. Rayleigh-Taylor instability). The equations are solved for the case of the right square cylinder. The results are expressed graphically in term of a critical Bond number as a function of system contact angle. A critical wetting phenomena in the corners is shown to significantly alter the region of stability for such containers in contrast to simpler geometries such as the right circular cylinder or the infinite rectangular slot. Such computational results provide additional constraints for the design of fluids systems for space-based applications.

Weislogel, M. M.↗

An Experimental Study of Pressure Oscillation in a Capillary Pumped Loop with Multiple Evaporators and Condensers

The heat transport capability of a capillary pumped loop (CPL) is limited by the pressure drop that its evaporator wick can sustain. The pressure drop in a CPL is not constant even under seemingly steady operation, but rather exhibits an oscillatory behavior. A hydrodynamic theory based on a mass-spring-dashpot model was previously developed to predict the pressure oscillation in a CPL with a single evaporator and a single condenser. The theory states that the pressure oscillation is a function of physical dimensions of the CPL components and operating conditions. Experimental data agreed very well with theoretical predictions. The hydrodynamic stability theory has recently been extended to predict the pressure oscillations in CPLs with multiple evaporators and multiple condensers. Concurrently, an experimental study was conducted to verify the theory and to investigate the effects of various parameters on the pressure oscillation. Four evaporators with different wick properties were tested using a test loop containing two condenser plates. The test loop allowed the four evaporators to be tested in a single-pump, two-pump or four-pump configuration, and the two condenser plates to be plumbed either in parallel or in series. Test conditions included varying the power input, the reservoir set point temperature, the condenser sink temperature, and the flow resistance between the reservoir and the loop. Experimental results agreed well with theoretical predictions.

Ku, Jen-Tung↗