Search NASA⌕ Search

SEARCH · Search NASA

Results for “cloud calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Impact of cirrus on the surface radiative environment at the FIRE ETLA Palisades, NY site

FIRE Extended Time Limited Area (ETLA) observations provide year round information critical to gaining a better understanding of cloud/climate interactions. The Lamont/Rutgers team has participated in the ETLS program through the collection and analysis of shortwave and longwave downwelling irradiances at Palisades, NY. These data are providing useful information on surface radiative fluxes with respect to sky condition, solar zenith angle and season. Their utility extends to the calibration and validation of cloud/radiative models and satellite cloud and radiative retrievals. The impact cirrus clouds have on the surface radiative environment is examined using Palisades ETLA information on atmospheric transmissivities and downwelling longwave fluxes for winter and summer cirrus and clear sky episodes in 1987.

Robinson, David A.↗

Automatic analysis of stereoscopic GOES/GOES and GOES/NOAA image pairs for measurement of hurricane cloud top height and structure

Results are presented from a baseline study using an synthetic stereo image pair to test the Automatic Stereo Analysis (ASA) technique for reproducing cloud top structure. The ASA analysis, display, and calibration procedures are described. A GEO/LEO (GOES/NOAA AVHRR) image pair from Hurrican Allen in 1980 is used to illustrate the results that can be obtained using the ASA technique. Also, results are presented from applying the ASA technique to a GEO/GEO (GOES/GOES) image pair of Hurricane Gilbert in 1988.

Hasler, A. F.↗

Effect of gas mass flux on cryogenic liquid jet breakup

A scattered-light scanning instrument developed at NASA Lewis Research Center was used to measure the characteristic drop size of clouds of liquid nitrogen droplets. The instrument was calibrated with suspensions of monosized polystyrene spheres. In this investigation of the mechanism of liquid nitrogen jet disintegration in a high-velocity gas flow, the Sauter mean diameter, D32, was found to vary inversely with the nitrogen gas mass flux raised to the power 1.33. Values of D32 varied from 5 to 25 microns and the mass flux exponent of 1.33 agrees well with theory for liquid jet breakup in high-velocity gas flows. The loss of very small droplets due to the high vaporization rate of liquid nitrogen was avoided by sampling the spray very close to the atomizer, i.e., 1.3 cm downstream of the nozzle orifice. The presence of high velocity and thermal gradients in the gas phase also made sampling of the particles difficult. As a result, it was necessary to correct the measurements for background noise produced by both highly turbulent gas flows and thermally induced density gradients in the gas phase.

Ingebo, R. D.↗

Retrieval of Ozone Profile from Ground-Base Zenith Sky Measurements

In this talk I will discuss recent results from examining the information content in zenith sky UV (ZUV) measurements from ground for the retrieval of vertical ozone profile. Our results indicate that ZUV can provide high quality ozone profile from ground to 50 km at roughly 10 krn vertical resolution that can be used for the calibration of satellite instruments. However, to take advantage of this the instruments must be better calibrated and it is also necessary that the ground-based Brewer instruments are operated in a mode that is different from the routine operational mode. This will allow one to correct for instrument calibration drifts and to remove noise due to clouds and aerosols. A key technical issue is if the instrument can be reprogrammed to do so.

