Radiative properties of an artificial atom coupled to a Josephson-junction array

We study the radiative properties—the Lamb shift, Purcell decay rate, and spontaneous emission dynamics—of an artificial atom coupled to a long, multimode cavity formed by an array of Josephson junctions. Introducing a tunable coupling element between the atom and the array, we demonstrate that such a system can exhibit a crossover from a perturbative to a nonperturbative regime of light-matter interaction as one strengthens the coupling between the atom and the Josephson-junction array. As a consequence, the concept of spontaneous emission as the occupation of the local atomic site being governed by a single complex-valued exponent breaks down. This breakdown, we show, can be interpreted in terms of formation of hybrid atom-resonator modes with radiative losses that are nontrivially related to the effective coupling between individual modes. We develop a singular function expansion approach for the description of the open quantum system dynamics in such a multimode nonperturbative regime. This modal framework generalizes the normal-mode description of quantum fields in a finite volume, incorporating exact radiative losses and incident quantum noise at the delimiting surface. Our results are pertinent to recent experiments with Josephson atoms coupled to high-impedance Josephson-junction arrays.

42 ENGINEERING↗

SRF Cavity Tuners for 3.9 GHz Cryomodules for LCLS-II Project

Fermilab conducted testing of three 3.9 GHz cryomodules for the LCLS-II project that will operate in continuous wave mode. A fast/fine tuning component was added to the LCLS-II 3.9 GHz tuner design due to the cavity bandwidth of 130 Hz which consists of two encapsulated piezos. Several cavities faced problems with fast-tuner operations after cooldown to 2 K and tuning the cavities to 3.9 GHz in cryomodule 2. All the piezo actuators were in working conditions but the slow tuner ranges required to stretch some of the cavities to the operational 3.9 GHz frequency were too small to deliver the required preload on the piezos. This behavior can be attributed to several factors: setting the initial warm cavity frequency during production too high, pressure tests of the warm cryomodule could have changed cavity frequency; and the small bending and twisting of the cavity-tuner system during the cooldown and warmup of the cavities. A decision was made to inelastically retune the warm cavities to decrease the unrestrained frequency by 200-300 kHz, this was done via the slow tuner. The results for this retuning method of three 3.9GHz cryomodules will be discussed.

43 PARTICLE ACCELERATORS↗

Analysis of Niobium Electropolishing Using a Generalized Distribution of Relaxation Times Method

Using electrochemical impedance spectroscopy, we have devised a method of sensing the microscopic surface conditions on the surface of niobium as it is undergoing an electrochemical polishing (EP) treatment. The method uses electrochemical impedance spectroscopy (EIS) to gather information on the surface state of the electrode without disrupting the polishing reaction. The EIS data is analyzed using a so-called distribution of relaxation times (DRT) method. Using DRT, the EIS data can be deconvolved into discrete relaxation time peaks without any a priori knowledge of the electrode dynamics. By analyzing the relaxation time peaks, we are able to distinguish two distinct modes of the EP reaction. As the polishing voltage is increased, the electrode transitions from the low voltage EP mode, characterized by a single relaxation time peaks, to the high voltage EP mode, characterized by two relaxation time peaks. We theorize that this second peak is caused by the formation of an oxide layer on the electrode. We also find that this oxide induced peak transitions from to a negative relaxation time, which is indicative of a blocking electrode process. By analyzing EPed samples, we show that samples polished in the low voltage mode have significantly higher surface roughness due to grain etching and faceting. We find that the surface roughness of the samples only improves when the oxide film peak is present and in the negative relaxation time region. This shows that EIS combined with DRT analysis can be used to predict etching on EPed Nb. This method can also be performed before or during the EP, which could allow for adjustment of polishing parameters to guarantee a smooth cavity surface finish.

43 PARTICLE ACCELERATORS↗

Plasma Processing for In-Situ Field Emission Mitigation of Superconducting Radiofrequency (SRF) Cryomodules

Field emission (FE) is one of the main limiting factors of superconducting radio-frequency (SRF) cavities operating in accelerators and it occurs whenever contaminants, like dust, metal flakes or even absorbates, are present on the surface of the cavity high electric field region. Field emission reduces the maximum achievable accelerating field and generates free electrons that may interact with the beam, damage or activate the beamline. One practical method that can be used to mitigate this problem is in-situ plasma cleaning, or plasma processing. The development of a processing that can be applied in-situ is extremely advantageous, since it enables the recovery of the cryomodule performance without the need of disassembling the whole cryomodule, which is an extremely expensive and time-consuming process. On the other hand, plasma processing only requires the cryomodule warm-up to room-temperature and the subsequent processing of the contaminated cavities. The entire process is reasonably quick and involves a limited number of personnel. For these reasons we would like to advocate for continuing to invest in the R&D of plasma processing to optimize its applicability in cryomodules and for extending the technique to other frequency ranges and cavities geometries.

