Search NASA⌕ Search

SEARCH · Search NASA

Results for “charge yield”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Series-Connected Buck Boost Regulators

A series-connected buck boost regulator (SCBBR) is an electronic circuit that bucks a power-supply voltage to a lower regulated value or boosts it to a higher regulated value. The concept of the SCBBR is a generalization of the concept of the SCBR, which was reported in "Series-Connected Boost Regulators" (LEW-15918), NASA Tech Briefs, Vol. 23, No. 7 (July 1997), page 42. Relative to prior DC-voltage-regulator concepts, the SCBBR concept can yield significant reductions in weight and increases in power-conversion efficiency in many applications in which input/output voltage ratios are relatively small and isolation is not required, as solar-array regulation or battery charging with DC-bus regulation. Usually, a DC voltage regulator is designed to include a DC-to-DC converter to reduce its power loss, size, and weight. Advances in components, increases in operating frequencies, and improved circuit topologies have led to continual increases in efficiency and/or decreases in the sizes and weights of DC voltage regulators. The primary source of inefficiency in the DC-to-DC converter portion of a voltage regulator is the conduction loss and, especially at high frequencies, the switching loss. Although improved components and topology can reduce the switching loss, the reduction is limited by the fact that the converter generally switches all the power being regulated. Like the SCBR concept, the SCBBR concept involves a circuit configuration in which only a fraction of the power is switched, so that the switching loss is reduced by an amount that is largely independent of the specific components and circuit topology used. In an SCBBR, the amount of power switched by the DC-to-DC converter is only the amount needed to make up the difference between the input and output bus voltage. The remaining majority of the power passes through the converter without being switched. The weight and power loss of a DC-to-DC converter are determined primarily by the amount of power processed. In the SCBBR, the unswitched majority of the power is passed through with very little power loss, and little if any increase in the sizes of the converter components is needed to enable the components to handle the unswitched power. As a result, the power-conversion efficiency of the regulator can be very high, as shown in the example of Figure 1. A basic SCBBR includes a DC-to-DC converter (see Figure 2). The switches and primary winding of a transformer in the converter is connected across the input bus, while the secondary winding and switches are connected in series with the output bus, so that the output voltage is the sum of the input voltage and the secondary voltage of the converter. In the breadboard SCBBR, the input voltage applied to the primary winding is switched by use of metal oxide/semiconductor field-effect transistors (MOSFETs) in a full bridge circuit; the secondary winding is center-tapped, with two MOSFET switches and diode rectifiers connected in opposed series in each leg. The sets of opposed switches and rectifiers are what enable operation in either a boost or a buck mode. In the boost mode, input voltage and current, and the output voltage and current are all positive; that is, the secondary voltage is added to the input voltage and the net output voltage can be regulated at a value equal or greater than the input voltage. In the buck mode, input voltage is still positive and the current still flows in the same direction in the secondary, but the switches are controlled such that some power flows from the secondary to the primary. The voltage across the secondary and the current into the primary are reversed. The result is that the output voltage is lower than the input voltage, and some power is recirculated from the converter secondary back to the input. Quantitatively, the advantage of an SCBBR is a direct function of the regulation range required. If, for example, a regulation range of 20 percent is required for a 500-W supply, th it suffices to design the DC-to-DC converter in the SCBBR for a power rating of only 100 W. The switching loss and size are much smaller than those of a conventional regulator that must be rated for switching of all 500 W. The reduction in size and the increase in efficiency are not directly proportional to switched-power ratio of 5:1 because the additional switches contribute some conduction loss and the input and output filters must be larger than those typically required for a 100-W converter. Nevertheless, the power loss and the size can be much smaller than those of a 500-W converter.

Birchenough, Arthur G.↗

Gaseous NH4Cl revisited - A computational investigation of the potential surface and properties

An investigation of the potential surface and properties of the ground state of gaseous NH4Cl is presented. The calculations, which utilize a good basis set and include investigation of the valence correlation effects, result in a description of gaseous NH4Cl as a weakly bound complex with NH3 and HCl structures essentially equivalent to those of the isolated fragments. The charge distributions within the fragments are modifed in the complex, however, and there is a small amount of charge transfer. The results are in reasonable agreement with estimate of D sub 0, super 0 from high temperature mass spectroscopic investigations and vibrational frequencies from matrix experiments. The equilibrium constant for the reversible reaction NH4Cl yields NH3 + HCl indicates that the homogeneous formation of NH4Cl does not represent a significant chemical sink for HCl in the upper atmosphere

Raffenetti, R. C.↗

A silicon surface barrier telescope for solar particles identification

From the results three conclusions can be made: (1) the detector system described and tested is capable of good charge resolution from He to Al although beyond Ne the statistic is very poor; (2) in the high gain mode, isotopic resolution has been achieved for Li-6/Li-7 Be-7/Be-9; (3) the much higher yield of He over He and of Be-9 over Be-10 in these types of nuclear reactions prevents obtaining experimental evidence of those isotopes, although it is believed that, at least He-3/He-4 can be resolved under other more favorable conditions (i.e., solar He-3-rich events).