Bhartia, P. K.↗

Overview and Scientific Agenda of Global Precipitation Mission

This paper addresses the status of the Global Precipitation Mission (GPM) currently planned for launch in the 2007-2008 time frame. The GPM notional design involves a 9-member satellite constellation, one of which wilt be an advanced TRMM-like "core" satellite carrying a dual-frequency Ku-Ka band radar (DFPR) and a TMI-like radiometer. The other eight members of the constellation will be considered daughters of the core satellite, each carrying some type of passive microwave radiometer measuring across the 10.7 - 85 GHz ,frequency range - likely to include a combination of lightweight satellites and co-existing operational/Experimental satellites carrying passive microwave radiometers (i.e., SSM/I and AMSR-E & -F). The constellation is designed to provide no worse than 3-hour sampling at any spot on the globe using sun-synchronous orbit architecture for the daughter satellites, with the core satellite providing relevant measurements on internal cloud-precipitation microphysical processes and the "training-calibrating" information for retrieval algorithms used on daughter satellite measurements. The GPM is organized internationally, currently involving a partnership between NASA in the US, NASDA in Japan, and ESA in Europe (representing the European community nations). The mission is expected to involve additional international participants, sister agencies to the mainstream space agencies, and a diverse collection scientists from academia, government, and the private sector, A critical element in understanding the scientific thinking which has motivated the GPM project is an understanding of what scientific problems TRMM has and has not been able to address and at what scales. The TRMM satellite broke important scientific ground because it carried to space an array of rain-sensitive instruments, two of which were specifically designed for physical precipitation retrieval. These were the 9-channel TRMM Microwave Imager (TMI) and the 13.8 GHz Precipitation Radar (PR). By the same token, because TRMM is a single satellite in a low inclination, low altitude, non-sun-synchronous orbit, it cannot provide global coverage or regular diurnal sampling. These features are essential for many current scientific inquiries involving physical processes of climate and the global water cycle, the modeling of hydrometeorological-biogeochemical cycling, and coupled land-atmosphere/ocean-atmosphere exchanges. Moreover, TRMM has not been able to retrieve explicit properties of the drop size distribution (DSD), a final major barrier to making accurate rain measurements, because the single frequency TRMM radar cannot measure differential reflectivity. which is a minimal requirement for attacking rain retrieval within the framework of extinction cross-section-dependency. GPM is expected to surmount much of the DSD retrieval problem because its core satellite wilt have the capacity to make differential reflectivity measurements with its Ku-Ka band radar (13.6 - 35 GHz) called DFPR - being developed by NASDA/CRL in Japan. This paper will provide an overview of the above issues as well as present a discussion on the expected measurement improvements.

Smith, Eric A.↗

AIRS Science Accomplishments Version 4.0/Plans for Version 5

This talk is about accomplishments with AIRS data and what we have learned from almost three years of data what part of this is emerging in Version 4.0 what part we would like to see filtering into Version 5.0 and what part constitute limitations in the AIRS requirements, such as spectral and spatial resolution, which have to be deferred to the wish list for the next generation hyperspectral sounder. The AIRS calibration accuracy at the 1OOmK and stability at the 6 mK/year level are amazing. It establishes the unique capability of a cooled grating array spectrometer in Earth orbit for climate research. Data which are sufficiently clear to match the radiometric accuracy of the instrument, have a yield of less than 1%. This is OK for calibration. The 2616/cm window channel combined with the RTG.SST for tropical ocean allow excellent assessment radiometric calibration accuracy and stability. For absolute calibration verification 100mK is the limit due to cloud contamination. The 10 micron window channels can be used for stability assessment, but accuracy is limited at 300mK due to water continuum absorption uncertainties.

lessons learned↗

Land Surface Temperature Product Validation Best Practice Protocol Version 1.0 - October, 2017

The Global Climate Observing System (GCOS) has specified the need to systematically generate andvalidate Land Surface Temperature (LST) products. This document provides recommendations on goodpractices for the validation of LST products. Internationally accepted definitions of LST, emissivity andassociated quantities are provided to ensure the compatibility across products and reference data sets. Asurvey of current validation capabilities indicates that progress is being made in terms of up-scaling and insitu measurement methods, but there is insufficient standardization with respect to performing andreporting statistically robust comparisons.Four LST validation approaches are identified: (1) Ground-based validation, which involvescomparisons with LST obtained from ground-based radiance measurements; (2) Scene-based intercomparisonof current satellite LST products with a heritage LST products; (3) Radiance-based validation,which is based on radiative transfer calculations for known atmospheric profiles and land surface emissivity;(4) Time series comparisons, which are particularly useful for detecting problems that can occur during aninstrument's life, e.g. calibration drift or unrealistic outliers due to undetected clouds. Finally, the need foran open access facility for performing LST product validation as well as accessing reference LST datasets isidentified.

best practice↗

Submm polarimetric radiometers for investigations of distribution and size of ice in clouds' top layers

The sources of uncertainty in climate models are many and varied. Over the years, experiment and theory have reduced their importance and extent, but the effect of clouds, and ice clouds in particular, remains poorly understood. The effects of ice clouds are often used as tuning parameters, to balance the budget of incoming and outgoing radiation at the top of the atmosphere and achieve energy equilibrium. NASA's Aerosol, Cloud and Ecosystems (ACE), an Earth Science Decadal Survey (DS) mission, recommends that a science payload with submillimeter wave (sub-mm) and longwave infrared(LWIR) radiometers be developed for such cloud ice measurement. This paper reports on the calibration and characterization of the sub-millimeter channels of one such instrument.