43 PARTICLE ACCELERATORS↗

Nb₃Sn Coating of a 2.6 GHz SRF Cavity by Sputter Deposition Technique

Nb₃Sn is of interest as a coating for SRF cavities due to its higher transition temperature Tc ~18.3 K and superheating field Hsh ~400 mT, both are twice that of Nb. Nb₃Sn coated cavities can achieve high-quality factors at 4 K and can replace the bulk Nb cavities operated at 2 K. A cylindrical magnetron sputtering system was built, commissioned, and used to deposit Nb₃Sn on the inner surface of a 2.6 GHz single-cell Nb cavity. With two identical cylindrical magnetrons, this system can coat a cavity with high symmetry and uniform thickness. Using Nb-Sn multilayer sequential sputtering followed by annealing at 950°C for 3 hours, polycrystalline Nb₃Sn films were first deposited at the equivalent positions of the cavity’s beam tubes and equator. The film’s composition, crystal structure, and morphology were characterized by energy dispersive spectroscopy, X-ray diffraction, and atomic force microscopy. The Tc of the films was measured by the four-point probe method and was 17.61 to 17.76 K. Based on these studies, ~1.2 micron thick Nb₃Sn was deposited inside a 2.6 GHz Nb cavity. We will discuss first results from samples and cavity coatings, and the status of the coating system.

43 PARTICLE ACCELERATORS↗

NREL Comparison of Absolute Cavity Pyrgeometers, InfraRed Integrating Sphere, and Pyrgeometers Traceable to World Infrared Standard Group: September 25-October 6, 2023

The comparison of the absolute cavity pyrgeometers (ACPs) with the InfraRed Integrating Sphere (IRIS), Eppley Precision Infrared Radiometer (PIR) pyrgeometers, and Kipp & Zonen (KZ) pyrgeometers traceable to the World Infrared Standard Group (WISG) was held during NREL ACP and IRIS Comparisons (NAIC) from September 25 to October 6, 2023. Data from all instruments was collected during nighttime clear sky conditions only. The irradiance measured by the ACPs is collected in 30 seconds intervals during the measurement period of two hours, and 10 seconds intervals during the calibration period of 6 minutes. During the comparison, the average (av) irradiance difference measured by ACPs and IRIS9 varied from -0.75 W/m 2 to 0.76 W/m 2 , standard deviation (sd) from 0.78 W/m 2 to 1.04 W/m 2 , and uncertainty U95 from 1.96 W/m 2 to 2.07 W/m 2 . The average irradiance difference measured by ACP95F3 minus the irradiance measured by all pyrgeometers varied from 1.64 to 3.96 W/m 2 , sd from 1.70 W/m 2 to 1.86 W/m 2 , and uncertainty U 95 from 3.78 W/m 2 to 5.42W/m 2 . Note that from September 25th at 18:31 to September 29 th at 5:30 ACP96F3 irradiance is calculated using Bruce, et al 2023 method.

47 OTHER INSTRUMENTATION↗

Realistic simulations of spin squeezing and cooperative coupling effects in large ensembles of interacting two-level systems

We describe an efficient numerical method for simulating the dynamics of interacting spin ensembles in the presence of dephasing and decay. The method builds on the discrete truncated Wigner approximation for isolated systems, which combines the mean-field dynamics of a spin ensemble with a Monte Carlo sampling of discrete initial spin values to account for quantum correlations. Here we show how this approach can be generalized for dissipative spin systems by replacing the deterministic mean-field evolution by a stochastic process, which describes the decay of coherences and populations while preserving the length of each spin. We demonstrate the application of this technique for simulating nonclassical spin-squeezing effects or the dynamics and steady states of cavity QED models with 10 5 interacting two-level systems. This opens up the possibility to perform accurate real-scale simulations of a diverse range of experiments in quantum optics or with solid-state spin ensembles under realistic laboratory conditions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Beam Tuning Setups for Drift Tube Linacs

Various matching methods for tuning Drift Tube Linacs are overviewed. Special emphasis is on the methods utilizing signature phase scans with single and pairs of Beam Position Monitors (BPM) placed inside or outside of the tuned-up cavity, and that using a combination of phase scans with energy scans.

43 PARTICLE ACCELERATORS↗

Manufacturing control systems and logic for prognosis of defects in composite materials

Presented are manufacturing control systems for composite-material structures, methods for assembling/operating such systems, and transfer molding techniques for predicting and ameliorating void conditions in fiber-reinforced polymer panels. A method for forming a composite-material construction includes receiving a start signal indicating a fiber-based preform is inside a mold cavity, and transmitting a command signal to inject pressurized resin into the mold to induce resin flow within the mold cavity and impregnate the fiber-based preform. An electronic controller receives, from a distributed array of sensors attached to the mold, signals indicative of pressure and/or temperature at discrete locations on an interior face of the mold cavity. The controller determines a measurement deviation between a calibrated baseline value and the pressure and/or temperature values for each of the discrete locations. If any one of the respective measurement deviations exceeds a calibrated threshold, a void signal is generated to flag a detected void condition.