Sequeiros, J.↗

Designing Delta-DOR acquisition strategies to determine highly elliptical earth orbits

Delta-DOR acquisition strategies are designed for use in determining highly elliptical earth orbits. The requirements for a possible flight demonstration are evaluated for the Charged Composition Explorer spacecraft of the Active Magnetospheric Particle Tracer Explorers. The best-performing strategy uses data spanning the view periods of two orthogonal baselines near the same orbit periapse. The rapidly changing viewing geometry yields both angular position and velocity information, but each observation may require a different reference quasar. The Delta-DOR data noise is highly dependent on acquisition geometry, varying several orders of magnitude across the baseline view periods. Strategies are selected to minimize the measurement noise predicted by a theoretical model. Although the CCE transponder is limited by S-band and a small bandwidth, the addition of Delta-DOR to coherent Doppler and range improves the one-sigma apogee position accuracy by more than an order of magnitude. Additional Delta-DOR accuracy improvements possible using dual-frequency (S/X) calibration, increased spanned bandwidth, and water-vapor radiometry are presented for comparison. With these benefits, the residual Delta-DOR data noise is primarily due to quasar position uncertainties.

Frauenholz, R. B.↗

Pressure versus drag effects on crater size

The topic of atmospheric effects on crater formation is very complex because it includes not only pressure effects on excavation, but also drag effects on ejecta placement. Experiments have to be designed very carefully to allow isolation of the two phenomena. Historically, numerous investigators have shown an influence of atmospheric pressure. However, none have identified the scaling that correctly isolates pressure from drag effects. On-going work in explosive cratering has produced scaling paradigms for deeply buried explosive charges where drag effects are negligible. Here it was found that increased pressure caused significant induced strength effects that impeded crater excavation. The effect is more pronounced with increasing burial depth and less pronounced with increased yield.

Schmidt, R. M.↗

Variability in Mt. Sharp Group Bedrock as Seen By ChemCam Passive and Active Spectra

The Curiosity rover landed in Gale crater in August 2012 and has since been travelling up the central sedimentary mound known as Mt. Sharp. The ChemCam instrument on Curiosity was designed primarily for the use of Laser Induced Breakdown Spectroscopy (LIBS), where a laser ablates a small amount of material from the target and the spectrum of the resulting plasma yields elemental abundance data. ChemCam’s three spectrometers range from 240-905 nm and can also take passive spectra (without the use of the laser). The spectral range ChemCam passive spectra observe is sensitive to charge-transfer and crystal field absorptions related to iron-bearing minerals. In the first 2934 sols of Curiosity’s mission, 9,400 passive spectra were taken of bedrock targets in Mt. Sharp’s Murray and Carolyn Shoemaker formations. We examine these spectra using spectral slope/ratio and band depth calculations as well as Principal Component Analysis (PCA). For the first time, paired passive spectra and LIBS elemental abundances are compared on a large scale. Finally, CheMin data are compared to ChemCam passive observations to understand sources of spectral variability.

H T Manelski↗

Cosmic ray mass and momentum spectra at mountain altitude

A cosmic ray mass spectrometer using a superconducting magnet, digitized wire spark chambers, and a scintillation counter time of flight system, has been operated at an altitude of 2750 meters. The apparatus is most sensitive to charged particles with momentum to mass ratios between 0.2 and 2.0. Results for the momentum spectra of protons and deuterons are presented, as well as upper limits for H-3 and He-3. The reaction nucleon + nucleon yields deuteron + pion accounts for part of the observed deuteron spectrum in the 0.9 to 3 GeV/c region.-

Barber, H. B.↗

Electrochemical behavior of niobium triselenide cathode in lithium secondary cells

Niobium triselenide cathodes in Li ambient-temperature rechargeable batteries for space applications undergo a topotactic reaction, with three equivalents of Li at high positive potential furnishing high energy density. It also yields good electronic conductivity, a long life cycle, and high diffusivity for Li. An attempt is presently made to characterize the intercalation mechanism between Li and NbSe3 by means of an ac impedance study conducted at various charge stages in the process of SbSe3 reduction. An effort is also made to predict the charge state of NbSe3 nondestructively, on the basis of the impedance parameters.