G De Amici↗

Arctic sea ice albedo from AVHRR

The seasonal cycle of surface albedo of sea ice in the Arctic is estimated from measurements made with the Advanced Very High Resolution Radiometer (AVHRR) on the polar-orbiting satellites NOAA-10 and NOAA-11. The albedos of 145 200-km-square cells are analyzed. The cells are from March through September 1989 and include only those for which the sun is more than 10 deg above the horizon. Cloud masking is performed manually. Corrections are applied for instrument calibration, nonisotropic reflection, atmospheric interference, narrowband to broadband conversion, and normalization to a common solar zenith angle. The estimated albedos are relative, with the instrument gain set to give an albedo of 0.80 for ice floes in March and April. The mean values for the cloud-free portions of individual cells range from 0.18 to 0.91. Monthly averages of cells in the central Arctic range from 0.76 in April to 0.47 in August. The monthly averages of the within-cell standard deviations in the central Arctic are 0.04 in April and 0.06 in September. The surface albedo and surface temperature are correlated most strongly in March (R = -0.77) with little correlation in the summer. The monthly average lead fraction is determined from the mean potential open water, a scaled representation of the temperature or albedo between 0.0 (for ice) and 1.0 (for water); in the central Arctic it rises from an average 0.025 in the spring to 0.06 in September. Sparse data on aerosols, ozone, and water vapor in the atmospheric column contribute uncertainties to instantaneous, area-average albedos of 0.13, 0.04, and 0.08. Uncertainties in monthly average albedos are not this large. Contemporaneous estimation of these variables could reduce the uncertainty in the estimated albedo considerably. The poor calibration of AVHRR channels 1 and 2 is another large impediment to making accurate albedo estimates.

Lindsay, R. W.↗

Sensitivity of satellite-derived net shortwave irradiance at the Earth's surface to radiometric calibration

The effect of radiometric calibration uncertainties on satellite-derived net shortwave irradiance at the Earth's surface was examined. Net shortwave irradiance sensitivity to calibration is expressed as a function of two basic components that depend on surface and cloud albedo sensitivities, respectively. The analysis of these sensitivities for a wide range of atmospheric and surface conditions, as well as radiation geometries, shows that a 10 percent uncertainty in the calibration induces up to 40 W/sqm errors in instantaneous net shortwave irradiance (negative when the calibration uncertainty is positive). The maximum relative errors are obtained in overcast conditions when cloud albedos are high. On a monthly time scale, the induced error becomes typically 13 W/sqm in the tropics and 16 W/sqm in higher latitude regions during summer. The error almost vanishes at high latitudes during winter. A 10 percent positive uncertainty in the calibration gives a net shortwave irradiance error similar to that induced by the 3 hr sampling of the ISCCP Project.

Gautier, C.↗

Inter-Calibrating CERES Instrument Fluxes Utilizing the CERES Instrument Geostationary Scan Mode Observations

