Search NASA⌕ Search

SEARCH · Search NASA

Results for “cell size”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Properties of cirrus generating cells.

Particle size spectra were measured during 20 hr of sampling in cirrus generating cells (uncinus, stratus, spissatus, thunderstorm anvil) and the particle concentration, mean crystal length, ice water content, reflectivity factor, and precipitation rate were calculated from these spectra. Average values of the physical properties in the generating cells were obtained. Growth was found to be downward, reaching a maximum ice water content just below the base of the generating cell. The maximum ice water contents (not including the thunderstorm anvil) were found in cirrus uncinus. Liquid water was not found throughout the cirrus sampling by measurement with the Johnson-Williams hot-wire liquid-water meter; however, it is believed that liquid water is present as a transient phase.

Heymsfield, A. J.↗

Fabrication and testing of sealed silver-zinc cells

A number of Type HS40-7 sealed silver-zinc cells and experimental 40AH sealed silver-zinc cells were fabricated. Cells of each experimental group contained one variation from the standard configuration (HS40-7) cell. Cells from each of five experimental cell groups and cells of the standard configuration were tested to characterize voltage and capacity performance at various discharge rates. The test cells were then subjected to 100 percent DOD Cycle Life Testing at 22 C. Results indicate that material and/or process variations are available which will improve both performance and cycle life of the existing 40 ampere-hour sealed silver-zinc cell configurations. The average cycle life to 50 percent loss of nominal capacity in cells from two (2) of the experimental groups was 150 - 165 cycles. A series of 12 ampere-hour cells was fabricated and tested as part of a program to incorporate the 40AH sealed silver-zinc cell fabrication technology into a cell of smaller size. Base-line configuration cells and experimental variations were produced using the HS40-7 cell fabrication and processing methods adapted to the smaller cell size.

Donnel, C. P., III↗

Effects of anisosmotic stress on cardiac muscle cell length, diameter, area, and sarcomere length

The purpose of this study was to examine the effects of anisosmotic stress on adult mammalian cardiac muscle cell (cardiocyte) size. Cardiocyte size and sarcomere length were measured in cardiocytes isolated from 10 normal rats and 10 normal cats. Superfusate osmolarity was decreased from 300 +/- 6 to 130 +/- 5 mosM and increased to 630 +/- 8 mosM. Cardiocyte size and sarcomere length increased progressively when osmolarity was decreased, and there were no significant differences between cat and rat cardiocytes with respect to percent change in cardiocyte area or diameter; however, there were significant differences in cardiocyte length (2.8 +/- 0.3% in cat vs. 6.1 +/- 0.3% in rat, P < 0.05) and sarcomere length (3.3 +/- 0.3% in cat vs. 6.1 +/- 0.3% in rat, P < 0.05). To determine whether these species-dependent differences in length were related to diastolic interaction of the contractile elements or differences in relative passive stiffness, cardiocytes were subjected to the osmolarity gradient 1) during treatment with 7 mM 2,3-butanedione monoxime (BDM), which inhibits cross-bridge interaction, or 2) after pretreatment with 1 mM ethylene glycol-bis(beta-aminoethyl ether)-N, N,N',N'-tetraacetic acid (EGTA), a bivalent Ca2+ chelator. Treatment with EGTA or BDM abolished the differences between cat and rat cardiocytes. Species-dependent differences therefore appeared to be related to the degree of diastolic cross-bridge association and not differences in relative passive stiffness. In conclusion, the osmolarity vs. cell size relation is useful in assessing the cardiocyte response to anisosmotic stress and may in future studies be useful in assessing changes in relative passive cardiocyte stiffness produced by pathological processes.

Non-NASA Center↗

Integrins, tensegrity, and mechanotransduction

Physical forces, such as those due to gravity, play an important role in tissue development and remodeling. Yet, little is known about how individual cells sense mechanical signals or how they transduce them into a chemical response. Rather than listing the numerous signal pathways that have been found to be sensitive to mechanical stimulation, we need to place potential molecular signaling mechanisms within the context of the entire cell. The model presented is based on the concept that cells use tensegrity architecture to organize their cytoskeleton and stabilize their form. Studies with stick and string tensegrity cell models predict that living cells are hard-wired to respond immediately to external mechanical stresses. This hard-wiring exists in the form of discrete cytoskeletal filament networks that mechanically couple specific cell surface receptors, such as integrins, to nuclear matrix scaffolds and to potential transducing molecules that physically associate with the cytoskeleton. If these signaling molecules do function in a "solid-state", then mechanical stresses may be transduced into biochemical responses through force-dependent changes in cytoskeletal geometry or through local alterations in thermodynamic or kinetic parameters. Changes in cytoskeletal tension (prestress) also may play a role in signal amplification and adaptation. Recent experimental results are described which provide direct support for the tensegrity theory.