Ratnakumar, B. V.↗

The Energy Spectra of Heavy Nuclei Measured by the ATIC Experiment

ATIC (Advanced Thin Ionization Calorimeter) is a balloon-borne experiment to measure the spectra and composition of primary cosmic rays in the region of total energy from 100 GeV to near 100 TeV for Z from 1 to 26. ATIC consists of a pixelated silicon matrix detector to measure charge plus a fully active BGO calorimeter, to measure energy, located below a carbon target interleaved with three layers of scintillator hodoscope. The ATIC instrument had a second (scientific) flight from McMurdo, Antarctica from 12/29/02 to 1/18/03, yielding 20 days of good data. The GEANT 3.21 Monte Carlo code with the QGSM event generator and the FLUKA code with the DPMJET-II event generator were used to convert energy deposition measurements to primary energy. We present the preliminary energy spectra for the abundant elements C, O, Ne, Mg, Si and Fe and compare them with the results of the first (test) flight of ATIC in 2000-01 and with results from the HEAO-3 and CRN experiments.

Panov, A. D.↗

Oxygen and hydrogen ion densities above Millstone Hill.

Measurements of the vertical flux of oxygen ions, when combined with simultaneous measurements of electron density and of electron and ion temperatures, present a unique opportunity to examine conditions in the topside ionosphere. The measured fluxes and densities may be used directly to evaluate terms in the O+ continuity equation without requiring any assumptions to be made about neutral winds, electric fields, or the ambipolar diffusion coefficient. From observations at Millstone Hill we have, in this way, derived the rate of loss of O+ in the charge-exchange reaction with hydrogen, the rate of photoionization of atomic oxygen, and the rate of loss of O+ in reactions with N2 and O2. In combination with laboratory and theoretical results, these rates can be interpreted to yield number densities of the corresponding neutral species. When the measured fluxes are examined for consistency with measured density gradients and temperature profiles, we find clear evidence of wind-induced or electrodynamic vertical drifts larger than 60 m/sec.

Schunk, R. W.↗

Atlas of reflectance spectra of terrestrial, lunar and meteoritic powders and frosts from 92 to 1800 nm

The reflectance spectra of powdered samples of selected minerals, meteorites, lunar materials and frosts are presented as an aid in the interpretation of present and future remote sensing data of solar system objects. Spectra obtained in separate wavelength regions have been combined and normalized, yielding coverage from 92 to 1800 nm. Spectral features include reflectance maxima in the far UV region produced by valence-conduction interband transitions, and reflectance minima in the near UV, visible and near IR regions, produced by charge transfer and crystal field transitions. Specific maxima and minima are diagnostic of mineral type and composition; additionally, the minerals present in mixtures such as meteorites and lunar samples can be determined.

Wagner, Jeffrey↗

The propagation speed of a positive lightning return stroke

The first direct determination of the propagation speed of a lightning return stroke lowering positive charge to ground has been made. This stroke was the third of eight otherwise negative strokes in a triggered lightning flash initiated at the Kennedy Space Center, FL. Two independent optical systems, one photographic and the other photoelectric, yielded common recordings for the third and fourth strokes; the respective two-dimensional return stroke propagation speeds were 1.0 vs 0.93 x 10 to the 8th m/s for the positive (third) stroke and 1.0 vs 1.0 x 10 to the 8th m/s for the fourth stroke. Using fast electric-field data, the positive stroke peak current was estimated to be 21 kA. Photoelectric data only yielded propagation speeds of 1.4, 1.6, 1.2, 1.3, 1.0 and 0.90 x 10 to the 8th m/s for the first, second and fifth through eighth return strokes, respectively.

Idone, Vincent P.↗

Lifetimes of bacteriochlorophyll fluorescence in Rhodopseudomonas viridis and Heliobacterium chlorum at low temperatures

Fluorescence lifetimes of isolated membranes of Rhodopseudomonas viridis were measured in the temperature range of 77 K to 25 K. At room temperature, the main component of the fluorescence decay of bacteriochlorophyll (BChl) b had a time constant of 50 ps. In contrast to other purple bacteria, the emission at low temperature was spectrally homogeneous and showed essentially single lifetimes of 140 ps at 77 K and 180 ps at 25 K, with the primary electron donor in the oxidized state. Taking into account the relative fluorescence yields with open and closed reaction centers, we arrive at numbers of 125 ps and 215 ps, respectively, for open reaction centers. These numbers are significantly smaller than expected on the basis of measurements of the efficiency of charge separation, perhaps suggesting that the excitation decay in the absence of reaction centers is considerably faster at low temperature than at room temperature. At least four different spectral components with different lifetimes were observed at 25 K in the emission of Heliobacterium chlorum, a short-wavelength component of about 30 ps and three longer-wavelength components of about 100 ps, 300 ps, and 900 ps. This indicates a strong heterogeneity in the emitting pigment, BChl g-808. The component with the shortest lifetime does not appear to be affected by the redox state of the reaction center and might reflect energy transfer to BChl g species which are connected to the reaction center.