The NASA Clouds and the Earth’s Radiant Energy System (CERES) project provides the scientific community observed top-of-atmosphere (TOA) fluxes to monitor the Earth’s energy imbalance and validate climate models. The CERES instruments onboard the Terra, Aqua, SNPP and NOAA-20 satellites need to be inter-calibrated to provide a continuous and consistent TOA flux record contained in the CERES Energy Balanced and Filled (EBAF) product. The SNPP and NOAA-20 satellites are positioned a half an orbit apart within the same sun-synchronous orbit (1:30 PM equatorial crossing time) thus preventing any direct time-matched observations. The CERES project designed the geostationary scan mode (GEOscan) to inter-calibrate the Geostationary Earth Radiation Budget (GERB) broadband measurement onboard the Meteosat 8-11 satellites. By rotating the orientation of the CERES instrument scan to match the angular configuration of the geostationary scan mode, the comparison of both angle and time matched observations suitable for inter-calibration is possible. To determine if the GEOscan mode is useful for inter-calibrating two CERES instruments placed in the same 16-day repeating orbit, the CERES project placed the Terra and Aqua CERES instruments in GEOscan mode once every 6 days over a rotation of five geostationary domains beginning in February 2023. The GEO imager narrowband to broadband derived radiances are used as transfer radiometers to compare the Terra and Aqua CERES observed radiances. Since both the Terra and Aqua CERES instruments are in GEOscan mode over the same GEO domain and day, the GEO imager calibration is expected to be consistent between the Terra and Aqua overpass times. Any GEO imager narrowband to broadband regional biases should be similar for the Terra and Aqua overpasses. The GEOscan mode Terra and Aqua CERES inter-calibration coefficients for both shortwave and longwave broadband radiances will be compared against the CERES instrument team’s coefficients to determine the viability of this approach. Improvements in the GEO imager narrowband to broadband approaches will also be investigated and verified within this framework.

Kyle Itterly↗

Evaluation of Spectral Band Adjustment Factors for Cross-Calibration of Visible Imagers

The CERES EBAF dataset provides TOA SW and LW fluxes for long-term monitoring of the Earth’s energy balance and to validate climate models. The EBAF products, based on the Terra and Aqua CERES instrument observed radiances, rely on coincident measurements from the onboard MODIS imagers to determine cloud properties that are used in the angular distribution model scene selection required to convert the CERES observed radiances into flux values. Once the Terra and Aqua orbits start drifting outside of their 15-minute window, the CERES project will rely solely on the NOAA-20 CERES observations. A seamless transition of fluxes and clouds can only occur if the analogous MODIS and VIIRS channels are properly inter-calibrated. The visible band (0.65 µm) in MODIS (band 1) and VIIRS (M5 or I1) is critical for retrieving the cloud mask and optical depth. The spectral response functions (SRF) of these bands differ noticeably and will require scene dependent spectral band adjustment factors (SBAF) for proper radiometric scaling between them. Fortunately, the VIIRS I1 and M5 bands are calibrated using the same solar diffuser as a reference, which implies that band reflectance differences must be due to the spectral disparity. The coincident I1 and M5 TOA reflectance measurements provide the optimal opportunity to validate SBAFs over many surface and cloud conditions. The CERES project maintains SCIAMACHY, GOME-2, Hyperion, and radiative transfer model-based scene-stratified hyper-spectral reflectance measurements that can be convolved with sensor pair SRFs to compute the corresponding SBAF. This study will evaluate the SCIAMACHY, GOME-2, Hyperion, and RTM based SBAFs over tropical ocean targets used in SNO inter-calibration of MODIS and VIIRS, including clear-sky ocean, deep convective clouds (DCC), and liquid cloud targets in terms of their applicability to absolute intercomparison of visible imagers. The large SCIAMACHY and GOME-2 footprints and the lack of Hyperion cloudy scenes will impact the resulting SBAFs and necessitates the need for future CLARREO hyper-spectral reflectances to decrease SBAF uncertainties Preliminary results indicate that the SCIAMACHY and GOME-2 based SBAFs for the VIIRS I1 and M5 band pairs may differ by 1.5% for some ATO scene types. Because most of the modern GEOs visible band SRFs encompass the VIIRS I1 band SRF, these evaluations are critical to ensure that the MODIS, VIIRS, and GEO clouds and fluxes are consistent. SBAFs for Libya-4, Dome-C and other Earth invariant target will also be evaluated.