Review↗

Antisense oligodeoxynucleotide inhibition of a swelling-activated cation channel in osteoblast-like osteosarcoma cells

By patch-clamp analysis, we have shown that chronic, intermittent mechanical strain (CMS) increases the activity of stretch-activated cation channels of osteoblast-like UMR-106.01 cells. CMS also produces a swelling-activated whole-cell conductance (Gm) regulated by varying strain levels. We questioned whether the swelling-activated conductance was produced by stretch-activated cation channel activity. We have identified a gene involved in the increase in conductance by using antisense oligodeoxynucleotides (ODN) derived from the alpha 1-subunit genes of calcium channels found in UMR-106.01 cells (alpha1S, alpha1C, and alpha1D). We demonstrate that alpha 1C antisense ODNs abolish the increase in Gm in response to hypotonic swelling following CMS. Antisense ODNs to alpha1S and alpha1D, sense ODNs to alpha1C, and sham permeabilization had no effect on the conductance increase. In addition, during cell-attached patch-clamp studies, antisense ODNs to alpha1c completely blocked the swelling-activated and stretch-activated nonselective cation channel response to strain. Antisense ODNs to alpha1S treatment produced no effect on either swelling-activated or stretch-activated cation channel activity. There were differences in the stretch-activated and swelling-activated cation channel activity, but whether they represent different channels could not be determined from our data. Our data indicate that the alpha1C gene product is involved in the Gm and the activation of the swelling-activated cation channels induced by CMS. The possibility that swelling-activated cation channel genes are members of the calcium channel superfamily exists, but if alpha1c is not the swelling-activated cation channel itself, then its expression is required for induction of swelling-activated cation channel activity by CMS.

NASA Discipline Musculoskeletal↗

Flight qualification test results for violet cells

The violet solar cell has been submitted to a flight qualification program. The tasks included in this program were: to define the violet cell's electrical output from -100 C to +100 C; to determine the violet cell's degradation under 2 MeV, 1 MeV and .3 MeV proton irradiation, under a high humidity environment and under ultraviolet light; to thermal cycle two similar modules of violet cells; to flight qualify a full size violet cell panel for the IMP-J flight; and to obtain a primary balloon-flown standard of the violet cell type. The results of these tests demonstrate that the violet cell is fully qualified for space flight use with no further development work. The tests show that the violet cell offers a power increase of at least twenty-one per cent over presently available commercial cells.

Gaddy, E. M.↗

Automated assembly of Gallium Arsenide and 50-micron thick silicon solar cell modules

The TRW automated solar array assembly equipment was used for the module assembly of 300 GaAs solar cells and 300 50 micron thick silicon solar cells (2 x 4 cm in size). These cells were interconnected with silver plated Invar tabs by means of welding. The GaAs cells were bonded to Kapton graphite aluminum honeycomb graphite substrates and the thin silicon cells were bonded to 0.002 inch thick single layer Kapton substrates. The GaAs solar cell module assembly resulted in a yield of 86% and the thin cell assembly produced a yield of 46% due to intermittent sticking of weld electrodes during the front cell contact welding operation. (Previously assembled thin cell solar modules produced an overall assembly yield of greater than 80%).

Mesch, H. G.↗

Nuclear size as a cell-kinetic marker for osteoblast differentiation

A nuclear morphometric assay for preosteoblasts is introduced as a cell-kinetic technique, applicable to routine histological preparations of mineralized tissue. Because this method is a morphological marker for osteoblast precursor cell differentiation, it provides a new dimension for determining the mechanism of osteoblast histogenesis. Osteoblast precursors of the periodontal ligament are a mixed population of progenitors, kinetically separable into two distinct groups according to nuclear size. Preosteoblasts, the immediate proliferating precursors of osteoblasts, have large nuclei (greater than 170 micrometers3) and are derived from relatively undifferentiated fibroblastlike cells, which have smaller nuclei (less than 80 micrometers3). Increase in nuclear volume, during G1 phase of the cell cycle, is apparently a morphological manifestation of change in genomic expression. This key event in preosteoblast differentiation is related to mechanical stress/strain and may be an important rate-limiting step in osteoblast histogenesis.

Non-NASA Center↗

Pore size engineering applied to the design of separators for nickel-hydrogen cells and batteries

Pore size engineering in starved alkaline multiplate cells involves adopting techniques to widen the volume tolerance of individual cells. Separators with appropriate pore size distributions and wettability characteristics (capillary pressure considerations) to have wider volume tolerances and an ability to resist dimensional changes in the electrodes were designed. The separators studied for potential use in nickel-hydrogen cells consist of polymeric membranes as well as inorganic microporous mats. In addition to standard measurements, the resistance and distribution of electrolyte as a function of total cell electrolyte content were determined. New composite separators consisting of fibers, particles and/or binders deposited on Zircar cloth were developed in order to engineer the proper capillary pressure characteristics in the separator. These asymmetric separators were prepared from a variety of fibers, particles and binders.