36 MATERIALS SCIENCE↗

Method and apparatus for an insulating glazing unit and compliant seal for an insulating glazing unit

A vacuum insulating glazing unit (VIGU) comprises two or more glass lites (panes) spaced apart from one another and hermetically bonded to an edge seal assembly therebetween. The resulting cavity between the lites is evacuated to create at least one insulating vacuum cavity within which are disposed a plurality of stand-off members to maintain separation between the lites. The edge seal assembly is preferably compliant in the longitudinal (i.e., edgewise) direction to allow longitudinal relative motion between the two lites (e.g., from thermal expansion). The longitudinal compliance may be obtained by imprinting a three-dimensional pattern into the edge seal material. The edge seal assembly is preferably bonded to the lites with a first bond portion that is hermetic and a second bond portion that is load-resistant. Methods for producing VIGUs and/or compliant edge seal assemblies and VIGU and edge seal apparatus are disclosed.

Francis, William H.↗

Optical fields in porous polylactide matrices

Optical fields induced by laser light inside porous polymer matrices (scaffolds) under stimulating effect on cells are investigated. The spectra of light scattering coefficients and anisotropy factors of porous polylactide scaffolds in the visible and near-IR ranges are determined by numerical simulation based on experimental data obtained using a double integrating sphere. Studies are conducted for dry and wet scaffolds fabricated by supercritical fluid foaming and surface-selective laser sintering. The Monte Carlo method is used to calculate the fluence rate distribution under the assumptions of the Henyey – Greenstein phase scattering function and the model phase function of scattering on spherical cavities. It is shown that th e fluence rate distribution mainly depends on the scattering coefficient and the mean cosine of the deflection angle (g-factor). The results obtained are of great practical importance for tissue engineering based on the use of polymeric porous scaffolds with cells to replace tissue defects; they can be used to determine the dose range for laser stimulation of cells. (paper)

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Face seal assembly with thermal management circuit and an associated method thereof

A face seal assembly including a thermal fluid circuit, a turbomachine including the face seal assembly and a method of operating the turbomachine are disclosed. The face seal assembly includes a seal ring including a seal bearing face, at least one internal cavity including a cavity inlet and a cavity outlet. The face seal assembly further including a fluid inlet channel in fluid communication with the cavity inlet of the at least one internal cavity and a pressurized fluid and a fluid outlet port in fluid communication with the cavity outlet of the at least one internal cavity. The at least one internal cavity, the fluid inlet channel and the fluid outlet port define a thermal fluid circuit providing thermal management of the seal ring. In the turbomachine, the face seal assembly is disposed between a stationary component and a rotating component including a rotating component bearing face.

Trivedi, Deepak↗

Development of in situ thickness sensor for vapor diffused Nb3Sn films

Fermilab is one of the leaders in development of vapor diffused Nb3Sn films inside niobium cavities. This material has a higher critical temperature (Tc) than niobium, enabling cavity operation at 4.2 K. This higher operational temperature significantly reduces the infrastructure required for cooling compared to 2 K systems, making superconducting radio-frequency (SRF) technology more accessible. Current deposition methods have relied on iterative testing to determine nominal film thickness, a process that can be time-consuming and imprecise. To address this, we are developing a sensor to measure the thickness of Nb3Sn thin film in situ during vapor diffusion. Our design involves a four-point resistance measurement of a thin film of niobium, inside the coating region. During coating, the change in resistance reflects the conversion of the film from Nb to Nb3Sn, which allows simple integration with the current furnace infrastructure. This sensor would allow real time measurement of the Nb3Sn film thickness, allowing for increased precision in future depositions for cavity applications.

Howard, K. [Chicago U.] (ORCID:0000000325613308)↗

Minimization of thermal deformation in crystal optics for high repetition-rate FEL

Minimizing thermal deformation in X-ray crystal optics is crucial for preserving coherence and wavefront in high-repetition-rate free-electron lasers (FELs). This study presents two approaches to reduce pulse-by-pulse transient thermal deformation in diamond crystals used in cavity-based X-ray FELs (CBXFELs): (1) cryogenic cooling with liquid nitrogen (LN₂), and (2) second-order correction via focusing optics. We revisit the temperature-dependent thermal-mechanical properties of diamond and silicon, implement a finite-element analysis (FEA) method to accelerate convergence to a quasisteady-state regime. Results show that LN₂-cooled diamond crystals meet the stringent deformation requirement of less than 15 pm RMS for the pulse at mJ scale at 1 MHz repetition frequency, and up to 1.5 mJ for 100 kHz. Second-order correction by using focusing elements within the cavity can reduce the impact of thermal deformation for both liquid nitrogen and water cooling.