D. R. Doelling↗

CCN data from TAMU TRACER campaign in the Houston TX region from July to September 2022

During TRACER, the Texas A&M Rapid Onsite Atmospheric Measurements Van (ROAM-V) was deployed to capture airmasses behind (maritime) and ahead (continental) of the passage of the sea-breeze front through Houston. On select sampling days, ROAM-V sampled in the morning/mid-day on the coast and then transited to a second inland site for the afternoon/evening. The suite of instruments deployed on ROAM-V included a Condensation Particle Counter (CPC; GRIMM Model 5.403 CPC), Scanning Mobility Particle Sizer (SMPS; TSI 3750 detector, TSI 3082 classifier, TSI 3088 neutralizer, TSI 3081A Differential Mobility Analyzer), Cloud Condensation Nuclei counter (Droplet Measurement Technologies CCN Counter), micro pulse lidar (Droplet Measurement Technologies Micro Pulse LiDAR (miniMPL)), and a Davis Rotating Uniform size-cut Monitor (DRUM; DRUMAir 4-DRUM). Before sampling at each location, the latitude and longitude were recorded using the GPS on the phone application “My Altitude”. Onboard the ROAM-V, aerosol samples are drawn through a shared isokinetic inlet at a flow rate ranging from 3.5 to 7.0 LPM. A portion of this flow is directed through a cyclone impactor (Brechtel, Inc. Model SCC 0.732) and 0.5 LPM is directed to the CCN. To calculate particle losses, we used a two-step method. First, the measured SMPS size distributions were used to calculate particle loss through the inlet during sampling. Second, the corrected SMPS data was used to calculate the average of the total losses per scan down the CCN line. Then, the correction was applied to the CCN data. This calculation was done separately for each deployment location due to changes in the measured size distributions between locations. Particle loss from diffusion (based on Kesten, 1991 and Gormley, 1949), inertial impaction in 90-degree bends (based on Aerosol Measurement, 2011 and Crane, 1977), and cyclone impactor efficiency (based on Dirgo, 1985) were included in the loss calculation. When the SMPS was not sampling at a location (in the case of an instrument malfunction or operator error), the reported CPC data was corrected with an average of the total losses for the entire campaign at the specified deployment location (e.g., if we needed to correct Galveston data, then the average of all calculated losses at Galveston was taken). These flatline corrections were used for all data on 22/07/13, 22/07/20, 22/07/22, and the data from Galveston on 22/08/09. The supersaturation uncertainty is estimated conservatively at +/- 0.03%, where variation in the inlet temperature, pressure, and calibration technique prevents a more accurate measurement. Confidence in the reported supersaturation measurements is based on a pre-campaign calibration (following the methods from our previous work and Deng, 2014 based on Rose, 2008) in addition to inter-comparisons with the DOE for two days (22/08/18 and 22/09/01) where TAMU was co-located with AMF1. The inter-comparisons show good agreement between our instrument and the DOEs instrument on both days at all supersaturations. After the last inter-comparison on 22/09/01, there was no indication of a malfunction by our instrument through the rest of the campaign. Unfortunately, the instrument was dropped during demobilization. A post-campaign calibration was conducted, which showed a substantial departure from the pre-campaign calibration. The drop may have damaged the instrument’s ability to produce the desired supersaturations. Therefore, we do consider the data after 22/09/01 to be correct, but it should be used with caution. The CCN counter sampled for 3 minutes at each supersaturation setpoint (0.2, 0.4, 0.6, 0.8, 1.0, and 1.2%). At the end of a cycle, the instrument was set to 0.01% supersaturation for 5 minutes. The data is comprised of the last 60 seconds of each supersaturation set point (0.2, 0.4, 0.6, 0.8, 1.0, and 1.2%) to ensure the instrument stabilized and was able to reach thermal equilibrium. We removed the data during the periods where there were operational difficulties, setup, or maintenance. This data was collected for ARM Field Campaign AFC07055 and supported by DOE ASR grant DE-SC0021047. For any further questions, please feel free to contact the instrument PI, Sarah D. Brooks, sbrooks@tamu.edu. Rose et. al. Calibration and Measurement Uncertainties of a Continuous-Flow Cloud Condensation Nuclei Counter (DMT-CCNC): CCN Activation of Ammonium Sulfate and Sodium Chloride Aerosol Particles in Theory and Experiment. Atmos. Chem. Phys., 8, 1153-1179, 2008. Deng et. al. Using Raman Microspectroscopy to Determine Chemical Composition and Mixing State of Airborne Marine Aerosols over the Pacific Ocean. Aerosol Science and Technology, Vol 48, Issue 2, 2014. Kesten et. al. Calibration of a TSI Model 3025 Ultrafine Condensation Particle Counter. Aerosol Science and Technology, 15:2, 107-111, 1991. Gormley et. al. Diffusion from a Stream Flowing through a Cylindrical Tube. Proceedings of the Royal Irish Academy, Vol 52, 163-169, 1948. Aerosol Measurement: Principles, Techniques, and Applications, Third Edition. John Wiley & Sons, Inc, 2011. Crane et. al. Inertial Deposition of Particles in a Bent Pipe. Journal of Aerosol Science, Vol 8, 161-170, 1977. Dirgo et. al. Cyclone Collection Efficiency: Comparison of Experimental Results with Theoretical Predictions. Aerosol Science and Technology, 4:4, 401-415, 1985.