Abbey, K. M.↗

Pore size engineering applied to the design of separators for nickel-hydrogen cells and batteries

Pore size engineering in starved alkaline multiplate cells involves adopting techniques to widen the volume tolerance of individual cells. Separators with appropriate pore size distributions and wettability characteristics (capillary pressure considerations) to have wider volume tolerances and an ability to resist dimensional changes in the electrodes were designed. The separators studied for potential use in nickel-hydrogen cells consist of polymeric membranes as well as inorganic microporous mats. In addition to standard measurements, the resistance and distribution of electrolyte as a function of total cell electrolyte content were determined. New composite separators consisting of fibers, particles and/or binders deposited on Zircar cloth were developed in order to engineer the proper capillary pressure characteristics in the separator. These asymmetric separators were prepared from a variety of fibers, particles and binders. Previously announced in STAR as N83-24571

Abbey, K. M.↗

Differential changes in size distribution of xyloglucan in the cell walls of gravitropically responding Pisum sativum epicotyls

Growth-related change in the size distribution of hemicellulosic wall polymers during the gravitropic curvature response of intact pea (Pisum sativum L. cv Alaska) epicotyls was examined by gel-filtration chromatography. The gravitropic response was characterized by the appearance of curvature 20 to 30 min after horizontal placement, with 35 degrees of curvature attained by 80 min. Correlated with the onset of curvature, on the upper side of the epicotyl, there was a conspicuous transient increase in the abundance of relatively large hemicellulosic xyloglucan polymers, similar to increases previously found under conditions where diminished wall extensibility was expected. On the lower side there was a moderate, slower, and longer-term increase in abundance of small xyloglucan, similar to changes previously found in connection with auxin-stimulated growth responses. Both shifts occurred primarily in the epidermis. They appear to represent two coordinated physiological mechanisms contributing to differential growth.

Non-NASA Center↗

Grain size dependence of silicon solar cell parameters

Measurements of the non-uniform diffusion length of the minority carriers near grain boundaries in polycrystalline silicon have been used to develop an analytical model for the calculation of solar cell output as a function of grain size. Experimental results are presented which verify the theoretical analysis. Variation of open circuit voltage and fill factor with grain size is discussed.

Koliwad, K. M.↗

Impedance measurements on a spiral-wound nickel/metal hydride cell cycled in a simulated Leo orbit

A spiral-wound size C cell was cycled at 25 C in a low earth orbit (LEO) regime at 50 percent depth of discharge (DOD) with approximately five percent over-charge. The nominal capacity was 3.5 AH. The cell was cycled for 2000 cycles. Capacity checks and impedance measurements over the complete range of state of charge were made upon receipt and after 500, 1000, and 2000 cycles. The capacity of the cell was essentially unchanged until after the impedance measurements at 2000 cycles. Only small changes in the impedance parameters were observed, but there was somewhat more scatter in the data after 2000 cycles. When the cell was returned to LEO cycling after 2000 cycles, only 38 percent of the capacity could be obtained. It is believed that the cell failed because of an equipment failure at the end of the final impedance measurements which allowed an over-discharge.

Reid, Margaret A.↗

Fabrication and testing of large size nickel-zinc cells

The design and construction of nickel zinc cells, containing sintered nickel electrodes and asbestos coated inorganic separator materials, were outlined. Negative electrodes were prepared by a dry pressing process while various inter-separators were utilized on the positive electrodes, consisting of non-woven nylon, non-woven polypropylene, and asbestos.

Klein, M.↗

Influence of stress, weightlessness, and simulated weightlessness on differentiation of preosteoblasts

The effects of 18.5 days of weightlessness aboard a satellite, stress of restricted feeding, stress of noise and vibration to simulate space flight and 21 days of head down suspension via the Morey-Holton model for simulated weightlessness was studied. Nuclear size of fibroblastlike cells in PDL on the anterior surface of maxillary first molars was classified as: (1) A-cells, self perpetuating precursors with a nuclear volume 80 micron B-cells, nonosteogenic fibroblasts with a nuclear volume of 80-119 micron 3, C-cells, preosteoblasts that are in G1 stage of the cell cycle with a nuclear size of 120-170 micro, and D-cells, preosteoblasts that are in G2 stage of the cell cycle with a nuclear size 170 micro.

Roberts, W. E.↗