NASA Discipline Number 52-30↗

Charge abundance of cosmic rays at their source

The relative charge abundance of galactic cosmic-ray nuclei is measured between 600 and 1000 MeV per nucleon over a range of Z from 2 to 28. The abundances observed at earth are extrapolated to the cosmic-ray source, yielding accurate source abundances for 15 elements. These abundances, together with recently measured isotopic abundance ratios, are compared with the average abundances observed in another sample of accelerated material - solar cosmic rays. Appreciable differences are found in the composition for the elements He, C, N, and Ne. The galactic and solar cosmic-ray abundances are also compared with a variety of compilations of unaccelerated matter.

Webber, W. R.↗

Radiation exposure of LDEF: Initial results

Initial results from LDEF include radiation detector measurements from four experiments, P0006, P0004, M0004, and A0015. The detectors were located on both the leading and trailing edges of the orbiter and also on the Earthside end. This allowed the directional dependence of the incoming radiation to be measured. Total absorbed doses from thermoluminescent detectors (TLDs) verified the predicted spatial east-west dose ratio dependence of a factor approx. 2.5, due to trapped proton anisotropy in the South Atlantic Anomaly. On the trailing edge of the orbiter a range of doses from 6.64 to 2.91 Gy were measured under Al equivalent shielding of 0.42 to 1.11 g/sq cm. A second set of detectors near this location yielded doses of 6.48 to 2.66 Gy under Al equivalent shielding of 0.48 to 15.4 g/sq cm. On the leading edge, doses of 2.58 to 2.10 Gy were found under Al equivalent shielding of 1.37 to 2.90 g/sq cm. Initial charged particle LET (linear energy transfer) spectra, fluxes, doses and dose equivalents, for LET in H2O greater than or = 8 keV/micron, were measured with plastic nuclear track detectors (PNTDs) located in two experiments. Also preliminary data on low energy neutrons were obtained from detectors containing (6)LiF foils.

Benton, E. V.↗

Microencapsulation and Electrostatic Processing Device

A microencapsulation and electrostatic processing (MEP) device is provided for forming microcapsules. In one embodiment, the device comprises a chamber having a filter which separates a first region in the chamber from a second region in the chamber. An aqueous solution is introduced into the first region through an inlet port, and a hydrocarbon/ polymer solution is introduced into the second region through another inlet port. The filter acts to stabilize the interface and suppress mixing between the two immiscible solutions as they are being introduced into their respective regions. After the solutions have been introduced and have become quiescent, the interface is gently separated from the filter. At this point, spontaneous formation of microcapsules at the interface may begin to occur, or some fluid motion may be provided to induce microcapsule formation. In any case, the fluid shear force at the interface is limited to less than 100 dynes/sq cm. This low-shear approach to microcapsule formation yields microcapsules with good sphericity and desirable size distribution. The MEP device is also capable of downstream processing of microcapsules, including rinsing, re-suspension in tertiary fluids, electrostatic deposition of ancillary coatings, and free-fluid electrophoretic separation of charged microcapsules.

Morrison, Dennis R.↗

Photoemission Experiments for Charge Characteristics of Individual Dust Grains

Photoemission experiments with UV radiation have been performed to investigate the microphysics and charge characteristics of individual isolated dust grains of various compositions and sizes by using the electrodynamic balance facility at NASA Marshall Space Flight Center. Dust particles of 1 - 100 micrometer diameter are levitated in a vacuum chamber at pressures approx. 10(exp -5) torr and exposed to a collimated beam of UV radiation in the 120-300 nanometers spectral range from a deuterium lamp source with a MgF2 window. A monochromator is used to select the UV radiation wavelength with a spectral resolution of 8 nanometers. The electrodynamic facility permits measurements of the charge and diameters of particles of known composition, and monitoring of photoemission rates with the incident UV radiation. Experiments have been conducted on Al2O3 and silicate particles, and in particular on JSC-1 Mars regolith simulants, to determine the photoelectron yields and surface equilibrium potentials of dust particles when exposed to UV radiation in the 120-250 micrometers spectral range. A brief discussion of the experimental procedure, the results of photoemission experiments, and comparisons with theoretical models will be presented.

Abbas, M. M.↗

Alternative approaches to space-based power generation

Satellite Power Stations (SPS) would generate electrical power in space for terrestrial use. Their geosynchronous orbit location permits continuous microwave power transmission to ground receiving antenna farms. Eight approaches to the generation of the electrical power to be transmitted were investigated. Configurations implementing these approaches were developed through an optimization process intended to yield the lowest cost for each. A complete program was baselined for each approach, identifying required production rates, quantities of launches, required facilities, etc. Each program was costed, including the associated launches, orbital assembly, and maintenance operations. The required electric power charges to amortize these costs were calculated. They range from 26 to 82 mills/kWh (ground busbar).

Gregory, D. L.↗