54 ENVIRONMENTAL SCIENCES↗

Status of the GSICS VIS/NIR DCC Calibration Efforts

This year's goals for the GSICS VIS/NIR group is to finalize the VIS/NIR demonstration product requirements and to process the product for public dissemination provided on the GSICS web page. The GSICS VIS/NIR group members have been working on a unified calibration approach among various agencies. Two calibration methods have been chosen for the visible bands, deep convective clouds (DCC) and lunar invariant targets. To come to consensus across the agencies, each step of the DCC process will be outlined. Brief discussions are to follow to determine any outstanding issues. The presentation will review the DCC calibration process implemented by the CERES calibration team. CERES has already implemented the DCC method across 18 geostationary satellites. The various agencies have taken the framework and optimized the method for their particular geostationary satellite. Several new improvements will be discussed, such as deseasonalization of the DCC reflectances, impact of the bidirectional model, and update frequency.

David Doelling↗

LMC clusters - Age calibration and age distribution revisited

The empirical age relation for star clusters in the Large Magellanic Cloud presented by Elson and Fall (1985) are reexamined using ages based only on main-sequence turnoffs. The present sample includes 57 clusters, 24 of which have color-magnitude diagrams published since 1985. The new calibration is very similar to that found previously, and the scatter in the relation corresponds to uncertainties of about a factor of 2 in age. The age distribution derived from the new calibration does not differ significantly from that derived in earlier work. It is compared with age distributions estimated by other authors for different samples of clusters, and the results are discussed.

Elson, Rebecca A.↗

Progress on the National Solar Radiation Data Base (NSRDB): A New DNI Computation

This study introduces a new technique to compute direct normal irradiance (DNI) for improving the National Solar Radiation Data Base (NSRDB). A finite-surface integration algorithm is developed to compute solar radiation in differential solid angles and efficiently infer its contribution to a surface perpendicular to the solar direction. A lookup table of cloud bi-directional transmittance distribution function (BTDF) is developed by use of the discrete ordinates radiative transfer (DISORT) model for possible solar and observing directions and various cloud optical and microphysical properties. In each solar incident direction, DNI is given by the cloud BTDFs from approximately 200 differential solid angles. The simulated DNI is calibrated and evaluated using surface observations at the National Renewable Energy Laboratory's (NREL's) Solar Energy Research Laboratory (SRRL) and the Atmospheric Radiation Measurement (ARM) Southern Great Plains (SGP) facility.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Estimating noise levels of remotely sensed measurements from satellites using spatial structure analysis

A technique is presented whereby the noise level of satellite measurements of the atmosphere and earth can be estimated. The technique analyzes a spatial array of data measured by a satellite instrument. A minimum of about 200 satellite measurements is required, preferably in a regular pattern. Statistical structure analysis is used to describe a combination of the mean gradient and noise in the data. The noise level is then estimated by separating out the gradient information and leaving only the noise. Results are presented for four satellite sounding instruments, and effective blackbody or brightness temperature noise levels were compared to prelaunch specifications or inflight calibrations for each instrument. Comparisons showed that in the absence of cloud-contaminated measurements (in the case of infrared data) and away from the highly variable ground surface, the noise level of various satellite instruments can be obtained without the need for calibration data. The noise levels imply how much spatial averaging is possible, without smearing the detected geophysical gradient, and how much is necessary, to meet the absolute signal accuracy requirements for the intended use of the satellite measurements.

Hillger, Donald W.↗