free electron laser↗

Conceptual design of a high reactive-power ferroelectric fast reactive tuner

We present a novel design of a ferroelectric fast reactive tuner (FE-FRT) capable of modulating mega-VAR reactive power on a submicrosecond timescale. The high reactive power capability of our design extends the range of applications of reactive tuners to numerous applications. We present a detailed analytical model of the performance of a megawatt-class reactive power device and benchmark it against finite-element method eigenmode and frequency domain electromagnetic simulations. We introduce new features, including an annulus design for the ferroelectric capacitors and capacitive window coupling to the cavity. We consider thermal design issues and nonlinear effects in the ferroelectric. The model covers several configurations, allowing control of the frequency of superconducting and normal-conducting cavities in a variety of applications and frequencies. We calculate that the FE-FRT designed should be capable of handling around 0.45 MVAR of reactive power with around 3 kW of resistive losses, providing a frequency tuning range of 8 kHz in an example of 400 MHz cavity geometry. Published by the American Physical Society 2024

43 PARTICLE ACCELERATORS↗

Aerosol-Based Sealant for Air Ducts Technology

Aerosol-based sealant can be used to seal air duct leaks. This is done by pressurizing the ducts and injecting the spray sealant. This technology can be used to seal small (up to ½-inch diameter) and inaccessible duct leaks hidden in wall, ceiling, and floor cavities (Ternes and Hwang2001). The aerosol sealant itself is a nontoxic vinyl polymer (Kallett et al. 2000). The technology is a proprietary duct-sealing method developed jointly by the U.S. government and Aeroseal, the company that holds an exclusive license to use the technology (Ternes and Hwang 2001). Specifically, Lawrence Berkeley National Laboratory developed the aerosol-spray technology with funding from the U.S. Department of Energy (DOE), the U.S. Environmental Protection Agency, and others while Aeroseal developed the current version of the equipment and software to apply the technology in practice (Ternes and Hwang 2001).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

LANL Institutional Computing Close-out Report for Project t22_ocean_time_step

This year, my team made a very productive use of LANL IC time. Four papers were published that used IC resources, and two more are under review. These publications fall into three categories: 1.) Improving tide modeling in the global ocean by adding self attraction and loading (Barton et. al. 2022), ice shelf cavities (Pal et al. 2023), and local time stepping (Lilly et al. 2023). 2.) A new sea ice numerical formulation (Capodaglio 2023). 3.) Performance comparisons, methods, and test cases for ocean model development, This includes a verification suite for ocean models (Bishnu, submitted) and a comparison between Julia and Fortran (Strauss, submitted). A new time-stepping method was introduced in Calandrini et al. (2022). These publications, and the use of LANL IC resources, go hand-in-hand with our mentoring efforts to train young scientists. Two of the lead authors are graduate students who are conducting their PhD research: Kristin Barton at the University of Michigan and Jeremy Lilly at Oregon State. These are both their first publications, and they both have DOE funding and DOE mentors. In addition, Bishnu is a post-doctoral researcher at LANL; Strauss conducted his research as a senior in high school; and Capodaglio, Calandrini and Pal are all early-career scientists who were converted to staff in 2021 or 2022. Here we highlight two publications on improvements in tidal modeling: Barton et al. 2022 and Lilly et al. 2023.

58 GEOSCIENCES↗

Pressure safety approach for PIP-II cryogenic distribution system and cryomodules

The Proton Improvement Plan-II (PIP-II) is a superconducting linear accelerator being built at Fermilab that will provide 800 MeV proton beam for neutrino production. The linac consists of a total of twenty-three (23) cryomodules of five (5) different types. Cooling is required at 2K, 5K and 40K. The Cryogenic Distribution System (CDS) consists of a Distribution Valve Box, ~285 m of cryogenic transfer line, modular Bayonet Cans to interface with cryomodules, and a Turnaround Can. The cryogenic system must provide protection from over-pressure by sizing pressure relief devices for all volumes and process line circuits. The cryomodule cavity circuits have dual pressure ratings, 4.1 bara when cold and 2.05 bara when warm (T>80K). Worst case relieving cases will be identified. The methods for determining heat flux will be presented. For the relieving occurring in the linac tunnel, flow must vent to outside to avoid an oxygen deficiency hazard. Also, we will present vacuum vesse l relief sizing to protect the cryogenic distribution system vacuum shells from over pressure during an internal line rupture. The project is funded by US DOE Offices of Science, High Energy Physics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